GENERAL DESCRIPTION
GAS DETECTOR FOR DOMESTIC INSTALLATION
SE230K-SE233K
Made
in
Italy
This document refers to gas detectors: SE230K-SE233K series marked Tecnocontrol.
LIMINOUS AND ACOUSTIC SIGNALISATIONS
LIGHTING DELAYS
The catalytic sensor in the SE230K/SE233K, need to be heated for
about one minute of working in a correct way and for that reason,when
the detector is lighted on the green led it will lighten to indicate that
the sensor is in the heating phase. During this time, all the detection
functions will be inhibited.
Model
SE230KM
SE230KG
SE233KM
SE233KG
Power supply
230Vac-50/60Hz/12Vdc
230Vac-50/60Hz/12Vdc
230Vac-50/60Hz/12Vdc
230Vac-50/60Hz/12Vdc
Logic
Negative
Negative
Positive
Positive
Gas detected
Methane
LPG
Methane
LPG
If, after about five minutes after turning on the detector, all three LEDs
blink, this indicates a sensor problem. In this case the sensor must be
replaced.
OPERATING PROBLEMS
These gas detectors are provided, on the front panel, by three lumi-
nous signalisations:
-GREEN LED (ON): indicates that the instruments is powered.
-YELLOW LED (FAULT): Indicates that the gas sensor is damaged.
-RED LED (ALARM): Indicates that the gas concentration
measured in the air exceeds the alarm threshold.
In case of damage of the sensor, the gas detector is able to indicate the
wrong function, lightning the yellow led and activating a sound alarm
with two seconds’ of intermittence. In case of alarm the detector light-
ning the red led and after 20 seconds the buzzer emits a sound alarm
and the relay activates.
Attention: the installation and the out of service of the instrument
must be done by skilled personnel only. The installation of gas and
the possible stopping device must be in according to the national and
in force prescriptions law.
The instrument has to be installed:
- the detectors SE230KM and SE233KM for methane at a maxi-
mum distance of 30 cm from the ceiling; the detectors SE230KG and
SE233KG for LPG at a maximum distance of 30 cm from the floor.
- they should be fixed at a distance comprises from 1 meter and 4
meters by the gas device (kitchen, boiler room, etc..).
- possible in every room in which there is a gas device and in resi-
dences with more than one floor, at least one detector for each floor.
The instrument does not have to be installed:
- directly over the sink or on the gas device.
- in small rooms where alcohol can be utilised, ammonia and spray
bottles of gas or other substances with flying solvents.
- in low ventilated environments.
- near to walls or hindrance that can stop the gas flow to the detector,
or near to exhausters or fans that can divert the air flow.
- in environment in which the temperature can arrive over 40°C or
under –10°C
-in the environment with a lot of humidity or vapours.
DETECTOR POSITIONING
INSTALLATION PROCEDURES
ELECTRICAL CONNECTION
POWER SUPPLY
Attention: The electrical connection has to be carried out by spe-
cialized technical staff. The detectors are power supplied 230Vac
50/60Hz through connecting terminal one and two, or 12Vdc by con-
necting terminal 3 (+) and 4 (-) (Fig.2). It has to be provided with an
device, to be disowned from the detector and the feeding net, with min-
imun 3 mm contact distance in accordance wit has written in the “Euro-
pean Standard EN 60335-1”.
Fig.2
or
The SE230K and SE233K are gas detectors for methane and LPG that
advices with an optical and acoustic signal the presence of gas in the
environment.
The SE230K/SE233K detectors are calibrated to notice existent gas
in the environment up to 10% less from the explosion concentration
L.E.L. (Low Explosion Limit), this threshold can change following the
environmental conditions but it will not be over passed, during the first
4 years of use of the 15% L.E.L., after that period the instrument have
to be put out of order or resend to Tecnocontrol S.r.l. for a complete
substitution of the device.
With that aim, the package is provided with a printed label on were is
indicated the correct working period (4 years from installing date); this
printed label have to be filled from the installer on the frontal panel of
the detector during the installation.
DOWNLOAD THE MANUAL USING THE FOLLOWING QR
CODE, OR FROM THE FOLLOWING WEBSITE:
www.gecasrl.it - www.tecnocontrol.it
By using an screwdriver unscrew on the right hand side the instru-
ment and uncover it. (Fig.1).
Fig.1
Positioning in the correct way the base, on the board mounting 3-
moules boxes directly in the wall by using screws that are provided in
the box. For installing the dowels drilling the wall with a 5 mm drill.
INSTALLATION
1 2
Methane Detector LPG Detector
The instrument has to be installed:
- the detectors SE230KM and SE233KM for methane at a maximum
Jumper position for manualrearmed E.V. normally opened.
Jumper position for manualrearmed E.V. normally closed.
CHARACTERISTICS OF THE OUTPUT
The central unit it’s provided with an relay in exit with free contacts
without tension,contact range 8A 250Vac/ 30Vdc.
CONNECTION FOR VALVE AND REMOTE
The detector furthermore by connecting terminal (5-6) active in shut
down for an remote sensor:
For Methane: cod. SE296KM or SE230KM/SE233KM.
For LPG: cod. SE296KG or SE230KG/SE233KG.
Configuration SE230K/SE233K + SE230K/SE233K have IMQ certifi-
cation.
Configurations that includes SE296K do not have IMQ certification.
If the connecting terminals (5-6) are not used, the have to be left dis-
connected. We remind that the valve should be installed on the gas
pipes outside the room under control, since protection is use less if a
gas leak occurs at the beginning of the gas pipe.
SE230K
ATTENTION: If during operation takes place a momentary absence of power supply,
the N.C solenoid valve, closes automatically and you will need to reset it after a voltage
recovery.
In this case of alarms the coil’s relay is
maintained de-energized constantly.
In case of alarm, the contacts 8 and 9
(Fig. 3 and Fig. 4) will be closed up to
end of the alarm.
SE233K
230Vac-50/60Hz 230Vac-50/60HzNormally Open E.V.
230Vac-50/60HZ
12Vdc 12Vdc
Normally Open E.V.
12Vdc
230Vac-50/60Hz 230Vac-50/60Hz
Normally Close E.V.
230Vac-50/60HZ
12Vdc 12Vdc
Normally Close E.V.
12Vdc
The use of different systems from the calibration gas sample cylinder,
makes it impossible to verify the proper functioning of the sensor.
Even when you want to recreate the actual conditions of dangerfor
which protection the gas sensor is installed, this is inapplicable.
As an example, the supply of gas from the normal home kitchenequip-
ment.
Our detectors are calibrated at 10% LEL (Lower Explosive Limit).
