Seamax SUP20MAX Double Stage User manual

1 | P a g e
Seamax Intelligent 12V Digital Air Pump
MANUAL OF MODEL - SUP20MAX DOUBLE STAGE
Congratulations on your purchase of this SUP20MAX Double Stage 12V Electric Air Pump. This intelligent DC
electric pump has built-in dual stage inflators with digital control and a LCD screen to display the set pressure and
real-time air pressure. This pump can quickly reach and auto stop at user preset air pressure, you will never over
inflate your paddle board chamber. This model also has a deflation port to help user quickly deflate the air from
the chamber, so the boat or SUP can be easier to fold for storage.
Thanks to the intelligent control system and its new design power unit, this air pump is great to use with your
inflatable tent, boats and SUP, easy to support up to 20PSI and with our 1 years guarantee. This model of electric
air pump can be your all-in-one solution, at the mean time it is light weight to carry and easy to use. Please take a
few minutes to read this instruction and become familiar with its operation.

2 | P a g e
CONTENTS
Safety Note....................................................................................................................................................................3
Need to Know ...............................................................................................................................................................4
New Features and Protection .......................................................................................................................................5
More O-Rings for More Support ...................................................................................................................................5
Pump Check List............................................................................................................................................................6
First Time Use ...............................................................................................................................................................7
Inflation Operation........................................................................................................................................................7
Deflation Operation ......................................................................................................................................................8
Special Smart Pressure Monitoring...............................................................................................................................8
Specifications – SUP20MAX ..........................................................................................................................................9
Troubleshooting............................................................................................................................................................9
Air Valve Connection...................................................................................................................................................11
Maintenance and Storage...........................................................................................................................................11
Limited Warranty ........................................................................................................................................................12
Contact Seamax ..........................................................................................................................................................13
MULTI-LANGUAGES TRANSLATED BY GOOGLE ...........................................................................................................14

3 | P a g e
SAFETY NOTE
▪To guard against injury, basic safety precautions should be observed.
▪To avoid possible electrical shock or fire, special care should be taken when using the product near gas, fuel
or metal. Do NOT use the pump closed to fuel tank, gas tank, or open flame.
▪Keep the pump and packing material away from Children. Store it in a dry and cool area away from water and
heat.
▪This product is not applicable for the person with declining physical strength, sensory ability or mental
capacity, the person lack of skill and the mentally retarded person, unless they are under the protection of
their guardians, supervised and directed at the same time.
▪Before moving, maintaining, repairing or adjusting this product, please first pull out the DC plug from the
socket.
▪If the power wire is damaged, it must be changed or repaired by the manufacturer or its service agent or the
similar authorized personnel, in case of any risk. Do NOT use this product if the power wire is damaged.
▪Before inflating any inflatable products, must check their maximum bearable air pressure. The air chamber
may be damaged if upon exceeding their maximum bearable pressure.
▪Before using the pump, check the car's cigarette lighter socket to make sure that there is no rust or residue
inside. The cigarette lighter socket with poor electric conduction may cause overheating of the pump and
power source.
▪First disconnect the air hose from chamber when fully inflated. Be careful of high pressure air flow to prevent
any possible personal injury.
▪The purpose of using this product is limited to the description in the owner's manual.
▪Be aware of your local recycle regulation for proper disposal of electronic products.

4 | P a g e
NEED TO KNOW
▪The pump's maximum air pressure is 20 PSI (1.378 Bar /138 Kilo-Pascal). The air pressure user setting is
recorded in the pump memory when power disconnected. Before every use of this pump, it is user's solely
responsibility to make sure that the pump is set to the desired air pressure. Incorrect air pressure setting may
either under or over inflate the inflatable product.
▪This pump is designed to use car cigarette lighter port or boat 12V DC socket. If you will use a portable
battery, please make sure your pump’s battery fully charged before your trip. Also make sure the battery
voltage is 12V. The max loading of power source can support 15 Amp current. The pump requires a minimum
12V, 7AH battery as power source to work properly.
▪Always check the air hose, valve connector, and the inflatable product before starting the pump. Do not block
the Inflation port and Deflation port. This pump will make a loudly sound since its high pressure 2nd stage
cylinder pumping unit.
▪This pump can auto switch from 1st stage to 2nd stage, or 2nd stage to 1st stage base on the pressure reading
from its internal sensor. The switch point is set at 0.8 PSI.
▪The pump will auto stop after continuously running for 20 minutes. It is suggested to cool down the pump
before its next continuous operation. Otherwise you must check the pump temperature before next use. For
fast cool down the pump, you can turn on the air pump to let it work in the air for 1 minute.
▪If you have to return the product, please first contact with Seamax Marine or the dealer that you purchase it
from. Repairs may only be performed by an authorized service technician. The manufacturer is not
responsible for damage caused as a result of improper use or failure to observe these instructions.
▪This pump shall not be exposed to the rain or immersed in water. Do NOT leave the pump unattended while
inflating.
▪You need to tune up your car 12V socket if you see the pump power plug over heat.
▪Dirt inside the car 12V spclet will cause fire. Always check the connection before use. Our provided 12V
battery click will help you the avoid those issues. Always carry this part with your pump.
▪Wrong operation or self modification may cause the pump and car damage.
QUICK AND EASY CONNECTION
Select a Right O-Ring for Air Valve Screw in the Air Hose on the Pump Connect to 12V Cigarette Lighter Port

