OKE-6428HC
(adjustable)
Function LCD
Display
Function Range Maker Value
Temp. setting 10.0 -19.9℃ ~ 99.9℃ 10.0℃
oke-6428HC user A manual V19-9 en.PDF
92, 1277bungil, Jungangdae-ro, Dongrae-go,
Busan, South Korea
TEL +82 51 5066428 / FAX +82 51 5076430
E-mail : [email protected]
Homepage : www.swoke.co.kr
User Manual
Aquarium
Temperature Controller
☞Before operating this controller, highly recommended for you
to read this manual carefully without fail.
※ Notandum for safety
‘Please keep the caution for safety rule to use product correctly
and prevent from accidents or potential threat. The notandum
will give 2 options such as “Warning” & “Caution”
Ignoring this symbol could
lead to serious injury or death,
if equipment is handled in
wrong way
!Waring
Ignoring this symbol could lead
to slightly injury or damage to
the product, if equipment is
handled in wrong way
!Caution
1. Must set the fail-safe function system when it will install to
control special equipment which will seriously effect a loss of
lives/properties (atomic energy control, medical device,
vehicle,/train/airplane combustion device, recreation/safety
device, etc.).
2. Must set with attaching at panel. Highly concerns an electric
shock.
3. With power ON, please don’t try to connecting/ repairing/
maintenance. Highly concerns an electric shock
4. Please make sure the terminal number when connect to power.
Highly concerns fire hazard.
5. Only authorized staffs (maker) can reorganize/ reconstruct the
products. Otherwise concerns fire hazard/ electric shock
1. Prohibited to use at outdoor. Otherwise will cause the short
durability of product and concerns a fire hazard.
2. Please use the product within specification ranges. Otherwise will
cause the short durability of product and concerns a fire hazard.
3. Please do not using with over-loaded power at the relay switch
connection. It will cause an error of disconnection/ fire hazard/
relay destroy.
4. Please avoid using the water, organic solvent when it cleaning.
Only use dry towel. It concerns an electric shock & a fire hazard.
5. Please avoid installing at the Inflammable gas/ explosive gas/
direct ray of light/ radiant heat/ vibration/ impact area. It
concerns a fire hazard & explosion.
6. Please keep the product clean & dry without dust/ wire
leftover/etc. it concerns a fire hazard / an operating error
!Waring
!Caution
➢Operation range : -19.9℃~99.9℃
➢External size (mm) : 122(W) x 188(H) x 57(D)
➢Delay time : 0 ~ 9 MIN (1min/unit)
➢Correct Current temperature. : -9.9~+9.9℃ (0.1℃/units)
➢Input sensor : NTC (5KΩ 25℃) sensor
➢Sensor accuracy : Temp 1%
➢Power supply : 230VAC 50/60Hz
➢Power Consumption : Aver. 5VA ↓
➢Ambient temp./ Humidity : 0℃~50℃/ 80% ↓
➢Output : 2 relay ON/OFF (230VAC 10A) (R1:Cooling R2:
Heating)
➢Output deviation : 0.0℃~9.0℃ (0.1℃/units)
Operation Specifications
Products Features
◆Installed Mass storage POWER RELAY (240VAC 10A)
◆Simultaneously operate for Cooler and Heater functions
◆With ONE-TIME setting can control for 4 seasons (365 days)
without any additional operations.
Install Method
1. Connect the Cooler & Heater to plug at Controller correctly.
2. Attach the Temp. detect Sensor at water-tank correctly.
3. Plug-in the controller at power supply outlet.
4. Make sure the temperature LCD Display after power on the
controller.
User function mode - setup process
1. With shortly time press “Set” button, the Temp. LCD Display will
blink.
2. Use Up/Down button, adjust for the required values.
3. New temperature values will be saved automatically after 10
seconds (or press during 5 seconds) and will return to normal
function Display.
Setup process
Current
Temp.
Set
Temp.
설정
Up
Down
Adjust with Up/Down button
LCD
Display
LCD Display
(blink)
LCD Display
(NEW value)
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Setup Process
Function LCD
Display Operation range Maker
Value
Correct Current Temp. -9.9~+9.9℃ (0.1℃/units) 0.0℃
Cooling Output deviation 0.1~+25℃ (0.1℃/units) 1.0℃
Heating Output deviation 0.0℃~9.0℃ (0.1℃/units 1.0℃
Cooling Delay-time 0 ~ 9 MIN (1min/unit) 3 MIN
Heating Delay-time 0 ~ 9 MIN (1min/unit) 3 MIN
Up Down
Up Down Up Down
Up Down
oke-6428HC user A manual V19-9 en.PDF
올림 내림
1.Press “Set” button during 5 seconds and then will display
“- Cor –” at LCD Display as described at right chart. Now
started the master function mode.
2.With shortly press the “Set” button, you can switch the
function mode for what you want to adjust. (refer chart)
3. Use Up/Down button, adjust for the required values.
4. New temperature values will be saved automatically after 10
seconds (or press during 5 seconds) and will return to normal
function Display.
Master function mode –setup process
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
Current
Temp.
Set
Temp.
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
Current /Set Temp.
Display
Press “SET” button
during 5 sec
Convert to master
function mode for
correction current
Temp.
Press SET button
shortly to switch
function mode
Blinking current
value
Use Up/Down
button for new
required value
Convert to master
function mode for
Cooling Output
Deviation
Blinking current
value
Use Up/Down
button for new
required value
Convert to master
function mode for
Heating Output
Deviation
Blinking current
value
Use Up/Down
button for new
required value
Convert to master
function mode for
Cooling Delay-time
Blinking current
value
Use Up/Down
button for new
required value
Convert to master
function mode for
Heating Delay-time
Blinking current
value
Use Up/Down
button for new
required value
Press SET Button
during 5 seconds to
save new values (or
after 10 seconds)
Return to normal function
mode

