Sealy Posturepedic Reflexion-4 IC-ABF-A18-WWM-U-W User manual

The Reflexion®
-4 Adjustable Base
OWNER’S MANUAL
The Reflextion®
-4 base can be used in conjunction with
both Sealy-Posturepedic and Optimum mattresses.


1
Safety Precautions
Parts List
Installation Guide
Using the Remote Control
Programming the Remote Control
Lowering the Bed in a Power Outage
Troubleshooting
Warranty
2
4
6
8
10
11
12
14
TABLE OF CONTENTS
The Reflexion®
-4 Adjustable Base
Model Number: IC-ABF-A18-WWM-U-W

2
ATTENTION!
IMPORTANT SAFETY INSTRUCTIONS.
PLEASE READ THESE INSTRUCTIONS
THOROUGHLY BEFORE USING
THIS PRODUCT.
ELECTRICAL SAFETY
Always unplug this Adjustable Base from
the electrical outlet before any cleaning or
maintenance of the bed frame. To safely
disconnect, make sure all controls are in the o
position, then remove the plug from the outlet.
Keep cord away from heated surfaces. Keep air
openings free of lint, hair and the like —never
operate when air openings are blocked. Never
drop or insert any object into any opening.
Use only indoors.
Cease use of this bed frame and contact
a qualified service center for repair if:
• It has a damaged cord or plug
• It is not working properly
• It has been dropped or damaged
• It has been dropped into water
GROUNDING SAFETY
To reduce the risk of electric shock, electrical
fire, or faulty operation of this product, your
Adjustable Base features a polarized plug meant
to be used only with a grounded electrical outlet.
If this plug does not fit into your outlet, contact a
qualified electrician to install a properly grounded
outlet. Failure to use a properly grounded outlet
for this product will compromise this important
grounding safety feature. The use of adapters is
not recommended unless the outlet is checked
by a qualified electrician to ensure the proper
grounding of the adapter.
WARRANTY WARNING!
This Adjustable Base is specifically designed to
require no maintenance by you, the user. Any
opening or tampering with the control box,
motors or hand controls (with the exception of
the battery compartment, if equipped) will result
in a void of the warranty. Only those authorized
may conduct repairs or part replacement on
your Adjustable Base.
NOTE:
Unauthorized modifications to this product could
void the electrical portion of your warranty.
NOTE:
For optimal safety, your Adjustable Base should be
plugged into a surge protector (not supplied with
this Adjustable Base).
INHOME USE ONLY
This Adjustable Base is designed exclusively for
in-home use.
IMPORTANT SAFETY FEATURES
Weight Fail Safe Feature — In the case that an
overload of weight is placed on the head or foot
mechanism, the control unit will automatically
stop all functions. The control unit will
automatically resume all functions 30 seconds
after excess weight is removed.
Locking Caster Feature — This Adjustable Base
may be equipped with special locking casters.
For your safety, these casters will prevent bed
movement when all casters are in the locked
position. To lock casters, push down the safety
latch on the caster. To resume product mobility,
lift the safety latch up.
HOSPITAL DISCLAIMER:
It is NOT designed for hospital use and is NOT
designed to meet hospital standards. Do not use this
bed with TENT TYPE oxygen therapy equipment or
use near explosive gases.
NOTE:
If your Adjustable Base is positioned on a hard
floor surface such as hardwood or tile, it is strongly
recommended that rubber caster cups or carpet
squares are placed under the casters in addition to
locking them in place. Casters will not roll when
locked, but may slide on an uncarpeted surface.
Safety Precautions