5 | P a g e
NEW FEATURES AND PROTECTION
▪Fully Suppport Auto Model or Manual Mode. When you inflate a product that the auto model cannot fulfill
your requirement. For example the pump cannot switch to 2nd stage, or switch to 2nd stage too early. Or you
may never need the 2nd stage pressure too high. You can choice its manual model.
Simply press the “HIGH” button to directly start the pump 2nd stage air compressor. It is suitable for using the
pump with smaller air valve adaptor against the back pressure, such as a boston air valve. You can also press
the “LOW” button to start the pump with 1st stage only. The turbo fan will be on and keep going. But the
pump won’t switch to the 2nd stage. Pressure the same botton again to stop the pump from manual mode or
auto model.
Those combination will help you to use this punp with a wide rage inflatable products, including kayak,
mattress and many other water toys. A built-in cooling fan will extend the pump continued working time to
30 minutes.
▪Input voltage real time monitoring system. Pump normal working voltage range is 9V-15V. This pump will stop
working or won’t start if the voltage is below 9V or over 15V. If the input voltage is too low, the pump will not
have enough power to inflate your inflatable product’s air chamber to a higher pressure fast enough. Such
situation will easily cause the pump’s piston overheat damage. If the input voltage is too high, it will cause
motor overheat issue and burn the pump electronic components. ERROR icon and voltage reading will keep
blinking when voltage issue detected. The pump will be back to normal after the detected voltage is within its
safe working range (9 to 15V).
▪Overheat protection. When the pump’s internal temperature reaches 85 Celsius degree (85°C or 185°F), the
pump will stop working immediately. And the pump “Start Up” feature will be locked for temporary Self-Protection.
The LCD screen will show a flashing ERROR – OVERHEAT message. The pump will be automatically unlocked after
its internal temperature drops below 50°C (122°F). To bypass this waiting period, user can reconnect its power plug
to reset the pump. Disconnect the air hose and turn on the pump in cool air for 3 minutes for fast cooling down before
pumping again.
▪When the air pressure is over 5 PSI and below the user’s set pressure, the pump will start monitoring the
pressure increment. If the pressure increment is less than 0.05 PSI after 20 seconds continuous running, the
Pump Self-Protection will be activated and stop working. User should check all the connection and O Rings
size to make sure all components’ air tight and right fit, before start pumping again. If without this self-
protection, the inflator could be permanently damaged in few minutes.
▪The pump will stop automatically after 20 minutes continuous running regardless the pump’s working stage
and condition.

6 | P a g e
PUMP PACKAGE CHECK LIST
Please make sure the following accessories are provided in the box. In case of any parts missing, please contact
the original seller or Seamax. Spend some time to study this manual and experience all the pump functions
especially how to properly set the target air pressure before trying to inflate a product.
Air Pump – SUP20MAX
Hose Kit with Multiple Adapters
3 Size O-Rings, Spare Fuse
The pump’s 12V DC cigarette lighter power adapter has a
built-in 12A fuse. Unscrewing the head connector bolt can
access this fuse if replacement needed. When the pump is
connected to the car charger socket but no power, please first
to check this fuse. Don’t lose the fuse spring. This fuse spring
could be similar to the spring of a regular pen if lost.

7 | P a g e
FIRST TIME USE
▪Select a valve adapter and an O-Ring with correct thickness to fit your inflatable product’s air valve.
▪You can use your original valve adapter if it provides better inflation result than using the ones provided
with the pump. To modify the valve connector won’t affect your pump existing warranty coverage.
▪Test Run is necessary before the first time use. You can stop the pump any time by pressing its power
button. Do NOT leave the pump running unattended even considering its auto stop feature!
▪Do NOT let the pump running for more than 20 minutes continuously. Inflate one SUP / Paddle Boat at a
time. Extended usage beyond its recommended continuous running time can cause overheating and
damage the internal inflator.
▪Using smaller valve fittings limits the airflow speed, so the pump will be easier to get overheated. User's
attention is very important for this type of application. The max 20 minutes continuous working time must
be reduced accordingly.
▪Low quality instable power source will decrease the pump running performance. The needed time to
complete inflating a product will be increased. This can cause overheating issue and damage the pump's
inflator quickly. Do NOT operate the pump with any low capacity, low voltage, and low quality battery.
▪If the air hose section near the pump port is getting warmer such as over 60ºC (92ºF), stop using the
pump immediately to let it cool down first.
▪If the environment temperature is too high, the pump's maximum continuous working time shall be
reduced accordingly.
INFLATION OPERATION
▪Plug the pump power adapter into the car's 12V DC socket, or to a battery with a convertor.
▪Connect the end with flexible conduit adaptor (1) of the air hose with the air pump inflation port (1), and
twist clockwise to tighten it (Figure 1).
▪Connect the other end of the air hose with an air valve adapter. Insert it into the supported product's air
valve and twist clockwise to fix it (Figure 2).
▪Press the air pressure unit toggle button [PSI/BAR] to select your preferred unit such PSI or BAR.
▪Press the Increase Air Pressure button [+] or cycle as decrease Air Pressure button. Set the desired target
pressure value matching with your inflatable product's air pressure requirement from 0.5 PSI to 20 PSI
(1PSI=0.0689BAR).
▪The pressure setting increasement is 0.5 PSI. Press the On/Off power switch button to start the pump.
▪During the inflating process, you can press the Increase Air Pressure button [+] or Decrease Air Pressure
Button [-] to adjust the target air pressure value. Press the Air Pressure Unit toggle button [PSI/BAR] to
switch the air pressure unit. Pressing the On/Off power button can stop pumping manually.

