Description and functions of the Fixed Panic Panel
The Ver 4 Fixed Panic Panel is designed to activate its Relay output when either a remote or
hard-wired panic button is pressed. The unit will switch the PANIC output relay for 3
seconds. The unit will Latch the Strobe output. The Siren output will stay on for 3
Minutes. The unit can be reset thus switching the Strobe Light and Siren Outputs off by
either the Reset input or by Pressing the remote transmitter again.
The battery voltage is monitored and in a power-failure the battery will be isolated from the
circuit if the voltage measures below 10V. When the AC input is restored the unit will switch
back on and start to charge the battery.
Specifications
Encryption.............................................. Code Hopping encryption
Frequency................................................403.55Mhz
Range open air line of site...................... 200m
Range indoors..........................................60m
Voltage range..........................................110 - 240 Volt AC / 50Hz
Internal Power supply..............................14.2V DC 3 Amp
Current drain............................................20mA, @ 12.6VDC
Relay Output............................................2 second momentary (Radio / Aux)
..............................................3 Minute (Siren)
..............................................Latching till reset (Strobe)
Dimensions...............................................270 X 240 X 70mm
Weight of packaged product......................0.80Kg
Package Contents:
One Fixed Panic Panel unit
Two Single Button Remote panic buttons. Model: PTX1
One Installation guide
Deleting all codes / Defaulting.
Defaulting
Erasing Individual remotes
LEARN
LEARN
ERASE
Press and hold for longer than 10 Seconds.
When the unit sounds a Long Beep you can
stop pressing the button and then
wait for it to silence.
Press the button
to be erased
Repeat for each remote
to be erased.
You must erase
one remote
at a time.
This function will Default ( Erase all) remotes from the units memory
Link On
20 beeps
For more info visit our web site: www.sherlotronics.com Technical help :- 011-462-5101
Long beep
Programming Please follow the steps below to Learn in remotes to the receiver.
The unit can store up to 80 remotes. When memory has reached
its limit the unit will automatically exit out of program mode and
sound a long beep. The unit auto exits after 10 seconds.
LEARN
Step 1. Step 2.
Step 3.
Press button twice
Exits from Learn
Step 4.
LEARN
Continue with Step 2 to
Learn in all the remotes
A Max of 80 remotes can
be learnt to memory
Enters Learn mode
1 beep 2 beeps
Long beep
Installation Guide
For more info visit our web site: www.sherlotronics.com Technical help :- 011-462-5101
Model: PTX1