3
CONSUMERS WITH PACEMAKERS
It is possible that the (optional) vibrating feature
of this bed may be interpreted falsely by some
pacemakers as movement and/or exercise. This
is common with any product that produces a
vibrating motion, and may or may not aect your
pacemaker. Please consult your physician with
any concerns.
RADIO FREQUENCY IS 433.92 MHZ
FCC compliance device complies with part 15
of the FCC Rules. Operation is subject to the
following two conditions:
1 This device may not cause harmful
interference
2 This device must accept any interference
received, including interference that may cause
undesired operation
Any change to the antenna or the device could
result in the device exceeding the RF exposure
requirements and void user’s right to operate
the device.
The input transformer voltage is AC120V 60HZ;
the output voltage is DC24V 3A. In the case of a
short-circuit, a fuse on the transformer will blow
to protect the electrical equipment of the device
(Fuse: 1A~1.5A). Should this occur, you should
seek professional assistance to fix the problem,
and call Customer Care at: 1-800-499-1965.
PRODUCT RATINGS
Lift Motor Restrictions — The lift motors in this
bed are NOT designed to operate continuously
for more than 3 minutes over a 30 minute time
period, or approximately 10% duty cycle. To
ensure reliable functionality and full life of this
product, do not attempt to exceed these limits.
Weight Restrictions — The recommended weight
limits on our Adjustable Bases are:
• Twin /Twin Extra Long /Split Queen /
Split CA King: 575 pounds
• Full /Full Extra Long: 600 pounds
• Queen: 650 pounds
The structure of the bed will support the
recommended weight when distributed
evenly across the bed. Maximum weight the
bed can support per person is 250 pounds.
The head and foot sections are not designed
to individually support or lift this amount
of weight. For optimal performance, entering
and exiting the Adjustable Base with the bed in
the flat or level position is recommended.
NOTE:
Attempting to circumvent or exceed this rating will
shorten the life expectancy of the product and may
void the warranty.
NOTE:
Exceeding the recommended weight restrictions
could damage your Adjustable Base and void
your warranty.
SMALL CHILDREN AND PETS
WARNING
Immediately dispose of all packing materials
as it can pose a smother risk to small children
and pets. Injury could occur also if children or
pets are permitted to play on or under the bed.
Do not allow children to operate this bed without
adult supervision.
SAVE THESE INSTRUCTIONS!
Proper operation of your Adjustable Base is
necessary to ensure the long life and durability
you expect from a high-quality product. The
manufacturer has tested and inspected this
product prior to shipment.

4
Parts List
Before discarding any packing materials,
check the Adjustable Base carton
and verify all items in the parts list
are included.
* Indicates part is attached to base for shipping purposes.
** These items are not included. These are optional HBD brackets and parts that can be purchased from your
supplier or distributor.
REMOTE CONTROL (1)
BED LEG (4)
MATTRESS RETAINER BRACKET (1) *
INNER HEADBOARD BRACKET (2) **
OUTER HEADBOARD BRACKET (2) **

5
* Indicates part is attached to base for shipping purposes.
** These items are not included. These are optional HBD brackets and parts that can be purchased from your
supplier or distributor.
RETAINER BOLT (4) *1/4 INCH RETAINER WASHER (2) * ALLEN KEY WRENCH (1)
HEADBOARD BRACKET BOLT (6) **5/16 INCH WASHER (12) ** WRENCH (1) **
5/16 INCH NUT (6) **

6
Installation Guide
STEP 1
For safety reasons, the following should be
performed by 2 people. Carefully lift the bed
frame unit out of the shipping carton with the
top side facing downward.
STEP 2: ASSEMBLE THE BED LEGS
For this step, you will need 4 bed legs (C), which
can be found in the accessories box. Turn each
bed leg (C) in a clockwise direction into the
threaded holes on the frame as shown. Repeat
the bed leg assembly for all 4 legs (C) provided.
DO NOT OVERTIGHTEN THE BED LEGS.
NOTE:
Bed may be equipped with special locking casters
(sold separately). To prevent movement of this
product, all casters should be in the locked position.
It is recommended that rubber caster cups or
carpet squares (not included) are placed under
casters in addition to locking them in place. Casters
will not roll when locked, but may slide on an
uncarpeted surface.
STEP 3
Remove and extend the power cord from
the frame.
STEP 4
Take plastic wrapping o the base frame.
STEP 5
Carefully rotate the base frame over so the top side
is facing upward.
STEP 6
Plug the power cord into a grounded
electrical outlet.
STEP 7
Install batteries in remote control.
Test all functions on the remote control to ensure
all features are operational.
IMPORTANT!
MAKE SURE POWER CORDS DO NOT OBSTRUCT
ANY ADJUSTABLE BASE MECHANISMS.
NOTE:
Be careful not to rest the frame on its side. The weight
may damage the legs.
NOTE:
For optimal safety, a surge protector should be used
(not supplied with this Adjustable Base).
If the bed does not work, refer to Troubleshooting
on page 12.
STEP 8
Return bed to flat or level position.
STEP 9: ASSEMBLE THE MATTRESS
RETAINER BRACKET
Fasten the mattress retainer bracket (B) to the
front of the bed frame using the retainer bolts (F)
and 1/4 inch retainer washers (H), as shown in
the diagram below.
NOTE:
Use ONLY the allen wrench to fasten the retainer
bolts. DO NOT use a power screwdriver as it may
overtighten the bolts. Mattress retainer hardware
must NOT be overtightened.
NOTE:
If a headboard is to be installed, owners who have
purchased the optional HBD bracket kit continue
on to step 10. If the Adjustable Base is to be set up
without a headboard, proceed to step 11.

