manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SENSIT Technologies
  6. •
  7. Security Sensor
  8. •
  9. SENSIT Technologies SENSIT TKX User manual

SENSIT Technologies SENSIT TKX User manual

SENSIT®TKX
Combustible Gas Leak Detector
INSTRUCTIONMANUAL
Your SENSIT®TKX instrument is warranted to
be free from defects in materials and work-
manship for a period of one year after pur-
chase (excluding sensor and batteries). If
within the warranty period your instrument
should become inoperative from such de-
fects, the unit will be repaired or replaced at
our option. This warranty covers normal use
and does not cover damage which occurs in
shipment or failure which results from alter-
ation, tampering, accident, misuse, abuse,
neglect, or improper maintenance. A pur-
chase receipt or other proof of date of origi-
nal purchase may be required before war-
ranty performance will be rendered.
Instruments out of warranty will be repaired
for a service charge. Return the unit post-
paid and insured to:
SENSITTECHNOLOGIES
ATTN:ServiceDept.
851 Transport Drive
Valparaiso, IN 46383
This warranty gives you specific legal rights
and you may also have other rights which
vary from state to state.
WARRANTY&REPAIR POLICY
Sensit®isaregisteredtrademarkofJAndN. 2009 UL V2
Approved UL913, For
Class 1, Division 1,
Groups C & D
hazardous locations
when used with
alkaline batteries.
7WA6
C
L
A
S
S
I
F
I
E
D
Warning:
To prevent ignition
offlammable or
combustible
atmospheres,
disconnect power
before servicing.
Read and understand
instructions before use.
1.888.610.7664
info@Sensit-Direct.com
SENSIT-Direct.com
CONTENTS
1. Specifications
2. ProductFeatures
2. Accessories and Parts
3. GeneralDescription
3. SafetyApproval
4. Operation
5. BatteryReplacement
6. OperationCheck
6. SensorReplacement
7. WarrantyandRepairPolicy
PowerSupply: 3 “C”Alkaline Batteries
Sensor: Solid State
Sensitivity: 20ppm Methane
Warm up: Approx. 1 Minute
ResponseTime: Instantaneous
Duty Cycle: Continuous
BatteryLife: Approx. 30 Hours
Size: 3.5” x 10” x 1.6”
(89 x 254 x 40 mm)
Weight: 1.3 lbs. (591 g)
ProbeLength: 16”
Approvals: UL913 Intrinsically Safe
SPECIFICATIONS
OPERATIONCHECK
Firstfollow steps1,2 and 3(page4) inthe
Operationssection. Thenexposethesen-
sortoaknown gassourcesuchasan unlit
butane lighter. The tick should increase
when the gas is applied. The tick will de-
creasewhenthe gas is removed.
Iftheunit fails to respond, the sensor may
needreplacingor the unit may need to be
sentinfor repair (see below).
SENSORREPLACEMENT
61
Thissafetysymbolisusedtoindicateapotentially
hazardoussituationwhich,ifnotavoided,mayresult
inminorormoderateinjury.
CAUTION:
CAUTION This instrument must be
only repaired by a factory authorized re-
pairtechnician.
1. Turnthe unitoff
2. Pull off the sensor cap
3. Unplugtheoldsensoranddiscard
4. Lineupreferencetabonsideofsensor
with reference mark ( ) on sensor
circuit board and plug in sensor
5. Replacesensor cap
6. Turnonunitandperform“Operation
Check”
1.888.610.7664
info@Sensit-Direct.com
SENSIT-Direct.com
PRODUCTFEATURES
2
5
OPERATIONS(cont.frompage4)
5. When this instrument is used in noisy
environments, look at the red leak indica-
tor LED that flashes more rapidly as the
tick rate increases. You can also use the
suppliedearphone.
6. If the green LED does not illuminate or
blinks, the batteries must be replaced.
7. If the instrument does not perform or it
hasbeen damaged, testtheinstrumentby
followingthe“operationcheck”procedure
in this manual.
TICKADJUST GOOSENECK
CLIP
BATTERY
COMPARTMENT
REDLEAK
INDICATORLED
POWEROFF/ON
GOOSENECK
GREEN
READYLED
ACCESSORIES and PARTS
STANDARDACCESSORIES(INCLUDED)
Carrying Pouch 360-00002
Instruction Manual 750-00043
Alkaline Batteries 310-00004
OPTIONALACCESSORIES/PARTS
Sensor 375-2611-01
BATTERYREPLACEMENT
Ifthe greenLEDfails toilluminate,the bat-
teriesneedreplacement. Depressthelatch
usingacoinand slidethebattery compart-
mentcover off. Replace the batteries with
3“C”alkalinebatteries.
When replacing the batteries observe the
polarity markings on the sides of the bat-
tery compartment. A fresh set of alkaline
batteriesshouldoperatetheunitforapproxi-
mately 30 hours.
SENSIT® TKX
SPEAKER
(ON BACK)
EARPHONE
JACK
SOLIDSTATE
SENSOR
1.888.610.7664
info@Sensit-Direct.com
SENSIT-Direct.com
The SENSIT®TKX instrument is an ad-
vanced state-of-the-art leak detector ca-
pableofdetectingmanycombustible,non-
combustible and toxic gases.
TheSENSIT®TKX solidstatesensorissen-
sitive to most combustible and/or toxic
gases.
A partial list of these gases is:
Acetone, Alcohol, Ammonia, Steam, Bu-
tane,Gasoline,JetFuel,HydrogenSulfide,
smoke,IndustrialSolvents,Methane, Lac-
quer Thinner, Naphtha, Propane, Natural
Gas.
3
GENERALDESCRIPTION
4
OPERATIONS
1. Turn the unit on in an uncontaminated
environmentbymovingtheswitchfromthe
“OFF”tothe “ON” position.
2. The green ready LED will illuminate if
thereisample batterypower. TheredLED
may flicker and the tick may sound during
the warm up. To silence the tick, rotate
the tick wheel fully counterclockwise.
3.Adjustthe “TICKADJUST”byrotatingit
inaclockwisedirectionuntila uniform tick
begins to sound. A uniform tick rate indi-
cates a fully warmed up instrument. The
redLED will flashatthesame time the tick
sounds.
4.Approachsuspectedleakareas withthe
sensor until the tick begins to increase.
When the tick increases do not move the
sensor from the suspected leak area, ro-
tate the tick adjust slightly counterclock-
wise to slow the ticking sound and con-
tinue to approach the leak. Continue to
use this method to pinpoint the leak.
REMEMBER:Anincreaseintickindicates
youare approaching a leak, a decreasein
tick indicates you are moving away.
This instrument is not to be used as a
carbon monoxide investigative tool or
to quantify any gas concentration.
CAUTION
SAFETYAPPROVAL
SENSIT®TKX isapprovedbyUnderwriters
Laboratories to UL913, for Class II
II
I,
Division 1, Groups C & D hazardous
locations when used with Duracell™
MN1400Kor equivalent alkalinebatteries. (Operationscontinuedonpage5)
1.888.610.7664
info@Sensit-Direct.com
SENSIT-Direct.com

