Schluter Systems DH E RT2/BW User manual

DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
• English
• Deutsch
• Français
• Polski
• Česky
• Nederlands
• Italiano
• Español
• Русский
• Portugues
INSTRUCTIONS
GREEN COMFORT
Maximum comfort with low energy consumption

2© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
ILLUSTRATIONS
Pages.................................................................................... 3
INSTRUCTIONS
English.................................................................................. 7
Deutsch .............................................................................. 13
Français .............................................................................. 20
Polski .................................................................................. 27
Česky.................................................................................. 34
Nederlands......................................................................... 40
Italiano................................................................................ 47
Español............................................................................... 54
Русский ............................................................................. 61
Portugues .......................................................................... 68

3
DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
ILLUSTRATIONS
Pages.................................................................................... 3
INSTRUCTIONS
English.................................................................................. 7
Deutsch .............................................................................. 13
Français .............................................................................. 20
Polski .................................................................................. 27
Česky.................................................................................. 34
Nederlands......................................................................... 40
Italiano................................................................................ 47
Español............................................................................... 54
Русский ............................................................................. 61
Portugues .......................................................................... 68
BR1038A26
© 2020 OJ Electronics A/S
BR1038A27
© 2020 OJ Electronics A/S
Fig. 1
Fig. 2
BR1017A26BR1017A27

4© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
BR1017A03A
1.5m
1
2
3
BR1038A28
© 2020 OJ Electronics A/S
BR1017A03a
Fig. 3
Fig. 4
BR1017A28

5© 2020. All rights reserved. Used under license by Schlüter-Systems KG
© 2020. All rights reserved. Used under license by Schlüter-Systems KG
BR1017A05A
653 421
N
L
BR1017A06
Fig. 5
Fig. 6
BR1017A05aBR1017A06

6© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
1
2
3
4
4
BR1017A14BR1017A07
Fig. 7
Fig. 8
BR1017A07
ON
OFF
1
2
Manual Menu
Auto
BR1017A17a
Fig. 9
Udarbejdet af: Udarbejdet d.: 29.05.2015 Side 1af 1
©2015 OJ ELECTRONICS A/S •STENAGER 13B •DK-6400 SØNDERBORG
NTC 12kΩ@ 25°Celsius
°Celsius °Fahrenheit Ohm (Ω)
-10°C14°F55076Ω
0°C32°F34603Ω
10°C50°F22284Ω
20°C68°F14675Ω
30°C86°F9860Ω

7
DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
INTRODUCTION
The thermostat is an electronic PWM/PI thermostat for temperature
control by means of an NTC sensor located either externally or
internally within the thermostat.
The thermostat is for flush mounting in a wall socket. A baseplate
for wall mounting is also available.
Fig. 1 - Content
• Thermostat
• Sensor
• Display disassembly tool
This thermostat can be used as a controller for electric room
heating pursuant to EN50559.
Product programme
DH E RT2 / BW Clock-thermostat with two sensors:
floor sensor and built-in room sensor.
DH E RT5 / BW WiFi Clock-thermostat with two sensors:
floor sensor and built-in room sensor.
IMPORTANT SAFETY INSTRUCTIONS
Fig. 2 - Warnings
To avoid electric shock, disconnect the heating system
power supply at the main panel before carrying out any
work on this thermostat and associated components.
Installation must be carried out by qualified personnel in accord-
ance with appropriate statutory regulations (where required by law).
Installation must comply with national and/or local electrical codes.
Instruction
English