8 | P a g e
▪During the inflating process, the LCD screen displays the inflatable product’s on-going real time air
pressure. The preset target air pressure number will appear in every 3 seconds in flashing mode for the
user’s information.
DEFLATION OPERATION
▪Remove the hose from the inflation port. Connect the end with flexible conduit adaptor (11) of the hose
with the air pump deflation port (2). Twist clockwise to tighten it (Figure 3 – SUP20D). The other end shall
still be to the inflatable product. Please know you should release all the high pressure air before attach
the pump for deflation. Press the On/Off Power Button to start the deflation until all the air inside the
inflatable product is discharged. Turn off the air pump to stop the deflation.
SPECIAL PRESSURE MONITORING FEATURE
This SUP20MAX Air pump is equipped with a special Smart Pressure Monitoring Feature. Once the pressure
reading reaches 0.6 PSI when inflating in the 1ST stage, the program will start monitoring the pressure
increasement. If the pressure increasement is less than 0.03 PSI in a period of continuous 6 seconds, the internal
controller sees the 1ST stage is reaching its max inflation capacity. Then the pump will receive a signal to stop the
1st stage and start the 2nd stage inflation by the piston compressor.
Based on the new program, this pump can provide the best inflation efficiency for inflatable SUP, boat, kite, tent
and any kinds of inflatable tops provided using a suitable air valve adapter and max 20 PSI pressure requirement
met. It saves user’s time and energy to quickly inflate the product to the targeted PSI.
To best utilize this function in the proper way, a good condition qualified power source is necessary to suppor the
pump. During the whole inflation process, users need to make sure the air tightness and minimized air leaking
along the air passage from the pump’s inflation port to your inflatable product through the air hose connection.
In case the pump could not automatically switch to the 2nd stage, user can stop the pump and make sure the
chamber reading pressure can be over 0.6PSI, and you start the pump again to activate the 2nd stage manually. If
the pump detects over 0.6 PSI pressure when started, it will bypass the 1st stage and switch to the 2nd stage for
high pressure pumping directly.
Tips: if the 1st stage could not start properly in some unsual situation, user can use a manual pump to inflate the
product to about 1 PSI, and then use this pump to do the rest of the inflation proess directly starting from tis 2nd
stage. When the air pressure is over 5 PSI, the pump will start the monitoring program again. If the pressure
increasement rate start to decrese for a set period of time or the internal tempreture is over 85 Celsius (185
Fahrenheit), the internal protection mode will be activated. The pump will stop automatically to avoid over
heating issue.

9 | P a g e
SPECIFICATIONS –SUP20MAX
- Pump Support Rate: 0.5-20 PSI (0.034-1.378 Bar)
- Digital Sensor Accuracy: 0.01 PSI
- Controller Method: Pre-programmed digital controller board
- Max Pumping Speed: 1st Stage 350L/min, 2nd stage 70L/min
- Pump Stage 1: Sealed & Quiet turbo fan for high volume inflation
- Pump Stage 2: Engineered cylinder compressor for high pressure
- Dual Inflators Switch Point: 0.6 PSI or up
- Built in cooling fan, always turn on when power connected
- O Ring Thickness: 0.3mm / 0.5mm / 0.6mm
- Sand Filter: Built-in filters for air intake
- Pump Working Voltage: 10-14V DC
- Max Energy Consumption: 10A, 120W (12V)
- DC Power Cord Length: 12ft (3.75m)
- Air Hose: 4.4ft Length with Multiple Fittings
- Product Net Weight: 3.8 Lbs
Note
This air pump also fully support inflatable
boats and inflatable kite when equip with
H.R. air valve.
TROUBLESHOOTING
Reconnect the Power Cord for fast check before troubleshotting!
Most of the issue may be caused by low power voltage or weak 12V connection. Continuous usage of the
pump in such condition can easily damage the pump’s 2nd stage compressor due to overheating issue.
Before solving the inferior power source issue, user shall not use the pump in the same condition for over 3
minutes. Following guideline can help users perform basic troubleshooting steps.
▪If not done yet, use your car’s battery as the power source. This pump needs a good battery to
continuosly provide 15 Amp output for its 12 Amp power consumption. Do NOT use a small 110V to 12V
DC convertor even they are 15A rate.
▪If the car battery is over 2 years old or purchased as used, you can turn on the engine when pumping and
see any difference. Best you can check the battery voltage with Digital Electric Multimeter and make
sure battery voltage over 12V.
▪You should check your air hose connection of air tight. Make sure you put a right size O ring on the valve
adaptor. When you turn off the pump with a certain pressure remain in the SUP chamber, do not
disconnect the hose, you should not hear any air leaking from the connection in both side of hose. You
can also use 5% soapy water to check to verify the air leaking.
▪Tune up your 12V socket is very important, you can shiny the socket by using Sand Paper. Lighting
cigarette can make the 12V socked with extra electrical resistance. Even a GPS is working fine, but it may
not be good enough for this pump since 12Amp needed. So we want you to check this part or change
another socket or vehicle to try.

10 | P a g e
You can discuss with us for any other problems. Otherwise if your pump had been checked and no more high
pressure created. we believe your pump had been damaged. Then you get to contact us via email directly for
repair or replacement. You can find our email from Seamax Marine website or the pump user manual. Since
we can’t give you our email address from Amazon message. You can forward this message to our customer
service with your original order ID. And you may need to pay for the shipping and handling cost if your
purchase is over 60 days and return the original pump. Thanks again for contact Seamax.
FAULT
INSPECTION
SOLUTION
The air pump
cannot be started
normally.
1. The power source is not
plugged properly.
2. The fuse in DC plug (7) is
burnt out.
3. Overheating or overload.
1. Make sure the connect to the 12V DC socket.
2. Change the fuse.
3. Take off the Sand Cap from the pump intake or outtake. Cool
the motor and restart it. Turn on the pump in the air to force it
fast cool down.
Slow or abnormal
inflation.
Pump stop before
reach set pressure
1. Check whether the hose is
blocked or cracked.
2. The joint between the
hose and air pump or
inflatable product is not
installed properly.
3. Make sure the power
source meets the pump’s
requirements 12V 15A
4. Check input voltage, make
sure not voltage low issue
5. Check Temperature
1. Change the hose or make it unblocked, and check whether the
hose is cracked.
2. Reinstall the hose or valve adaptor, put the right size O ring
3. If the problem cannot be solved, please contact with the
manufacturer or its service agent or the similar authorized
personnel.
4. Do NOT use compact AC to DC wall convertors to power the
pump. Connect the pump car charger adapter directly to a car’s
charger socket. Or use a well charged minimum 12V 7AH external
lead acid battery with the optional 12V battery connector.
5. check the input voltage before the pump stop, make sure the
voltage is within 9-15V. . If the internal tempature too hot, the
pump will stop with its screen showing over-heat.