The explanation is simple: lets suppose to have a kitchen measuring 3
meters wide by 4 meters in length, and with height of 3 meters.
- The volume of the kitchen is equivalent to 4 x 3 x 3 that is 36 m3,equal
to 36,000 Lt.
When 4,4% of the volume of the kitchen, is filled of natural gas, in the
room a dangerous mixture is created.
- This 4,4% is called L.E.L (Lower Explosive Limit).
- In our case a 4,4% of 36.000Lt correspond to 1584Lt. (L.E.L.).
- Our detectors, according to the IMQ approvals operate at 10% of
the LEL, then 10% of the value of 1584Lt, that in this case is 158,4LT,
THEREFORE ONE THENTH OF THE LOWER EXPLOSIVE LIMIT
(L.E.L.).
Taking into consideration the fact that the house cooker has a gas noz-
zle of a few tenths of a millimetre and that the gas pressure is of a few
millibars, the gas flow would allow the delivery of 158,4 litres of gas
(sufficient to make the sensor react) only after hours.
Even with broader gas supply sources, the peculiar and strong smell
of natural gas, makes impossible the human presence and it make evi-
dent the serious danger situation even when the natural gas saturation
is still too little to allow the explosion.
LOWER EXPLOSIVE LIMIT (L.E.L)
We recommend to contact the installer at least once a year for a
general inspection.
IMPORTANT: do not use pure gas, such as a lighter directly on
the sensor since the sensor could be damaged.
PERIODICAL TESTING
Connection for normally opened E.V. (230Vac), manual rearmed (relay nor-
mally deactivated) or by a second detector (SE230K).
Connection for normally closed E.V. (230Vac), manual rearmed (relay normally
activated) or by asecond detector (SE233K).
Connection for normally closed E.V. (12Vdc), manual rearmed (relay normally
activated) or by asecond detector (SE233K).
Connection for normally opened E.V. (12Vdc), manual rearmed (relay normally
deactivated) or by a second detector (SE230K).
SE230K + SE230K + Normally Open E.V.
SE233K + SE233K + Normally Close E.V.
Fig.3
Fig.4
Fig.5
Fig.6
34
In this case the coil’s relay is main-
tained energized constantly to ensure
intrinsic safety relay operation.
In case of alarm, the contacts 7 and 8
(Fig. 5 and Fig. 6) will remain closed
until the end of the alarm.
SE230K SE230K
SE230K SE230K
SE233K SE233K
SE233K SE233K
The instrument has to be installed:
- the detectors SE230KM and SE233KM for methane at a maximum
After the installation it is possible to check the correct use ofthe instru-
ment by pushing for at least 2 seconds the TEST button on the board.
Using this method all the leds will be lighted, also the acustic alarm will
be active, and the exit relay for a period of five seconds.
The E.V. if connected, has to be manual rearmed.
OPERATING CONTROLS
For the clining of the instrument utilize a cloth to take away the dust
from the covering. Don’t try to open or disassemble the detector, it
could cause an electric shock and damege the product.
Note that the sensor employed has a good resistance towards prod-
ucts such as sprays, detergents, alcohol, glues andpaints.
However, these products could contain substances which, if in great
quantity, could interfere with the sensor and cause false alarms.
We recommend to ventilate the room where products like these can
be used.
Note that the detector is not able to detect gas leaking outside the
room where it is installed, neither inside walls or under the floor.
To make gas (methane and LPG) nose identifiable, gas is added with
a particularly disturbing smelling substance. Small gas quantities com-
ing out from left open cookers for some minutes do not cause the gas
detector alarm signalling even if it is clearly nose perceptible; in fact
the quantity of gas presents in the environment can be under the alarm
threshold.
Please remember that the gas detector cannot work withoutpower
supply.
WARNING
1) extinguish all naked flames.
2) turn off the gas supply at the gas emergency control and/or, with a
LPG supply, the storage tank.
3) do not switch on or off any electrical lights. Do not activate any
electrically powered devices.
4) Open both doors and windows to increase room ventilationIf the
alarm stops, it is necessary to identify the alarm reason and act ac-
cordingly.
If the alarm condition continues and the cause of the leak is not appar-
ent and/or cannot be corrected, vacate the premises and immediately
notify the gas emergency service.
WARNING!
In case of alarm:
TECHNICAL CHARACTERISTICS
- Power supply: 230Vac, 50/60Hz / 12Vdc 2,5W.
- Power dissipation: 20mA max.
- Operation temperature: -10°C…… +40°C.
- Relative humidity: 30%…… 90%.
- The operative level to intervene at an concentration of the 10% of the L.E.L.
(the lower explosion limit) of the gas.
Intentional delay of the starting connection to the instrument :
1 minute approximately.
- Intentional alarm and relay time delay: about 20 seconds
- Acoustic signalisation: 85dB (A) in 1 meter
- Electronic auto-diagnosis with signalising of eventual abnormalieties
- Grade of protection: IP42
- According to Standard CEI UNI EN50194-1:2009
SALES CONDITION
THE PRESENT CERTIFICATE IS THE ONLY DOCUMENT TO HAVE THE RIGHT OF
REPARATION OF DEVICE IN WARRANTY
• The product is warranted for 24 month from purchase date.
• Any damages caused by tampering and incorrect use or installation will be
not covered by warranty.
• The warranty is valid only if is full compiled.
• In case of defects covered by warranty, the producer will repair or replace
the free product.
PERFORMANCES OUT OF WARRANTY:
When warranty’s terms are spent, the eventual reparations will debited in ac-
cording to the replaced parts and to the hand costs.
WARRANTY CERTIFICATE
COMPILE AND SEND IN CASE OF DAMAGE.
DEVICE:
SE230KM SE230KG SE233KM SE233KG
Serial number (s.n.)___________________________________________
DEALER
Stamp:
Date of purchase:
________/________/________
USER
Surname and name____________________________________________
Address______________________________________N°_____________
City_________________________________________________________
Telephone____________________________________________________
TO COMPILE BY THE INSTALLER:
Installation date ______________________________________________
Substitution date _____________________________________________
Installation local ______________________________________________
Instruments’ serial number ______________________________________
(to read on the internal part of the plastic involucres)
Stamp
Sign ______________________________________________________
Ordering Information: Part No. TCSE233KM

