USER & SAFETY GUIDE
Read before use
This document contains important technical and safety information
about the device and its safety use and installation.
⚠CAUTION! Before beginning the installation, please read this guide and
any other documents accompanying the device carefully and complete-
ly. Failure to follow the installation procedures could lead to malfunction,
danger to your health and life, violation of the law or refusal of legal and/or
commercial guarantee (if any). Allterco Robotics EOOD is not responsible
for any loss or damage in case of incorrect installation or improper opera-
tion of this device due to failure to follow the user and safety instructions
in this guide.
Introduction to Shelly devices
Shelly® is a line of innovative microprocessor-managed devices, which
allow remote control of electric appliances through a mobile phone,
tablet, PC or home automation system. Shelly® devices can work stand-
alone in a local Wi-Fi network or they can also be operated through cloud
home automation services. Shelly® devices can be accessed, controlled
and monitored remotely from any place the user has internet connectiv-
ity, as long as the devices are connected to a Wi-Fi router and the Inter-
net. Shelly® devices have built-in web servers through which the user
can adjust, control and monitor them. The cloud function can be used if
it is activated through the web server of the device or the settings in the
Shelly Cloud mobile application. The user can register and access Shelly
Cloud using either Android or iOS mobile application, or with any internet
browser at https://my.shelly.cloud.
Shelly® devices have two Wi-Fi modes - Access Point (AP) and Client
mode (CM). To operate in Client Mode, a Wi-Fi router must be located
within the range of the device. Shelly® devices can communicate directly
with other Wi-Fi devices through HTTP protocol. An API is provided by
Allterco Robotics EOOD. For more information, please visit
https://shelly-api-docs.shelly.cloud/#shelly-family-overview or contact
us at developers@shelly.cloud.
Control your home with your voice
Shelly® devices are compatible with Amazon Alexa and Google Home
supported functionalities. Please see our step-by-step guide on
https://shelly.cloud/support/compatibility.
Shelly® TRV (the Device) is an intelligent Wi-Fi connected, self-regulating
valve tted to a hot water heating system radiator. It can control the tem-
perature of a room by changing the ow of the hot water through the radi-
ator. Shelly® TRV can maintain the room temperature according to a set
weekly schedule. If needed, the temperature can be changed at any time
by pressing the buttons on the device, or through your mobile phone, tab-
let or PC. Shelly® TRV is powered by a built-in rechargeable battery. The
battery can be recharged via a USB-C connector. Shelly® TRV is designed
to work without recharging for 2 years, but this depends on the specic
working conditions, such as how often it is necessary to adjust the hot
water ow, Wi-Fi signal strength and wireless network quality.
7
45 6
1
2
3
1. Display
2. Up button
3. Down button
4. Temperature sensor
5. USB type C charging port
6. Reset button
7. Metal ring
Installation Instructions
⚠CAUTION! The product is intended for indoor use only.
⚠CAUTION! Protect the product from dirt and moisture.
⚠CAUTION! Do not use the product in a damp environment and avoid
splashing water.
⚠CAUTION! Ensure that the radiator is turned off and has cooled down
before beginning the Device installation.
Compatible valves
If you already have thermostatic radiator valves, which typically have a
dial on top with numbers from 1 to 5, most probably, your radiators are
compatible with Shelly® TRV. Check the list of compatible radiator valves
by brand and model at https://shelly.cloud/knowledge-base/devices/
shelly-trv/.
Radiators with manual valves are not compatible with Shelly® TRV. Man-
ual valves are typically small and discrete. They are standard when you
have a separate thermostat in the room or a central thermostat.
If your radiator valves are not compatible you can use one of the adapters
included in the box.
Remove the existing thermostatic radiator valve
1
2
1. Turn the dial counter clockwise until the valve is fully open.
2. Unscrew the metal ring counter clockwise to remove the valve.
Install Shelly® TRV
1. Check if you need an adapter and, if necessary, mount the suitable one
before installing Shelly® TRV.
2. Fasten the Shelly® TRV to the radiator valve by turning the metal ring
clockwise. Do not fully tighten the ring.
3. Place the Device display in the correct position and then fully tighten
the metal ring.
⚠CAUTION! Do not try to rotate the Device, if the metal ring is fully tight-
ened. This can damage it.
Switch on the Device
Press briey the Device Reset button. The screen will light up with the
CL message and the motor inside will turn in both directions. This is the
calibration process.
If the calibration process is successful, the screen will display AP and the
Device is ready to be connected to your Wi-Fi network.
If the calibration is not successful, E1 message will be displayed. The
reason is either the ring is not tightened enough or the Device is not prop-
erly mounted to the radiator.
Try tightening the ring or remove the Device and carefully mount it again.
Press and holding for 3 seconds any of the Up and Down buttons. Then
press Down button a couple of times. The Device will try to calibrate again.
⚠IMPORTANT: If the Device has not been added into your Wi-Fi network
in 3 minutes, it will switch off. Press briey the Reset button to start it
again.
If needed, the Device can be switched off manually by pressing briey the
Reset button while the Device is in AP mode.
Charge the device
Fully charge the Device before its rst use for about 7 hours. Battery sta-
tus is displayed while charging. The line, which indicates the battery level,
is ashing while the device is charging. A dot is displayed next to the bot-
tom line, when a charger is connected. If the battery level is not displayed,
press briey the Reset button.
• b
_
.<50%
• b=. 50-75%
• bX. >90%
⚠IMPORTANT: The device heats up during charging, which prevents it
from measuring the room temperature correctly.
⚠CAUTION! Use only charging adapters that comply with USB-C standard. Do
not use the Device if the charging adapter or the charging cable are damaged.