11 | P a g e
AIR VALVE CONNECTION
▪This pump is suitable for the products with HR (Halkey-Roberts), Bravo or similar air valve. They are the most
popular air valves for the inflatable SUPs and paddle boards in the current market. This type of air valve has a
center turning pin (HR valve) or pushing pin (Bravo) control the air valve’s Open / Close position. The universal
valve adapter supplied with the pump shall fit it.
▪Please make sure the air valve is in its Close position when inflating the air chamber. Otherwise, some air may
leak from the valve when the air hose is being disconnected. Our air pump comes with universal HR valve
adaptor with 3 different thickness Silicon Rubber O-Rings (3mm/5mm/6mm ). The 6mm O-ring is per-installed
on the air hose valve adaptor. It should have one to fit your air valve best and air tight.
▪If you cannot use our valve adapter for your inflatable product, you may have to cut the hose to install yours
from the original manual pump. You can use the electric tape to ensure the diameter fit and tight. You can also
contact with Seamax Marine to apply a set of Free Air Hose for this modification.
SMALL LARGE
MAINTENANCE AND STORAGE
▪After use, or if you want to move, maintain or adjust the product, first pull out the DC plug from the socket.
Clean all dirt from the pump. If the pump gets wet, let it dry in the air before packing it into a carrying bag.
▪The pump shall be properly stored after being fully cooled. It shall not be exposed to the rain or immersed in
water. We provide a cap to protect the dirt getting into your pump.
▪Store it in a dry and ventilated place. Check the preset air pressure setting before you turn off the air pump.
Best to store your pump in the temperature range at 5º C -20º C (37º F - 52º F).
▪This pump does not have a built-in battery. For your own Lead Acid battery, you should fully charge it before
storing. Leaving the battery in a poorly charged state for extended periods of time (1 month or more) will
damage the battery.

12 | P a g e
LIMITED WARRANTY
▪SEAMAX electric air pumps are warranted to be free of defects in materials and workmanship during the
following prescribed warranty period. This warranty applies to defective factory parts under normal operating
conditions.
▪The warranty covers the brand-new item originally purchased from Seamax Marine or its authorized dealers. The
warranty can not be transferred to any subsequent purchasers. Keep the original sales record and the product
labels for warranty service. Any repaired items and warranty replacement will not extend their original warranty.
▪Warranty claims are handled by Seamax Marine or its authorized dealers. Contact the original seller of the item
to obtain warranty authorization prior to returning the product. Seller can ask for proof of purchase and current
product condition such as pictures and video. Seller reserves the right to refuse a warranty claim if the product
shows excessive wear, abuse, or misuse.
▪Seller’s obligation under this warranty shall be limited to repairing a defective part, or at seller’s discretion,
refunding the purchase price or replacing such part or parts as shall be necessary to remedy ANY defect in
material or workmanship as covered by this warranty.
▪This warranty does not apply to normal wear and tear, or to damage caused by: (1). Neglect, lack of maintenance,
accident, commercial, abnormal or improper use or incorrect assembly in accordance with the user manual; (2).
Use of an accessory or part neither manufactured nor sold by an authorized dealer; (3). Alteration or removal of
parts without authorization from the original seller; (4). Improper protection against UV-light, high temperature
and heat sources; (5). Has been repaired, modified or tampered with by someone other than manufacturer or
authorized dealers without approval; (6). damaged as a result of shipping or storage.
▪This warranty does not cover incidental or consequential costs and expenses such as lost of use, transportation
delay, storage charge, telephone or rental charges of any type, inconvenience, waste of time or income losses,
or other consequential damages.
Coverage Period
▪For recreational use, the warranty covers the electrical control boards, motors, and charger for one (1) year from
the original purchase date. Housing, air hose, and valve adapters are guaranteed for 180-days from the original
purchase date.
▪For commercial use including for SUP rental business, the warranty covers the product for 60 days from purchase
date and limit to factory deflects only, damage from normal wear and tear are not covered.
▪Seamax may offer repair service for a pump still in repairable condition after its warranty period with minimum
charges for parts, labor, and shipping.
Shipping Coverage
▪Traceable standard surface shipping service is applicable for authorized RMA shipments. If needed, Buyer may
require and is responsible for any upgraded expedited, express, or non-surface shipping service.
▪Seller may cover two-ways ground shipping fee within 30-days from the original date of purchase if a warranty
claim is authorized and classified for recreational use
▪Seller may cover one-way ground shipping fee after 30-days and within 180-days from the original date of
purchase if a warranty claim is authorized and classified for recreational use.
▪Customer shall pay two-ways shipping fee after 180-days from the date of purchase if a warranty claim is
authorized. There is NO shipping service coverage for international buyer out of lower 48 states of USA and
Canada.
▪Commercial use including for SUP rental business, we won’t cover any shipping cost.
▪Seller will not accept any unauthorized return shipments. C.O.D delivery will be rejected without further notice
to its sender. Seller is not responsible for any delay, misplaced, or lost of unauthorized return shipments.

13 | P a g e

14 | P a g e
Customer can order the portable battery from Seamax with Discount Code “BATTERY4PUMP”
Built-in Power Plug Protection Socket
OUR CONTACT
Product Designed and Distributed by: Seamax Marine and Outdoor (Canada)
Head Office Address: 102-19155 38 Ave, Surrey, BC, Canada V3Z 0Y6
Toll free: 1-877-907-7766 Tel: 604-277-7766
www.seamaxmarine.com suppo[email protected]om

