setro Minik 10 User manual

CABINETS | LOCKERS | BOXES
Operating
manual
The easy lock
in every aspect

Operating manual
Introduction
Description
Password Types
Operating Modes
Locker Mode (Multiple User Mode)
Personal Mode
Opening With User Password
Changing User Password
What If Forget The Passwords
Service Password
Opening With Service Password
Changing Service Password
Master Password
Opening With Master Password
Changing Master Password
Programming The miniK10
Accessing The Program Menu
Program Table
Programming Option Denitions
Changing The Battery
Maintenance
General Warnings
Cams
Other
Light And Audio Notication
Limited Warranty
Liability Limits
Technical Specications
Quick Info
Installation
Installation Overview
Mounting on Left & Right Door
Mounting Template
Joint erect lock assembly measurements
Recessed cover assembly measurements
Overlapping / external cover assembly measurements
Replacing existing lock
New Install
Warnings for mounting
3
4
4
4
4
5
5
5
6
6
6
6
7
7
7
7
7
9
9
9
10
10
10
11
12
12
12
12
13
15
16
19
20
21
22
23
23
24
Index

1. Red LED
2. Green LED
3. Keypad
4. Lock Body
5. Closing Position
6. Handle Indicator
7. Opening Position
8. Handle
9. Mounting Screw
Emergency
Battery
Back Up
10. Lock Body
11. Battery Cover
12. Battery Cover Screw
13. ID Label
14. Hand Knob Frame
15. Cam
16. Cam Screw
17. Cylinder Nut, R/L Stop Cam
Front Back
19
10
11
12
13
14
15
16
17
2
3
4
5
15
6
7
8
Introduction
3

miniK10 electronic cabinet lock with master/manager code, personal use function-
ality, and up to 10 years battery life. miniK10 can be installed for both right and left
hand installations - anywhere that needs exibility of master/ manager codes. The
eco-friendly miniK10 oers both convenience of far lessfrequent battery changes and
a more environmentally friendly solution.
The miniK10 has three potential password levels -
1. User password
2. Service password (must activate in Program 5.1)
3. Master password
The user and master passwords should be changed prior to installation and tested.
Write down new passwords and keep in a safe place. It is not possible to open lock if
you forget your password.
The miniK10 can operate in two dierent modes:
1. Personal Mode - Fixed password.The user will open lock each time with the
same own password.
2. Locker Mode (factory default) - user enters in their code when lock is in
unlocked position and rotates handle to lock. Upon returning uses same code
to open. Next user can repeat the process with their own unique password.
In locker mode, opening and closing with a password process is same as Personal
User. However, each time lock is in open position, each user enters in their own unique
4-digit code to lock and then use that the same code to again open the miniK10. Pop-
ular application is for gym lockers.
Lock is open, rst user enters in <3-4-2-8> and closes lock. They return and enter
the same <3-4-2-8> to open the lock. Lock is open, next user enters in their code of
<7-8-5-2>, closes lock and so on.
Description:
Password types:
Operating modes:
Locker mode (multiple user mode)
NEW USER PASSWORD
1 2
4

By default, the miniK10 is set to Locker Mode. The miniK10 can easily be set to
Personal Mode with either of the two below steps:
1. Before battery tab is removed, hold down key, pull the tab
and key the key pressed 3 seconds
2. Convert lock to Personal Mode at any time by entering in
MasterCode 1 0
Attention:
0
*
#
0
1) Enter your 4-digit user password.On rst use factory default is <1-0-1-0>
2) Rotate handle within 5 seconds to opening direction and there will be a
conrmation beep.
If personal mode is selected, press and old password. Press button again
and enter new 4-digit user password. Press button again and approve new
password.You will get a conrmation beep and green LED light will blink.
Below illustrations show examples of lock installed for right
handed door. Lock can be installed for left or right handed
Personal mode | OPENING WITH USER PASSWORD:
Personal mode | CHANGING USER PASSWORD
USER PASSWORD
1 2
NEW USEROLD USER
5

By default, service password is not active. Activate with Program 5.1. Service password
allows lock to be opened only and none of lock features can be programmed.
If service password function is active, 1) press button and enter current5-digit
service password and press button. 2) Rotate handle within 5 second to opening
direction. You will get a conrmation beep from lock and green LED light will blink.
When you have selected service password in program menu, press button twice
and enter current 5-digit service password. Press button again and enter new
5-digit service password. Press button again and approve new password.You will
get a conrmation beep from lock and green LED lights will blink.
Service password:
opening with service password: Default <1-0-1-0-1>
changing service password:
NOTE:WHAT HAPPENS IF USER FORGETS THEIR PASSWORD?
Locker Mode (Multiple User):
Use Master code to unlock and turn handle to open position. Lock is now ready for
next user to enter in their unique code..
Personal User Mode:
1) Use master code to reset the lock to factory defaults. MasterCode 4 0
2) Default user code is now < 1-0-1-0 > and can be changed.
#
#
SERVICE PASSWORD
OLD SERVICE NEW SERVICE
1 2
6