7
IMPORTANT!
FAILURE TO FOLLOW THE INSTALLATION STEPS
AS THEY APPEAR IN THIS GUIDE COULD RESULT IN
DAMAGE TO YOUR ADJUSTABLE BASE.
MAKE SURE TO POSITION THE BOTTOM OF THE
HEADBOARD CROSS MEMBER NO MORE THAN
3 INCHES 76.2 MM BETWEEN THE HEADBOARD
AND THE TOP OF THE MATTRESS.
STEP 10: ASSEMBLE THE HEADBOARD
BRACKET SOLD SEPARATELY
Use the hand control to elevate the head of the
bed so the bed base frame is reachable.
A
Slide the inner headboard bracket (D) horizontally
with the “C” opening facing down under the
crossbar. Position the bracket (D) in the guide peg
on the bottom of the crossbar. Insert a headboard
bolt (G) fitted with a 5/16 inch washer (I) through
the pre-drilled hole in the crossbar and into the
pre-drilled slotted hole in the “C” channel inner
headboard bracket. Tighten in place with a
5/16 inch washer (I) and 5/16 inch nut (J). Repeat
on the other side.
B
Place the open side of the outer headboard
bracket (E) onto the exposed square tube of the
inner headboard bracket (D) to create a tight fit
between (D) and (E). Insert a retainer bolt (G)
fitted with a 5/16 inch washer (I) into the outer
headboard bracket (E) and through the inner
headboard bracket (D). Hand tighten using a
5/16 inch washer (I) and a 5/16 inch nut (J).
(Leave loose enough for adjusting.) Repeat on
the other side.
C
When headboard brackets are assembled, make
sure there is a space of 1.5 to 2 inches (38.1 to
50.8 mm) between the edge of the bed base and
the headboard brackets.
D
Securely fasten the headboard bolts (not included
with your Adjustable Base) to the end of the
headboard bracket assembly.
E
Measure the distance from the center of one
mounting hole in the headboard to the center of
the other.
F
Measure the distance from the center of one
mounting hole in the headboard bracket
assembly to the center of the other.
G
If you need to adjust the headboard brackets,
unscrew the bolts holding the outer headboard
brackets and move them the necessary distance.
Reinstall the bolts and securely tighten.
STEP 11
Place your mattress on the Adjustable Base
surface. Installation is now complete.
If the bed comes with a programming option,
turn to Using the Remote Control on page 8
to proceed.

