Siqura UP Series User manual

Document name: upxxseries_v1.1-IM-EN.docx
Installation manual
UP Series
UP33 and UP36 camera station

2 of 13 | P a g e
Copyright © 2020 Siqura B.V.
All rights reserved.
UPxx Series
Installation Manual v1
Nothing from this publication may be copied, translated, reproduced, and/or published
by means of printing, photocopying, or by any other means without the prior written
permission of Siqura.
Siqura reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective
owners.
Liability
Siqura accepts no liability for claims from third parties arising from improper use other
than that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably
comprehensive description of all relevant product components, this manual may
nonetheless contain errors and inaccuracies. We invite you to offer your suggestions and
comments by email via sales@siqura.com. Your feedback will help us to further improve
our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do
not hesitate to contact:
Siqura B.V.
Meridiaan 32
2801 DA Gouda The Netherlands
General : +31 182 592 333
Fax : +31 182 592 123
E-mail : sales@siqura.com
WWW : siqura.com
Note: To ensure proper operation, please read this manual thoroughly
before using the product and retain the information for future reference.

3 of 13 | P a g e
CONTENTS
1Important safety instructions............................................................................ 4
2Description..................................................................................................... 5
3Models........................................................................................................... 5
4Installation and connections ............................................................................. 5
4.1 Overview ................................................................................................. 5
4.2 Installing the optional IR Illuminator (UP-IR200)........................................... 6
4.3 Mounting with the optional wall bracket (UP-WM).......................................... 8
4.4 Connections ........................................................................................... 10
4.4.1 Power supply (4) .............................................................................. 10
4.4.2 Ethernet (3) ..................................................................................... 10
4.4.3 Washer control (1) ............................................................................ 11

4 of 13 | P a g e
1Important safety instructions
Prior to installation and operation, carefully read all instructions the in this manual and heed
all warnings.
Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper
immediately.
Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of
returning the equipment, the original packaging must be used.
Make sure that the installation surface can support at least four times the weight of the unit in normal
operating conditions. In case of excessive external stress (e.g. vibration, strong winds or impact), the
equipment may need additional means of protection.
Proper hardware should be carefully chosen to fasten the unit to the surfaces.
Use caution when lifting and assembling the unit. It is recommended that non-slip protective gloves be
worn during installation. The unit could bear sharp edges.
Trying to manually force the wiper will result in damaging the device and will void the warranty.
To maintain the IP rating of the unit, adequate cable glands must be used. The unit must be tightly
closed when operating.
For security reasons, do not install the unit in the proximity of water containers and never push objects
or pour liquids into the unit. The unit can be safely used in damp environments or outdoors, as long as
the connectors and lids are properly sealed.
Video and data cables should not share the same conduit with supply voltage cables. Whenever EMC
is an issue, adequately shielded cables must be used.
Open only the covers pointed out in this installation manual. Other covers should be open only by the
manufacturer.
This equipment has been designed to operate in harsh environments requiring little or no maintenance.
Suggested inspection interval is 6 months, but extremely harsh environments may require more
frequent inspection and maintenance checks. On each inspection check the O-ring seals and the
eventual window wiper blade integrity. Replace them if necessary.
Check cables, electrical connections and mounting hardware for integrity and tightness. Replace or
tighten any damaged/loose part.
Before performing any operation, turn off the power. The installation of the unit can be performed only
by qualified personnel in accordance with the regulations in force. Do not connect the unit to a supply
circuit unless the installation is completed.
Power the unit with 24 Vac / 3 A (75 W) power supply. Incorrect Power Supply Voltage may damage
the unit. Do not overload the terminal connection, as it may cause a fire or electrical shock hazard.
An all-pole mains switch with an opening distance between the contacts at least 3 mm in each pole
must be incorporated in the electrical installation. The switch must be equipped with protection against
the fault current towards the ground (differential) and the overcurrent (magnetothermal, maximum
15A). It must be very quickly recognizable and readily accessible. A suitable blow fuse must also be
installed for protection.
Fasten all the cables with cables ties or similar to avoid the electrical contact with surrounding parts
in case that terminal blocks screw off.
Electrical connections (such as plugs and cords) must be protected from potential hazardous
environmental factors (e.g. foot traffic, hitting objects).
Ensure that the unit case is properly earthed, connecting all the earth ground studs. Earth cable should
be about 10mm longer than the other cables on the connector, in such way that it won't be accidentally
disconnected if the cable is stretched or pulled.
When leaving the unit unused for long periods, disconnect supply cables.
Lightning or thunder may cause damage to the device. When installing the product, consider taking
measures that will minimize damage to the product in the event of lightning.