15 | P a g e
MULTI-LANGUAGEs TRANSLATED BY GOOGLE
FR (French)
Félicitations pour votre achat de cette pompe à air électrique à double étage SUP20MAX 12V. Cette pompe
électrique à courant continu intelligente est dotée de gonfleurs à deux étages intégrés avec commande numérique
et d'un écran LCD pour afficher la pression de consigne et la pression d'air en temps réel. Cette pompe peut atteindre
rapidement et s'arrêter automatiquement à la pression d'air prédéfinie par l'utilisateur, vous ne gonflerez jamais
trop la chambre de votre paddle board. Ce modèle dispose également d'un port de dégonflage pour aider
l'utilisateur à dégonfler rapidement l'air de la chambre, de sorte que le bateau ou le SUP peuvent être plus faciles à
plier pour le stockage. Grâce au système de contrôle intelligent et à sa nouvelle unité de puissance de conception,
cette pompe à air est idéale à utiliser avec votre tente gonflable, vos bateaux et votre SUP, facile à supporter jusqu'à
20PSI et avec notre garantie d'un an. Ce modèle de pompe à air électrique peut être votre solution tout-en-un, en
même temps, il est léger à transporter et facile à utiliser. Veuillez prendre quelques minutes pour lire cette
instruction et vous familiariser avec son fonctionnement.
CONSIGNE DE SÉCURITÉ
•Pour éviter les blessures, des précautions de sécurité de base doivent être observées.
•Pour éviter tout risque d'électrocution ou d'incendie, des précautions particulières doivent être prises lors de
l'utilisation du produit à proximité de gaz, de carburant ou de métal. N'utilisez PAS la pompe fermée au réservoir
de carburant, au réservoir d'essence ou à une flamme nue.
•Gardez la pompe et le matériel d'emballage hors de portée des enfants. Conservez-le dans un endroit sec et
frais à l'abri de l'eau et de la chaleur.
•Ce produit ne s'applique pas à la personne dont la force physique, la capacité sensorielle ou la capacité mentale
diminuent, la personne incompétente et la personne handicapée mentale, à moins qu'elles ne soient sous la
protection de leurs tuteurs, supervisées et dirigées en même temps.
•Avant de déplacer, d'entretenir, de réparer ou de régler ce produit, veuillez d'abord débrancher la fiche CC de
la prise.
•Si le câble d'alimentation est endommagé, il doit être changé ou réparé par le fabricant ou son agent de service
ou le personnel autorisé similaire, en cas de risque. N'utilisez PAS ce produit si le câble d'alimentation est
endommagé.
•Avant de gonfler des produits gonflables, vous devez vérifier leur pression d'air maximale supportable. La
chambre à air peut être endommagée si elle dépasse sa pression maximale supportable.
•Avant d'utiliser la pompe, vérifiez la prise allume-cigare de la voiture pour vous assurer qu'il n'y a pas de rouille
ou de résidu à l'intérieur. La prise allume-cigare avec une mauvaise conduction électrique peut provoquer une
surchauffe de la pompe et de la source d'alimentation.
•Débranchez d'abord le tuyau d'air de la chambre lorsqu'il est complètement gonflé. Faites attention au débit
d'air à haute pression pour éviter toute blessure corporelle possible.
•Le but de l'utilisation de ce produit est limité à la description dans le manuel du propriétaire.
•Soyez conscient de votre réglementation locale de recyclage pour une élimination appropriée des produits
électroniques.

16 | P a g e
DOIS SAVOIR
•La pression d'air maximale de la pompe est de 20 PSI (1,378 Bar / 138 Kilo-Pascal). Le réglage utilisateur de la
pression d'air est enregistré dans la mémoire de la pompe lorsque l'alimentation est coupée. Avant chaque
utilisation de cette pompe, il est de la seule responsabilité de l'utilisateur de s'assurer que la pompe est réglée
à la pression d'air souhaitée. Un réglage incorrect de la pression d'air peut sous-gonfler ou surgonfler le
produit gonflable.
•Cette pompe est conçue pour utiliser un port allume-cigare de voiture ou une prise 12 V CC de bateau. Si vous
utilisez une batterie portable, assurez-vous que la batterie de votre pompe est complètement chargée avant
votre voyage. Assurez-vous également que la tension de la batterie est de 12V. La charge maximale de la
source d'alimentation peut supporter un courant de 15 ampères. La pompe nécessite une batterie minimum
de 12V, 7AH comme source d'alimentation pour fonctionner correctement.
•Vérifiez toujours le tuyau d'air, le connecteur de la valve et le produit gonflable avant de démarrer la pompe.
Ne bloquez pas le port de gonflage et le port de dégonflage. Cette pompe fera un bruit fort depuis son unité
de pompage à cylindre haute pression de 2ème étage.
•Cette pompe peut passer automatiquement du 1er étage au 2e étage, ou du 2e étage au 1er étage en
fonction de la lecture de la pression de son capteur interne. Le point de commutation est réglé à 0,8 PSI.
•La pompe s'arrêtera automatiquement après avoir fonctionné en continu pendant 20 minutes. Il est suggéré
de refroidir la pompe avant son prochain fonctionnement continu. Sinon, vous devez vérifier la température
de la pompe avant la prochaine utilisation. Pour un refroidissement rapide de la pompe, vous pouvez allumer
la pompe à air pour la laisser fonctionner dans l'air pendant 1 minute.
•Si vous devez retourner le produit, veuillez d'abord contacter Seamax Marine ou le revendeur auprès duquel
vous l'avez acheté. Les réparations ne peuvent être effectuées que par un technicien de service agréé. Le
fabricant n'est pas responsable des dommages causés par une mauvaise utilisation ou le non-respect de ces
instructions.
•Cette pompe ne doit pas être exposée à la pluie ou immergée dans l'eau. Ne laissez PAS la pompe sans
surveillance pendant le gonflage.
•Vous devez régler la prise 12V de votre voiture si vous voyez que la prise d'alimentation de la pompe
surchauffe.
•La saleté à l'intérieur du spclet 12V de la voiture provoquera un incendie. Vérifiez toujours la connexion avant
utilisation. Notre clic de batterie 12V fourni vous aidera à éviter ces problèmes. Transportez toujours cette
pièce avec votre pompe.
•Un mauvais fonctionnement ou une auto-modification peuvent endommager la pompe et la voiture.
NEW FEATURES AND PROTECTION
•Prise en charge complète du modèle automatique ou du mode manuel. Lorsque vous gonflez un produit que le
modèle automobile ne peut pas répondre à vos besoins. Par exemple, la pompe ne peut pas passer au 2ème
étage ou passer au 2ème étage trop tôt. Ou vous n'aurez peut-être jamais besoin de la pression du 2e étage
trop élevée. Vous pouvez choisir son modèle manuel.
Appuyez simplement sur le bouton « HIGH » pour démarrer directement le compresseur d'air du 2ème étage
de la pompe. Il convient à l'utilisation de la pompe avec un adaptateur de vanne d'air plus petit contre la contre-
pression, comme une vanne d'air Boston. Vous pouvez également appuyer sur le bouton « LOW » pour
démarrer la pompe avec le 1er étage uniquement. Le ventilateur turbo sera allumé et continuera à fonctionner.
Mais la pompe ne passera pas au 2ème étage. Appuyez à nouveau sur le même bouton pour arrêter la pompe
du mode manuel ou du modèle automatique.
Ces combinaisons vous aideront à utiliser ce punp avec une large gamme de produits gonflables, notamment
un kayak, un matelas et de nombreux autres jouets aquatiques. Un ventilateur de refroidissement intégré
prolongera le temps de fonctionnement continu de la pompe à 30 minutes.

