GEMINI
2
GEMINI can be used with Powerpak,
TORNADO or Proflow powered
respirator systems provided that the
correct filter type is fitted.
In such cases, ensure that this manual is
read in conjunction with the following
publications:
Product Publication Article No.
Powerpak User Manual 1065558
Filter Manual 1064883
Tornado User Manual 1070613
Filter Manual 1070782
Proflow User Manual 009741
Filter Manual 009752
Please contact our Customer Services
Department if you require any further
information.
GEMINI is easily dismantled for repair
and servicing. However, please note that
servicing should only be carried out by
trained, authorised personnel.
FILTERS
The following filters are available for use
with GEMINI:
Code Filter Type Standard
EC200R A2 EN 14387 : 2004
EC201R B2 EN 14387 : 2004
EC203R K2 EN 14387 : 2004
EC213R ABEK2 EN 14387 : 2004
EC219R AX EN 14387 : 2004
EC220R A2 P3 EN 14387 : 2004
EC221R B2 P3 EN 14387 : 2004
EC222R E2 P3 EN 14387 : 2004
EC223R K2 P3 EN 14387 : 2004
EC230R A2 B2 E1 P3 EN 14387 : 2004
EC233R ABEK2 P3 EN 14387 : 2004
EC238R AE1Hg P3 EN 14387 : 2004
EC239R AXP3 EN 14387 : 2004
EC251R P3 EN 143 : 2000
WEARING
1. Ensure that the facemask is clean
and undamaged, paying particular
attention to the inhale and exhale valves;
and head harness.
2. Ensure that the inhale valve frame
is present, in good condition and correctly
seated in the front fitting. Replace if
necessary.
3. Check that the filter intended for
use is not clogged, saturated or time-
expired and is suitable for the hazards
that may be encountered. Fit a new filter if
necessary.
4. Ensure that the filter is securely
fitted to the mask.
5. Ensure that the visor is clear and
free from scratches or other abrasions
which could impair vision.
6. Hang the mask around your neck
by the neckstrap, fully slacken the head
harness and remove the filter cover.
7. Hold the head harness with the
thumbs inside the harness. Fit the chin
into the chin-cup and pull the harness
over the head. Gently tighten the harness
straps; lower first, then middle and finally
the top strap. A good seal should be
achieved without over-tightening, which
will distort the faceseal and cause
discomfort to the wearer.
8. Check the mask seal to the face by
covering the filter inlet with a hand or the
filter blanking cover and inhaling. The
mask should pull onto the face. Hold your
breath for 10 seconds and check that the
mask seal is maintained over the 10
second period. If the seal fails, indicated
by the mask pulling away from the face,
check that the filter is properly fitted and
adjust the mask seal to the face, then
repeat the test. If it fails a second time,
the mask should be serviced.
WARNING:
If the mask does not seal correctly
after servicing, DO NOT use.