manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Thermostat
  8. •
  9. Siemens RDD810KN/NF User manual

Siemens RDD810KN/NF User manual

Other Siemens Thermostat manuals

Siemens Albatros RVS46 Series User manual

Siemens

Siemens Albatros RVS46 Series User manual

Siemens RDU341 Operator's manual

Siemens

Siemens RDU341 Operator's manual

Siemens RDG100KN Operator's manual

Siemens

Siemens RDG100KN Operator's manual

Siemens RDF301 User manual

Siemens

Siemens RDF301 User manual

Siemens KNX RDF600KN User manual

Siemens

Siemens KNX RDF600KN User manual

Siemens RDD100.1RFS User manual

Siemens

Siemens RDD100.1RFS User manual

Siemens Free Energy Band TH 193 HC Owner's manual

Siemens

Siemens Free Energy Band TH 193 HC Owner's manual

Siemens RDH100RF/SET User manual

Siemens

Siemens RDH100RF/SET User manual

Siemens RDG100 Series User manual

Siemens

Siemens RDG100 Series User manual

Siemens Retroline TH 192 User manual

Siemens

Siemens Retroline TH 192 User manual

Siemens Acvatix RTN81 User manual

Siemens

Siemens Acvatix RTN81 User manual

Siemens RDF800 User manual

Siemens

Siemens RDF800 User manual

Siemens RAB20 Series Owner's manual

Siemens

Siemens RAB20 Series Owner's manual

Siemens RDE100 Series User manual

Siemens

Siemens RDE100 Series User manual

Siemens RDD50.1 User manual

Siemens

Siemens RDD50.1 User manual

Siemens RAB10.1U User manual

Siemens

Siemens RAB10.1U User manual

Siemens RDG100T User manual

Siemens

Siemens RDG100T User manual

Siemens Free Energy Band TH 193 HC User manual

Siemens

Siemens Free Energy Band TH 193 HC User manual

Siemens RDS110 User manual

Siemens

Siemens RDS110 User manual

Siemens RAA20 User manual

Siemens

Siemens RAA20 User manual

Siemens RDF800KN User manual

Siemens

Siemens RDF800KN User manual

Siemens RDG400KN Operator's manual

Siemens

Siemens RDG400KN Operator's manual

Siemens RDJ10 User manual

Siemens

Siemens RDJ10 User manual

Siemens RDG400 Operator's manual

Siemens

Siemens RDG400 Operator's manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

