manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Schrack Technik
  6. •
  7. Timer
  8. •
  9. Schrack Technik 1 CO User manual

Schrack Technik 1 CO User manual

This manual suits for next models

3

Other Schrack Technik Timer manuals

Schrack Technik TEMPUS ANALOG User manual

Schrack Technik

Schrack Technik TEMPUS ANALOG User manual

Schrack Technik AMPARO ZRAE0011 User manual

Schrack Technik

Schrack Technik AMPARO ZRAE0011 User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Tempus Digital BZT28371, BZT28372
Installation and operating instructions
Digital Day/Week Timer 1 CO/2 CO
Clock Operated Switch
310364 02
1. Basic safety instructions
Danger of death through electric shock or fire!
Installation should only be carried out by
professional electrician.
WARNING
• The device is designed for installation on DIN top hat rails
(in accordance with IEC/EN 60715)
• Corresponds to type 1 B actions in accordance with
IEC/EN 60730-1
Designated use
• The clock operated switch is used for lighting, ventilation,
flushing etc. applications
• Only for use in closed, dry rooms.
• Do not use on safety devices, e.g. escape route doors,
fire safety equipment etc.
Disposal
Dispose of device in environmentally sound manner
-
Res 12
AM
PM
PROG TIME DATE SU
/
WI
12 31
ESC OK


ESC
– Activate screen
– Open menu
– Cancel menu
– Leave menu
OK
– Store selection
– Confirm selection
2. Screen and keys
-
Res 12
AM
PM
PROG TIME DATE SU
/
WI
12 31
ESC OK


Display time
Display permanent
switching
Set the date
Storage location
Channel number
Channel status
ON = On
OFF = Off
Days of the week 2 dots flash:
Nominal voltage OK
3 dots flash:
Power reserve operation
Set switching times
Set time
Set summer/winter time
RESET/complete deletion
Press reset button.
All data is deleted after a reset and the device is returned
to factory settings (not preset).
BZT28371 BZT28372
3. Connection/installation
Warning, danger of death through electric
shock!
Disconnect power source.
Cover or shield any adjacent live components.
Ensure device cannot be switched on!
Check power supply is disconnected.
Earth and bypass.
WARNING
4. Overview of menu selection
PROG
CHANNEL
MEMORY
On/Off
HOUR
MINUTE
WEEK
DAY
ESC
TIME DATE
12 31
SU
/
WI
END


HOUR
MINUTE
YEAR
MONTH
DAY
– – : – –
EU
USA
CDN
...
*
* only with BZT28372
5. Initial start-up
The device is not preset. Date, day of the week (1 ... 7),
time format (12h AM/PM or 24 h) and time must be set.
Press any button and follow on-screen instructions.
(see fig.).
YEAR MONTH DAY DAY OF
THE WEEK
24h or
12h
HOUR MINUTE
ESC
     

