manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SDI
  6. •
  7. Measuring Instrument
  8. •
  9. SDI db checker User manual

SDI db checker User manual

dbchecker
TM
Sound Level Meter
 Ideal for maintenance of fire and security alarm systems
 Easy to use
 Unit conforms to the IEC651 type 2, ANSI S1.4 Type 2
(Required by NFPA 72 Chapter 14, 14.4.2.2.(15))
 Designed to meet the requirements of Life Safety Engineers
 Range from 32dB to 130 dB at frequencies between
31.5Hz and 8 KHz
 Display with 01.dB steps on a 4-digit LCD
 Two equivalent weighted sound pressure levels, A and C
AC Signal output available
is ideal for testing audible appliances for the
public operating mode of an emergency voice/alarm system
in accordance with manufacturers instructions.
dbchecker
TM
INSTRUCTIONS
Open battery cover and install a 9V battery in the battery
compartment.
Turn power ON and select the desired response time and
weighting. If the sound source consists of short bursts or
only catching sound peak, set response to FAST. To
measure average sound level, use the SLOW setting.
Select desired Level.
Hold the instrument comfortably in hand and point the
microphone at the suspected noise source, the sound
pressure level will be displayed.
When MAX/MIN ( maximum, minimum hold ) mode is
chosen. The instrument captures and holds the maximum
noise level for a long period using any of the time
weightings and ranges.
Press the MAX/MIN button 2 seconds to clear the
MAX/MIN reading. “MAX/MIN” symbol disappears.
Turn OFF the instrument.
(1)
(2)
(3)
(4)
(5)
(6)
SPECIFICATIONS
Standard Applied: IEC651 Type2, ANSI S1.4 Type2.
31.5Hz to 8KHzFrequency Range:
32dB to 130dBMeasuring Level Range:
A / CFrequency Weighting:
½ inch electrical condenser microphoneMicrophone:
LCDDisplay:
4 digitDigital Display:
0.1dBResolution:
0.5 sec.Display Update:
FAST ( 125mS ), SLOW ( 1 sec. )Time Weighting:
Lo: 32 dB to 80 dBLevel Ranges:
Med: 50 dB to 100 dB
Hi: 80 dB to 130 dB
Accuracy:
±1.5dB ( under reference conditions, 94dB@1kHz )
50 dBDynamic Range:
“OVER” is when the input is more than upper Alarm Function:
limit of range.
“UNDER” is when input is less than lower limit of range.
MAX / MIN Hold:
Hold readings the Maximum and Minimum Value.
1 Vms at FS ( full scale ).AC Output:
Output impedence: Approx 100 Ohms
FS: means the upper limit of each level range.
Power Supply:
One 9V battery, 006P or IEC 6F22 or NEDA 1604.
Approximately 70hours ( Alkaline Battery )Power Life:
0 to 40°C ( 32 to 104°F )Operation Temperature:
Operation Humidity: 10 to 75%RH
9.1” L x 2.1” W x 1.3” HDimensions:
23.1 cm x 5.3 cm x 3.3 cm
.75 lbs (.34kg) (including battery)Weight:
9V battery, screwdriver, instruction manual and Accessories:
windscreen.
WHY dBchecker?
Merely "listening" or utilizing any sound level meter available is not a
reliable method for testing audible alarm notification appliances. Many
of the meters currently on the market do not meet the requirements for
NFPA 72. dBchecker™ conforms to ANSI S1.4a, which is required to
meet the standard set forth in the latest edition of the National Fire
Alarm Code. (NFPA 72)
HIGHEST STANDARDS
" ….only sound level meters that comply with ANSI S1.42 should be
used for the assessment of fore alarm systems…"
" …Testing of Audible Alarm Notification Appliances shall be done upon
initial acceptance and semi-annually"
" …Sound pressure shall be measured with sound level meter meeting
ANSI S1.4a, Specifications for Sound Level Meters, Type 2
Requirements. Levels throughout the protected area shall be
measured and recorded…." NFPA 72 14.4.2.2 (15)
CAN/ULC S536-04, G1.1
" The sound level meter shall have a measurement range that permits
readings as low as 35 dBA..." "The use of a quality meter to minimize
any measurement errors. ANSI S1.40, Specifications for Acoustic
Calibrators, is one standard that can provide guidance on the subject."
LN, Oct
LT, Oct
Fire Alarm
Frequency (Hz)
10 100 1000 10,000
35
40
45
50
55
60
65
70
75
Sound Pressure Level (dB)
LI32187-4
ALSO AVAILABLE FROM SDi
 Professional Smoke Detector Testers
with approved and listed dispensers
 Genuine Professional Heat Detector Testers
suitable for fixed temperature, rate of rise and combined detectors
 CO Detector Testers
with approved and listed dispenser
 Aerosol Dispensing Tools
as recommended by detector manufacturers
 Detector Removal Tools
suitable for all leading makes and model of detector
 Access Poles
to enable detector maintenance up to 30+ ft.
 Complete Maintenance and Service
providing complete solutions in economical and convenient kit formats
 Smoke Detector Sensitivity Instruments
to identify sensitivity drift and help ensure that smoke detector sensitivity is
maintained within defined calibration parameters
SDi,
1345 Campus Parkway, Neptune, NJ 07753-6815 USA
Tel: 732-751-9266 Fax: 732-751-9241
Email: [email protected] Web: www.sdifire.com
Specialized Fire Products