17 | P a g e
•Système de surveillance en temps réel de la tension d'entrée. La plage de tension de fonctionnement normale
de la pompe est de 9V-15V. Cette pompe cessera de fonctionner ou ne démarrera pas si la tension est inférieure
à 9V ou supérieure à 15V. Si la tension d'entrée est trop faible, la pompe n'aura pas assez de puissance pour
gonfler assez rapidement la chambre à air de votre produit gonflable à une pression plus élevée. Une telle
situation causera facilement des dommages de surchauffe du piston de la pompe. Si la tension d'entrée est trop
élevée, cela entraînera un problème de surchauffe du moteur et brûlera les composants électroniques de la
pompe. L'icône ERREUR et la lecture de la tension continueront de clignoter lorsqu'un problème de tension est
détecté. La pompe reviendra à la normale une fois que la tension détectée sera dans sa plage de fonctionnement
sûre (9 à 15 V).
•Protection contre la surchauffe. Lorsque la température interne de la pompe atteint 85 degrés Celsius (85 °C ou
185 °F), la pompe cesse de fonctionner immédiatement. Et la fonction « Démarrage » de la pompe sera
verrouillée pour une auto-protection temporaire. L'écran LCD affichera un message clignotant ERREUR –
SURCHAUFFE. La pompe sera automatiquement déverrouillée une fois que sa température interne sera
inférieure à 50 °C (122 °F). Pour contourner cette période d'attente, l'utilisateur peut rebrancher sa prise
d'alimentation pour réinitialiser la pompe. Débranchez le tuyau d'air et allumez la pompe à l'air frais pendant 3
minutes pour un refroidissement rapide avant de pomper à nouveau.
•Lorsque la pression d'air est supérieure à 5 PSI et inférieure à la pression définie par l'utilisateur, la pompe
commencera à surveiller l'incrément de pression. Si l'incrément de pression est inférieur à 0,05 PSI après 20
secondes de fonctionnement continu, l'autoprotection de la pompe sera activée et cessera de fonctionner.
L'utilisateur doit vérifier toutes les connexions et la taille des joints toriques pour s'assurer que tous les
composants sont bien ajustés et hermétiques, avant de recommencer à pomper. Sans cette auto-protection, le
gonfleur pourrait être endommagé de façon permanente en quelques minutes.
•La pompe s'arrêtera automatiquement après 20 minutes de fonctionnement continu quelle que soit la phase et
l'état de fonctionnement de la pompe.
PREMIÈRE UTILISATION
•Sélectionnez un adaptateur de valve et un joint torique d'une épaisseur appropriée pour s'adapter à la valve
d'air de votre produit gonflable.
•Vous pouvez utiliser votre adaptateur de valve d'origine s'il offre un meilleur résultat de gonflage que ceux
fournis avec la pompe. La modification du connecteur de valve n'affectera pas la couverture de garantie
existante de votre pompe.
•Test Run est nécessaire avant la première utilisation. Vous pouvez arrêter la pompe à tout moment en appuyant
sur son bouton d'alimentation. Ne laissez PAS la pompe fonctionner sans surveillance, même en tenant compte
de sa fonction d'arrêt automatique !
•Ne laissez PAS la pompe fonctionner pendant plus de 20 minutes en continu. Gonflez un SUP / Paddle Boat à la
fois. Une utilisation prolongée au-delà de son temps de fonctionnement continu recommandé peut provoquer
une surchauffe et endommager le gonfleur interne.
•L'utilisation de raccords de vanne plus petits limite la vitesse du flux d'air, de sorte que la pompe sera plus facile
à surchauffer. L'attention de l'utilisateur est très importante pour ce type d'application. Le temps de travail
continu de 20 minutes maximum doit être réduit en conséquence.
•Une source d'alimentation instable de faible qualité réduira les performances de fonctionnement de la pompe.
Le temps nécessaire pour terminer le gonflage d'un produit sera augmenté. Cela peut provoquer un problème
de surchauffe et endommager rapidement le gonfleur de la pompe. NE PAS faire fonctionner la pompe avec une
batterie de faible capacité, basse tension et de mauvaise qualité.
•Si la section du tuyau d'air près de l'orifice de la pompe se réchauffe, par exemple au-dessus de 60 °C (92 °F),
arrêtez immédiatement d'utiliser la pompe pour la laisser refroidir d'abord.
•Si la température ambiante est trop élevée, le temps de fonctionnement continu maximum de la pompe doit
être réduit en conséquence.

