Siemens RDG100KN User manual

Other manuals for RDG100KN

6

This manual suits for next models

1

Other Siemens Thermostat manuals

Siemens RCR114.1 User manual

Siemens

Siemens RCR114.1 User manual

Siemens TH 180 User manual

Siemens

Siemens TH 180 User manual

Siemens TH 192 HC Owner's manual

Siemens

Siemens TH 192 HC Owner's manual

Siemens RDF310.2/MM User manual

Siemens

Siemens RDF310.2/MM User manual

Siemens RAK-TR IP43 User manual

Siemens

Siemens RAK-TR IP43 User manual

Siemens RDF600T User manual

Siemens

Siemens RDF600T User manual

Siemens RCR10/868 User manual

Siemens

Siemens RCR10/868 User manual

Siemens QAX34.1 User manual

Siemens

Siemens QAX34.1 User manual

Siemens RDG100KN User manual

Siemens

Siemens RDG100KN User manual

Siemens RDG400KN User manual

Siemens

Siemens RDG400KN User manual

Siemens REV100 User manual

Siemens

Siemens REV100 User manual

Siemens RDF300 Series Operator's manual

Siemens

Siemens RDF300 Series Operator's manual

Siemens RDD100.1DHW User manual

Siemens

Siemens RDD100.1DHW User manual

Siemens Powers TH 192 S Owner's manual

Siemens

Siemens Powers TH 192 S Owner's manual

Siemens RDG100KN Operator's manual

Siemens

Siemens RDG100KN Operator's manual

Siemens QFA1 Series User manual

Siemens

Siemens QFA1 Series User manual

Siemens Connected Home RDZ100ZB User manual

Siemens

Siemens Connected Home RDZ100ZB User manual

Siemens RDS110 User manual

Siemens

Siemens RDS110 User manual

Siemens REV23RF User manual

Siemens

Siemens REV23RF User manual

Siemens RDS120 User manual

Siemens

Siemens RDS120 User manual

Siemens RDG110 User manual

Siemens

Siemens RDG110 User manual

Siemens RDG405KN User manual

Siemens

Siemens RDG405KN User manual

Siemens REV17 Series User manual

Siemens

Siemens REV17 Series User manual

Siemens RDG160T User manual

Siemens

Siemens RDG160T User manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

s
3191
Room thermostats with
KNX communications
RDG100KN
RDG160KN
–
For fan coil unit applications
–
For universal applications
–
For use with compressor in DX type equipment
•KNX bus communication (S-mode and LTE mode)
•Backlit display
•2P / PI / P control
•Outputs for On/Off, PWM, 3-position or DC 0...10 V control
•Outputs for 3-speed, 1-speed, or DC (DC 0...10 V) fan
•3 multifunctional inputs for keycard contact, external sensor, etc.
•Operating modes: Comfort, Economy and Protection
•Automatic or manual fan speed control
•Automatic or manual heating / cooling changeover
•Minimum and maximum limitation of room temperature setpoint
•Control depending on the room or the return air temperature
•Selectable relay output functions (RDG160KN)
•Adjustable commissioning and control parameters
•Commissioning with Synco ACS, ETS or via local HMI
•Integration into Synco
•Integration into Desigo via group addressing (ETS) or via individual
addressing
•Integration into third-party system via group addressing (ETS)
•Operating voltage:
RDG100KN: AC 230 V
RDG160KN: AC 24 V
Edition 3.2
CE1N3191en
2014-05-23
Building Technologies
Use
The RDG1...KN room thermostats are designed for use with the following types of
system:
Fan coil units via On/Off or modulating / DC control outputs:
•2-pipe system
•2-pipe system with electric heater
•2-pipe system and radiator / floor heating
•4-pipe system
•4-pipe system with electric heater (RDG100KN)
•2-stage heating or cooling system