8© 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
Cautions
This instruction must be observed, otherwise the liability
of the manufacturer shall be voided.
Any changes or modifications made to this thermostat
shall void the liability of the manufacturer.
Maximum product lifetime is achieved if the product is not turned
o but set at the lowest possible set point / frost protection when
heat is not required.
Notice
The language used in the original documentation is
English.
Other language versions are a translation of the original
documentation.
The manufacturer cannot be held liable for any errors in the
documentation. The manufacturer reserves the right to make
alterations without prior notice.
Content may vary due to alternative software and/or
configurations.
Fig. 3 - Thermostat placement
Mounting of sensor
The floor sensor contains a safety extra-low voltage (SELV) circuit,
allowing it to be placed as close to the floor surface as possible
without having to take account of the risk of shock should the sen-
sor cable become damaged. The two wires connecting the sensor
to the mounting box must be additionally insulated, e.g. shrink flex.
To prevent loose wires in the fixed installation from coming into
contact with the terminal block for the floor sensor, they must be
restrained using cable ties.
It is strongly recommended that the cable and sensor are placed in
a non-conductive installation pipe embedded in the floor. The end
of the pipe must be sealed and the pipe placed as high as possible
in the concrete layer. Alternatively, the sensor can be embedded
directly in the floor. The sensor cable must be led through a sepa-
rate conduit or segregated from power cables.
The floor sensor must be centred between loops of heating cable.
English

9© 2020. All rights reserved. Used under license by Schlüter-Systems KG
© 2020. All rights reserved. Used under license by Schlüter-Systems KG
The sensor cable may be extended up to 30 m by means of a
separate two-core cable. Two vacant wires in a multi-core cable
used, for example, to supply current to the floor heating cable must
not be used. The switching peaks of such current supply lines may
create interference signals that prevent optimum thermostat func-
tion. If a shielded cable is used, the shield must not be connected
to earth (PE). The two-core cable must be placed in a separate
pipe or segregated from power cables in some other way.
Mounting of thermostat with built-in sensor
The room sensor is used for comfort temperature regulation in
rooms. The thermostat should be mounted on the wall approx.
1.5 m above the floor in such a way as to allow free air circulation
around it. Draughts and direct sunlight or other heat sources must
be avoided.
Fig. 4 - Opening the thermostat
1. Slide the power button down to O “0”.
2. Release the front cover ONLY use the supplied display disas-
sembly tool for removing the front cover. Insert the tool in the
slot at the bottom of the front cover, push it upwards and sup-
port the front cover.
3. Then carefully pull the front cover away, initially from the lower
part of the thermostat, then from the upper part of the thermo-
stat.
Fig. 5 - Connections
Connect the wires in accordance with the diagram. The wires must
be connected as follows:
Term. 1: Neutral (N)
Term. 2: Line (L)
Term. 3-4: Output, max. 16 A
Term. X: Do not connect
Term. 5-6: External floor sensor
Fig. 6 + 7 - Mounting the thermostat
1. Mount the thermostat in the wall socket.
2. Fit the frame and carefully press the cover onto the thermostat
- starting with the upper part of the cover, then the lower part of
the cover. Ensure that both the power slide button on the cover
and the power switch pin in the thermostat are down.
English

10 © 2020. All rights reserved. Used under license by Schlüter-Systems KG© 2020. All rights reserved. Used under license by Schlüter-Systems KG
3. Click the cover into place by applying light, even pressure.
Warning! Do not apply pressure to the corners of the display
cover or to the display itself.
DO NOT open the thermostat by releasing the four fixing clips on
the back.
Fig. 8 - Operating the thermostat
There is an ON/OFF switch on the left side of the thermostat: up is
ON - down is OFF.
The resistive touchscreen requires a soft tap with your fingertip to
register the touch.
Installer Wizzard:
The first time the thermostat is connected, push the power slide
button to On “I” The Installer Wizard on the touchscreen will guide
you through the set up of:
1. Region
2. Language
3. Date
4. Time
5. Floor Type
Programming
See user manual: http://www.schlueter-systems.com/dhert2/
FIG. 9 - Troubleshooting
If the sensor is disconnected or short-circuited, the heating system
is switched o. The sensor can be checked against the resistance
table.
Error codes
E0: Internal fault. The thermostat must be replaced.
E1: Built-in sensor defective or short-circuited. Replace the ther-
mostat, or use the floor sensor only.
English

11© 2020. All rights reserved. Used under license by Schlüter-Systems KG
© 2020. All rights reserved. Used under license by Schlüter-Systems KG
E2: External sensor disconnected, defective or short-circuited.
Reconnect the sensor if disconnected, or replace the sensor.
E5: Internal overheating. Inspect the installation.
MAINTENANCE
The thermostat is maintenance free.
Keep the thermostat’s air vents clean and unobstructed at all
times.
The thermostat may only be cleaned with a dry cloth.
APPROVALS AND STANDARDS
Regulations
The manufacturer hereby declares that the product is in conformity
with the following directives of the European Parliament:
LVD - Low Voltage Directive
EMC - Electromagnetic Compatibility
RoHS - Restriction of the use of certain Hazardous Substances
RED - Radio Equipment Directive
Applied standards and approvals
According to the following standard:
EN 60730-1, EN 60730-2-9, EN 300 328, EN 301 489-17,
EN 301 489-1, EN 62479, EN 50559
Classification
Protection from electric shock must be assured by appropriate
installation. Must be installed according to the requirements of
Class II (reinforced insulation).
ENVIRONMENT AND RECYCLING
Protect the environment by disposing of the package in
compliance with local regulations for waste processing.
Recycling of obsolete appliances
Equipment containing electrical components must not
be disposed of along with domestic waste.
It must be separately collected together with electrical
and electronic waste in accordance with current local
regulations.
English

12 © 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
TECHNICAL SPECIFICATIONS
Purpose of control Electrical underfloor heating
Method of mounting. Wall mounting in a socket or
mounting box
Supply voltage 100-240 VAC ±10% 50/60 Hz
Max. pre-fuse 16 A
Built-in interupter 2-pole, 16 A
Enclosure rating IP 21
Wire size, terminals
Current ≤ 13 A - 1.5 mm2, solid core
wire
Current > 13 A to 16 A - 2.5 mm2,
solid core wire
ELV limits realized SELV 24 VDC
Output relay Make contact - SPST - NO
Output, load Max. 16 A / 3600 W
Control principle PWM/PI
Standby consumption ≤0.5 W
Battery backup 5 years (storage)
Battery life, typical 5 years (storage) 10 years (powered)
RF frequency band* 2.4 GHz
WIFI* IEEE 802.11 b/g/n - 2.4GHz
Security* WPA/WPA2
Dimensions MxD5: H/84, W/84, D/40 mm
Build-in depth 22mm
Weight ≤200 g
Display 176x220 pixels TFT - resistive touch
Control pollution degree 2
Overvoltage category III
Type of action 1.B
Software class A
Rated impulse voltage 4kV
Ball pressure temperature (TB) 125°C
EU registered design DM/082270
Note: At very low ambient temperatues the display may respond slowly.
* Only valid for WiFi Touch Thermostats
English
© 2020. All rights reserved. Used under license by Schlüter-Systems KG

13
DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
Anleitung
Deutsch
ALLGEMEINES
Der Thermostat ist ein elektronischer PWM/PI-Thermostat zur Tem-
peraturregelung mittels extern angebrachtem oder im Thermostat
eingebauten NTC-Fühler.
Der Thermostat ist für Unterputzmontage in einer Wanddose
vorgesehen. Eine Grundplatte für Wandmontage ist ebenfalls
verfügbar.
Dieser Thermostat kann zur Steuerung von elektrischer Raumhei-
zung gemäß EN50559 verwendet werden.
Abb. 1 – Lieferumfang
• Thermostat
• Fühler
• Display-Demontagewerkzeug
Produktprogramm
DH E RT2 / BW Uhr-Thermostat mit zwei Fühlern:
Bodenfühler und eingebauter Raumfühler.
DH E RT5 / BW WiFi Uhr-Thermostat mit zwei Fühlern:
Bodenfühler und eingebauter Raumfühler.
WICHTIGE SICHERHEITSANWEISUNGEN
Abb.2 – Warnhinweise
Zum Schutz vor elektrischem Schlag ist vor der
Ausführung von Arbeiten an diesem Thermostat und
zugehörigen Komponenten die Spannungsversorgung
der Heizungsanlage am Hauptschaltschrank zu unterbrechen.
Die Installation darf nur von sachkundigen Personen gemäß den
geltenden gesetzlichen Vorgaben vorgenommen werden (sofern
gesetzlich vorgeschrieben).
Die Installation muss den nationalen und/oder lokalen elektrischen
Vorschriften entsprechen.
© 2020. All rights reserved. Used under license by Schlüter-Systems KG

14 © 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
Sicherheitshinweise
Diese Anleitung ist zu beachten. Andernfalls erlischt die
Herstellerhaftung.
Änderungen oder Modifikationen an diesem Thermostat
führen zum Erlöschen der Herstellerhaftung.
Wenn keine Wärmeanforderung besteht, kann eine maximale
Lebensdauer des Produkts gewährleistet werden, indem das
Produkt nicht ausgeschaltet, sondern auf die niedrigstmögliche
Einstellung/Frostschutz gestellt wird.
Hinweis
Diese Dokumentation wurde ursprünglich in englischer
Sprache verfasst.
Andere Sprachversionen sind Übersetzungen der
originalen Dokumentation.
Der Hersteller ist für Fehler in der Dokumentation nicht haftbar zu
machen. Der Hersteller behält sich das Recht vor, unangekündigte
Änderungen vorzunehmen.
Der Inhalt kann aufgrund einer alternativen Software und/oder
Konfiguration variieren.
Abb. 3 – Thermostat-Platzierung
Montage des Fühlers
Der Bodenfühler ist mit einem Kleinspannungs-Sicherheitskreis
(SELV) ausgestattet, womit eine Anbringung möglichst nahe an
der Fußbodenoberfläche ohne Risiko von Stromschlägen durch
ein eventuell schadhaft werdendes Fühlerkabel erfolgen kann. Die
beiden Leiter für den Anschluss des Fühlers im Klemmenkasten
müssen zusätzlich isoliert werden, z. B. mit Schrumpfschlauch.
Um einem Kontakt der Klemmenleiste des Bodenfühlers mit losen
Drähten der vorhandenen Installation vorzubeugen, müssen diese
mit Kabelbindern festgemacht werden.
Es empfiehlt sich, Kabel und Fühler in einem im Boden eingelas-
senen, nicht leitenden Installationsrohr anzubringen. Mit ver-
schlossenem Rohrende sollte das Rohr so hoch wie möglich in der
Estrichschicht eingebettet sein. Alternativ kann der Fühler direkt im
Deutsch

15
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
Boden eingebettet werden. Das Fühlerkabel ist in einem separaten
Rohr oder getrennt von Leistungskabeln zu verlegen.
Der Bodenfühler muss zwischen den Heizkabelschleifen zentriert
werden.
Das Fühlerkabel kann mit einem separaten Zweileiterkabel bis zu
30 m verlängert werden. Freie Leiter in einem z. B. das Boden-
heizkabel mit Strom versorgenden Mehrleiterkabel dürfen nicht
verwendet werden. Die Schaltspitzen einer derartigen Stromversor-
gung können Interferenzen auslösen die eine optimale Thermo-
statfunktion behindern. Wird ein abgeschirmtes Kabel verwendet,
darf die Abschirmung nicht geerdet werden. Das Zweileiterkabel
ist in einem separaten Rohr oder getrennt von Leistungskabeln zu
verlegen.
Montage eines Thermostats mit eingebautem Fühler
Der Raumfühler wird zur Regelung der Komforttemperatur in
Räumen eingesetzt. Der Thermostat ist auf der Wand ca. 1,5 m
über dem Boden und freie Luftzirkulation um ihn gestattend zu
montieren. Zugluft und direkte Sonneneinstrahlung oder andere
Wärmequellen müssen vermieden werden.
Abb. 4 – Önen des Thermostatgehäuses
1. Den Schiebeschalter nach unten in Position Aus „0“ schieben.
2. Zum Lösen der Frontabdeckung NUR das mitgelieferte Display-
Demontagewerkzeug benutzen. Dieses in den Schlitz an der
Unterseite der Frontabdeckung einstecken, nach oben drücken
und die Frontabdeckung festhalten.
3. Danach vorsichtig die Frontabdeckung entfernen, zuerst von
unten am Thermostat und dann von oben.
Abb. 5 – Anschlüsse
Die Leiter gemäß Schaltplan anschließen. Die Leiterdrähte müssen
wie folgt angeschlossen werden:
Klemme 1: Neutralleiter (N)
Klemme 2: Phase (L)
Klemme 3-4: Ausgang, max. 16A
Klemme X: Nicht benutzen
Klemme 5-6: Externer Bodenfühler
Deutsch
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG

16 © 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
Deutsch
Abb. 6 + 7 – Montage des Thermostats
1. Den Thermostat in der Wanddose montieren.
2. Den Rahmen anpassen und den Deckel vorsichtig auf den Ther-
mostat aufsetzen – beginnend mit dem oberen Teil des Deckels
und dann dessen unteren Teil. Bitte beachten, dass sich sowohl
der Schiebeschalter am Deckel als auch der zugehörige Stift im
Thermostat in unterster Position befinden.
3. Den Deckel mit leichtem, gleichmäßigem Druck auf dem
Gehäuse einrasten. Achtung! Nicht auf die Ecken der Display-
Abdeckung oder auf das Display drücken.
KEINESFALLS den Thermostat bei den vier Befestigungsschellen
auf der Rückseite önen.
Abb. 8 – Bedienung des Thermostats
Ein EIN/AUS-Schalter befindet sich auf der linken Seite des Ther-
mostats: Stellung oben ist EIN – Stellung unten ist AUS.
Der resistive Touchscreen erfordert ein weiches Antippen mit der
Fingerspitze um die Berührung zu registrieren.
Erste Einstellungen:
Zur ersten Inbetriebnahme des Thermostats den Betriebsschalter
in Position Ein „I“ schieben. Der Installationsassistent auf dem
Touchscreen führt Sie durch das Setup von:
1. Region
2. Sprache
3. Datum
4. Uhrzeit
5. Bodentyp
Programmierung
Siehe Benutzerhandbuch:
http://www.schlueter-systems.com/dhert2/

17© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
Abb. 9 - Fehlersuche und -behebung
Bei unterbrochenem oder kurzgeschlossenem Fühler wird die
Heizanlage abgeschaltet. Der Fühler lässt sich mit der Widerstand-
stabelle abgleichen.
Fehlercodes
E0: Interner Fehler. Der Thermostat muss ausgetauscht werden.
E1: Interner Fühler defekt oder kurzgeschlossen. Thermostat aus-
tauschen, oder nur den Bodenfühler verwenden.
E2: Externer Fühler getrennt, defekt oder kurzgeschlossen. Fühler
wenn getrennt anschließen, oder Fühler austauschen.
E5: Interne Überhitzung. Installation kontrollieren.
WARTUNG
Der Thermostat ist wartungsfrei.
Die Lüftungsönungen des Thermostats jederzeit sauber und frei
halten.
Den Thermostat nur mit einem trockenen Tuch reinigen.
ZULASSUNGEN UND NORMEN
Richtlinien
Der Hersteller erklärt hiermit, dass das Produkt mit den folgenden
Richtlinien des europäischen Parlaments übereinstimmt:
NSR – Niederspannungsrichtlinie
EMV – Elektromagnetische Verträglichkeit
RoHS – Beschränkung der Verwendung bestimmter gefährlicher
Stoe
RED – Funkanlagenrichtlinie
Angewandte Normen und Zulassungen
Gemäß folgenden Normen:
EN60730-1, EN60730-2-9, EN300328, EN301489-17,
EN301489-1, EN62479, EN 50559
Klassifikation
Schutz vor elektrischem Schlag muss durch entsprechende
Installation gewährleistet sein. Entsprechende Installation muss die
Anforderungen der SchutzklasseII (verstärkte Isolierung) erfüllen.
Deutsch
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG

18
UMWELT UND RECYCLING
Schützen Sie die Umwelt und entsorgen Sie die Verpackung
gemäß den lokalen Vorschriften für Abfallverwertung.
Recycling von Altgeräten
Geräte mit diesem Aufkleber dürfen nicht mit dem
normalen Hausmüll entsorgt werden.
Sie müssen mit anderem elektrischen und elektronischen
Abfall getrennt gesammelt und gemäß den lokalen
Vorschriften entsorgt werden.
Deutsch
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG

19
TECHNISCHE DATEN
Regelungszweck Elektrische Fußbodenheizung
Art der Montage Wandmontage in Unter- oder
Aufputzdosen
Spannungsversorgung 100–240 VAC ±10% 50/60 Hz
Max. Vorsicherung 16 A
Eingebauter Schalter 2-polig, 16 A
Schutzart IP21
Leiterquerschnitt, Klemmen
Stromstärke ≤ 13 A = 1,5 mm²
eindrähtig
Stromstärke > 13 bis 16 A = 2,5 mm²
eindrähtig
ELV-Grenzen realisiert SELV 24 VDC
Ausgangsrelais Schließkontakt – SPST – NO
Ausgang, Last Max. 16 A / 3600 W
Regelprinzip PWM/PI
Standby-Leistungsaufnahme ≤0,5 W
Batterie-Backup 5 Jahre (Lagerung)
Batterielebensdauer, typisch 5 Jahre (Lagerung), 10 Jahre (Betrieb)
Funkfrequenzband* 2,4 GHz
WiFi* IEEE 802.11 b/g/n – 2,4GHz
Verschlüsselung* WPA/WPA2
Abmessungen (H x B x T) MxD5: H/84, W/84, D/40 mm
Einbautiefe 22 mm
Gewicht ≤200 g
Display 176x220 Pixel TFT – resistives
Touchdisplay
Verschmutzungsgrad 2
Überspannungskategorie III
Aktionstyp 1.B
Software-Klasse A
Nennimpulsspannung 4kV
Temperatur Kugeldruckprüfung (TB) 125°C
EU-Gebrauchsmuster DM/082270
Hinweis: Bei sehr niedrigen Temperaturen kann das Display langsam reagieren.
* Nur gültig für WiFi-Touch-Thermostate
Deutsch
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG
© 2020. Alle Rechte vorbehalten. Verwendet unter Lizenz von Schlüter-Systems KG

20
DH E RT2 / BW
(MCD5-1999-SLP3)
DH E RT5 / BW
(MWD5-1999-SLP3)
© 2020. Tous droits réservés. Utilisé sous licence par Schlüter-Systems KG© 2020. Tous droits réservés. Utilisé sous licence par Schlüter-Systems KG
INTRODUCTION
Ce thermostat PWM/PI électronique permet de contrôler la tempé-
rature grâce à une sonde NTC externe ou interne au thermostat.
Le thermostat doit être installé dans un boîtier mural encastré. Un
socle mural est également disponible.
Fig. 1 - Contenu
• Thermostat
• Sondes
• Outil de démontage de l’écran
Ce thermostat peut servir à contrôler le chauage électrique de
locaux en vertu de la norme EN50559.
Gamme de produits
DH E RT2 / BW Thermostat à horloge avec deux sondes:
une sonde de sol et une sonde d’ambiance
intégrée.
DH E RT5 / BW Thermostat à horloge WiFi avec deux sondes:
une sonde de sol et une sonde d’ambiance
intégrée.
CONSIGNES IMPORTANTES DE SÉCURITÉ
Fig.2 - Avertissements
Pour éviter toute électrocution, débranchez l’alimentation
électrique du système de chauage au niveau du tableau
principal avant la réalisation de travaux sur le thermostat
ou les composants associés.
L’installation doit être eectuée par un personnel habilité confor-
mément aux dispositions légales adéquates (si requis par la loi).
L’installation doit être conforme aux normes électriques locales et
nationales en vigueur.
Instructions
Français
Other manuals for DH E RT2/BW
1
This manual suits for next models
3
Table of contents
Languages:
Popular Controllers manuals by other brands

Citizen
Citizen CBM-909PC SERIES user manual

Transmitter Solutions
Transmitter Solutions PAL quick start guide

GOK
GOK FL 90-4 Assembly and operating manual

Blucave
Blucave CC-18LI-1 Original instructions

Lawler
Lawler 805 SEA Deluxe Installation & maintenance manual

Sunshine Solar
Sunshine Solar EPIPDB-COM Series instruction manual