8
Using the Remote Control
LED Signature LightA: Under Bed Light
(on back of Remote)
B: Raises the Head
of the Bed
I: Increases the Intensity
of Vibration (Head)
D: Raises the Foot
of the Bed
K: Increases the Intensity
of Vibration (Foot)
C: Lowers the Head
of the Bed
M: Stops Massage
J: Decreases the Intensity
of Vibration (Head)
F: Returns Head and
Foot to Flat Position
(hold 3 seconds)
E: Lowers the Foot
of the Bed
N: Turns on Massage Wave
1, 2 or 3
L: Decreases the Intensity
of Vibration (Foot)
G: Pre-Programmed
Memory Positions
H: Full Body Massage
IMPORTANT!
FOR YOUR SAFETY, READ THE OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE OPERATING THIS
PRODUCT. ELECTRIC SHOCK MAY OCCUR IF ELECTRICAL COMPONENTS ARE NOT INSTALLED OR OPERATED
ACCORDING TO THESE GUIDELINES.
UNDER BED LIGHT A
Press the button to turn on or o the under bed
light. (button on back of remote control)
HEAD AND FOOT POSITION
ADJUSTMENTS B, C, D, E
Use to raise or lower the head and foot
sections of your Adjustable Base. The premium
“Wall-Glide” feature will automatically
synchronize with all head and foot adjustments.
BED “FLAT” BUTTON F
Press down and hold for 3 seconds to return bed
to the flat position.
PREPROGRAMMED MEMORY
POSITION G
These 3 program function keys allow you to
select the most popular positions with 1 touch.
FULL BODY MASSAGE H
Press to activate both the head and foot
massages at the same time.
HEAD AND FOOT MASSAGE
ADJUSTMENTS I, J, K, L
Use to activate the massage feature on the head
and foot of the bed (starting at intensity 4 of 8).
Gradually increase or decrease intensity of
massage vibration by pressing the appropriate
button. The lowest setting on each massage
unit will turn o the respective vibration.

9
• It is not necessary to face the receiver to
operate the remote control. Remote signal is
best transmitted within 9 feet (3 meters) of
the receiver.
SAFETY
• In the case that an overload of weight is placed
on the head or foot mechanism, the control
unit will automatically stop all functions.
The control unit will automatically resume
all functions 30 seconds after excess weight
is removed.
• Massage motors will automatically shut o
after running continuously for 15 minutes. All
massage functions will be operational again
after 5 minutes. Automatic Shut O will occur
after 15 minutes of continuous use.
• The input transformer voltage is AC120V 60HZ,
the output voltage is DC24V 3A. In the case
of a short-circuit, a fuse on the transformer
will blow to protect the electrical equipment
(Fuse: 1A~1.5A). Should this occur, you MUST
seek professional assistance to replace the fuse.
Call Customer Care at: 1-800-499-1965.
NOTE:
The changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate
the equipment.
The massage feature is programmed with an
Auto Shut-O Timer that will automatically
turn o the massage after 15 minutes of
continuous use.
STOP BUTTON M
Hold down for 2 seconds to stop massage.
WAVE MASSAGE ADJUSTMENTS N
Activates both units to wave mode massage.
REMOTE FEATURES
• The buttons are backlit, when a button is
pressed, to aid in the visibility of the remote in
low light environments.
NOTE:
You must stop massage before alternating between
massage functions.
NOTE:
You must stop the massage in order to activate
another massage setting such as full body or another
wave massage.
NOTE:
This bed may show minor intermittent performance
because of typical RF interference. This is normal in
the operation of the bed, not a defect.
NOTE:
To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the
device is permitted. Any change to the antenna or
the device could result in the device exceeding the
RF exposure requirements and void user’s authority
to operate the device.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1 This device may not cause harmful interference
2 This device must accept any interference
received, including interference that may cause
undesired operation

10
NOTE:
Programming by the user is only needed on
replacement remotes.
Programming the Remote Control
STEP 1
Insert batteries into the remote control
(2 x AA batteries).
STEP 2
Make sure your Adjustable Base is plugged into
a working grounded outlet or surge protector.
Follow steps 1 through 6 below to use the remote control with 1 power base.
To use the remote control with 2 power bases, repeat the steps for the second power
base using the same remote.
Press any button on the remote control.
When the receiver light flashes, the RF
frequency code learning process is complete.
Hold down the “Learn” button for 3 seconds
to initiate the RF learning mode.
The LED signature light will illuminate.
This means the RF frequency code setting
function has been activated.
STEP 5
STEP 6
STEP 3
STEP 4

11
NOTE:
The 2 alkaline 9 volt batteries are only rated for
single use. After the emergency lowering, replace
with new batteries.
Lowering the Bed in a Power Outage
Your Adjustable Base is equipped with an emergency lowering feature.
Follow the steps below in the event that your base is in the raised position during
a power outage.
Locate and remove the 9 volt battery cover. Replace the battery cover.
Install 2 alkaline 9 volt batteries (not included). Press either the “Flat” button (F) or the
individual lowering buttons (C, E) to lower
your bed to the level position.
STEP 1 STEP 3
STEP 2 STEP 4