Select digit for day of the week: Presetting e.g.
Monday = 1; depending on country: Sunday = 1, Saturday = 1 1
+
-
Res
N
L
12
AM
PM
PROG TIME DATE
SU
/
WI
12 31
R3a-20T
220-230V~
50-60Hz
ESC OK
4
C2 56
µ
1
C1 23
µ
16-12
AWG
M
+
-
Res
N
L
AM
PM
PROG TIME DATE
SU
/
WI
12 31
ESC OK
16-12
AWG
M
L
+
Res
N
L
12
ESC OK
M
+
Res
N
L
ESC OK
M
L
L
SIMPLEXA 601
SIMPLEXA 602
BTZ28371
N
L1
L2
N
L1
L2
R3a-20T
220-230V~
50-60Hz
R3a-20T
220-230V~
50-60Hz
R3a-20T
220-230V~
50-60Hz
4
C2 56
µ
1
C1 23
µ
123
µ
1
C1 23
µ
L L
R6a-20T
220-230V~
50-60Hz
R6a-20T
220-230V~
50-60Hz
4
C2 56
µ
C
6010001
16(6)A 250 VacC
6020001
-
-
16(6)A 250 V~
16(6)A 250 V~
BTZ28372
16(6)A 250 V~
+
-
Res
N
L
12
AM
PM
PROG TIME DATE
SU
/
WI
12 31
R3a-20T
220-230V~
50-60Hz
ESC OK
4
C2 56
µ
1
C1 23
µ
16-12
AWG
M
+
-
Res
N
L
AM
PM
PROG TIME DATE
SU
/
WI
12 31
ESC OK
16-12
AWG
M
L
+
Res
N
L
12
ESC OK
M
+
Res
N
L
ESC OK
M
L
L
SIMPLEXA 601
SIMPLEXA 602
BTZ28371
N
L1
L2
N
L1
L2
R3a-20T
220-230V~
50-60Hz
R3a-20T
220-230V~
50-60Hz
R3a-20T
220-230V~
50-60Hz
4
C2 56
µ
1
C1 23
µ
123
µ
1
C1 23
µ
L L
R6a-20T
220-230V~
50-60Hz
R6a-20T
220-230V~
50-60Hz
4
C2 56
µ
C
6010001
16(6)A 250 VacC
6020001
-
-
16(6)A 250 V~
16(6)A 250 V~
BTZ28372
16(6)A 250 V~
2
6. Switching times
6.2 Request switching times
Request switching times by using + or – buttons.
6.1 Set switching times
6.3 Change /delete switching times
Change switching times:
Confirm stored switching time by pressing the OK button.
Press OK button again once, use + or – button to change
hour/minute.
Confirm with OK button.
Delete switching time:
Confirm stored switching time by pressing the OK button.
Press + or – button; it appears
Confirm with OK button.
7. Summer/winter time
8. Set manual permanent switching
The permanent switching (PERMANENT ON, PERMANENT
OFF) can be selected for each channel via direct operation
of buttons.
BZT28371: Press + and – buttons simultaneously
(
-
Res 12
AM
PM
PROG TIME DATE
SU
/
WI
12 31
ESC OK


appears)
BZT28372: for C1: Press + and – buttons
for C2: Press + and OK buttons
Press button continually until the required status is displayed
(PERMANENT ON, PERMANENT OFF, no permanent
switching).
There are 28 available memory locations per channel.
PROG
C1/C2*1 C1
– – : -- –
1 C1 On
– – : -- –
HOURS
MINUTES WEEK
DAYS
2 C1
– – : -- –
OK OK OK OK
OK OK
OK
  




memory location
Selection of days of the week/blocks:
Days 1-7; 1-5; 6-7; 1-6; or all days individually
set additional switching time
SU
/
WI
ESC
SU
/
WI
C1 On
11:28

– – -- –
EU
USA
...
OK
PROG
Summer/winter time rules
– – – – no rule
EU rule for the EU
USA USA
CDN Canada
IL Israel
NZ New Zealand
IRAN Iran
FREE free rule
DATE fixed date
END C1 Off
11:28
OK
+
7.1 Set summer/winter time
Press ESC button and using the + or – buttons select
SU/WI menu.
Press OK button and using the + or – buttons select
the relevant rule (see table).
7.2 Set free rule (FREE)
1. Change to summer time
Enter month, week in month (5 = last week), day of the
week, changeover time consecutively
2. Change to winter time
Enter month, week in month
* only with BZT28372
1 C1 On
– – : -- –
1 2 3 4 5 6 7
9. Technical data
• Rated voltage: 220–230 V~
+10 %/-15 %
• Frequency: 50–60 Hz
• Power consumption: typically 4,5 VA
• Contact: floating
• Contact material: AgSnO2
• Switching capacity: 16 (6) A, 250 V~
• Power reserve: 6 years at 20 °C
• Incandescent lamp load: 1400 W
• Halogen lamp load: 1400 W
• Fluorescent lamp
uncorrected: 1400 VA
series-corrected: 1400 VA
parallel-corrected: 220 VA (24mF)
• Compact fluorescent 13 x 7 W, 13 x 11 W,
tubes: 10 x 15 W, 8 x 23 W
• Permissible ambient-
temperature: –20 °C ... +55 °C
• Protection class: II in accordance with IEC/EN 60730-1
with designated installation
• Degree of protection: IP 20 in accordance with IEC/EN 60529
Schrack Technik GmbH
www.schrack.com