Corresponding formula value of address code
Every light should set a DMX address code in order to receive the signal when
you are using the controller to control multi lights.
The address code of the present light=(address code of last light)
+(channel quantity of the controller). This light with 2 channels,if the
controller is 16channels, the DMX address code of the first light is:001, the second
light should be: 017,the third light should be: 033,the fourth light should be:049,
analogously.
2. Usage of the Signal Cable & Connector
The connection between the output of master light and input of the salve
light, it’s available to use the 3 pins XLR cable which provided by the
manufacturer. Signal cable from the DMX output of the controller to the
input of the first master light, and connect to the DMX input of second
slave light from the DMX output of the first master light, analogously,
till connected all the slave lights, and insert the last connector to the output of the
final light.
If you want to prolong the connection of signal cable, the connection
of the pins between male connector and female connector should be:1 to
1; 2 to 2; 3 to 3,or it will cause communication interruption.(Notice:
the diameter of core of every cable should be 0.5mm at least,double core
shelter cable should be used).The signal connecting must use the attached
3 pins X LR cabl e. N otice, all the internal lead wire of the 3 pins XLR
cable should not touch to each other or connect to the connector.
The light is available to receive the DMX512 signal, connect the signal
plug to the panel which marked with “IN” , and connect it to the next light.
then, connect to the “IN”of next light from the “OUT”. The DMX signal
terminal organ is recommended when the lighting signal is connecting. It
will avoid to damage the signal which caused by the noise, DMX terminal
organ is a XLR connector, connect with a 120Ωresistor between the pin 2 and pin 3 of
the XLR connector, and connect it to the last OUTPUT socket of the final light.
see picture: