3.ClosingtheUW-housing:
Pullouttheshaftfortherearadjustmentwheel,settheBKTflashswitchto
theOKposition(whitemarkpointingtofront).Pulloutthesegmentcontrol
leverandsetittothesinglesegmentposition.
Setthecameraswitchtothisposition,too.
MakesuretheO-ringiscleanandproperlyembeddedintheO-ringgroove.
TheO-ringshouldbelubricatedonlylightlywithsiliconegrease.
Gentlyplacetherearpartofthehousingontothefrontpart,thebackcoveris
automaticallycentredontothefrontguide.
Hookinandsimultaneouslysnapshutbothlockingdevices.
Nowcheckthatbothlockingdeviceshaveproperlysnappedintoplace.
Pushtheshaftfortherearadjustmentwheelandsegmentcontrolbackintothe
housingandcheckitsfunction.Byliftingthesegmentcontrolshaft,theyokecan
beputintoitscorrectpositionevenafterthesesteps.
Nowcheckfunctionsonbackcover.
Toopenpushinlockingdevicesandproceedinreverseorder.
4.Howtochangea port:
Matchupportwithbayonetmountonhousing:theredmarkontheportmust
pointupwards.Gentlyandevenlypushtheportontothemountuntilitreachesa
stop.Turnanticlockwiseuntilthewhitemarkpointsupwards.Protectfrontlenswit
cap.
5.Housingmaintenance:
Aftereachuseintheseaorinfreshwaterthehousingshouldbebrieflyrinsedoff
infreshwater,pressingfunctionskeysandoperatingleversatthesametime.
CleanhousingO-ringandportO-ringregularly.ForthispurposepushtheO-ring
onthelongsideofthehousingsothata loopisformed.CleantheO-ringaswell
asthegrooveandthejointfacewitha cleanandlint-freerag,lightlylubricate
withsiliconegreaseandreplaceO-rings.
Ifthehousingisstoredawayfora longerperiodoftime,theO-ringsshouldbe
removedfromthehousinggrooveandtheportandleftinsidethehousing.Aftera
fewdaysthehousingshouldbelightlysprayedwitha specialaluminiumcleaner
(provided)andrubbedinwitha rag.
After2 yearsor200diveswerecommendsendinginthehousingfora general
inspection.
SEALUX- The easy way to top quality underwater photograph