Sepson YM9G User manual

Features
uHour, minute and small second disk or hands
uDate
u Stopwatch
• 4Stopwatchdiskor hands: 1/20-second, second, minute hand and hour disk or hand.
• The stopwatch can measure up to 11:59' 59" 95 in 1/20-second increments.
• Splittimemeasurementisavailable.
N 1 2
N: Normal position
1: First click position
2: Second click position
Crown
MovementSize 12'"
Outside Diameter ø27.60mm(12H-6H)x24.00mm(3H-9H)
Casing Diameter ø27.00mm (12H-6H)
Height 4.34mm(Includingbattery)
Battery SR927SW
BatteryLife Approximately3years
A
B
u BatteryLifeIndicator
Whenthebatterynearsitsend,thesmallseconddiskorhandmovesattwo-secondintervalsinsteadofthe
normalone-secondintervals.Inthatcase,havethebatteryreplacedwithanewoneassoonaspossible.
Note: The watch remains accurate while the small second disk or hand is moving at two-second intervals.
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
STOPWATCH 1/20-second disk or hand
Minute hand
Date
Small second disk or hand
Hour hand
STOPWATCH Hour disk or hand
STOPWATCH Minute hand
STOPWATCH Second hand
CA L .Y M 9G
1/20 SECOND CHRONOGRAPH 1/4
Instructions

How to set time and date
• Turnthecrownclockwiseuntilthepreviousday’s
date appears.
Note: Do not set the date between 9:00 PM and 1:00 AM. Otherwise,
the date may not change properly.
Note: When the stopwatch is or has been measuring or is stopped,
if the crown is pulled out to the 2nd click position, it will
automatically reset the Stopwatch hands to "0".
Push back to
Normal position
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
5
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
5
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
1
3
2
4
5
N 12
N 1 2
N1 2
CA L .Y M 9G
1/20 SECOND CHRONOGRAPH 2/4
Instructions
• Pullthecrownouttothe1stclickposition.
• Pullthecrownouttothe2ndclickpositionwhen
the second hand is at the 12 o'clock position.
• Turnthecrowntosetthehourandminutehands.
• Turnthecrownclockwisetoadvancethehourand
minutehandspast12:00midnight.Thiswilladvance
the date to the current date.
• Take AM/PM into consideration when setting the
hour and minute hands to the desired time.
• Pushthecrownbacktothenormalposition.
Recommend:
• Whensettingtheminutehand,rstadvanceit4to5minutes
ahead of the desired time and then turn it back to the exact
minute.
Pull out to
1st position
Pull out to
2nd position
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
6
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
6
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40

How to use stopwatch functions
• Thestopwatchcanmeasureupto11:59'59"95in1/20secondincrements.
• Whenthemeasurementreaches12hours,thestopwatchautomaticallystopscounting.
• Splittimemeasurementisavailable.
•Thestopwatch1/20-seconddiskorhandiscapableoftiming10minutes.(1secondx600times)
•Thestopwatchseconddiskorhandiscapableoftiming12hours.(60secondsx720times)
◆ Movement of the stopwatch 1/20-second
• Afterthestopwatchisstarted,thestopwatch1/20-seconddiskor handmovesforabout10minutesand
automaticallystopsatthe“0”position.
• When the measurement is stopped or split time is measured, the stopwatch 1/20-second disk or hand
movestoindicatetheelapsed1/20seconds.
• Afterthestopwatchisrestartedorsplittimeisreleased,thestopwatch1/20-seconddisk or handmovesfor
about10minutesandstopsautomatically.
• Inthesamemanner,ifthestopwatchisstoppedandrestartedrepeatedlyorsplittimeismeasuredand
released repeatedly, the stopwatch 1/20-second disk or hand moves for about 10 minutes and stops
autom at ica lly.
* Before using the stopwatch, be sure to check that the crown is set at the normal position and that the
stopwatch disk or handsareresettothe“0”position.
Note: If the stopwatch disk or hands do not return to the “0” position when the stopwatch is reset to “0”, follow the
procedure in "Stopwatch disk or hand position adjustment".
Standard Measurement
BA A
Start Stop Reset
Accumulated Elapsed Time Measurement
A A A BA
Start Stop Restart Stop Reset
Split Time Measurement
AB
AB B
Split Split
Release
Stop Reset
Start
Note: Measurement and release of split time can be repeated by pressing Button “B.”
B
A
START
STOP
RESTART
SPLIT
SPLIT RESET
RESET
Measurement of Two Competitors
AB A B B
Start ResetFinish Time
of 1st
Competitor
2nd
Competitor
Finishes
Finish Time
of 2nd
Competitor
Note: Restart and stop of the stopwatch can be repeated by pressing Button “A.”
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
STOPWATCH
1/20-second disk
or hand
STOPWATCH
Hour disk or hand
STOPWATCH
Minute hand
STOPWATCH
Second hand
CA L .Y M 9G
1/20 SECOND CHRONOGRAPH 3/4
Instructions

Stopwatch hand position adjustment
Ifthestopwatchhandsarenotinthe“0”position,followtheproceduresbelowtosetthemtothe“0”position.
• Pullthecrownouttothe2ndclickposition.
Note: While the stopwatch is running or has been stopped while
running, if the crown is pulled out to the 2nd click position, the
stopwatch will be automatically reset.
• PressButton“A”for2seconds.
- The stopwatch 1/20-second disk or hand turns a full
roundandcannowbesettocorrectposition.
• PressButton“B”repeatedlytosetitto“0”position.
Note: The stopwatch 1/20-second disk or hand moves quickly if
Button "B" is kept pressed.
Note: The stopwatch second hand moves quickly if Button "B" is
kept pressed.
• PressButton“A”for2seconds.
- The stopwatchsecond handturnsafullround andcan
nowbesettothecorrectposition.
• Press Button “B” repeatedly to set the hand to the “0”
position.
Note: The stopwatch hour disk or hand and minute hands move
quickly if Button "B" is kept pressed.
• PressButton“A”for2seconds.
- The stopwatch hour disk or hand and minute hand can
nowbesettothecorrectposition.
• PressButton“B”repeatedlytosetthestopwatchhour
diskorhandandminutehandtothe“0”position.
• Pushthecrownbacktothenormalposition.
Push back to
Normal position
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
B
A
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
B
A
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
B
A
4
5
5
0
5
5
6
0
1
0
1
5
5
4
0
3
5
3
0
2
5
2
0
31
S.EPSON
YM9G
45 15
60
30
0.5
0.0
0.2
0.1
0.3
0.4
12
10
8
4
2
11
9
7
5
3
1
0.6
0.7
0.8
0.9
50
20
10
55
45
35
25
15
5
0
3
0
6
40
Stopwatch
1/20-second
disk or hands
Stopwatch
second hand
Stopwatch hour
disk or hand
and minute hand
2
43
The disk or hands can be readjusted
in the following order by pressing
Button "A" for 2 seconds.
12
34
5
N 1 2
N1 2
CA L .Y M 9G
1/20 SECOND CHRONOGRAPH 4/4
Instructions
Press A
2 sec.
Press A
2 sec.
Press A
2 sec.
Pull out to
2nd position