Schlage PIB300 User manual

P516-097
PIB300 USER GUIDE
INSTALLATION AND OPERATION INSTRUCTIONS FOR
PANEL INTERFACE BOARD
Para el idioma español, navegue hacia www.schlage.com/support
Pour la portion française, veuillez consulter le site www.schlage.com/support

2
PIB300 User Guide
CONTENTS
Overview........................................................................................................................................ 3
Getting Started .............................................................................................................................. 3
Handheld Device (HHD) ................................................................................................................ 3
PIB300 Installation......................................................................................................................... 4
Location..................................................................................................................................... 4
Wiring to the Lock...................................................................................................................... 4
Connecting the PIB300 to the Access Control Panel (ACP)...................................................... 5
Cable/Wire Specifications.......................................................................................................... 5
Typical Wiring to the Access Control Panel ............................................................................... 5
PIB300 to ACP Connection ........................................................................................................... 6
Completing Installation .................................................................................................................. 7
Access Point ACP Connections to a RS-485 Device Address ................................................. 7
Resetting to Factory Defaults ........................................................................................................ 8
www.schlage.com/support
866.322.1237

3
PIB300 User Guide
OVERVIEW
The Schlage Panel Interface Board (PIB300) provides a means of connecting RS-485 based access
point devices to a system requiring Wiegand or Clock and Data protocol (rather than direct RS-485
connection). This manual describes the installation and operation of the PIB300.
• Open Architecture platform
• Provides two-way communication with locks via a RS-485 connection
• Up to two Schlage AD-300 locks or up to two RS-485 based legacy locks communicating with the
RSI or VIP protocol may connect to an Access Control Panel (ACP) or reader interface board.
• Legacy and AD-300 locks may not both be present on the RS-485 connection.
• The trouble signal output will change state when the Anti-Tamper Switch (ATS) signals that the
PIB300 enclosure lid is open, or if an access point device indicates trouble status.
Before installing a Schlage AD-Series system, read all documentation for all products in the
installation.
RS485
AD-300
PIB300
Wiegand or
Clock & Data
Access
Control
Panel
GETTING STARTED
The following is an overview of the steps required for setting up the PIB300.
• Install the lock. See the installation guide that came with the lock, or visit
www.schlage.com/support for more information.
• Use proper wiring to the PIB300. See page 5 for more information.
• Disconnect power to the lock and Access Control Panel while connecting the PIB300.
• Familiarize yourself with the information in this user guide.
! Save this user guide for future reference.
HANDHELD DEVICE (HHD)
! The Handheld Device is used for programming and setup only.
The Handheld Device (HHD) is used to configure this device’s links and outputs. For information about
the HHD, see the Schlage Utility Software User Guide.

4
PIB300 User Guide
PIB300 INSTALLATION
Location
• The PIB300 should be located close to the Access Control Panel (wiring distance may be up to
500 feet).
Wiring to the Lock
• Power wire for locks must be appropriately sized for the distance and voltage.
• Communication wire should be suitable for use on RS-485 type networks.
• The maximum length of the RS-485 wiring from the PIB300 to Lock 2 is 4000 feet.
• Wiring of locks requires one connector via the RS-485 connector (J5).
• Connections from lock to lock should be daisy-chained (see diagram below).
• The power supply is located at or near the PIB300 for short wire runs, or local to locks if located
far from the panel.
ACP
PIB300
RS485
Lock 2
Daisy Chain
Lock 1

5
PIB300 User Guide
Connecting the PIB300 to the Access Control Panel (ACP)
! CAUTION: Disconnect the ACP power and batteries while wiring the PIB300 to the panel.
! WARNING: Because every Access Control Panel is different, always check the panel’s
instruction manual for appropriate interface wiring.
• Must be used with a UL 294 Listed Power Supply capable of sourcing at least 250mA @
12 to 24 VDC. Refer to Typical Wiring to the Access Control Panel below for how to connect DC
power to the PIB300.
Use shielded cables for the signal wiring between the PIB300 and the Access Control Panel. For
maximum wire lengths and cable specifications, see Cable/Wire Specifications below.
Cable/Wire Specifications
Application Part Number AWG Description Max Run Length
DC Power Input Belden 8760 or equivalent 18 2 Conductor 1000 Feet
RS-485 Belden 9841 or 9842 or
equivalent
24 2 or 4 Conductor
shielded
4000 Feet
PIB300 to Access
Control Panel
Alpha 1298C or equivalent 22 8 Conductor
shielded
500 Feet
Typical Wiring to the Access Control Panel
J2
J8 J10J7 J11
J5
GND
TDB+
RDB+
TDA−
RDA−
LINK1 LINK2
Req to Enter
Req to Enter Gnd
Trouble
Trouble Gnd
Status
Status Gnd
Req to Exit
Req to Exit Gnd
Strike Input
Strike Input Gnd
D1/CLK
D0/DATA
Gnd
Do not connect cable
shields at PIB300
Access Control Panel
Note: Only AP1 is shown connected.
AP2 should be connected the same way.
RS485 connection
to daisy-chained
access point 1 and
access point 2
Run shielded cables
through grounded conduit.