5 of 13 | P a g e
2Description
The Upright PTZ (UP33 or UP36) is a high-precision, full-featured network PTZ camera
providing high-quality, high-definition images. The robust construction of cast aluminium
and durable plastics ensures accurate positioning and stable video, both close by and at
large distances. The UPxx is designed to operate under extreme temperatures for
mission critical applications. It is tested and approved according the environmental
requirements of NEMA TS-2.
3Models
UP33 - Upright PTZ, 33x zoom, 24 Vac
UP36 - Upright PTZ, 36x zoom, 24 Vac
UP-IR200 - IR illumination kit for Upxx, 200m, 25°, 850 nm
UP-WM - Wall mount bracket for UPxx
4Installation and connections
4.1 Overview
1
Sunshield
2
Wiper
3
Main body
4
Base housing
5
Zoombox camera
6
Telemetry card
1
Washer control
2
Not connected
3
Ethernet (RJ45)
4
Camera and IR power

6 of 13 | P a g e
4.2 Installing the optional IR Illuminator (UP-IR200)
1. Secure the bracket to the camera with the 3 supplied bolts.
2. Connect the IR illuminators to the brackets. Lead the IR illuminator cable into the
housing through the cable-clamps in the bracket and insert it in the housing through the
cable-gland at the back of the housing.
3. Connect the IR-illuminator power cables and RS485
control cable with indicated terminals on the telemetry board.
Cable gland
Cable clamps

7 of 13 | P a g e
4. The default setting for IR-illumination control is
by the light-sensor. Both UP33 and UP36 controls
the illuminators by their Day/Night mode.
To have full control over the illuminators set
DIP Switch 8 to “Aux-control” (= OFF)
SW1:
1
ON
Reserved
2
ON
Reserved
3
OFF
Reserved
4
OFF
Reserved
5
OFF
Reserved
6
OFF
Reserved
7
OFF
Reserved
8
ON
OFF
Light sensor
Camera (Aux) control
5. When shipped from the factory, two IR illuminators are set to
different channels as Ch1 and Ch2.
The two IR illuminators cannot operate with the same channel.
To change the IR illuminator channels, remove the blind plug on
the backside of the IR-illuminator to access the DIP switch.
The channel is determined by DIP switch 2:
Channel 1 (left) Channel 2 (Right)
DIP switches 1 and 3 should always be set to “off”.

8 of 13 | P a g e
4.3 Mounting with the optional wall bracket (UP-WM)
1. Fix the wallmount bracket (UP-WM) using sturdy anchor bolts. Each bolt should be
able to hold at least 60 kg. (M10x30 is recommended)
2. Replace the rectangle shaped base-plate from the base housing with the wallmount
adapter.
3. Disassemble the wallmount cable management cover
Anchor bolts
(M10x30)
Washer
Rear gasket

9 of 13 | P a g e
4. Mount the UP33 or UP36 on the wallmount bracket. Lead the multicable tail through
the cable tray of the bracket.
5. Reassemble the cover of the wallmount bracket.

10 of 13 | P a g e
4.4 Connections
4.4.1 Power supply (4)
Recommend power supply wire specification:
4.4.2 Ethernet (3)
Ethernet cable should be CAT5e terminated with a RJ45. The max distance is 100m.
The RJ45 connection can be made waterproof (IP66) by using the “RJ45 water proof
accessory”, which is standard included.
Assemble the water proof RJ45 as shown in the drawing below.
1
Washer control
2
Not connected
3
Ethernet (RJ45)
4
Camera and IR power
Cable Label
Cable colour
Input
Main power
Brown
24 Vac, 3 A, 50/60 Hz
Blue
IR Illuminator power
Black
24 Vac, 3 A, 50/60 Hz
Green
Wire type
AWG22
AWG20
AWG18
Max cable length
34 m
55m
88m

11 of 13 | P a g e
4.4.3 Washer control (1)
The washer control is connected by the ALARM-out wires.
The connection diagram looks as follows:
Connection example with the Siqura washer tank SA-WP10-10m-VSF-24-v2
Cable Label
Cable colour
Remarks
ALARM IN
Black
Not used
GND
Brown
ALARM OUT NO
Red
Normally open (Washer)
ALARM OUT NC
Orange
Normally closed
ALARM OUT COM
Yellow
Common (Washer)
ALARM OUT NO (WASHER)
ALARM OUT NC
ALARM OUT COM (WASHER)
Washer tank
(SA-WP10-10m-VSF-24-v2)

12 of 13 | P a g e
Connection example with the SA-WP10-10m CSF-24 (or -230)
24Vac
UP33/UP36
Washer tank

13 of 13 | P a g e
This manual suits for next models
4
Table of contents
Other Siqura Digital Camera manuals