FEATURES
The 715XS+TCR 2-way stainless steel ball valve is designed for the automatic shut-off of pipes with non-loaded
industrial fluids. It is a full-bore valve with an antistatic device. It is EC-approved. The ISO 5211 mounting pad
enables the TCR actuator to be directly assembled. The latter is suitable for indoor or outdoor (under shelter)
industrial use.
AVAILABLE MODELS
1.4408 stainless steel body.
1/2’’ to 3’’ diameters.
G thread connections
Supply voltages: 24 V DC, 24 V AC and 230 V AC.
LIMITS OF USE
Fluid pressure: PS
63 bar (20°C)
Fluid temperature: WT
- 10°C / +180°C
Ambient temperature
- 20°C / + 60°C
Service factor
S4 –50%
DIRECTIVES AND MANUFACTURING STANDARDS
OBJECT
Standard
ON
OBJECT
Standard
Pressure Equipment
Directive 2014/68/EC
1/2’’ to 1”: not subject
Final test
NKS 12266
1’’1/4 to 3’’: category III
TÜV 0035
Material certificate
NKS 10204
Size
EN 12516-1
Motorisation connection
ISO 5211:
Steel grades
EN 1503-1
0
10
20
30
40
50
60
70
80
-10 0 20 40 60 80 100 120 140 160 180
Pressure (bar)
Temperature (°C)
Operating range
3.1
Cert.
ISO
9001
IP
67
0035

715 XS VALVE WITH TCR ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
2/6
Ref.
FT715XS+TCR ENG
Rev.
04
Date
06/2020
CONSTRUCTION
No.
Name
Material
No.
Name
Material
1
Body
1.4408 SS
11
Lever
304 SS
2
Lateral end
1.4408 SS
12
Nut
304 SS
4
Seats
PTFE + +15% GF
13
Stop
304 SS
5
Stem
316 SS
14
Liner
PVC
6
Body gasket
PTFE
15
O-ring
FKM
7
Washer
PTFE
16
Slide
304 SS
8
Cable gland gasket
PTFE
17
Antistatic device
316 SS
9
Washer
304 SS
18
Spring
316 SS
10
Bellevile washer
301 SS
DIMENSIONS (mm)
DN
A
B
C
D
H
L
J
J1
d1
d2
SW
1/2’’
15
55
70.9
110
42.3
8
42
50
6
7
9
3/4’’
20
76
73.4
110
44.9
8
42
50
6
7
9
1‘‘
24.5
83
84.1
135
54
10
42
50
6
7
11
1’’ 1/4
32
91
89.3
165
59.2
10
50
70
7
9
11
1’’ 1/2
38
103
109.5
165
71.3
10
50
70
7
9
11
2’’
50
120
118.9
165
82.9
14.8
50
70
7
9
14
2“1/2
65
155
155
300
107
17.1
70
102
9
11
17
3”
80
182
165
335
117
17.1
70
102
9
11
17

715 XS VALVE WITH TCR ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
3/6
Ref.
FT715XS+TCR ENG
Rev.
04
Date
06/2020
TCR ELECTRICAL MOTORISATION
The TCR motorisation proposed as standard comprises:
- IP67 plastic housing for actuator and steel gear box,
- a safety coefficient of 1.3 minimum compared to the nominal torque of the valve,
- an upstream / downstream pressure difference ΔP=10 bar max.
The actuator's assembly is direct.
DN
Actuator
Power
230V AC / 24V AC-DC
Time
230V AC
Time
24 V AC-DC
Standard equipment of the actuator
1/4’’
TCR-02N
15
10s
10s
2 adjustable limit switches
2 dry auxiliary contacts
Thermal protection of the motor
2-3W anti-condensation resistance
Stand-by manual control with key
3D Position visual indicator
Electrical connection:
TRC02: 1 x PE M10 + 1.5m cable
TCR05: 1 x PE M20 + 1.5m cable
TCR11: 2 x PE M14 + 1.5 m cable
3/8’’
TCR-02N
15
10s
10s
1/2’’
TCR-02N
15
10s
10s
3/4’’
TCR-02N
15
10s
10s
1‘‘
TCR-02N
15
10s
10s
1’’ 1/4
TCR-02N
15
10s
10s
1’’ 1/2
TCR-05N
25
12s
12s
2’’
TCR-05N
25
12s
12s
2’’ 1/2
TCR-05N
25
12s
12s
3‘‘
TCR-11N
100
10s
10s
For any other operating conditions, please contact us.
* indicative time for actuator running empty
MOTORISATION OPTIONS
There are many options, so please contact our sales service for more information on these:
1
100mm high height adjustment for installing thermal insulation
2
Actuator dimensioned for an upstream / downstream pressure difference ΔP greater than 10 bar
3
NF actuator –return via condenser –TCR-KT32
4
High-speed actuator - TRC-NH
5
Smart actuator with manoeuvring time adjustment - TCR-C
6
Control actuator –TCR-T
7
NF control actuator –return via condenser –TCR-T-KT32
8
Field bus actuator - TCR-B
9
Actuator with in-built timer –TCR-D
10
Wireless actuator –TCR-R