Other SDI Measuring Instrument manuals

SDI PORTAGAUGE 4 User manual

SDI

SDI PORTAGAUGE 4 User manual

SDI ductchecker 8252 User manual

SDI

SDI ductchecker 8252 User manual

SDI Solo 365 User manual

SDI

SDI Solo 365 User manual

SDI DB01 User manual

SDI

SDI DB01 User manual

SDI NMSC-2 User manual

SDI

SDI NMSC-2 User manual

Popular Measuring Instrument manuals by other brands

Amprobe TDR-400 manual

Amprobe

Amprobe TDR-400 manual

TPI 709R instruction manual

TPI

TPI 709R instruction manual

Hantek HT300B quick start guide

Hantek

Hantek HT300B quick start guide

Kanomax ANEMOMASTER Series Operation manual

Kanomax

Kanomax ANEMOMASTER Series Operation manual

RaySafe x2 user manual

RaySafe

RaySafe x2 user manual

Radiodetection 1205CXA Operator's manual

Radiodetection

Radiodetection 1205CXA Operator's manual

TESTO 330-1G instruction manual

TESTO

TESTO 330-1G instruction manual

Eurochron 1544543 quick guide

Eurochron

Eurochron 1544543 quick guide

FRIENDCOM PULSE915-LRW Configuration guide

FRIENDCOM

FRIENDCOM PULSE915-LRW Configuration guide

Agilent Technologies ICP-MS Series Troubleshooting

Agilent Technologies

Agilent Technologies ICP-MS Series Troubleshooting

Vernier Go Direct Mini GC quick start guide

Vernier

Vernier Go Direct Mini GC quick start guide

Laser Technology UltraLyte user manual

Laser Technology

Laser Technology UltraLyte user manual

National Instruments PXIe-5632 Getting started guide

National Instruments

National Instruments PXIe-5632 Getting started guide

Amprobe ACD-51HP user manual

Amprobe

Amprobe ACD-51HP user manual

Emerson Rosemount Oxymitter DR Reference manual

Emerson

Emerson Rosemount Oxymitter DR Reference manual

Endress+Hauser Levelflex FMP51 operating instructions

Endress+Hauser

Endress+Hauser Levelflex FMP51 operating instructions

Conrad 67 25 06 operating instructions

Conrad

Conrad 67 25 06 operating instructions

Major tech MT920 instruction manual

Major tech

Major tech MT920 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.