ACTION SCREEN
AREA
LOCATOR*
NOTES
[ ] Notes on Display
MODE / RESULT SCREEN
DISPLAYS
Power ON/OFF Press ON/OFF Switch
Lower Left-Hand Front Panel ON - Main Screen
OFF - Blank Screen
(See Notes)
Setup / Operation
Back Light ON/OFF
Contrast
On - Bright Screen
Off - Dark Screen
(See Notes)
Adjust ↑↑⁄↓↓ to Desired Level
[Use Up/Down Key]
Speaker Level Line Graph Adjust ↑↑⁄↓↓ to Desired Contrast
[Use Up/Down Key]
Z ( Impedance ) 50, 75, 135,
or 600 Steps Through Each Z (Impedance)
Vrms / dBm dBm or Vrms Switches Between Volts and dBm
Balanced or Unbalanced Input BAL or
UNBAL BAL: [Use + Red/- Blk Balanced Inputs]
UNBAL: [Use Lower Unbal. BNC Inputs]
(See Notes)
ACTION SCREEN
AREA
LOCATOR*
NOTES
[ ] Notes On Display
MODE / RESULT SCREEN
DISPLAYS
Set / Change a Bandwidth
DisplayAveraging ↑↑⁄↓↓ to Increase / Decrease Display
Averaging Samples
dB Reference Reading Becomes Reference
Enter dB Reference
Set Clock / Date
Maximum Hold Repeat to Turn Off
[Warning: Max Hold Is On]
Bridged Z / Hi Z Termination In InternalAttenuator,Allows Bridged Z
to be Programmed
Steps Freq./Level Steps. Change ↑↑⁄↓↓.
Repeat Action Changes Step
Clear Returns To Previous Value Prior To
Using ↑↑⁄↓↓ or # Keys
Enter Enters Input
2nd 10 Second Time-Out
Perm / Opt 2 Key Reserved For Future Use
Numeric Keys Use 1-0, +/-, and .As Required To Enter
Values
Frequency Selective Voltmeter (FSVM)
C O N T I N U E D
Enter FSVM Mode
AFC On / Off
Tune Frequency
Threshold Include +/- if Required. Value Disap-
pears
Search From Existing Frequency 1.) Search Up/Down From Existing
Frequency [Searching]
2.) To Stop Searching
Search Within a Range Last <ENTER> Starts Search
[Search Complete]
Enter Demod Mode
Select AM, USB, LSB, or DSB
OR
OR
12
OR OR
[Repeat For Start, Stop,
and Threshold]
x5 [Repeat]
MODEL 110MODEL 110
MODEL 110MODEL 110
MODEL 110
Quick Reference Guide
Repeat ↑↑⁄↓↓ - Enter for Each Parameter
[Use Enter and Up/Dwn For Time]
Default Mode
[Warning WillAppear if Max Hold is On]
[Use Up/Dwn Key or Enter Value]
* - Screen area locators are approximate
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25, 100, 1950,3100
5MHz and Wide
Line Graph
Reference Level
Reference Level
Date and Time
MAXHLD
N (Z) or High
“Value”
2ND
FSVM
On/Off
“Value”
“Value”
“Value”
AM, DSB,
USB, or LSB
AM, DSB,
USB, or LSB
Repeat Action to Toggle Through
Modulation Types
Repeat to Toggle Through Modulation
Types
Repeat Action to Turn On/Off
Must Be in FSVM Mode First
Selects Input Bandwidth in FSVM Mode
Selects Input Bandwidth in Wide Mode
Enter Level Desired Including +/- and .
OR For USB/DSB/LSB
Refer To User Guide for Details and Additional Information For SN 200 and higher