s
3175
RDD81
0KN/NF
Touch Screen Flush-mount Room
Thermostats with KNX
Communications
For
heating applications
•KNX bus communications (S-mode and LTE mode)
•Large display with backlight
•2-position (ON/OFF) control with potential free output for heating
•2 multifunctional inputs for keycard, window contact, external temperature
sensor, presence detection, and etc.
•Operating modes: Comfort, Economy and Protection
•Minimum and maximum limitation of room temperature setpoint
•Control depending on the room or external temperature sensor
•Adjustable commissioning and control parameters
•Commissioning with Synco ACS, ETS4 or via local HMI
•Interoperation into Synco 700
•Integration into Desigo via group (ETS4) or via individual addressing
•Integration into third-party system via group addressing (ETS4)
•AC 230 V operating voltage
•RDD810KN/NF: Mounting on recessed square 86 mm box with 60.3 mm
fixing centers and min 40 mm depth, requires additional mounting frame
CB1N3175en
2016-03-10
Building Technologies
Use
Room temperature control in a heating system:
Typical applications:
•Apartments
•Commercial buildings
•Schools
For the control of the following pieces of equipment:
•Thermal valves or zone valves
•Gas or oil boilers
•Fans
•Pumps
•Floor Heating
The heating unit can be configured using one of the following tools via remote
configuration:
•Local HMI
•Synco ACS
•ETS4
Functions
•Room temperature control via built-in temperature sensor or external room
temperature sensor.
•Selection of operating mode via touch screen.
•Temporary Comfort mode extension.
•Display of current room temperature or setpoint in °C and/or °F.
•Minimum and maximum limitation of room temperature setpoint.
•Key lock function: unlock, total lock and setpoint
•2 multifunctional inputs, freely selectable for:
−Window contact
−Presence detector
−External room temperature or return air temperature sensor
−Fault input
−Monitor input for temperature sensor or switch state
•Floor heating temperature limitation.
•Reload factory settings for commissioning and control parameters.
•Wizard function for easy commissioning via HMI
•KNX bus (terminals CE+ and CE-) for communication with Synco 700 or KNX
compatible devices
•Display of time of day via KNX bus
•Display of outdoor temperature via KNX bus on INFO page
•Time scheduling and central control of setpoints via KNX bus
•With a Synco RMx7xx controller, the energy demand signal of the thermostat is
used to optimize energy supply.
Applications
The thermostat supports the heating applications:
•Hydronic floor heating controls
•Radiators
•Wall-hung boilers
2 / 16
Siemens RDD810KN… CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
Appication Examples
Room thermostat to control the valve of
the radiator application Room thermostat to control the valve for the
floor heating application
Room thermostat with direct control of a
gas-fired wall-hung boiler Room thermostat with direct control of a
gas-fired floor-standing boiler
Room thermostat with direct control of a
heat pump (pre-controlled by manual
mixing valve)
Room thermostat with direct control of
hydronic floor heating system
F1 Thermal reset limit thermostat
F2 Safety limit thermostat
M1 Circulating pump
N1 Room thermostat