This manual suits for next models

5

Popular Security Sensor manuals by other brands

Perenio PECLS01 manual

Perenio

Perenio PECLS01 manual

LST Series 65/XP95 Specifications

LST

LST Series 65/XP95 Specifications

Distech Controls MS2 Series Hardware installation guide

Distech Controls

Distech Controls MS2 Series Hardware installation guide

Petzl Stop manual

Petzl

Petzl Stop manual

Alarmtech GD 335 instruction manual

Alarmtech

Alarmtech GD 335 instruction manual

WATERGUARD Puddle user guide

WATERGUARD

WATERGUARD Puddle user guide

Visonic MP-840 K9-85 installation instructions

Visonic

Visonic MP-840 K9-85 installation instructions

Thorn SwitchLite MRE SLD manual

Thorn

Thorn SwitchLite MRE SLD manual

GEV LightBoy 001237 MONTAGE

GEV

GEV LightBoy 001237 MONTAGE

Safety Vision SV-LCD56B1 Quick installation guide

Safety Vision

Safety Vision SV-LCD56B1 Quick installation guide

EtiamPro LQS04 user manual

EtiamPro

EtiamPro LQS04 user manual

Dräger X-am 5100 Instructions for use

Dräger

Dräger X-am 5100 Instructions for use

FLYGT CLS Installation and application manual

FLYGT

FLYGT CLS Installation and application manual

SICK UE410-SD operating instructions

SICK

SICK UE410-SD operating instructions

Generex SM MD quick start guide

Generex

Generex SM MD quick start guide

Visonic DISC MCW datasheet

Visonic

Visonic DISC MCW datasheet

C.P. Electronics MWS6-PRM-LV installation guide

C.P. Electronics

C.P. Electronics MWS6-PRM-LV installation guide

Ono Sokki LG-9200 instruction manual

Ono Sokki

Ono Sokki LG-9200 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.