12
REMOTE CONTROL LED
ILLUMINATES AND APPEARS
NORMAL, BUT WILL NOT
OPERATE BED
1 Is the power cord plugged into a working and
grounded electrical outlet?
2 Test outlet by plugging in an appliance you
know works properly.
3 Check low amp fuse on the control box under
bed. Replace fuse if blown.
NONE OF THE FUNCTIONS ON THE
ADJUSTABLE BASE WILL OPERATE
1 Re-program the remote control (as indicated
in the Manual provided with this product, for
programming procedures).
2 Unplug the power cord. After 45 seconds, plug
in to electrical outlet. This should reset the
electronic components.
3 The home electrical circuit breaker may have
been tripped. Reset circuit breaker if needed.
4 Check surge protection device or electrical
outlet to insure working order. Test outlet by
plugging in a known working appliance.
5 Check low amp fuse on control box under bed.
Replace fuse if blown.
NOTE:
A grounded, electrical surge protection device is
recommended (not supplied).
REMOTE CONTROL FUNCTION
KEYS WILL NOT ILLUMINATE
1 Replace batteries in the remote control.
2 Check that batteries are installed properly.
HEAD OR FOOT SECTION
FUNCTION KEY WILL ELEVATE
BED, BUT WILL NOT RETURN
TO THE HORIZONTAL FLAT
POSITION
1 Your bed may be obstructed preventing
smooth operation. Remove obstructions from
around and under the bed.
2 Check that head section has clearance from
headboard or wall.
3 Headboard may be too close the edge
of the mattresses. Verify a 1.5 to 2 inch
(38.1 to 50.8 mm) distance between headboard
brackets and mattress. Adjust if required.
ACTIVATING HEAD OR FOOT LIFT
FUNCTION CAUSES “PULSING”
OR “STUTTERING” WHEN
OPERATING FEATURE
1 Check batteries and installation in remote.
2 Assure that the function key is pressed directly
and firmly.
3 Radio frequency interference from other
remotes or electronic devices may be aecting
normal operation.
MASSAGE MOTORS SEEM
E X C E S S I V E L Y L O U D
DURING OPERATION
1 Hard surface flooring may cause added
vibration. To correct, place carpet pieces or
rubber furniture cups under each leg or caster
of the bed.
2 Elevate the head or foot section a short
distance (with the remote control) to realign
the lift/ lower mechanisms with the bed
support platform.
3 Check that the bed is not in direct contact with
a wall, nightstand, or other object that may
cause vibration or noise.
4 If Adjustable Base is installed on top of a bed
frame, check that the massage motors are not
causing bed frame (or bed frame components)
to vibrate or rattle.
5 Check that the headboard attachment
hardware is tightened firmly (if used).
Troubleshooting
In the event the Adjustable Base fails to operate, investigate the problems and possible solutions provided below.

13
IF YOU EXPERIENCE ANY TROUBLE
WITH YOUR ADJUSTABLE BASE WITHIN
THE WARRANTY PERIOD, PLEASE
CONSULT THE TROUBLESHOOTING
GUIDE PROVIDED WITH YOUR
FRAME AND ONLINE (IF APPLICABLE).
IF PROBLEMS PERSIST, PLEASE CALL.
CUSTOMER SERVICE
TOLL FREE NUMBER:
1-800-499-1965
Please have your receipt ready
and available.
THANK YOU AND ENJOY YOUR
ADJUSTABLE BASE!