715 XS VALVE WITH TCR ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
4/6
Ref.
FT715XS+TCR ENG
Rev.
04
Date
06/2020
ASSEMBLY AND MAINTAINANCE INSTRUCTIONS
1 - Installation
1.1 - Checks
oCheck that the material of the valve body is chemically compatible with the fluid.
oCheck that the pressure and service conditions are compatible with the (P, T) diagram of the valve. See
§ “Service limits”
oCheck that the fluid is clean and free of particles. The latter could scratch the ball and damage the seats,
hence causing the valve to leak. If need be, install an upstream filter.
oCheck that there is no risk of thermal expansion of the fluid, which could damage the seats. In the open
position, a hole at the top of the ball balances the pressures between the body cavity and the flow of
the fluid. As an option, we recommend a relief hole upstream of the valve for balancing the pressures
for fluids such as ammonia, LPG, chlorine, etc.
oCheck that the valve is not used for flow or pressure control since it is not intended for this use and
there is a risk of premature wear of the seats, in particular in the event of high pressure and/or
temperature. For this special application, preferably use our ‘”V-port” 746XS version with a V-shaped
hole in the ball. Please contact us.
oCheck that the valve is not used on a gas which might condense at certain times during the process. In
such a case, the pressure within the body cavity could become negative, which could lead to a significant
deformation of the seats. Please contact us.
oStatic electricity: the valve will be supplied with a ball-stem-body internal electrical continuity tester. If
the service conditions require the electrical continuity of the installation, check its earthing.
oIf the valve is installed in an explosive zone, you must follow the additional “IMEVMATEX” instructions.
1.2 - Storage before installation
oFollow our general “IMESTOCK” instructions for storage.
1.3 - Installation
oBefore any installation, isolate the piping upstream and downstream, depressurize the piping and bring
the installation to ambient temperature. Carefully clean the piping of any particle (foreign body, dust,
rust, etc.) or shavings by water rinsing or air blowing.
oFor valves with a size above DN50, plan to use a hoist.
oRemove the protective tips from the valve ends.
oCheck the cleanliness of the internal surfaces of the valve and if need be, clean them.
oDirection of mounting: the valves do not have a preferred direction of mounting, unless a relief hole
was drilled into the ball.
oCheck the perfect alignment and the proper support of the pipe installation upstream and downstream
of the valve. Alignment defects cause mechanical deformations which can block the valve or lead to
leaks at the body gaskets.
oCheck that the standards for the valve internal thread and pipe thread are the same.
oCover the pipe threads using a sealing material (tow, PTFE tape, sealing glue, etc.) which is suitable for
the fluid.
oScrew the tube into the valve end clockwise, as shown in the diagram below.
oCheck the sealing of the connection using a suitable test (hydrostatic test or leak detection spray).
oHydraulic test of the installation:
oValves were tested at the factory at 1.5 x WP.
oIf a hydrostatic test is carried out on the installation, do not exceed the authorised pressure.

715 XS VALVE WITH TCR ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
5/6
Ref.
FT715XS+TCR ENG
Rev.
04
Date
06/2020
2 - Service
oIf a hot fluid flows across the valve, do not touch the valve surface.
oAlways operate the valve slowly and smoothly.
oOpening clockwise, closing anti-clockwise.
3 - Servicing
3.1 - Frequency of servicing
oThe servicing frequency depends upon the use of the valve, of the type of fluid, of its velocity, of its
frequency of operation, of the cycles of rise and fall in pressure and temperature.
oBefore any intervention, isolate the upstream and downstream pipe installation using the valves
provided for this purpose. Depressurize the pipe installation and bring it to ambient temperature.
oIf the lever has to be removed, do that before disassembling the body.
oTo remove the central body, unscrew the lateral end (item 2).
oTo remove the ball from the body, turn the stem by a quarter turn.

