Sirona SIVISION Digital User manual

båÖäáëÜ
NOKOMNQ
kÉï=~ë=çÑW==
pfsfpflk=ÇáÖáí~ä
léÉê~íáåÖ=áåëíêìÅíáçåë=OO?=jçåáíçê obc=SQ=VT=QRO


Sirona Dental Systems GmbH Table of contents
Operating Instructions 22" Monitor
65 38 297 D3655
D3637.201.02.01.02 3
båÖäáëÜ
Table of contents
1General information .................................................................................................... 4
1.1 Dear Customer, ................................................................................................................................ 4
1.2 Contact data ..................................................................................................................................... 4
1.3 General information on the Operating Instructions ........................................................................... 5
1.4 Warranty and liability ........................................................................................................................ 5
1.5 Intended use ..................................................................................................................................... 6
1.6 Formats and symbols used............................................................................................................... 6
2Safety information....................................................................................................... 7
2.1 Identification of the danger levels ..................................................................................................... 7
2.2 Information on the unit ...................................................................................................................... 7
2.3 Maintenance and repair .................................................................................................................... 7
2.4 Modifications and extensions of the system ..................................................................................... 8
2.5 Danger of electric shock ................................................................................................................... 8
2.6 Electromagnetic compatibility ........................................................................................................... 8
2.7 Dismantling/Installation..................................................................................................................... 8
3Unit description ........................................................................................................... 9
3.1 Standards/approvals......................................................................................................................... 9
3.2 Technical data .................................................................................................................................. 9
3.3 External Dimensions Landscape ...................................................................................................... 11
4Operation ..................................................................................................................... 12
4.1 Operating and display elements ....................................................................................................... 12
4.2 Brightness......................................................................................................................................... 13
4.3 Contrast ............................................................................................................................................ 13
4.4 Color Mode ....................................................................................................................................... 13
4.5 User .................................................................................................................................................. 14
4.6 Management..................................................................................................................................... 14
5Care and cleaning instructions for the practice team ............................................. 21
5.1 Care and cleaning agents................................................................................................................. 21
5.2 Care and cleaning of the monitor...................................................................................................... 21
6Disposal ....................................................................................................................... 22

1 General information Sirona Dental Systems GmbH
1.1 Dear Customer, Operating Instructions 22" Monitor
65 38 297 D3655
4D3637.201.02.01.02
1 General information
1.1 Dear Customer,
You have decided to equip your dental treatment center with the integrated
SIVISION digital communication system from Sirona.
As such, you have made a significant step towards improving your patient
communication. You can therefore easily discuss the source situation, status
and the success of treatment with your patients. For indeed a picture says
more than a thousand words.
These Operating Instructions are designed to assist you prior to initial use and
whenever you require information later on.
Your Sirona Team
1.2 Contact data
Worldwide customer service
Customer service center For technical questions, use the contact form on the internet at
www.sirona.com. Follow the menu items "CONTACT"/"Customer Service
Center" on the navigation bar and click on the "CONTACT FORM FOR TECH-
NICAL QUESTIONS" button.
Manufacturer's address (worldwide)
Sirona Dental Systems GmbH
Fabrikstrasse 31
64625 Bensheim
Germany
Phone: +49 (0) 6251/16-0
Fax: +49 (0) 6251/16-2591
E-mail: [email protected]
www.sirona.com

Sirona Dental Systems GmbH 1 General information
Operating Instructions 22" Monitor 1.3 General information on the Operating Instructions
65 38 297 D3655
D3637.201.02.01.02 5
1.3 General information on the Operating Instructions
Observing the operating instructions
Observing the operating
instructions
Please familiarize yourself with the unit by reading through these operating
instructions before putting them into operation. It is essential that you comply
with the specified warning and safety information.
Storing documents, online portal, help
Keep documents safe Always keep the operating instructions handy in case you or another user
require(s) information at a later point in time. Save the operating instructions
on the PC or print them out.
Should you subsequently sell the unit, ensure that the operating instructions
are included with the unit in paper form or as electronic storage media so that
the new owner can be suitably informed about the function of the unit and the
warning and safety information provided.
Online portal for technical
documents
For technical documents, we have created an online portal at http://
www.sirona.com/manuals. There, you can download these operating instruc-
tions and further documents. If you prefer a document in paper format, please
fill out the web form. We would be delighted to send you a printed copy, free
of charge.
Help If you reach an impasse despite having thoroughly studied the operating
instructions, please contact your dental depot.
1.4 Warranty and liability
Warranty passport To safeguard your warranty claims, please complete the attached "Installation
Report / Warranty Passport" together with the service engineer immediately
after the installation of your unit.
Exclusion of liability In the event that the system owner fails to fulfill the obligation to perform
scheduled inspections and preventive maintenance activities or ignores error
messages, Sirona Dental Systems GmbH and its authorized dealers cannot
assume any liability for damages.

