Overview:
Trove2SL2 accommodates various combinations of Sielox boards with or without Altronix power supplies and accessories for access systems.
Specifications:
• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.
Trove2SL2
Trove2 enclosure with TSL2 Altronix/Sielox backplane.
• Includes: tamper switch, cam lock, and mounting hardware.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm).
TSL2
Altronix/Sielox backplane only
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).
TSL2 accommodates a combination of the following:
Altronix Modules:
• Up to two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.
• One (1) ACM8(CB), ACMS8/ACMS8CB, PDS8(CB), VR6, MOM5, PD4UL(CB), PD8UL(CB), or ACM4(CB).
Sielox Boards:
• Up to eight (8) AC-1700.
Agency Listings:
• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity.
Installation Instructions for Trove2:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Trove2SL2 (Pg. 4): Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper
fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws;
level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three
fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three
lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of
the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Sielox modules to TSL2 backplane, refer to page 3.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure

Trove2SL2 / TSL2 Installation Guide - 3 -
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
RJ45 Jack
RJ45 Jack
RJ45 Jack
RJ45 Jack
Altronix
Power Supply
or
Sub-Assembly
Altronix
Power Supply
or
Sub-Assembly
Altronix
Sub-Assembly
Metal Spacer Placement
Metal Spacer Placement
Altronix
Sub-Assembly
TSL2: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and Sielox AC-1700 Modules
1. Fasten spacers (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards
(Fig. 2, pg. 2). Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 2, pg. 2).
Note: Each Altronix sub-assembly position can accommodate one (1) ACM8/ACM8CB, ACMS8/ACMS8CB, PD4UL/PD4ULCB,
PD8UL/PD8ULCB, MOM5, PDS8(CB) or VR6.
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 2, 2a, pg. 2).
3. Mount Sielox AC-1700 modules into the correct positions (Fig. 2, pg. 2).
Note: Sielox AC-1700 boards have one (1) RJ45 jack each.
Please make sure that they are mounted correctly, as shown in Fig. 2 below
4. Fasten TSL2 backplane to Trove2 enclosure utilizing pan head screws (provided).
Fig. 2
Pem
Spacer
Power Supply,
Sub-Assembly
or Sielox AC-1700
BackplanePan Head
Screw
Fig. 2a

- 4 - Trove2SL2 / TSL2 Installation Guide
TSL2: Configuration of Sielox AC-1700 Modules
1. Fasten spacers (provided) to pems that match the hole pattern for Sielox AC-1700 modules, see below (Fig. 3, pg. 4).
3. Mount Sielox AC-1700 modules into the correct positions (Fig. 3, pg. 4).
Note: Sielox AC-1700 boards have one (1) RJ45 jack each.
Please make sure that they are mounted correctly, as shown in Fig. 3 below
4. Fasten TSL2 backplane to Trove2 enclosure utilizing pan head screws (provided).
Fig. 3
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
RJ45 Jack
RJ45 Jack
RJ45 Jack
RJ45 Jack
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
Sielox
AC-1700
RJ45 Jack
RJ45 Jack
RJ45 Jack
RJ45 Jack
Pem
Spacer
Power Supply,
Sub-Assembly
or Sielox AC-1700
BackplanePan Head
Screw
Fig. 3a

Trove2SL2 / TSL2 Installation Guide - 5 -
Notes:

- 6 - Trove2SL2 / TSL2 Installation Guide
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help
keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up,
minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total
Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Accesscontrolandusermanagment:Restrictread/write,Restrictuserstospecicresources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- EmailandWindowsDashboardnotications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Module
Altronix eFlow
Power Supply
Network Connection:
Installation, Programming
and Monitoring

Trove2SL2 / TSL2 Installation Guide - 7 -
2.2” (55.9mm) 2.2” (55.9mm)
19.375” (492.1mm)
12.625” (320.7mm)
8.5” (215.9mm)
16.25” (412.8mm)
1.0” (25.4mm)
1.0” (25.4mm)
9.2” (233.7mm) 9.2” (233.7mm)
7.5” (190.5mm) 7.5” (190.5mm)
25.375” (644.6mm)
0.45” (11.4mm)0.45” (11.4mm)
0.156”
( 3.96mm)
TSL2 Dimensions (H x W x D):
25.375” x 19.375” x 0.5” (644.6mm x 492.1mm x 12.7mm)

- 8 - Trove2SL2 / TSL2 Installation Guide
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)
Trove2SL2 Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm)
Sielox LLC is not responsible for any typographical errors.
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
170 East Ninth Avenue Runnemede, New Jersey 08078 | phone: 856-939-9300
IITrove2SL2 / TSL2 J06U
This manual suits for next models
1
Table of contents
Popular Enclosure manuals by other brands

Peavey
Peavey PVs 15 Sub operating manual

RS PRO
RS PRO SB565 instructions

DataComm Electronics
DataComm Electronics 45-8017-1 Instruction/installation sheet

Vertiv
Vertiv XTE 801 Series Description and installation manual

Advantech
Advantech MIC-3056 user manual

American Dryer
American Dryer ADA-RK installation instructions

ADC
ADC HiGain HRE-206 List 1 Technical practice

ETC
ETC OneTrack Backbone End Feed Housing installation guide

Thermaltake
Thermaltake H330 TG user manual

OWC
OWC Mercury Elite-AL Pro Assembly manual

MTX
MTX ThunderForm HONDA CIVIC user manual

Keysight Technologies
Keysight Technologies PD1500A System installation guide