715 XS VALVE WITH TCR ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
6/6
Ref.
FT715XS+TCR ENG
Rev.
04
Date
06/2020
3.2 –Inspecting the state of the valve and possible repair
oCheck the state of the ball (Item 4): it has to be clean and unscratched. If the cleaning or polishing is not
possible, replace it (see the § on spare parts).
oCheck the state of the seats (3.1 and 3.2): they must not be deformed, nor scratched, nor worn, or dirty.
Otherwise, replace them with parts from the gasket kit.
oCheck the state of the packing gland (7.8 and 9): no leak should be found at the stem and the rings
should not be excessively worn. If need be, replace the gaskets.
oCheck the state of the body gasket (6.1 and 6.2). Replace it, if need be.
oReassemble the different parts of the valve, following the tightening torques shown in the table below.
oCheck that the stem manoeuvring is smooth. Perform about ten manoeuvres.
TABLE OF THE TIGHTENING TORQUES OF THE TIE-BOLTS AND OF THE LEVER NUT
DN
Lever nut (Nm)
1/4’’ – 6
4
3/8’’ – 10
4
1/2’’ - 15
4
3/4’’ - 20
4
1’’ - 25
4.5
1’’1/4 - 32
4.5
1’’1/2 - 40
5.5
2’’ - 50
5.5
2’’1/2 - 65
7
3’’ - 80
7
4 ‘’ - 100
7
SPARE PARTS
DN
Gasket kit
Ball
Lever
Reference mark
6-7-8-15
4
11
1/2’’ - 15
Please contact us.
980032
982802
3/4’’ - 20
Please contact us.
980033
982802
1’’ - 25
Please contact us.
980034
982804
1’’1/4 - 32
Please contact us.
980035
982804
1’’1/2 - 40
Please contact us.
980036
982806
2’’ - 50
Please contact us.
980037
982806
2’’1/2 - 65
Please contact us.
Please contact us.
982808
3’’ - 80
Please contact us.
Please contact us.
982808
4 ‘’ - 100
Please contact us.
Please contact us.
982808


TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
1/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
FEATURES
The TCR-N electric actuators are intended for motorising ¼ turn valves with a torque of 15, 20, 50 or 110 Nm. With a
compact construction and plastic housing, they are especially well suited for motorising small size ball valves. Several
variants offer advanced functions. IP67 leak-tightness: to be used indoors and, possibly, outdoors under a shelter. Possible
installation in parallel. Manual control with a key.
AVAILABLE MODELS
Supply voltages: 230V AC, 24V AC/DC, 12V DC.
LIMITS OF USE
MECHANICAL FEATURES
Actuator
TCR 02N
TCR 05N
TCR 11N
Torques (Nm)
15
20
20
50
110
Voltage
12V DC
24V AC-DC
95-265V AC-DC
12VDC
24V AC-DC
95-265V AC-DC
12V DC
24V AC-DC
95-265V AC-DC
Manoeuvring time (s)
15
10
10
12
12
12
10
10
10
ISO 5211:
F03/F05 - star 11
F05/F07 - star 14
F05/F07 - star 17
ELECTRICAL FEATURES
Actuator
TCR 02N
TCR 05N
TCR 11N
Motor protection
Thermal switch
Limit switches
2 adjustable switches
Auxiliary switches
2 adjustable dry switches
Anti-condensation
integrated
Electrical connection
PE M10 + 1.5m cable
PE M20 + 1.5m cable
2 x PE M14
Actuator
TCR 02N
TCR 05N
TCR 11N
Voltage
12V DC
24V AC-DC
95-265V AC-DC
12V DC
24V AC-DC
95-265V AC-DC
12V DC
24V AC-DC
95-265V AC-DC
Power (W)
15
15
15
25
25
25
100
100
100
Current (A)
1,5
1,5
0,09
1,67
0,18 - 0,37
2,5
0,3 - 0,6
Fuse Protection (A)
5
5
1
8
1 - 2
5
2 - 3
IP Code
IP 67
Ambient temperature
- 20°C / +60°C
Service factor
S4-50%
Gear box
treated steel pinions
Torques
15 - 20 - 50 - 110 Nm
Angle of rotation
90° +/- 2°
Declutching
without
Override control
By key
IP
67
ISO
9001

TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
2/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
CONSTRUCTION (TCR-02N)
DIMENSIONS (mm)
TCR-02N
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 4
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 0.620

TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
3/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
CONSTRUCTION (TCR-05N)
DIMENSIONS (mm)
TCR-05N
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 6
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 1.800

TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
4/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
CONSTRUCTION (TCR-11N)
DIMENSIONS (mm)
TCR-11N
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 6
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
X 2Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 2.200
11
Cable gland unit
Plastic (ABS)

TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
5/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
WIRING DIAGRAM
SWITCH SETTING
BU
Neutral (Blue)
RD
Closing control (Red)
BK
Opening control (Black)
WT
Information return to common (White)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
GY
Opening return information (Grey)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
BR
Closing return information (Brown)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
Y/G
Earth (Yellow / Green)

TCR-N ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
6/6
Ref.
FT2411 ENG
Rev.
02
Date
06/2020
TROUBLESHOOTING
Defect met
Cause of defect
Method of solving
Inactive actuator
Non-connected electrical grid.
Connect to the electrical grid.
Wrong voltage.
Check the actuator’s voltage.
Motor overheating.
Check the torque on the valve.
Faulty connection.
Check the connection to the terminal box.
Damaged start capacitor.
Contact the supplier for repair.
No switch signal
Faulty connection.
Check the connections.
Damaged microswitch
Change the microswitch
Valve that is not fully
closed
Use the return signal from the actuator
check.
Receiving a return signal does not mean
that the actuator is fully closed, hence do
not cut the power supply.
The hysteresis increases due to wear or
between the actuator and the valve’s stem.
Readjust the limit cams.
Contact the supplier for repair.
Presence of humidity or
water in the actuator
Unsuitable cable cross-section being used.
Contact the supplier for repair.
The cable connection is not leak-tight.
Worn sealing gaskets.
Loose cover screws.
Dry the internal parts and tighten the
cover screws.

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
1/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
FEATURES
The TCR-N-KT electric actuators are intended for motorising ¼ turn valves with a torque of 15, 45, 95 or 110 Nm. Capacitor
return function: the closing manoeuvre is provided by a capacitor. With a compact construction and plastic housing, they
are especially well suited for motorising small size ball valves. IP67 leak-tightness: to be used indoors and, possibly,
outdoors under a shelter. Possible installation in parallel. Manual control with a key.
AVAILABLE MODELS
Supply voltages: 230V AC, 24V AC/DC.
LIMITS OF USE
MECHANICAL FEATURES
Actuator
TCR 02N-KT32
TCR 05N-KT32
TCR 11N-KT32
Torques (Nm)
15
45
110
95
Voltage
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
Manoeuvring time (s)
15
15
12
12
10
10
ISO 5211:
F03/F05 - star 11
F05/F07 - star 14
F05/F07 - star 17
ELECTRICAL FEATURES
Actuator
TCR 02N-KT32
TCR 05N-KT32
TCR 11N-KT32
Motor protection
Thermal switch
Limit switches
2 adjustable switches
Auxiliary switches
2 adjustable dry switches
Anti-condensation
integrated
Electrical connection
PE M10 + 1.5m cable
PE M20 + 1.5m cable
2 x PE M14
Actuator
TCR 02N-KT32
TCR 05N-KT32
TCR 11N-KT32
Voltage
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
Power (W)
36
36
40
40
100
100
Current (A)
1,5
0,09
1,8
1,6
2,5
0,26 - 0,52
Fuse protection (A)
5
1
10
2
5
2
IP Code
IP 67
Ambient temperature
- 20°C / +60°C
Service factor
S4-50%
Gear box
treated steel pinions
Torques
15 - 45 - 95 - 110 Nm
Angle of rotation
90° +/- 2°
Declutching
without
Override control
By key
IP
67
ISO
9001

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
2/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
CONSTRUCTION (TCR-02N-KT32)
DIMENSIONS (mm)
TCR-02N-KT32
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 4
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 0.620

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
3/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
CONSTRUCTION (TCR-05N-KT32)
DIMENSIONS (mm)
TCR-05N-KT32
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 6
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 1.800

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
4/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
CONSTRUCTION (TCR-11N-KT32)
DIMENSIONS (mm)
TCR-11N-KT32
No.
Name
Material
No.
Name
Material
1
Casing + lid
Plastic (ABS)
6
Rating plate
PVC
2
Position indicator
Polycarbonate plastic
7
Key support
Plastic (ABS)
3
Screw x 6
Aisi 304
8
Hex key
Steel
4
Backup control stem
Aisi 304
9
X 2Packing gland
Nylon
5
Gasket
NBR
10
Cover gasket
NBR
Weight (kg): 2.200
11
Cable gland unit
Plastic (ABS)

