SCOPREGA BRAVO TURBO-MAX KIT DRIVER User manual

BRAVO TURBOMAX KIT DRIVER 1
BRAVO TURBO-MAX KIT
DRIVER
INSTRUCTION MANUAL
Catalog Number
TURBO MAX DC DRIVER 6130075
VE
THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE.
WARNING: READ THE TURBOMAX KIT MANUAL BEFORE OPERATING THE PRODUCT
SAVE THIS INSTRUCTION MANUAL FOR REFERENCE

BRAVO TURBOMAX KIT DRIVER 2
SAVE THESE INSTRUCTIONS
The content in this manual has been carefully prepared and is believed to be accurate, but no responsibility is assumed
for inaccuracies. Scoprega reserves the right to make changes without further notice to any products herein to improve
reliability, function or design. Scoprega does not assume any liability arising out of the application or use of any product
or circuit described herein; neither does it convey any license under its patent rights of others.
WARNINGS:
1. Read these instructions.
2. Keep these instructions.
3. Follow all instructions.
4. Install in accordance with the manuafacturerʼs instructions.
5. Do not exchange polarized DC Power Supply Terminals.
6. Protect the cord from being walked on or pinched.
7. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way.
8. Do not disassemble the product. Incorrect reassembly may result in a risk of Short Circuit.
9. Provide adequate ventilation and refrain from placing items on or around the product during operation.
DO NOT SUPPLY THE DC DRIVE HIGHER VOLTAGE THAN 31 VDC
GENERAL SAFETY RULES
1. CONSIDER WORK AREA ENVIRONMENT. Donʼt expose the drive to rain. Donʼt use it in presence of flammable liquids or
gases.
2. DONʼT ABUSE CORD. Keep cord from heat, oil, and sharp edges.
3. WARNING! RISK OF UNSAFE OPERATION. Do not modify or attempt to repair. Never drill into or make any modifications to
the DRIVE.
4. WARNING! RISK OF FIRE. Allow the DRIVE to cool 20 minutes if operated for more than 30 minutes.
INTRODUCTION
The TURBOMAX KIT DRIVER is a digital DC servo- drive developed with DSP and high efficient MOSFET technologies controlled
by a microprocessor. It is able to control a Brush DC motor pair in terms of speed (velocity control) and current independently from
input voltage.
THE DRIVE MUST BE USED IN CONJUNCTION WITH A TURBOMAX KIT 24VDC AIR STATION ONLY.
DO NOT SUPPLY THE DC DRIVE HIGHER VOLTAGE THAN 31 VDC.
FEATURES
Input Voltage: 21-31 VDC
Input Current: 25 A (Cont.), 30 A (Peak),
Control technology: PWM based on DSP and high smooth servo control algorithm.
Motor Feedback: Armature Voltage

BRAVO TURBOMAX KIT DRIVER 3
MECHANICAL SPECIFICATIONS
INSTALLATION REQUIREMENTS
Driver’s reliable working temperature shall be LESS than 50°C
Avoid dust, oil fog and corrosive gases
Storage Temperature -20°C; 65°C
Weight Approx. 250 g
BEFORE CONNECTING THE DRIVE MAKE SURE THAT THE INPUT LINE IS NOT LIVE (NO POWER) CONNECTIONS
WITH LIVE POWER CAN DAMAGE THE DRIVER
CONNECT THE “LINE IN”CONNECTOR TO THE ELECTRICAL SISTEM
CONNECT THE “POWER OUT”CONNECTOR TO THE TURBOMAX
TURN ON THE POWER
CHECK THAT THE GREEN LED IS ON
OPERATE THE TURBOMAX AS PER TURBOMAX AIR STATION MANUAL
USE of TURBOMAX DRIVER
WARNING: Make sure polarity is correct (Red to Positive). With wrong polarity the Inflator WILL NOT START
WARNING: Exercise with care when connecting the cord to batteries in order not to short the battery with conducting
materials such as rings, bracelets and keys. The battery or conductor may overheat and cause burns.
WARNING: Check the proper Power Voltage. Do not operate below 21Vdc or above 31 Vdc
Always fully extend the 12/24 Vdc cord before each use.
Set the Pressure Knob to the desired limit. WHEN DEFLATING SET TO 175 mbar.
Press the Main Switch to ON
Press the Start Switch to START
The inflator will stop automatically when the inflatable reaches the set value
WARNING: Do not leave the unit running unattended. Over-inflation of items could result in serious injury.
LINE IN
POWER OUT
130 mm
94 mm
B
B
View from arrow B
30
45 mm
FUSE POWER ON FAULT
LINE IN POWER OUT

BRAVO TURBOMAX KIT DRIVER 4
TROUBLESHOOTING
Problem
Possible Cause
Possible Solution
Unit will not Start
24 Volt cord not properly connected
Connect the Power Supply. Make sure polarity is correct (Red to
Positive; Black to Negative pole)
Power supply not live
Check the GREEN LED
Main ON/OFF switch not ON
Turn main switch to ON
The Safety Fuse is blown
Replace the fuse with one of the same size (30 A)
Cord or connectors are damaged
Have switch replaced by BRAVO Service Center
The DC Driver Fuse is blown
Replace the fuse with one of the same size (40 A)
GREEN LED OFF
Power Supply not present
Connect properly to the Electrical System
The Safety Fuse is blown
Replace the fuse of the DC Driver
RED LED SLOW
FLASHING
The Input voltage is below 21 Vdc
Check the Electrical System
RED LED FAST
FLASHING
The Input voltage is above 31 Vdc
Check the Electrical System
RED LED SOLID ON
Over- temperature
Wait for cooling till the red light goes off
Microcontroller in Stand-By
Disconnect and reconnect the PWR supply connector to reset
the unit.
Will not inflate/deflate
Wrong Port connected
Connect the air hose to the proper Port (IN to deflate; OUT to
inflate.
Wrong setting on the Pressure knob
Adjust settings
Main ON/OFF switch not ON
Turn main switch to ON and then press START
ACCESSORIES
Recommended accessories for use with your inflator are available from your local dealer or authorized service center.
WARNING: The use of any accessory not recommended for use with this inflator could be hazardous.
.
This manual suits for next models
1