This function is available only if the drain option
is present on the Power Controller.
Please Note:
English
When the water level is low, a low tone
interval beep and “FILL” will be displayed to
alarm the user. There are two possible ways
to fill water levels, automatically or manually,
depending on the model.
The auto Combi heater has a solenoid valve,
which will automatically react to the low level
of water. The water inlet will open to fill up
the tank and steamer session can be
conti-nued without intervention.
In the manual fill, the alarm beeps and
“FILL” will be displayed as long as the user
fills the tank.
However if the user does not refill the tank
and it becomes empty, a high tone interval
beep and “dry” display will alarm the user.
The steamer will automatically be switched
off now, only the heater will be working.
The automatic refill mode will refill itself now,
if it did not refill its tanks earlier. Always
check that the water supply is open before
using the automatic refill Combi heater!
2.3.2 Water refill
10 minutes after the steamer session, the
heater will automatically dry the sauna
room. The cabin drying is set to 30 minutes
at 70°C; the fan speed is at 100%. The
total drying state will take 40 minutes. The
remaining cabin drying time will be
displayed on the interface board.
If the steamer operation is changed to
heater only, there will be no cabin drying at
the end of the session.
The cabin drying session can be stopped
earlier by pushing the power button.
2.3.3 Cabin drying
This function is activated 1.5 hours after
the steamer session time or straight after
cabin drying.
The drain function can be activated in two
ways:
The automatic drain function can be
enabled or disabled when the control unit is
in “OFF” mode. Long press the mode
button and at the same time turn on
controller by pressing the pre-set button.
There will be feedback on the display. If the
automatic drain is on, “Adr” and “on” will
be constantly displayed in sequence. When
it is off, “Adr” and “off” will be displayed.
Long press the Power button to drain
the tank without delay
Automatic drain after 1.5 hours after
steamer session, i.e. 1.5 hours after the
user has pressed the Power button or
1.5 hours session time has ended.
1.
2.
2.3.4 Automatic drain (not in all models)
The state for “HOT” depends on the second
sensor, the bench sensor. If it is a
temperature sensor only, and the bench
temperature in the sauna room is 56°C or
more, the steamer cannot be activated. With
the temperature sensor, the user can
choose the relative time for the steamer to
be on, within 30-100% of the session time.
However, if the second sensor is combined
temperature humidity sensor, the maximum
bench temperature for the steamer to work
is 80°C, as long as the relative humidity in
the sauna room is not too high. With the
combined sensor, the user can choose the
relative humidity inside the sauna room.
The steamer can be switched off manually
by pressing the mode button for less than 3
seconds.
6