⚠CAUTION! Do not use the Device if it has been damaged.
⚠CAUTION! Do not attempt to service or repair the Device yourself.
Device Status
To check the Device status press and hold for 5 seconds both Up and
Down buttons. Use the Up or Down buttons to scroll through all the pa-
rameters:
• Mode:
 -AP Access point mode
 -St Station mode
 -CO connected to a Wi-Fi network
• Battery level:
 -b
_
<50% (<10% if the dash is ashing)
 -b= 50-75%
 -bX >90%
• Status:
 -E0 No issues
 -E1 Calibration problem
 -E2 Temperature sensor problem
Initial inclusion
The most convenient way to use your Shelly® devices is through the
Shelly Cloud mobile application and Shelly Cloud service.
Download the Shelly Cloud mobile application for Android or iOS here:
Instructions on how to connect your device to the Shelly Cloud and con-
trol it through the Shelly mobile application can be found in the enclosed
App Guide.
Manually connecting to a Wi-Fi network
You can manage and control the Device through its embedded web in-
terface too.
• Make sure Shelly® TRV is in AP mode. Open the Device WebUI at
192.168.33.1 in the created by the Device Wi-Fi network.
• Click the Internet & Security button and then select
WIFI MODE - CLIENT.
• Check the Connect the Shelly device to an existing WiFi Network
checkbox, enter the Wi-Fi network name and password, and press the
SAVE button.
• Find your Device IP address in the Wi-Fi network. You can use a sim-
ple tool to nd shelly devices in the local network: https://shelly.cloud/
documents/device_nders/ShellyFinderWindows.zip (Windows) and
https://shelly.cloud/documents/device_nders/ShellyFinderOSX.zip
(Mac OSX).
⚠IMPORTANT: Enabling the Client mode will disable the Access Point
mode. In case you need the Access Point mode again, press the Reset
button for 5 seconds.
How to control room temperature
Setting room temperature using the buttons
• Press shortly any of the buttons to see the measured by the Device
room temperature. The display will show the measured room tempera-
ture for 3 seconds.
• Press and hold one of the buttons for 3 seconds to display the current
temperature with a dot at the last digit. Press the Up or the Down button
to set new target temperature in the range of 5°C to 30°C.
LO message on the display means that the valve is fully closed, and HI
means that the valve is fully open.
Setting room temperature using the Shelly Cloud APP
The room temperature can also be monitored and controlled through the
Shelly Cloud APP. Check the App Guide for more information.
Setting room temperature using the Device WebUI
• Access the Device by its IP address in your Wi-Fi network.
• Use the red and the blue arrows to set new target temperature.
• When the Device receives the new target temperature, a dot will ash
briey on the display.
⚠IMPORTANT: If a weekly schedule is activated, the manually set target
temperature will be overridden by the next scheduled one.
Scheduling
Shelly® TRV supports up to 5 pre-set proles to control the temperature
in the room on a weekly schedule. Up to 20 temperature changes can be
added to each prole.
Setting Schedule using the Shelly Cloud APP
The scheduling can also be activated and set through the Shelly Cloud
APP. Check the App Guide for more information.
Setting Schedule using the Device WebUI
• Access the Device by its IP address in your Wi-Fi network.
• Click on Weekly schedule button.
• Select a prole from the dropdown. Select the Disable prole to disable
the scheduling.
• Click on EDIT CURRENT SCHEDULE to add, remove or edit temperature
changes.
• Change the prole name if desired by typing a new name and pressing
the RENAME button.
• Click on the SET A NEW TIME button to add a temperature change time.
• Select a desired temperature, check the weekdays it applies to and click
the SAVE button.
• Edit a scheduled temperature change by clicking the yellow pencil but-
ton, or delete it by clicking the red bin button.
Using external temperature sensor
Every radiator-mounted thermostat has a slight deviation from the actu-
al room temperature, since the temperature measurement is performed
too closely to the radiator. Shelly® TRV solves the problem by supporting
communication with an external temperature sensor (i.e Shelly H&T) or a
compatible one, located anywhere in the room.
Enabling external sensor using the Shelly Cloud APP
The use an external temperature sensor can also be enabled through the
Shelly Cloud APP. Check the App Guide for more information.
Enabling external sensor using the Device WebUI
• Access the Device by its IP address in your Wi-Fi network.
• Click on Sensor Settings button.
• Click TEMPERATURE OFFSET
• Check the Enable external temperature corrections endpoint check-
box.
• Set a manual temperature offset, if desired, and press the OK button.
⚠CAUTION! Do not allow children to play with the Device. Keep the de-
vices (mobile phones, tablets, PCs) that can remotely control the Device
away from children.
Specication
Specications are subject to change without notice.
• Model: Shelly TRV-01
• Dimensions (HxWxL): 62x53x94 mm
• Mounting: M30/15
• Power supply: 3.6V 6500mAh NCR18650BD Panasonic rechargeable
battery
• Battery life: up to 2 years (depends on working conditions)
• Charger requirements: USB type C (≥1A)
• Electrical consumption: < 500 μA
• Working temperature: -10°C to 40°C
• Temperature control range: 5°C to 30°C
• Radio signal power: 1mW
• Radio protocol: Wi-Fi 802.11 b/g/n
• Frequency: 2412 - 2472 МHz (Max. 2495 MHz)
• RF Output power: <20 dBm
• Operational range: up to 30 m (depends on building construction and
materials)
• MQTT: YES
• CoAP: YES
• REST API: YES
• URL Actions: YES
• Scheduling: 5 proles
• CPU: SiLabs
• Flash: 6MB
Declaration of conformity
Hereby, Allterco Robotics EOOD declares that the radio equipment type
Shelly TRV is in compliance with Directive 2014/53/EU, 2014/35/EU,
2014/30/EU, 2011/65/EU. The full text of the EU declaration of confor-
mity is available at
https://shelly.cloud/knowledge-base/devices/shelly-trv/
Manufacturer: Allterco Robotics EOOD
Address: Bulgaria, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Web: http://www.shelly.cloud
Changes in the contact data are published by the Manufacturer at the
ocial website of the Device: https://www.shelly.cloud.
All rights to trademark Shelly®, and other intellectual rights associated
with this Device belong to Allterco Robotics EOOD.
PAP
20