V1 2-port valve
V2 Mixing 3-port valve with
manual adjustment
V3 Magnetic valve
3 / 16
Siemens RDD810KN.. CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
Type summary
Product no. Stock no. Operating
voltage Control outputs Suitable for
3-pos
ON/OFF
DC 0..10 V
RDD810KN/NF 2)
S55770-T336
AC 230 V
--
2
1)
--
Square conduit box
2)
1) ON/OFF output with potential free input from AC 24…230 V
2) Mounting frames are not included and must be ordered separately. See
“Accessories”
Ordering
•When ordering, indicate product number, SSN and name.
For example: RDD810KN/NF (S55770-T336) room thermostat
•A mounting frame must be ordered for RDD810KN/NF installation
(See “Accessories”)
•Order valve actuators separately.
Equipment combinations
Type of unit
Product no.
Data sheet
Cable temperature sensor or
changeover sensor
cable length 2.5 m
NTC (3 kΩat 25 °C)
QAH11.1 d) 1840
Room temperature sensor
NTC (3 kΩat 25 °C)
QAA32 1747
Cable temperature sensor,
cable length 4 m
NTC (3 kΩat 25 °C)
QAP1030/UFH 1854
Electromotoric ON/OFF actuator
SFA21... 4863
Electromotoric ON/OFF valve and
actuator
a)
MVI…/MXI… 4867
Zone valve actuators a)
SUA… 4832
Thermal actuator b)
STA23... 4884
Thermal actuator c)
STP23... 4884
Damper actuator
GDB.. 4634
Damper actuator
GSD.. 4603
Damper actuator
GQD.. 4604
Rotary damper actuator
GXD.. 4622
a) only available in AP, UAE, SA and IN
b) for radiator valve
c) for small valves 2.5 mm
ON/OFF actuators
4 / 16
Siemens RDD810KN… CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
d) both QAH11.1 and QAP1030/UFH are for floor heating applications, such as
temperature limitation controls. QAP1030/UFH has a special head and 4 m long
that is more suitable for such application
Refer to data sheets of the actuators for the maximum number of parallel
operation.
Accessories
Designation
Product no. / SSN
Data sheet
Conduit box for RDD810KN/NF
ARG71 /
S55770-T137 N3009
Single mounting frame
*)
, Ivory White
ARG800.1 /
S55770-T370
--
KNX Power supply 160 mA (Siemens BT LV)
5WG1 125-1AB02
--
KNX Power supply 320 mA (Siemens BT LV)
5WG1 125-1AB12
--
KNX Power supply 640 mA (Siemens BT LV)
5WG1 125-1AB22
--
*) See the dimensions of mounting frame on page 14.
Note:
5 / 16
Siemens RDD810KN.. CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
Mechanical design
The thermostats consist of the following parts:
•Front panel with electronics, operating elements and built-in room temperature
sensor.
•Mounting base with power electronics.
•Mounting frame is an additional part to complete the installation for
RDD810KN/NF.
The rear of the mounting base contains the screw terminals.
Slide the front panel in the mounting base and snap on.
Operation and
settings
Display
STATUS and
OPERATION of the
thermostat
INFORMATION
1
st
Line:
temperature, values
of parameters
2
nd
Line: parameter
numbers, time clock
ADJUSTMENT for temperature setpoint, operating modes and
settings (for example, Alarm, INFO, etc.)
SELECTION of
available INFO and
operating modes
Status symbols:
Key lock
Manual override
Alarm / Service reminder Heating active
Scheduler via bus
Selection symbols:
Indoor temperature
Comfort mode
Outdoor temperature Economy mode
Protection mode
Operational icons:
+ 
Increment, decrement OR selection