18 | P a g e
OPÉRATION DE GONFLAGE
•Branchez l'adaptateur d'alimentation de la pompe sur la prise 12 V CC de la voiture ou sur une batterie avec un
convertisseur.
•Connectez l'extrémité avec l'adaptateur de conduit flexible (1) du tuyau d'air à l'orifice de gonflage de la pompe
à air (1), et tournez dans le sens des aiguilles d'une montre pour le serrer.
•Connectez l'autre extrémité du tuyau d'air avec un adaptateur de valve d'air. Insérez-le dans la valve à air du
produit pris en charge et tournez dans le sens des aiguilles d'une montre pour le fixer.
•Appuyez sur le bouton à bascule de l'unité de pression d'air [PSI/BAR] pour sélectionner votre unité préférée
telle que PSI ou BAR.
•Appuyez sur le bouton d'augmentation de la pression d'air [+] ou utilisez le bouton de diminution de la pression
d'air. Définissez la valeur de pression cible souhaitée correspondant aux exigences de pression d'air de votre
produit gonflable de 0,5 PSI à 20 PSI (1PSI = 0,0689BAR).
•L'augmentation du réglage de la pression est de 0,5 PSI. Appuyez sur le bouton marche/arrêt pour démarrer la
pompe.
•Pendant le processus de gonflage, vous pouvez appuyer sur le bouton Augmenter la pression d'air [+] ou
Diminuer la pression d'air [-] pour ajuster la valeur de pression d'air cible. Appuyez sur le bouton à bascule de
l'unité de pression d'air [PSI/BAR] pour changer l'unité de pression d'air. Appuyer sur le bouton d'alimentation
marche/arrêt peut arrêter le pompage manuellement.
•Pendant le processus de gonflage, l'écran LCD affiche la pression d'air en temps réel du produit gonflable. Le
numéro de pression d'air cible prédéfini apparaîtra toutes les 3 secondes en mode clignotant pour l'information
de l'utilisateur.
OPÉRATION DE DÉGONFLAGE
•Retirez le tuyau du port de gonflage. Connectez l'extrémité avec l'adaptateur de conduit flexible (11) du tuyau
avec l'orifice de dégonflage de la pompe à air (2). Tournez dans le sens horaire pour le serrer (Figure 3 – SUP20D).
L'autre extrémité doit toujours être au produit gonflable. Veuillez savoir que vous devez libérer tout l'air à haute
pression avant de fixer la pompe pour le dégonflage. Appuyez sur le bouton marche/arrêt pour démarrer le
dégonflage jusqu'à ce que tout l'air à l'intérieur du produit gonflable soit évacué. Éteignez la pompe à air pour
arrêter le dégonflage.
FONCTION DE SURVEILLANCE DE LA PRESSION SPÉCIALE
Cette pompe à air SUP20MAX est équipée d'une fonction spéciale de surveillance de la pression intelligente. Une
fois que la lecture de la pression atteint 0,6 PSI lors du gonflage dans la 1ère étape, le programme commencera à
surveiller l'augmentation de la pression. Si l'augmentation de pression est inférieure à 0,03 PSI sur une période
continue de 6 secondes, le contrôleur interne voit que le 1er étage atteint sa capacité de gonflage maximale. Ensuite,
la pompe recevra un signal pour arrêter le 1er étage et démarrer le gonflage du 2e étage par le compresseur à
piston.
Sur la base du nouveau programme, cette pompe peut fournir la meilleure efficacité de gonflage pour les SUP
gonflables, les bateaux, les cerfs-volants, les tentes et tout type de toits gonflables fournis à l'aide d'un adaptateur
de valve à air approprié et d'une pression maximale de 20 PSI satisfaite. Il permet à l'utilisateur d'économiser du
temps et de l'énergie pour gonfler rapidement le produit au PSI ciblé.
Pour utiliser au mieux cette fonction de manière appropriée, une source d'alimentation qualifiée en bon état est
nécessaire pour soutenir la pompe. Pendant tout le processus de gonflage, les utilisateurs doivent s'assurer de
l'étanchéité à l'air et de la minimisation des fuites d'air le long du passage d'air du port de gonflage de la pompe à

19 | P a g e
votre produit gonflable via le raccord du tuyau d'air.
Au cas où la pompe ne pourrait pas passer automatiquement au 2ème étage, l'utilisateur peut arrêter la pompe et
s'assurer que la pression de lecture de la chambre peut être supérieure à 0,6 PSI, et vous redémarrez la pompe pour
activer le 2ème étage manuellement. Si la pompe détecte une pression supérieure à 0,6 PSI au démarrage, elle
contournera le 1er étage et passera directement au 2e étage pour le pompage haute pression.
Conseils : si la 1ère étape ne peut pas démarrer correctement dans une situation inhabituelle, l'utilisateur peut
utiliser une pompe manuelle pour gonfler le produit à environ 1 PSI, puis utiliser cette pompe pour effectuer le reste
du processus de gonflage directement à partir de cette 2ème étape.
Lorsque la pression d'air est supérieure à 5 PSI, la pompe redémarre le programme de surveillance. Si le taux
d'augmentation de la pression commence à diminuer pendant une période de temps définie ou si la température
interne est supérieure à 85 Celsius (185 Fahrenheit), le mode de protection interne sera activé. La pompe s'arrêtera
automatiquement pour éviter un problème de surchauffe.
DÉPANNAGE
Rebranchez le cordon d'alimentation pour une vérification rapide avant le dépannage !
La plupart des problèmes peuvent être causés par une faible tension d'alimentation ou une connexion 12 V faible.
L'utilisation continue de la pompe dans de telles conditions peut facilement endommager le compresseur de 2ème
étage de la pompe en raison d'un problème de surchauffe. Avant de résoudre le problème de la source
d'alimentation inférieure, l'utilisateur ne doit pas utiliser la pompe dans le même état pendant plus de 3 minutes.
Les directives suivantes peuvent aider les utilisateurs à effectuer des étapes de dépannage de base.
▪Si ce n'est pas encore fait, utilisez la batterie de votre voiture comme source d'alimentation. Cette pompe a
besoin d'une bonne batterie pour fournir en permanence une sortie de 15 A pour sa consommation d'énergie
de 12 A. N'utilisez PAS un petit convertisseur 110V à 12V DC, même s'il a un taux de 15A.
▪Si la batterie de la voiture a plus de 2 ans ou achetée telle qu'utilisée, vous pouvez allumer le moteur lors du
pompage et constater la différence. Mieux, vous pouvez vérifier la tension de la batterie avec un multimètre
électrique numérique et vous assurer que la tension de la batterie est supérieure à 12 V.
▪Vous devriez vérifier l'étanchéité de votre tuyau d'air. Assurez-vous de mettre un joint torique de la bonne taille
sur l'adaptateur de valve. Lorsque vous éteignez la pompe avec une certaine pression restante dans la chambre
SUP, ne débranchez pas le tuyau, vous ne devriez pas entendre d'air s'échapper de la connexion des deux côtés
du tuyau. Vous pouvez également utiliser 5% d'eau savonneuse pour vérifier les fuites d'air.
▪Il est très important de régler votre prise 12V, vous pouvez faire briller la prise en utilisant du papier de verre.
L'allumage de la cigarette peut rendre le 12V chaussé avec une résistance électrique supplémentaire. Même un
GPS fonctionne bien, mais il peut ne pas être assez bon pour cette pompe car 12 ampères sont nécessaires.
Nous voulons donc que vous vérifiiez cette pièce ou que vous changiez une autre prise ou un autre véhicule
pour essayer.
Vous pouvez discuter avec nous pour tout autre problème. Sinon si votre pompe avait été vérifiée et qu'il n'y avait
plus de haute pression créée. nous pensons que votre pompe a été endommagée. Ensuite, vous pouvez nous
contacter directement par e-mail pour une réparation ou un remplacement. Vous pouvez trouver notre e-mail sur
le site Web de Seamax Marine ou le manuel d'utilisation de la pompe. Puisque nous ne pouvons pas vous donner
notre adresse e-mail à partir du message Amazon. Vous pouvez transmettre ce message à notre service client avec
votre numéro de commande d'origine. Et vous devrez peut-être payer les frais d'expédition et de manutention si
votre achat dure plus de 60 jours et retourner la pompe d'origine. Merci encore d'avoir contacté Seamax.

