SIM-05
SHOCK AND GLASS
BREAKE DETECTOR
INSTALLATION INSTRUCTIONS
P/N 7107527 Rev A
DETECTOR PATTERN COVERAGE
The detector offers flexible installation. It
can be either ceiling mounted or wall
mounted as shown in the figure above.
If heavy blinds or curtains cover the glass, you
must locate the detector behind the blinds on
the window frame or above it, otherwise the
blinds might block the sound. Make sure to
test the unit thoroughly for proper detection.
Install the detector in a direct line of sight with
the protected glass.
Do not mount the unit in front of air ducts, or
close to bells (measuring 0.5m (or larger) in
diameter).
For a few protected glasses in one room,
locate the detector in optimal distance from
them to achieve the best detection.
SPECIFICATION
Sensor Microphone
Electro Condenser
Power Input 9 - 16 Vdc
Current Consumption Standby: 22mA at 12Vdc
Active: 25mA at 12Vdc
Detection Range 10m, Adjustable
Mounting Ceiling or Wall
Alarm Output Relay N.C 50mA/24Vdc with
27 Ohm in line resistor
Tamper Switch N.C 50mA 24Vdc with
10 Ohm in line resistor
Operating Temperature -20C to 50C
Operating Humidity 95% max relative
Range non condensing
Storage Temperature -30C to 70C
RFI Protection 30V/m 10 -1000MHz
EMI Protection 50,000V electrical
Interference from
lightning
Dimensions 78mm x 51mm x 21mm
INSTALLING THE DETECTOR
PCB LAYOUT
1. Use a small screwdriver to push the
prong on top of the case and open the
case.
2. Snap out the detector PCB.
3. Insert the wires through the wiring
hole (B).
4. Use the mounting holes (A) to mount
the detector.
5. Connect the wires to the
terminal.(See Terminal Connections)
6. Reinstall the detector PCB.
7. Close the case.
JUMPERS ( FIG. 4 )
JP1 - Shock / Glass selector for
detection calibration.
JP2 - Memory LED control.
JP3 - Reduces the sensitivity of
sound detection by 50%.
WIRE REQUIREMENTS
Use #22 AWG (0.5mm) or wires with a larger
diameter. Use the following table to determine
required wire gauge (diameter) and length of wire
between the detector and the control panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft 800 1200 2000 3400
Wire Gauge # 22 20 18 16
WIRE CONNECTIONS GLASS BREAK ADJUSTMENT
Terminal 1 - Marked - (GND)
Connect to ground of the control panel.
Terminal 2 - Marked + ( +12V )
Connect to the positive Voltage output of 9-16 Vdc source (usually from the alarm
control unit).
Terminals 3 & 4 - Marked TAMPER
If a Tamper function is required connect these terminals to a 24hour normally
closed protective zone in the control unit. If the front cover of the detector is
opened, an immediate alarm signal will be sent to the control unit.
Terminals 5 & 6 - Marked RELAY
These are the output relay contacts of the detector. Connect to the control at
zone input.
To adjust the glass break setting
(increase/decrease sensitivity) place the
jumper JP1 according the GLASS
marking (connecting the middle pin with
the upper pin) - Green LED is constantly
ON.
Now you can adjust the sensitivity by
rotating the upper potentiometer (marked
as GLASS CAL.).
Operate the Sound Break Simulator and
rotate the potentiometer clock-wise to
increase sensitivity, and counter-clock-
wise to decrease sensitivity until the
Yellow and Red LED’s are illuminating for
each glass break sound.
Remember that rotating the potentiometer
will have no effect upon the settings if the
middle pin of JP1 is not connected to the
upper pin.
Note
When the jumper is set for GLASS
adjustment, only the high frequency sound
of breaking glass is detected
SHOCK ADJUSTMENT
To adjust the shock setting
(increase/decrease sensitivity) place the
jumper JP1 according the SHOCK marking
(connecting the middle pin with the lower pin)
- Yellow LED is constantly ON.
Now you can adjust the sensitivity by rotating
the lower potentiometer (marked as SHOCK
CAL).
Hit gently on the protected glass and rotate
the potentiometer clock-wise to increase
sensitivity, and counter-clock-wise to
decrease sensitivity until the Green and Red
LED’s are illuminating for each hit.
Remember that rotating the potentiometer
will have no effect upon the settings if the
middle pin of JP1 is not connected to the
lower pin.
Note
When the jumper is set for SHOCK
adjustment, only the low frequency of the
shock signal prior to glass breakage is
detected.
MEMORY FUNCTION
The alarm memory function allows the
identification of an alerting detector out
of multiple detectors connected to one
(or the same) zone of the control
panel.
To enable this function, Set ON jumper
JP2 (MEM) (connected on both pins)
In case of an alarm, the Red LED
will stay ON until memory function
is reset.
To reset the memory function, switch
OFF (disconnect) the voltage wire
(+12V) from the TERMINAL BLOCK
for minimum 15 seconds then switch
on (reconnect) voltage wire (+12V).
(The control panel key ON/OFF can be
used for this application if it control the
voltage (+12V).
SENSITIVITY SETTING
For some installations you may find
that VIG is too sensitive. Use
JUMPER JP3 to decrease sensitivity to
50%.
JP3 OPEN - 100% sensitivity
JP3 CONNECTED - 50% sensitivity
www.sim-security.net

Other SIM Security Sensor manuals

SIM SIM-04 User manual

SIM

SIM SIM-04 User manual

SIM SIM-120 User manual

SIM

SIM SIM-120 User manual

SIM SIM2W-FLOOD-I User manual

SIM

SIM SIM2W-FLOOD-I User manual

Popular Security Sensor manuals by other brands

Dectris EIGER 2 XE CdTe 16M Technical specifications

Dectris

Dectris EIGER 2 XE CdTe 16M Technical specifications

IUP Fault Wizard user guide

IUP

IUP Fault Wizard user guide

Liberty SAFELERT user manual

Liberty

Liberty SAFELERT user manual

ITW SIMCO ION Perfomaster user manual

ITW

ITW SIMCO ION Perfomaster user manual

Code 3 RLS 3997 Installation & operation manual

Code 3

Code 3 RLS 3997 Installation & operation manual

Levenhuk Ermenrich Ping SM30 user manual

Levenhuk

Levenhuk Ermenrich Ping SM30 user manual

Pepperl+Fuchs KFD2-ELD-Ex16 manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-ELD-Ex16 manual

Busch-Jaeger Busch-Wächter 220 MasterLINE select 6847 AGS... quick start guide

Busch-Jaeger

Busch-Jaeger Busch-Wächter 220 MasterLINE select 6847 AGS... quick start guide

Marsen UTL-200 Operation and service manual

Marsen

Marsen UTL-200 Operation and service manual

Schmidt SS 20.420 Instructions for use

Schmidt

Schmidt SS 20.420 Instructions for use

Pfeiffer Vacuum MiniTest 300 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum MiniTest 300 operating instructions

Visonic TOWER 20 AM MCW installation instructions

Visonic

Visonic TOWER 20 AM MCW installation instructions

netvox R718PA7 user manual

netvox

netvox R718PA7 user manual

Bosch GMS 120 Original instructions

Bosch

Bosch GMS 120 Original instructions

Monacor PIR-100D manual

Monacor

Monacor PIR-100D manual

Iget SECURITY EP1 quick start guide

Iget

Iget SECURITY EP1 quick start guide

SICK KTX Prime manual

SICK

SICK KTX Prime manual

Crow GENIUS Installation instructions and instructions for use

Crow

Crow GENIUS Installation instructions and instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.