Other SENSIT Technologies Security Sensor manuals

SENSIT Technologies ULTRA-TRAC APL User manual

SENSIT Technologies

SENSIT Technologies ULTRA-TRAC APL User manual

SENSIT Technologies IRED User manual

SENSIT Technologies

SENSIT Technologies IRED User manual

Popular Security Sensor manuals by other brands

elsner elektronik Intra-Sewi KNX L-Pr Installation and adjustment

elsner elektronik

elsner elektronik Intra-Sewi KNX L-Pr Installation and adjustment

SGB VL Series Documentation

SGB

SGB VL Series Documentation

AEMC 6681 user manual

AEMC

AEMC 6681 user manual

IFM Electronic efector300 SI0104 operating instructions

IFM Electronic

IFM Electronic efector300 SI0104 operating instructions

Deteck DT10C manual

Deteck

Deteck DT10C manual

teko Astra-MA user guide

teko

teko Astra-MA user guide

Risco iWISE RWT92043300C quick start guide

Risco

Risco iWISE RWT92043300C quick start guide

Bosch CS LD 1.0 Operator's manual

Bosch

Bosch CS LD 1.0 Operator's manual

SubSurface Instruments AquaTrac user manual

SubSurface Instruments

SubSurface Instruments AquaTrac user manual

Vega VEGAPULS C 23 operating instructions

Vega

Vega VEGAPULS C 23 operating instructions

schmersal RSS 36-D-R-ST-DU manual

schmersal

schmersal RSS 36-D-R-ST-DU manual

UniPOS FD 8030 instruction manual

UniPOS

UniPOS FD 8030 instruction manual

Roland Double Sheet Detector I100 manual

Roland

Roland Double Sheet Detector I100 manual

Detection Systems DS1520 installation instructions

Detection Systems

Detection Systems DS1520 installation instructions

IMI SENSORS 682B05 operating guide

IMI SENSORS

IMI SENSORS 682B05 operating guide

INFRARED CAMERAS SOUND DETECTAI user manual

INFRARED CAMERAS

INFRARED CAMERAS SOUND DETECTAI user manual

Argus PiCUS TMS 3 Applications manual

Argus

Argus PiCUS TMS 3 Applications manual

Guardian 10917 user manual

Guardian

Guardian 10917 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.