Specifications/Product Ordering
Thermostats
www.usa.siemens.com/hvaccomponents
A-42
Operating Voltage.........................................................................120 Vac
Frequency ................................................................................... 50/60 Hz
Power Consumption..........................................................Maximum 4 VA
Control Outputs (Fan) 11, 10, 9 ... 120 Vac max./3A res./3.5 FLA/7.0 LRA
Control Output 3..................................................................... 0 to 10 Vdc
Resolution .................................................................................... 39 mV
Current ......................................................................................... ±1 mA
Signal Input 2 for Changeover Sensor ......................QAH11.1, Class 2,
NTC resistor 3K Ωat 77°F (25°C)
Permissible Number of Thermostats........Ten in Parallel, Signal Input 3
Status Input D1 and GND
Contact Sensing................................................... 6 to 15 Vdc/3 to 6 mA
Insulation against live voltage ......................................................... 4 kV
Operating Action ......................................................Normally Open (NO)
Permissible Cable Length with Copper
Cable 16 AWG for Connection to Signal Input 2,
D1, and GND....................................................................... 262 feet (80m)
Setpoint Setting Range....................................... 50 to 85°F (10 to 30°C)
Setpoint (Energy Saving Mode), Heating ............................ 61°F (16°C)
Setpoint (Energy Saving Mode), Cooling............................ 82°F (28°C)
Operation
Temperature ...................................................... 32 to 122°F (0 to 50°C)
Humidity .................................................................................. <95% RH
Shipping and Storage
Temperature ............................................ –13 to +158°F (–25 to +70°C)
Humidity .................................................................................. <95% RH
Agency Approvals ......................................................................... UL 873
cUL
Certification C22.2 No. 24-93
Conforms to CE Requirements
Connection Terminals .............. Solid Wires or Prepared Standard Wires
2 X16 AWG or 1 X14 AWG
Minimum 20 AWG
Housing Color
Cover.............................................................................. White and gray
Base ...............................................................................................Gray
Degree of Housing Protection.................................................... NEMA 1
Shipping Weight .............................................................. 0.5 lb. (0.23 kg)
Description Part No.
Two-pipe fan coil unit controller,
on/off output RCC10U
Two-pipe fan coil unit controller with
additional electric heat; on/off output RCC20U
RCC...
RCC10U/20U Controller
Dimensions are shown in inches (mm).
Baseplate
TH0613R1
3.54
(90)
0.16 (4)
0.16 (4)
1.10
(28)
1.10
(28)
1.10
(28)
1.10
(28)
1.02
(26)
1.18
(30)
1.38
(35)
1.18
(30)
0.46
(11.8)
4.09
(104)
0.16
(4)
A-77
Accessories
& Service Kits
Dimensions