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
5/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
WIRING DIAGRAM
SWITCH SETTING
BU
Neutral / V (blue)
RD
Phase / V+ (Red)
BK
Control (Black)
WT
Information return to common (White)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
GY
Opening return information (Grey)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
BR
Closing return information (Brown)
Dry switch: 230V AC max 50 mA
230V DC max 500 mA
Y/G
Earth (Yellow / Green)

TCR-N-KT CAPACITOR RETURN ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 70 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
6/6
Ref.
FT2412 ENG
Rev.
03
Date
06/2020
TROUBLESHOOTING
Defect met
Cause of defect
Method of solving
Inactive actuator
Non-connected electrical grid.
Connect to the electrical grid.
Wrong voltage.
Check the actuator’s voltage.
Motor overheating.
Check the torque on the valve.
Faulty connection.
Check the connection to the terminal box.
Damaged start capacitor.
Contact the supplier for repair.
No switch signal
Faulty connection.
Check the connections.
Damaged microswitch
Change the microswitch
Valve that is not fully
closed
Use the return signal from the actuator
check.
Receiving a return signal does not mean
that the actuator is fully closed, hence do
not cut the power supply.
The hysteresis increases due to wear or
between the actuator and the valve’s stem.
Readjust the limit cams.
Contact the supplier for repair.
Presence of humidity or
water in the actuator
Unsuitable cable cross-section being used.
Contact the supplier for repair.
The cable connection is not leak-tight.
Worn sealing gaskets.
Loose cover screws.
Dry the internal parts and tighten the
cover screws.

TCR-NH HIGH-SPEED ELECTRICAL ACTUATOR
Information given as an indication only, and subject to possible modifications
SECTORIEL S.A.
45 rue du Ruisseau
38290 SAINT QUENTIN-FALLAVIER –FRANCE
Telephone: +33 4 74 94 90 - Fax: +33 4 74 94 13 95
www.sectoriel.fr / Email : sectoriel@sectoriel.fr
Pages
1/6
Ref.
FT2413 ENG
Rev.
03
Date
06/2020
FEATURES
The TCR-NH electric actuators are intended for motorising ¼ turn valves with a torque of 15, 50 or 80 Nm. High-speed
function: 6-second manoeuvre time. With a compact construction and plastic housing, they are especially well suited for
motorising small size ball valves. IP67 leak-tightness: to be used indoors and, possibly, outdoors under a shelter. Possible
installation in parallel. Manual control with a key.
AVAILABLE MODELS
Supply voltages: 230V AC, 24V AC/DC.
LIMITS OF USE
MECHANICAL FEATURES
Actuator
TCR 02NH
TCR 05NH
TCR 11NH
Torques (Nm)
15
50
80
Voltage
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
Manoeuvring time (s)
6
6
5
5
5
5
ISO 5211:
F03/F05 - star 11
F05/F07 - star 14
F05/F07 - star 17
ELECTRICAL FEATURES
Actuator
TCR 02NH
TCR 05NH
TCR 11NH
Motor protection
Thermal switch
Limit switches
2 adjustable switches
Auxiliary switches
2 adjustable dry switches
Anti-condensation
integrated
Electrical connection
PE M10 + 1.5m cable
PE M20 + 1.5m cable
2 x PE M14
Actuator
TCR 02NH
TCR 05NH
TCR 11NH
Voltage
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
24V AC - DC
95-265V AC-DC
Power (W)
25
25
40
40
100
100
Current (A)
1,5
0,12
1,8
1,8
5
0,52
Fuse protection (A)
5
1
10
10
10
2
IP Code
IP 67
Ambient temperature
- 20°C / +60°C
Service factor
S4-50%
Gear box
treated steel pinions
Torques
15 - 50 - 80 Nm
Angle of rotation
90° +/- 2°
Declutching
without
Override control
By key
IP
67
ISO
9001
Table of contents
Other Sectoriel Control Unit manuals
Popular Control Unit manuals by other brands

Sony
Sony Ipela Quick reference guide

Siemens
Siemens SINUMERIK 840D sl Commissioning manual

Franke
Franke DVS AC17-080 Installation & operating instructions

Intermatic
Intermatic ET9232 Replacement instructions

Villeroy & Boch
Villeroy & Boch Heating Control Start-up and operation

Polycom
Polycom RMX DOC2560B Getting started guide