Chilled / heated ceilings (or radiators) via On/Off or modulating / DC control
outputs:
•Chilled / heated ceiling
•Chilled / heated ceiling with electric heater
•Chilled / heated ceiling and radiator / floor heating
•Chilled / heated ceiling, 2-stage cooling or heating
Compressor application via On/Off control (RDG160KN)
•Compressors in DX-type equipment
•Compressors in DX-type equipment with electric heater
•Compressors in DX-type equipment with Radiator
•2-stage compressors in DX-type equipment for heating or cooling
The RDG100KN controls...
•One single or 3-speed fan
•One or two On/Off / PWM / 3-position valve actuators
•One valve actuator and one electric heater / Radiator
The RDG160KN controls...
•One single, 3-speed or DC 0...10 V fan
•One or two On/Off valve actuators / el. Heater / radiator with DC fan
•One or two DC valve actuators / el. Heater / radiator with DC fan
•One or two DC valve actuators / el. Heater / radiator with 1 / 3-speed fan
•One On/Off valve actuator, one DC valve actuator with DC fan
•1 or 2-stage compressor in DX-type equipment, with electric heater / radiator
Used in systems with:
•Heating or cooling mode
•Automatic heating/cooling changeover
•Manual heating/cooling changeover
•Heating and cooling mode (e.g. 4-pipe system)
The room thermostats are delivered with a fixed set of applications.
The relevant application is selected and activated during commissioning using one
of the following tools:
•Synco ACS
•ETS
•Local DIP switch and HMI
2 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Functions
•Room temperature control via built-in temperature sensor or external room
temperature / return air temperature sensor
•Changeover between heating and cooling mode (automatic via local sensor or
bus, or manual)
•Selection of applications via DIP switches or commissioning tool (ACS, ETS)
•Select operating mode via operating mode button on the thermostat
•Parameters download with commissioning tool (ACS, ETS)
•Temporary Comfort mode extension
•Single speed, 3-speed or DC 0...10 V fan control (automatic or manual)
•Display of current room temperature or setpoint in °C and/or °F
•Minimum and maximum limitation of room temperature setpoint
•Button lock (automatic or manual)
•3 multifunctional inputs, freely selectable for:
−Operating mode switchover contact (keycard, window contact, etc.)
−Sensor for automatic heating / cooling changeover
−External room temperature or return air temperature sensor
−Dewpoint sensor
−Electric heater enable
−Fault input
−Monitor input for temperature sensor or switch status
−Supply air temperature sensor (RDG160KN)
•Advanced fan control function, e.g. fan kick, fan start delay, selectable fan
operation (enable, disable or depending on heating or cooling mode)
•Purge function together with 2-port valve in a 2-pipe changeover system
•Reminder to clean fan filters
•Floor heating temperature limitation
•Minimum and maximum supply air temperature limitation (RDG160KN)
•Reload factory settings for commissioning and control parameters
•KNX bus (terminals CE+ and CE-) for communication with Synco or KNX
compatible devices
•Display of outside temperature or time of day via KNX bus
•Time scheduling and central control of setpoints via KNX bus
•With a Synco RMB7xx controller, the energy demand signal of the thermostat is
used to optimize energy supply
•Selectable relay function for switching external equipment (RDG160KN)