Selection OR move to next items
Temperature OR parameter values, and etc.
Time clock (12 / 24 hour), parameter number
OR password, and etc.
Setpoint mode (temperature only)
Operating mode
Setting mode
6 / 16
Siemens RDD810KN… CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
Engineering notes
See the "Reference documentation", page 12, for information on how to engineer
the KNX bus (topology, bus repeaters, etc.) and how to select and dimension
connecting cables for supply voltage and field devices.
Mounting and installation
Mount the room thermostat on a conduit box. Do not mount on a wall in niches or
between bookshelves, behind curtains, above or near heat sources, or exposed to
direct solar radiation. Mount about 1.5 m above the floor.
Mounting / Dismounting
•Do not apply excessive force on screws! The deformation of the mounting
frame may lead to improper connections and operation of the unit.
•Mount the room thermostat on a clean, dry indoor place without direct airflow
from a heating / cooling device, and not exposed to drips or water.
•Before removing the front cover, disconnect the power supply.
Wiring See the User Manual for the installation instructions enclosed with the thermostat.
•Comply with local regulations to wire, protection and earth the thermostat.
•The device has no internal fuse for supply lines to fan and actuators. To avoid
risk of fire and injury due to short-circuits, the AC 230 V mains supply line must
have a circuit breaker with a rated current of no more than 10 A.
•The wiring cross section used for power supply (L, N) and 230 V outputs
(Qxx - N) must be adapted to the preceding overload protection elements (max
10 A) under all circumstances. Comply under all circumstances with local
regulations.
•Properly size the cables to the thermostat and valve actuators for
AC 230 V mains voltage.
•Cables of SELV inputs X1-M / X2-M: Use cables with min 230 V insulation, as
the conduit box carries AC 230 V mains voltage.
•Inputs X1-M or X2-M of different units (e.g. window contact) may be connected
in parallel with an external switch. Consider overall maximum contact sensing
current for switch rating.
•KNX communication cables (input CE+ / CE-): Use cables with min 230 V
insulation, as the conduit box carries AC 230 V mains voltage.
•When a KNX bus power supply is connected on the line with communicating
thermostats and Synco controllers, the internal KNX power supply of the
Synco controllers must be switched off.
•No cables provided with a metal shield.
•Disconnect from supply before opening the cover.
7 / 16
Siemens RDD810KN.. CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
Commissioning notes
No DIP switch setting is required for RDD810KN... thermostats.
After power up, the wizard function guides users to configure the basic parameters
for normal operation according to the table below.
Touch / to advance / return to any parameter;
Touch +/ -to change value.
LCD display Parameter Range Factory setting
User operating
mode profile
1: comfort > protection
2: comfort > economy >
protection
1
Selection of
°C or °F
0: °C
1: °F 0
Standard display 0: Room temperature
1: Setpoint 0
Display info line
(2nd line of LCD
display)
0: --- (No display)
3: Time of day (12h) via bus
4: Time of day (24h) via bus
0
Functionality of X1
0: --- No function
1: Ext / Return Temp (AI)
3: Window open detect (DI)
6: Fault input (DI)
7: Monitor input (Digital)
8: Monitor input (Temp)
10: Presence detection (DI)
3
Functionality of X2 1
Operating action
of X1 Normal Open (NO)
Normal Close (NC) Normal Open
(NO)
Operating action
of X2
- End of wizard -
If more details are required about parameters, refer to basic documentation P3174.
To reload factory setting for all parameters, set parameter P71 to ON. Restart the
thermostat after reset, all LCD segments flash, indicating that the reset is correct.
3 seconds later, the thermostat is ready for commissioning by qualified HVAC staff.
Before power up
Wizard function
Reset
8 / 16
Siemens RDD810KN… CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
RDD810KN… thermostats are for heating applications. Configure or changing
parameter settings during commissioning using one of the following tools:
−Local HMI
−Synco ACS
−ETS4
Connect the Synco ACS or ETS4 tools to the KNX bus cable at any point for
commissioning:
L
N
X1 M X2
RDD810KN..
3171A03
CE+ CE-
KNX
ETS4
RS232
Siemens
N148 /
UP146 /
UP152
ETS4 / ACS
Siemens
OCI700
or
OCI702....
Q11 Q14 Q12
ACS and ETS4 require an interface:
−RS232 KNX interface (such as Siemens N148 / UP146 / UP152)
−OCI700 USB-KNX interface
An external KNX bus power supply is required if an RDD810KN/NF is connected
directly to a tool (ACS or ETS4) via KNX interface.
Applications
Connect tool
Note:
9 / 16
Siemens RDD810KN.. CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10
The thermostat's control parameters can be set to ensure optimum performance of
the entire system (refer to basic documentation P3174).
The parameters can be adjusted using
−Local HMI
−Synco ACS
−ETS4
For commissioning via local HMI, refer to user manual B3174... for setting the
passwords.
•Only heating sequence is available.
•Recalibrate the temperature sensor if the room temperature displayed on the
thermostat does not match the room temperature measured (after min. 1 hour of
operation). To do this, change parameter P05.
•We recommend to review heating setpoint and their range limitation via
parameters P08…P11. If necessary, adjust them to achieve maximum comfort
and save energy.
The programming mode helps identify the thermostat in the KNX network during
commissioning.
Touch and hold
for more than 5 seconds to activate programming mode, which
is indicated on the display with Pr09. Programming mode remains active until
thermostat identification is complete.
Assign device address (P81) via HMI, ACS or ETS4.
With device address set to 255, the communication is deactivated (no exchange of
process data).
Use ETS4 to assign the KNX group addresses of the RDD communication objects.
Each device has a unique KNX serial number inside the front panel. An additional
sticker with the same KNX serial number is enclosed in the packaging box. This
sticker is intended for installers for documentation purposes.
Disposal
The devices are considered electronics devices for disposal in terms of European
Directive 2012/19/EU and may not be disposed of as domestic waste.
•Dispose of the device via the channels provided for this purpose.
•Comply with all local and currently applicable laws and regulations.
Control parameters
Control sequence
Calibrate sensor
Setpoint and range
limitation
Programming mode
Assign KNX device
address
Assign KNX group
addresses
KNX serial number
10 / 16
Siemens RDD810KN… CB1N3175en
Building Technologies Touch Screen Flush-mount Room Thermostats with KNX Communications 2016-03-10