Opens lock and grants access to all programming features.
1) Press the button and enter current 6-digit master password and press
button. 2) Rotate handle within 5 seconds to opening direction. You will get a conr-
mation beep from lock and green LED light will blink.
Set new master password and test BEFORE installing lock. Press button twice, and
then enter old 6-digit master password. Press button again and enter new 6-digit
master password. Press button again and approve new password. You will get a
conrmation beep from lock.
The miniK10 can be customized from factory default settings tailored to your needs.
Press the button and then enter the 6-digit master password. Press the
button.The Red and Green led’s will blink alternately. Press the program and selection
numbers repeatedly.
Master password:
opening with master password: Default <1-0-1-0-1-0 >
changing master password:
programming the miniK 10
accessing the program menu:
#
#
#
#
#
#
MASTER PASSWORD
MASTER PASSWORD PROG. NO SELECT. NO
OLD PASSWORD NEW MASTER
1 2
NOTE: To the right would change to password being required to close lock
6 0
7

01
Explanation:
0-1 Restores factory default settings:
Prog. No 1-1: Locker mode operation (Multiple user operation)
Prog. No 2-1: Audible beeps and conrmations
Prog. No 3-0: Penalty operation is not active
Prog. No 4-0: Sets user password to factory default
Prog. No 5-0: Service password is not activee
Prog. No 6-1: Closing without password active
Prog. No 7-0: Warning of open lock is not active
Prog. No 8-0: Resetting user password is not active
Prog. No 9-0: Blocking of the lock is not active
10Personal Operation (individual operation)
1Locker Mode Operation (multiple user)
20Mute operation except for warnings
1Audible operation- button feedback, warnings and conrmations
30Penalty passive
1Penalty active (lock blocked for 5 min. if wrong code entered 3 times)
40Sets user default code to factory default (for forgotten combinations)
1-
50Service password is passive
1Service password is active
60Closing with password required is active
1Closing without password is active (for personal usage)
70Warning of lock open is passive
1Warning of lock open is active (beeps 8 times every 5 sec.)
80Resetting user password is passive (if service password is active)
1Resetting user password is active (if service password is active)
90Blocking of the lock is passive (if service password is active)
1Blocking of the lock is active after using service password (if it is active)
PROG. NO
SELECT. NO
8

Programming option denitions:
Lock operates on a 3V lithium coin cell CR2450 battery located on back side of
device. Remove screw located on cover of battery and replace it with new battery.
Battery life is up to 10 years. The red LED light blinks 5 times after each operation
when battery is low and it is possible to open and close lock for 100-150 times
after you get the initial low battery warning.
Changing the battery:
0Restoring factory settings: All factory default settings are restored (see program menu). User
password becomes <1-0-1-0> and master password becomes <1-0-1-0-1-0>.
1
Usage options: Factory default is Personal mode allows one 4-digit code to be entered that
would remain the same code for one user. Locker mode is for multiple users whereby each user
walks up to an open miniK10 and enters in their own unique code to close the lock and then to
open it again. When open, next user enters in a new code, etc.
2Audible volume control: All audio warnings can be turned o if mute operation is selected
(except warning beeps).
3
Penalty operation: Prevents tampering of lock by unauthorized people. Lock is blocked for 5
min if wrong password is entered three times consecutively. Factory default is that this feature
is not active.
4User code reset: Sets user factory default to <1-0-1-0>.
5
Service password: Lock can be opened with service password if user password is forgotten.
Factory service default password is <1-0-1-0-1>. No programming features can be accessed
with service password. Factory default is that this feature is not active.
6Closing modes: Factory default - miniK10 does not require a password to lock. The other
option is it can require a password to lock.
7Lock open warning: After lock is open for one minute, lock gives an audible warning to user
with 8 beeps every 5 sec to notify user that the lock has been left open.
8
Resetting user password: If the lock is opened with service password (and service password
is active), user password can be reset. (see program #5 on service passwords). Factory default
is that the service password access does not allow the user password to be reset (only opens
up the lock).
9
Blocking the lock: If lock opened with service password, it can be blocked from further user
password access.This would. insure service password is only used to access locks for emergen-
cy lockouts. Master password access would then be required to set up user password again
(0-1 Factory default reset). Factory default is that this feature is passive.
9

Maintenance:
General warnings:
Cams:
Clean front of lock with a mild damp cloth with detergent if needed.
Use only Ethanol (Ethyl Alcohol) for disinfecting.
Do not use any hard or scratching cleanser.
Do not clean with chemical materials that melt plastic (thinner, acetone, etc.)
Be careful not to spill water on lock.
Read manual before using lock.
Periodically check nuts and screws to be tightened.
Do not over-tighten nuts or screws. Do not use an electric screw gun during
installation unless equipped with a torque adjuster.The maximum torque on
the cylinder screw is 2Nm.
Set and test user and master password prior to installing the lock
Change all default passwords with your own passwords.
Common sense, but we must say it... Do not keep the passwords in the
cabinet where the lock is being installed!
It is not possible to open lock if installed and you forget the user and master
password.
Lock gives a warning beep when incorrect passwords have been entered
in repeatedly.
Not possible for front side of lock to be opened by breaking or trying to force open lock.
Use CR2450 3.0V Lithium batteries.
Remember that battery consumption is high when programs 2, 3, and 7 are active.
Two cams are included
Cams can be placed at
increments of 90 degrees
The Stop Cam (#4) in installation
instructions can be positioned for
turning the cam clockwise or
counter-clockwise
7/8” Straight
Cam 22mm
1-1/2” Straight
Cam 38mm
10

