manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Shinko
  6. •
  7. Scale
  8. •
  9. Shinko GS600 User manual

Shinko GS600 User manual

This manual suits for next models

5

Other Shinko Scale manuals

Shinko CUX II Series User manual

Shinko

Shinko CUX II Series User manual

Shinko HG-1000 C User manual

Shinko

Shinko HG-1000 C User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

V EXTERNAL CALIBRATION
IMPORTANT: The scale was professionally calibrated before
shipment. It does not recalibrated before use and will not usually
require calibration during its lifetime. However some advanced
users who seek optimum accuracy may wish to calibrate the scale
periodically to maintain perfect accuracy. Incorrect calibration can
occur if you do not follow the steps exactly
1Press to turn on the scale for warm-up 1-2 seconds
2Press to show “0.0” , then press for 3s, it will
show “CAL 0” and “LOAD –XXX g”
3Place a weight which value equal to the number on the tray
(the showed number is 1000g ,that means you should place a
1000g weight on the tray),,it will display the weight value if
success, then return to the normal weighing.
NOTE: If your scale still does not read accurately, it means that
the calibration is failed and please follow the above steps to
re-calibration slowly.
Please do it on a very stable and flat surface!
VI BASIC SPECIFICATION
Tray Square size: 155x155mm / Round size : Φ125mm
Display Mode Large LCD display , backlight (optional)
Power supply 4 batteries , or DC adaptor (6V/300mA)(Optional)
Operation Temp. 0-40℃
ELECTRONIC BALANCE
SHINKO GS SERI
Operation Manual
VIBRA SCALES JSC
III EXPLANATION OF SYMBOLS
: negativevalue O: stable /zero indicator
: unitsindicator g : unit
: lowbatteryindicator PCS : count indicator
IV OPERATIONS
1Turn on the scale
Press to turn on the scale. The scale will show
“88888”and other indicators ,and then it will be ready for use.
2Start weighing
A. Weighing without container
If the reading is not “0” or the zero indicator isn’t displayed,
press to display “0” and the zero indicator appears, then the
place objects on the tray, when the stable indicator appears, the
value displayed is the weight of the objects.
B Weighing with container
Place an empty container on the tray ,press to display “0”
after the stable indicator appears, then place the objects into
container ,after stable, the value displayed is the weight of the
objects.
3Counting
Turn on the scale and put on the integral sample, Press to
show S-10 ,press again to select a parameter of
S-10/20/50,after a few seconds it begin to counting mode. Press
to exit.
4Power-off andAutomatic power-off
A Press directly to turn off the scale
B If your scale have auto-power off function before shipment,
it will auto turn off after non-operation for 3 seconds.
I NOTICE
Precautions Before Using the scale
The scale should be used in a stable environment without
ventilation and corrosion , extreme in temperature and humidity.
These factors can affect the accuracy and performance of the scale.
Operation Advices
■ The better environment, the more in favor of normal
weighing
■ Allow sufficient warm up time. 1-2 minutes is necessary
■ Do not mismatch battery and please install all batteries at the
same time.
■ Take out all batteries when non-operation long, it can avoid
the damage of scale.
■ Do not overload the scale, overloading the scale will damage
the sensor and void your warranty.
■ Handle with care. Although this scale is designed to be quite
durable and firm, rough treatment may damages the internal
sensor permanently.
■ Remove the object immediately after finishing weighing. It
can prolong the life-pan and accuracy of the scale.
II KEYPAD FUNCTIONS
1 PowerSwitch
2 Select the unit, units optional refer to panel
3 Count
4 Reset the scale to zero or tare
Model number Capacity Division Pan Size (mm)
SHINKO GS600 600g 0.1g 155 x 155
SHINKO GS1 1kg 0.1g 155 x 155
SHINKO GS2 2kg 0.1g 155 x 155
SHINKO GS3 3kg 0.5g 155 x 155
SHINKO GS3001 3kg 0.1g 155 x 155
SHINKO GS6 6g 1g 155 x 155
THINH PHAT SCALES JSC
VIBRA SCALES JSC
VIET NAM SCALES JZC