14
ADJUSTABLE BASE:
20-YEAR LIMITED WARRANTY
SEALY, INC. (“SEALY®“) GUARANTEES
THAT WE WILL, AT SEALY’S OPTION,
REPLACE OR REPAIR PURCHASER’S
REFLEXION®SYSTEM IF IT IS DEFECTIVE
DUE TO FAULTY WORKMANSHIP
OR MATERIALS, SUBJECT TO
THE LIMITATIONS DESCRIBED IN
THIS WARRANTY.
YEAR 1: FULL COVERAGE
OF PARTS AND LABOR
Your Reflexion®adjustable base system is
warranted against defects in the workmanship
or materials for a period of one (1) year from
the warranty commencement date. Electronics,
electrical components, drive motors and massage
motors are included. Upon notice during the first
year from the warranty commencement date,
Sealy will send replacement parts (at no cost
to the purchaser) for any defective part to the
purchaser, and Sealy will pay all authorized labor
and transportation costs associated with the repair
or replacement of any parts Sealy determines
to be defective. This one (1) year warranty shall
not apply if purchaser does not return any and
all defective parts to Sealy within 15 days of
purchaser’s receipt of replacement part.
YEARS 2 AND 3: FULL COVERAGE
OF PARTS ONLY
Upon notice during the years two and three (2–3)
from the warranty commencement date, Sealy
will oer replacement parts for any defective
part to the purchaser. Electronics, electrical
components, drive motors and massage motors
are included. This two (2) year warranty shall
not apply if purchaser does not return any
and all defective parts to Sealy within 15 days
of purchaser’s receipt of replacement part.
Purchaser shall bear all service, transportation,
labor, and shipping costs related to the delivery
and/or replacement of the defective part.
YEARS 4 THROUGH 20: PRORATED
COVERAGE OF PARTS ONLY
Upon notice during the fourth through the
twentieth (4–20) years from the warranty
commencement date, Sealy will oer
replacement parts (upon terms and conditions
set forth in this paragraph) for any mechanical
bed part found to be defective. Electronics,
electrical components, drive motors and
massage motors are excluded. Purchaser shall
pay 1/17th of the then current replacement cost
of the defective part multiplied by the number
of years after three (3) years from the warranty
commencement date, and Sealy shall bear the
remainder of the cost of the replacement part.
This seventeen (17) year warranty shall not apply
if purchaser does not return any and all defective
parts to Sealy within 15 days of purchaser’s
receipt of replacement part. Purchaser shall bear
all service, transportation, labor, and shipping
costs related to the delivery and/ or replacement
of the defective part. After the 20th year,
purchaser shall bear the entire cost of repair and
replacement of all parts and materials, including
labor and transportation.
ADDITIONAL TERMS
AND CONDITIONS
This warranty does not apply;
a to any damage caused by the purchaser;
b if there has been any unauthorized repair or
replacement of the unit’s parts;
c if the unit has been mishandled (whether in
transit or by other means), subjected to physical
or electrical abuse or misuse, or otherwise
operated in any way inconsistent with the
operation and maintenance procedures
outlined in the Complete Reference Guide, this
warranty, and any other applicable document
published or approved by Sealy;
d to damage to mattresses, fabric, cables,
electrical cords or items supplied by Resellers;
e if there has been any unnecessary service calls,
including costs for in-home service calls solely
for the purpose of educating the consumer
about the unit for finding an unsatisfactory
power connection; and
g if the recommended weight restrictions are
not followed (Twin Long, Split/Dual CA King:
300 lbs.; Queen: 425 lbs.), the warranty
will be void.
Repairs to or replacement of the Reflexion®
system or its components under the terms of
this limited warranty will apply to the original
warranty period and will not serve to extend
such period.
Warranty