ATTENTION:
Other:
In case of any failure, inform the vendor in writing of the detailed description of
the failure. In case of any intervention in the device, such as attempting to repair
the device, the device gets OUT OF WARRANTY.
Battery failure override- The miniK10 has 2 external nodes surrounding the
red and green indicator lights where an external battery can be connected
long enough to enter in the correct code to open the lock allowing new
batteries to be installed.
11

Light and audio notication:
ATTENTION: (*) (Battery life may vary in accordance with battery brand, programming
parameters and environmental conditions of the product is used.)
ATTENTION: Remember to write down your passwords after programming and prior
to installing lock.It is not possible to open lock if it is in installed and you forget your
passwords.
ATTENTION: miniK10 is made for only interior usage.
Technical specications:
Password is accepted Green LED blinks with 2 repeated audio warnings.
Wrong password Red LED blinks with 4 repeated audio warnings.
Low batterty Red LED blinks 5 times after each operation.
Lock is open 1 min after door is opened, lock gives audible warning
8 times every 5 sec.
Weight 70,4 g (2.48 oz) (excluding cam and mounting)
Key Pad Silicone Keypad with metal dome
Operating Temperature +10 / +50 °C (50 - 122 °F)
Storage Temperature +0 / +60 °C (32 - 140 °F)
Operating Moisture 20% - 80% Rh (without condensation)
Replaceable Battery 3V Lithium CR2450
Battery Life (*) up to 10 years (for 10 uses a day)
12

quick info
DEFAULT PASSWORDS
OPENING/CLOSING WITH USER PASSWORD
OPENING/CLOSING WITH MASTER PASSWORD
USER PASSWORD
ATTENTION:
These are default settings by the
factory. Once they are changed, be
sure to write down your new code!
ATTENTION:
Opening direction
depends on which to
type of door miniK10
is installed. All opening
illustrations depict
right handed door
installation.
USER PASSWORD
USER PASSWORD
MASTER PASSWORD
MASTER PASSWORD
MASTER PASSWORD
if service password active
setro s.r.o. can make changes about the qualications of the product without informing in advance.
1 10 0
1 10 0
1 10 0
1 1 10 0 0
1 1 10 0 0
1 1 10 0 0
1 1 10 0
1
1
2
1
2
1
2
2
13

CABINETS | LOCKERS | BOXES
Installation
The easy lock
in every aspect

2
14
5
7
8
9
6
3
5
18
1,50
90°
1. miniK10
2. M16x1,5mm Cylinder Nut
3. Stop Cam
4. Cam 22mm Axle
5. Cam 38mm Axle
6. M4x10mm Cam Screw
7-9. Mounting Screws
Locking Position
(Be sure before
mounting).
Rotate Right
(90°) to Open
Note: 5 mm measurement is for 18 mm..!
Half gap should be 1.50 mm
Installation Overview
Do not use longer screw.
It may cause damage!
Hinge
at the
right side
Cover thickness Screw size
0 - 5 mm covers 8 mm
10 - 12 mm covers 16 mm
16 - 18 mm covers 24 mm
15

Mounting on Left & Right Door
Peg on stop cam
is on the right side for
right doors
Hinges on
outside of
door are on
the Right
RIGHT LEFT
Hinges on
outside of
door are on
the Left
Peg on stop cam
is on the left side for
left doors
View of the
lock in
locked
position
Back View
Knob, rotates to the
right to open lock
Back View
Knob, rotates to the
left to open lock
16

Surface Mounting Semi-Flush Mounting
17

12mm
9mm
18mm
27mm24mm 27mm
9mm
18mm
12mm
9mm
18mm
27mm24mm 27mm
9mm
18mm
70,4 g*
*Assembly set is not.
18

Ø 0,63” (16 mm)
Cylinder Hole
Ø 2,44” (62 mm)
miniK10 Outline
Ø 0,16” (4 mm)
Upper Mounting
Screw Hole
Mounting Template
19

Joint erect lock assembly measurements
22 mm axle cam 38 mm axle cam
20
Table of contents
Other setro Lock manuals
Popular Lock manuals by other brands

Simons Voss Technologies
Simons Voss Technologies PegaSys 2.1 quick guide

Andersen
Andersen 400 Series Change guide

SCS Sentinel
SCS Sentinel XO 404 Installation and operation manual

ZKTeco
ZKTeco AL10B user manual

Yale
Yale Assure Lock Lever Touchscreen YRL226 Installation and programming instructions

Borglocks
Borglocks BL2605MG Installation Guide, Parts List & Maintenance Instructions