20 | P a g e
FAUTE
INSPECTION
SOLUTION
La pompe à air ne
peut pas démarrer
normalement.
1. La source
d'alimentation n'est
pas correctement
branchée.
2. Le fusible de la
fiche CC (7) est
grillé.
3. Surchauffe ou
surcharge.
1. Assurez-vous de vous connecter à la prise 12V DC.
2. Changez le fusible.
3. Retirez le capuchon de sable de l'entrée ou de la sortie de
la pompe. Refroidissez le moteur et redémarrez-le. Allumez la
pompe en l'air pour la forcer à refroidir rapidement.
Arrêt de la pompe
avant d'atteindre
la pression de
consigne
1. Vérifiez la tension
d'entrée, assurez-
vous qu'il n'y a pas
de problème de
tension faible
2. Vérifiez la
température
3. Autres problèmes
1. Si vous pouvez redémarrer la pompe, démarrez-la et
vérifiez la tension d'entrée avant l'arrêt de la pompe, assurez-
vous que la tension est comprise entre 9 et 15 V.
2. Si la température interne est trop élevée, la pompe
s'arrêtera et son écran affichera une surchauffe. Vous pouvez
donc arrêter de l'utiliser pour son refroidissement.
3. Contactez le service client Seamax –
support@seamaxcanada.com
Gonflage lent ou
anormal.
1. Vérifiez si le tuyau
est bouché ou
fissuré.
2. Le joint entre le
tuyau et la pompe à
air ou le produit
gonflable n'est pas
installé
correctement.
3. Assurez-vous que
la source
d'alimentation
répond aux
exigences de la
pompe 12V 15A
1. Changez le tuyau ou débouchez-le et vérifiez si le tuyau est
fissuré.
2. Réinstallez le tuyau ou l'adaptateur de valve, placez le joint
torique de la bonne taille
3. Si le problème ne peut pas être résolu, veuillez contacter le
fabricant ou son agent de service ou le personnel autorisé
similaire.
4. N'utilisez PAS de convertisseurs muraux compacts CA/CC
pour alimenter la pompe. Connectez l'adaptateur du chargeur
de voiture de la pompe directement à la prise du chargeur
d'une voiture. Ou utilisez une batterie au plomb externe d'au
moins 12V 7AH bien chargée avec le connecteur de batterie
12V en option.
RACCORD DE LA VANNE D'AIR
▪Cette pompe convient aux produits avec HR (Halkey-Roberts), Bravo ou soupape d'air similaire. Ce sont les valves
d'air les plus populaires pour les SUP gonflables et les planches à pagaie sur le marché actuel. Ce type de vanne
d'air a une goupille tournante centrale (vanne HR) ou une goupille de poussée (Bravo) contrôlant la position
ouverte / fermée de la vanne d'air. L'adaptateur de valve universel fourni avec la pompe doit s'y adapter.
▪Veuillez vous assurer que la valve à air est en position fermée lors du gonflage de la chambre à air. Sinon, de l'air
peut s'échapper de la valve lorsque le tuyau d'air est déconnecté. Notre pompe à air est livrée avec un
adaptateur de valve HR universel avec 3 joints toriques en caoutchouc de silicone d'épaisseur différente (3
mm/5 mm/6 mm). Le joint torique de 6 mm est pré-installé sur l'adaptateur de valve de tuyau d'air. Il devrait
en avoir un pour s'adapter au mieux à votre valve à air et étanche à l'air.
▪Si vous ne pouvez pas utiliser notre adaptateur de valve pour votre produit gonflable, vous devrez peut-être
couper le tuyau pour installer le vôtre à partir de la pompe manuelle d'origine. Vous pouvez utiliser le ruban
électrique pour assurer l'ajustement et l'étanchéité du diamètre. Vous pouvez également contacter Seamax
Marine pour appliquer un ensemble de tuyaux d'air libre pour cette modification.
Table of contents
Languages:
Other Seamax Water Pump manuals
Popular Water Pump manuals by other brands

Talon
Talon TP-50BS manual

EBARA
EBARA thebe 3TSM ci Instruction manual and warranty

Rossmax
Rossmax V5 user manual

Annovi Reverberi
Annovi Reverberi AR 245 LFP instruction manual

WITA
WITA go.future light 40 series TRANSLATION OF THE ORIGINAL INSTALLATION AND OPERATING INSTRUCTIONS

Homa
Homa GRP 56 ET Original instruction manual

Rapid
Rapid ABM 200 A-LKW manual

Zoeller
Zoeller ProPak 507 installation instructions

Ebsray
Ebsray Z Series Installation, operation & maintenance instructions

Leybold vacuum
Leybold vacuum RUVAC WS 251 operating instructions

Giant
Giant P200A-5100 Series Repair and operating instructions

STS
STS M2-G2 Operator's manual