3 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Applications
The thermostats support the following applications, which can be configured using
the DIP switches at the rear of the unit or a commissioning tool.
DIP switches 1...3 need to be set to OFF (remote configuration, factory setting) to
select an application via commissioning tool.
Remote configuration, via commissioning tool (factory set)
•Synco ACS
•ETS
DIP switches
ON
Applications for fan coil systems
Applications, DIP setting, Control outputs
•2-pipe fan coil unit
1 2 3 4 5
ON
OFF
•2-pipe fan coil unit
and electric heater
1 2 3 4 5
ON
OFF
•2-pipe fan coil unit
and radiator / floor
heating
1 2 3 4 5
ON
OFF
(B1)
M1
Y1
TB2
T
T
(B1)
Y1
M1
3076S02_01
T
YE
T
(B1)
T
(B1)
B2
(B1)
M1
Y1
T
B2
T
T
(B1)
YR
Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN
•2-pipe / 2-stage
fan coil unit
1 2 3 4 5
ON
OFF
•4-pipe fan coil unit
1 2 3 4 5
ON
OFF
•4-pipe fan coil unit
and electric heater
1 2 3 4 5
ON
OFF
Y1
M1
T
B2
T
(B1)
T
(B1)
Y2
T
Y2
Y1
M1
(B1)
T
(B1)
T
Y2
Y1 M1
3076S05_01
(B1)
T
(B1)
YE
B2
Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN Using RDG100KN
Product no.
Control outputs
Fan
RDG100KN
On/Off, PWM, 3-position
3-speed, 1-speed
RDG160KN
DC 0...10 V
3-speed, 1-speed, DC 0...10 V
RDG160KN
On/Off
DC 0...10 V
Remote configuration
4 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Applications for Universal systems
Applications, DIP setting, Control outputs
•Chilled / heated
ceiling
1 2 3 4 5
ON
OFF
•Chilled / heated
ceiling
and electric heater
1 2 3 4 5
ON
OFF
•Chilled / heated
ceiling and
radiator
/ floor heating
1 2 3 4 5
ON
OFF
3191S11
N1
T
B1
T
B2
T
D3
Y1
3191S12
N1
T
YE
B1
T
B2
T
D3
Y1
3191S14
N1
T
B1
T
B2
T
D3
Y1
YR
Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN
•2-stage chilled /
heated ceiling
1 2 3 4 5
ON
OFF
•Chilled ceiling
and radiator
1 2 3 4 5
ON
OFF
Y1
Y2
3191S13
N1
T
B1
T
D3
Y1
YR
Using RDG100KN, RDG160KN Using RDG100KN, RDG160KN
Product no.
Control outputs
RDG100KN
On/Off, PWM, 3-position
RDG160KN
On/Off, DC 0...10 V
5 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Applications for heat pump systems (RDG160KN)
Applications, DIP setting, Control outputs
•Heated or cooled with compressors
1 2 3 4 5
ON
OFF
•Heated or cooled with
compressors, with electric heater
1 2 3 4 5
ON
OFF
3181S31
N1
T
B1
T
D3
3181S32
N1
T
YE
B1
T
D3
Using RDG160KN Using RDG160KN
•Heated and cooled with
compressors
1 2 3 4 5
ON
OFF
•2-stage heated or cooled
with compressors
1 2 3 4 5
ON
OFF
3181S35
N1
T
B1
T
D3
3181S36
N1
T
B1
T
D3
2
Using RDG160KN Using RDG160KN
Product no.
Control outputs
Fan
RDG160KN
On/Off , DC 0...10 V
Disabled, DC 0...10 V
Key
Y1 Heating or heating / cooling valve actuator
M1 1-speed or 3-speed fan
Y2 Cooling valve actuator
YE Electric heater
B1 Return air temperature sensor or external room
temperature sensor (optional)
B2 Changeover sensor (optional)
RDG100KN
•Use P46 / P47 to change output from On / Off (factory setting) to PWM
•Use DIP switches 4 and 5 to change output from On/Off to 3-position
RDG160KN
•Use P46 / P47 to change valve actuator output from DC (factory setting) to On/Off
•Use DIP switch 4 to change fan output from DC (factory setting) to 3-speed
Notes
6 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Type summary
Product no.
Stock no.
Features
Operating
voltage
Number of control outputs Fan Backlit
LCD
On/Off
PWM
3-pos.
DC
3-stage
DC
RDG100KN
S55770-T163
AC 230 V
3 1)
2 1)
2 1)