15
The decision to repair or to replace defective
parts under this warranty shall be made, or
case to be made, by Sealy at its option and in
its sole discretion.
REPAIR OR REPLACEMENT SHALL BE THE SOLE
REMEDY OF THE PURCHASER. THERE SHALL
BE NO LIABILITY ON THE PART OF SEALY
FOR ANY SPECIAL, INDIRECT, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES OR FOR
ANY OTHER DAMAGE, CLAIM, OR LOSS NOT
EXPRESSLY COVERED BY THE TERMS OF
THIS WARRANTY. THIS LIMITED WARRANTY
DOES NOT INCLUDE REIMBURSEMENT FOR
INCONVENIENCE, REMOVAL, INSTALLATION,
SETUP TIME, LOSS OF USE, SHIPPING, OR ANY
OTHER COSTS OR EXPENSES. SEALY MAKES NO
OTHER WARRANTY WHATSOEVER, EXPRESS
OR IMPLIED, AND ALL IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE DISCLAIMED BY
SEALY AND EXCLUDED FROM THIS AGREEMENT.
Some states do not allow the exclusion or
limitation of incidental or consequential
damages, so the above limitation or exclusion
may not apply to every purchaser. This warranty
gives the purchaser specific legal rights, and the
purchaser may also have other rights, which
may vary from state to state. This warranty is
valid in all 50 states, Puerto Rico, and Canada.
This warranty is valid only for the original
purchaser of the product. An original purchaser
is one who purchases the product directly from
Sealy, Inc. or an authorized Reseller of Sealy, Inc.
If you are not the original purchaser of this
product, you take it “as is“ and “with all faults.“
If you did not purchase this Reflexion®system
directly from Sealy, Inc., we will require proof
of purchase from you demonstrating that you
are the original purchaser and eligible to make
a valid claim under this warranty. This warranty
begins on the “warranty commencement date“
which is the date of purchase for new unused
units, and the date of manufacture for units
that have been used as floor or display models.
Thus, on a floor model unit, the warranty is
a portion of the limited 20-year warranty. If
original proof of purchase is not provided by
purchaser, Sealy reserves the right to determine
if the unit is not covered by this warranty or
to use the manufacturing date as the warranty
commencement date. This limited warranty gives
you specific legal rights. You may also have other
rights that vary from state to state.
BINDING ARBITRATION
AND CLASS ACTION WAIVER
FOR U.S. RESIDENTS
a This section applies to any dispute except
it does not include a Dispute relating to the
enforcement or validity of your, Sealy’s, or
any of our licensors’ intellectual property
rights. “Dispute” means any dispute, action,
or other controversy between you and
Sealy concerning your Sealy mattress or this
warranty, whether in contract, warranty, tort,
statute, regulation, ordinance, or any other
legal or equitable basis. “Dispute” will be given
the broadest possible meaning allowable
under law.
b In the event of a dispute, you or Sealy must
give the other a Notice of Dispute, which
is a written statement that sets forth the
name, address and contact information of
the party giving it, the facts giving rise to the
dispute, and the relief requested. You must
send any Notice of Dispute by U.S. Mail to
Sealy, Inc., ATTN: Oce of General Counsel,
1000 Tempur Way, Lexington, KY 40511.
Sealy will send any Notice of Dispute to
You by U.S. Mail to Your address if we have
it or to your email address if we have it.
You and Sealy will attempt to resolve any
dispute through informal negotiation within
60 days from the date the Notice of Dispute
is sent. After 60 days, you or Sealy may
commence arbitration.
c You may also litigate any dispute in small
claims court in your county of residence or
Fayette County, Kentucky if the dispute meets
all requirements to be heard in the small claims
court. You may litigate in small claims court
whether or not you negotiated informally first.
d If you and Sealy do not resolve any dispute
by informal negotiation or in small claims
court, any other eort to resolve the dispute
will be conducted exclusively by binding
arbitration. You are giving up the right to
litigate (or participate in as a party or class
member) all disputes in court before a judge or
jury. Instead, all disputes will be resolved before
a neutral arbitrator, whose decision will be
final except for a limited right of appeal under
the Federal Arbitration Act. Any court with
jurisdiction over the parties may enforce the
arbitrator’s award.