6
PIB300 User Guide
PIB300 TO ACP CONNECTION
ACCESS CONTROL PANEL CONNECTION
Connector PIB300 Signal Access Panel Signal Description/Explanation
J2 12V+ 12 to 24 VDC
PIB300 inputs for 12 to 24 VDC
power.
If the Access Control Panel
(ACP) reader power outputs do
not source enough current for
the PIB300, use the ACP main
regulated 12 VDC power supply or
a separate UL 294 Listed 12 to 24
VDC power supply.
Power input is non polarized.
J10 for
Access
Point A
J11 for
Access
Point B
J10/J11 (1)
REQ TO
ENTER
Request to Enter Input
Signal
PIB300 output indicating when the
Access Point exterior door handle
is making a request to enter.
Connect to the Access Control
Panel Request to Enter input.
Connect only if the Access Point
needs to have Request to Enter
function.
Output is Pulled-up to 5 VDC and
can sink 50mA.
J10/J11 (2)
Request to Enter
Common Contact
(GND)
J10/J11 (3)
TROUBLE
General Purpose
Alarm Input Signal
PIB300 output indicating Trouble
is reported by the Access Point.
Logic polarity is configurable.
Output is Pulled-up to 5 VDC and
can sink 50mA.
General Purpose
Alarm Common
Contact (GND)
J10/J11 (4)
J10/J11 (5)
DOOR 1/2
STATUS
Door Status Input
Signal
PIB300 output indicates the
position of the Access Point portal,
Open/Closed.
Connect only if the Access
Control Panel needs to know the
Access Point portal state.
Logic polarity is configurable.
Output is Pulled-up to 3.6 VDC
and can sink 50mA.
J10/J11 (6)
Door Status Input
Common Contact
(GND)

7
PIB300 User Guide
ACCESS CONTROL PANEL CONNECTION
Connector PIB300 Signal Access Panel Signal Description/Explanation
J10 for
Access
Point A
J11 for
Access
Point B
J10/J11 (7)
REQ TO EXIT
Request to Exit Input
PIB300 output indicating when the
Access Point interior door handle
is making a request to exit.
Connect to the Access Control
Panel Request to Exit input.
Connect only if the Access Point
needs to have Request to Exit
function.
Output is Pulled-up to 5 VDC and
can sink 50mA.
J10/J11 (8)
Request to Exit
Common Contact
(GND)
J11 (9) +5V 5 VDC
RESERVED
5 VDC power supply pin for the
RLBD, dry contact relay board.
J8 for
Access
Point A
J7 for
Access
Point B
J8/J7 (1)
STRIKE
INPUT
Normally Open Strike
Relay Contact
Strike input monitors the access
panel strike relay.
Connect the STRIKE signal to the
normally open or normally closed
terminal of the strike relay. The
active signal state of the PIB300
is programmable with the HHD.
Connect the GROUND signal to
the common terminal of the strike
relay.
Connect only if the access point
needs to be unlocked (door) or
raised (gate).
J8/J7 (2) Common Strike Relay
Contact
J8/J7 (3) D1/CLK Clock or Data 1 Output PIB300 outputs used to present
card data to the Access Control
Panel (ACP).
For an access point with a
magnetic reader, will present
Clock and Data signals to the
Access Control Panel.
For an access point with a
Wiegand or Proximity reader, will
present Data1 and Data0 signals
to the ACP.
If initial hookup fails to operate,
switch wires at these terminals.
Output is Pulled-up to 3.6 VDC
and can sink 50mA.
J8/J7 (4) DATA Data or Data 0 Input
J8/J7 (5) GND Signal Ground
Common signal ground for
the EXIT REQ, DOOR STAT,
TROUBLE, DATA/D0 and CLK/D1
signals.

© 2010 Ingersoll-Rand Company
P516-097 ENG online Rev. 05/10-b
COMPLETING INSTALLATION
After all required connections have been made, connect the power and ACP standby batteries to the
panel.
Access Point ACP Connections to a RS-485 Device Address
The PIB300 Access Point to ACP connections are each associated with a RS-485 device address.
This association is set using the Schlage Utility Software. Please see the SUS user manual for further
information.
The PIB300 defaults to Access Point 1 connections associated with RS-485 device address 0x00 and
Access Point 2 connections associated with RS-485 device address 0x01.
RESETTING TO FACTORY DEFAULTS
! All configuration information will be deleted and the PIB300 will be reset to factory defaults!
1. Remove the main cover.
2. Press and hold both link buttons for over 3 seconds.
3. Release both link buttons. The PIB300 will blink the red lights beside each link button while
configuration reset takes place.
4. The two green lights beside the link buttons will blink 3 times when the reset is complete.
5. Replace the main cover.
Other manuals for PIB300
2
Table of contents
Other Schlage Computer Hardware manuals
Popular Computer Hardware manuals by other brands

ProX
ProX BE-U830 Quick reference guide

Oki
Oki MSM80C154S Specification sheet

ARTESYN EMBEDDED TECHNOLOGIES
ARTESYN EMBEDDED TECHNOLOGIES SharpMedia PCIE-8120 manual

InWin
InWin IW-RS104-07 user manual

Tripp Lite
Tripp Lite B132-004-RB Specification sheet

BIG TREE TECH
BIG TREE TECH Octopus MAX EZ user manual