RDG160KN S55770-T297 AC 24 V
2 2)
2 2)


2
3)
1) Selectable: On/Off, PWM or 3-position (triac outputs)
2) Either On/Off or DC control signal
3) 3-speed fan selectable only with DC outputs
Equipment combinations
Description Product no. Data
sheet
Cable temperature or
changeover sensor
QAH11.1 1840
Room temperature sensor
QAA32 1747
Condensation motion
QXA2601 /
QXA2602 /
QXA2603 /
QXA2604
3302
Electromotoric On/Off actuator
SFA21... 4863
Electromotoric On/Off valve and
actuator
(only available in AP, UAE, SA and IN)
MVI… / MXI… 4867
Zone valve actuator
(only available in AP, UAE, SA and IN)
SUA… 4832
Thermal actuator (for radiator valves)
AC 230 V, NO
STA23... *) 4884 *)
Thermal actuator (for radiator valves)
AC 24 V, NO
STA73... *) 4884 *)
Thermal actuator AC 230 V
(for small valves 2.5 mm), NC
STP23... *) 4884 *)
Thermal actuator AC 24 V
(for small valves 2.5 mm), NC
STP73... *) 4884 *)
Electrical actuator, 3-position
(for radiator valves)
SSA31... 4893
Electrical actuator, 3-position
(for 2- and 3-port valves / V…P45)
SSC31 4895
Electrical actuator, 3-position
(for small valves 2.5 mm)
SSP31… 4864
Electrical actuator, 3-position
(for small valves 5.5 mm)
SSB31... 4891
Electrical actuator, 3-position
(for small valve 5,5 mm)
SSD31... 4861
Electromotoric actuator, 3-position
(for valves 5.5 mm)
SQS35… 4573
On / off actuators
On / off and PWM
actuators *)
3-position actuators
7 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Electrical actuator, DC 0...10 V
(for radiator valves)
SSA61... 4893
Electrical actuator, DC 0...10 V
(for 2- and 3-port valves / V…P45)
SSC61… 4895
Electrical actuator, DC 0...10 V
(for small valves 2.5 mm)
SSP61… 4864
Electrical actuator, DC 0...10 V
(for small valves 5.5 mm)
SSB61... 4891
Electrical actuator, DC 0...10 V
(for CombiValves VPI45)
SSD61... 4861
Electromotoric actuator, DC 0...10 V
(for valves 5.5 mm)
SQS65… 4573
Electrothermal actuator,
AC 24 V, NC, DC 0…10 V, 1 m
STA63 4884
Electrothermal actuator,
AC 24 V, NO, DC 0…10 V, 1 m
STP63 4884
*) With PWM control, it is not possible to ensure exact parallel running of
more than one thermal actuator.
If several fan-coil systems are controlled by the same room thermostat, preference
should be given to motorized actuators with On/Off or 3-position control.
Note:
For the parallel operation of the actuators, refer to information in the data sheets of
the selected actuators and to this list, depending on which value is lower:
Maximum number of actuators in parallel on the RDG100KN
•max 6 SS…31.. actuators (3-pos)
•max 4 ST…23.. if used with On/Off control signal
•max 10 SFA.., SUA.., MVI.., MXI.. On/Off actuators
•Parallel operation of SQS35 is NOT possible
Maximum number of actuators in parallel on the RDG160KN
•max 10 SS…61.. actuators (DC)
•max 10 ST..23/63/73... actuators (DC or On/Off)
•max 10 SFA.., SUA.., MVI.., MXI … On/Off actuators
•max 10 SQS65 actuators (DC)
Accessories
Description
Product no. /
stock no.
Data
sheet
KNX Power supply 160 mA (Siemens BT LV)
5WG1 125-1AB02
--
KNX Power supply 320 mA (Siemens BT LV)
5WG1 125-1AB12
--
KNX Power supply 640 mA (Siemens BT LV)
5WG1 125-1AB22
--
DC 0…10 V actuators
8 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
Mechanical design
The room thermostat consists of 2 parts:
•Plastic housing with electronics, operating elements and room temperature
sensor
•Mounting plate with the screw terminals
The housing engages in the mounting plate and is secured with 2 screws.
1) Operating mode button / Esc
2) Fan mode button / Ok
3) Rotary knob to adjust setpoints and
parameters
Operation and settings
2
1
3
9 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23
#
Symbol
Description
#
Symbol
Description
1 Heating mode 14
Automatic fan
2
Heating mode,
electric heater active 15 Manual fan
3
Cooling mode
16
Fan speed
Fan speed 1
4 Comfort
Fan speed 2
5 Economy
Fan speed 3
6
Auto Timer mode according to
schedule (via KNX) 17
Degrees Celsius
Degrees Fahrenheit
8
Protection mode 18
Digits for room temperature and setpoint
display
9
Escape 19 Button lock
10
Additional user information, like out-
door temperature or time of day
from KNX bus. Selectable via
parameters
20 Condensation in room (dewpoint sensor active)
12
Morning: 12-hour format
Afternoon: 12-hour format 21
Weekday 1…7 from KNX bus
1 = Monday / 7 = Sunday
13
Confirmation of parameters 22
Fault
23
Temporary timer function; visible when
operating mode is temporarily extended
(extended presence or absence)
24
Indicates that room temperature is displayed
Display
10 / 21
Siemens RDG100KN, RDG160KN Room thermostats with KNX communications CE1N3191en
Building Technologies 2014-05-23