Other manuals for TRV

1

Popular Thermostat manuals by other brands

Honeywell INNCOM E529 Wiring guide

Honeywell

Honeywell INNCOM E529 Wiring guide

oventrop Uni LHB Installation and operating instructions

oventrop

oventrop Uni LHB Installation and operating instructions

AAON Mini Controller user manual

AAON

AAON Mini Controller user manual

Grant UFLEX EDGE manual

Grant

Grant UFLEX EDGE manual

Watts Industries MILUX RF user guide

Watts Industries

Watts Industries MILUX RF user guide

Warmup OTN-1991-WA instructions

Warmup

Warmup OTN-1991-WA instructions

Tekmar tekmarNet 4 546 User brochure

Tekmar

Tekmar tekmarNet 4 546 User brochure

Honeywell Home TL8130A1005 owner's manual

Honeywell Home

Honeywell Home TL8130A1005 owner's manual

Payne TSTAT installation manual

Payne

Payne TSTAT installation manual

Carrier XCT 7 40VCC727FQEE Operation & installation manual

Carrier

Carrier XCT 7 40VCC727FQEE Operation & installation manual

Netatmo S+ARCK Quick installation guide

Netatmo

Netatmo S+ARCK Quick installation guide

Aube Technologies TH102D Installation

Aube Technologies

Aube Technologies TH102D Installation

Efapel 21232 quick start guide

Efapel

Efapel 21232 quick start guide

Honeywell RCT8101 Quick installation guide

Honeywell

Honeywell RCT8101 Quick installation guide

DELTA DORE Tybox 5701FP quick start guide

DELTA DORE

DELTA DORE Tybox 5701FP quick start guide

Honeywell TRADELINE T8011R Product data

Honeywell

Honeywell TRADELINE T8011R Product data

XCI TSH-2 TrueTouch instruction manual

XCI

XCI TSH-2 TrueTouch instruction manual

Cordivari CLAUDIA EL. user manual

Cordivari

Cordivari CLAUDIA EL. user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.