16
e Any proceedings to resolve or litigate any
dispute in any forum will be conducted solely
on an individual basis. Neither You nor Sealy
will seek to have any dispute heard as a class
action, private attorney general action, or in
any other proceeding in which either party
acts or proposes to act in a representative
capacity. No arbitration or proceeding will
be combined with another without the prior
written consent of all parties to all aected
arbitrations or proceedings.
f Any arbitration will be conducted by the
American Arbitration Association (the “AAA”)
under its Commercial Arbitration Rules
applying U.S. Federal Rules of Procedure
and U.S. Federal Rules of Evidence. The AAA
Supplementary Procedures for Consumer-
Related Disputes will also apply. For more
information, see www.adr.org or call
1-800-778-7879. You agree to commence
arbitration only in your county of residence
or in Fayette County, Kentucky. Sealy agrees
to commence arbitration only in your county
of residence. You may request a telephonic or
in-person hearing by following the AAA rules.
In a dispute involving $10,000 or less, any
hearing will be telephonic unless the arbitrator
finds good cause to hold an in-person hearing
instead. The arbitrator may award the same
damages to you individually as a court could.
The arbitrator may award declaratory or
injunctive relief only to you individually, and
only to the extent required to satisfy your
individual claim.
g Sealy will promptly reimburse your filing fees
and pay the AAA’s and arbitrator’s fees and
expenses as provided below. If you reject
Sealy’s last written settlement oer made
before the arbitrator was appointed (“Sealy’s
last written oer”), your dispute goes all the
way to an arbitrator’s decision (called an
“award”), and the arbitrator awards you more
than Sealy’s last written oer, Sealy will give
you three incentives: (i) pay the greater of the
award or $5,000; (ii) pay twice your reasonable
attorney’s fees, if any; and (iii) reimburse any
expenses (including expert witness fees and
costs) that your attorney reasonably accrues
for investigating, preparing, and pursuing
your claim in arbitration. The arbitrator will
determine the amount of fees, costs, and
expenses unless you and Sealy agree on them.
For purposes of this limited warranty, an email
shall be considered a written communication.
h In any arbitration you commence, Sealy will
seek its AAA or arbitrator’s fees and expenses,
or your filing fees it reimbursed, only if the
arbitrator finds the arbitration frivolous or
brought for an improper purpose. In any
arbitration Sealy commences, Sealy will pay all
filing, AAA, and arbitrator’s fees and expenses.
Sealy may also seek its attorney’s fees or
expenses from you in any arbitration. Fees and
expenses are not counted in determining how
much a dispute involves.
i This warranty governs to the extent it conflicts
with AAA’s Commercial Arbitration Rules and
Supplementary Procedures for Consumer-
Related Disputes.
j To the extent permitted by law, any claim or
dispute under this Limited Warranty must be
filed within one year in small claims court,
an arbitration proceeding, or in court, if so
permitted herein. The one-year period begins
when the claim or Notice of Dispute first could
be filed. If a claim or dispute is not filed within
one year, it is permanently barred.
k If the class action waiver is found to be illegal
or unenforceable as to all or some parts
of a dispute, then it will not apply to those
parts. Instead, those parts will be severed and
proceed in a court of law, with the remaining
parts proceeding in arbitration. If any other
provision of this section is found to be illegal or
unenforceable, that provision will be severed
with the remainder of this section remaining in
full force and eect.
All parts of this Limited Warranty apply to the
maximum extent permitted by law or unless
prohibited by law. This Limited Warranty gives the
purchaser specific legal rights, and the purchaser
may also have other rights, which may vary from
state to state.
If you experience any trouble with your
Reflexion®system during the warranty period,
please consult the troubleshooting section
of your Reference Guide. If problems persist
after following these instructions, please call:
1-800-499-1965.
Warranty (continued)


IF YOU EXPERIENCE ANY TROUBLE WITH YOUR ADJUSTABLE BASE
WITHIN THE WARRANTY PERIOD, PLEASE CONSULT THE TROUBLESHOOTING
GUIDE PROVIDED WITH YOUR FRAME AND ONLINE (IF APPLICABLE).
IF PROBLEMS PERSIST, PLEASE CALL.
CUSTOMER SERVICE TOLL FREE NUMBER:
1-800-499-1965
Please have your receipt ready and available.
THANK YOU AND ENJOY YOUR ADJUSTABLE BASE!
Model Number: 609663
Serial Number: ________________________________
(Place your serial number here for ready reference.)
©2014 Tempur Sealy International
Table of contents
Other Sealy Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Malouf
Malouf Structures S655 owner's manual

Furniture of America
Furniture of America CM7389EK Assembly instructions

Alpine
Alpine Peacock BVK608A owner's manual

Asko
Asko VITA 2 U-FORM Assembly instructions

HULALA HOME
HULALA HOME SCBSD0531 Assembly instructions

READY To ASSEMBLE
READY To ASSEMBLE HEADBOARD Assembly instructions