Popular Aquarium manuals by other brands

Tetra Bubbling LED Kit 1 Gallon Hexagon Quick setup guide

Tetra

Tetra Bubbling LED Kit 1 Gallon Hexagon Quick setup guide

AquaLighter Aquascape quick start guide

AquaLighter

AquaLighter Aquascape quick start guide

EHEIM 600 T operating instructions

EHEIM

EHEIM 600 T operating instructions

Red Sea REEFER XL300 Assembly manual

Red Sea

Red Sea REEFER XL300 Assembly manual

AutoAqua Smart Stir SS-100 manual

AutoAqua

AutoAqua Smart Stir SS-100 manual

eKoral eKoral Pro user manual

eKoral

eKoral eKoral Pro user manual

fish mate F14 instructions

fish mate

fish mate F14 instructions

Amtra VEGA manual

Amtra

Amtra VEGA manual

JBL PRO SILENT S-100 Instructions for use

JBL

JBL PRO SILENT S-100 Instructions for use

Innovative Marine MightyJet 8500 Mini How to use

Innovative Marine

Innovative Marine MightyJet 8500 Mini How to use

SuperFish Planty 25 Warranty and manual

SuperFish

SuperFish Planty 25 Warranty and manual

Royal Exclusiv Bubble King DeLuxe 300 datasheet

Royal Exclusiv

Royal Exclusiv Bubble King DeLuxe 300 datasheet

Sera Marin Precision Biotop LED Cube 130 Instructions for installation and use

Sera

Sera Marin Precision Biotop LED Cube 130 Instructions for installation and use

Commodity Axis ViaAqua Titanium Heater manual

Commodity Axis

Commodity Axis ViaAqua Titanium Heater manual

JBL CRISTALPROFI i60 greenline manual

JBL

JBL CRISTALPROFI i60 greenline manual

GNC BluRayPro manual

GNC

GNC BluRayPro manual

JBL Blanki Set quick start guide

JBL

JBL Blanki Set quick start guide

Red Sea REEFER XL300 Assembly manual

Red Sea

Red Sea REEFER XL300 Assembly manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.