1 General information Sirona Dental Systems GmbH
1.5 Intended use Operating Instructions 22" Monitor
65 38 297 D3655
6D3637.201.02.01.02
1.5 Intended use
The 22" monitor is intended for use on dental units made by Sirona.
It serves for viewing intraoral images and any other images resulting from the
PC connection.
This device is not intended for operation in areas subject to explosion hazards.
1.6 Formats and symbols used
The formats and symbols used in this document have the following meaning:
IMPORTANT
If the monitor is used to diagnose X-ray images, special proof is required
from the user in terms of the ambient conditions specifying that the monitor
is suitable for diagnostic purposes. Please observe the relevant national
regulations.
The acceptance test can be performed using the SIDEXIS program, for
example. The document entitled "SIDEXIS, digital radiology in dentistry, per-
forming acceptance testing on image display devices for diagnosing with
SIDEXIS" (REF 6088699) describes the procedure.
Prerequisite
1.First action step
2.Second action step
or
➢Alternative action
Result
Prompts you to do something.
See "Formats and symbols
used [ →6]“
Identifies a reference to another text
passage and specifies its page num-
ber.
●List Designates a list.
"Command/menu item" Identifies commands, menu items or
quotations.

Sirona Dental Systems GmbH 2 Safety information
Operating Instructions 22" Monitor 2.1 Identification of the danger levels
65 38 297 D3655
D3637.201.02.01.02 7
2 Safety information
2.1 Identification of the danger levels
Identification of the danger levels
To prevent personal injury and material damage, please observe the warning
and safety information provided in the present operating instructions. Such
information is highlighted as follows:
Tip: Information on making work easier.
2.2 Information on the unit
This symbol can be found on the rating plate on the unit.
Meaning: The accompanying documents are available on the Sirona homep-
age.
2.3 Maintenance and repair
As manufacturers of dental medical units and in the interest of the operational
safety of your system, we stress the importance of having maintenance and
repair of this unit performed only by ourselves or by agencies expressly autho-
rized by us. Furthermore, failed components must always be replaced with
original spare parts.
DANGER
An imminent danger that could result in serious bodily injury or death.
WARNING
A possibly dangerous situation that could result in serious bodily injury or
death.
CAUTION
A possibly dangerous situation that could result in slight bodily injury.
ATTENTION
A possibly harmful situation which could lead to damage of the product
or an object in its environment.
IMPORTANT
Application instructions and other important information.

2 Safety information Sirona Dental Systems GmbH
2.4 Modifications and extensions of the system Operating Instructions 22" Monitor
65 38 297 D3655
8D3637.201.02.01.02
2.4 Modifications and extensions of the system
Modifications to this system which might affect the safety of the system owner,
patients or other persons are prohibited by law.
For reasons of product safety, this product may be operated only with original
Sirona accessories or third-party accessories expressly approved by Sirona.
The user assumes the risk of using non-approved accessories.
If any devices not approved by Sirona are connected, they must comply with
the applicable standards, e.g.:
●IEC 60950-1 for information technology equipment (e.g. PC) and
●IEC 60601-1 for medical electrical equipment.
The loudspeaker port of the monitor may be connected only to a device that
complies with IEC 60950 (e.g. a PC) or
IEC 60601-1. Under no circumstances may it be connected to a stereo sys-
tem, or similar, for example.
If a system is created during the installation process, the requirements of IEC
60601-1, 3rd edition, must be fulfilled.
2.5 Danger of electric shock
To prevent the danger of fire or of electric shock, the product must not be
exposed to rain or moisture.
Please do not open or dismantle the unit, as otherwise there will be a risk of
electric shock.
2.6 Electromagnetic compatibility
Medical electrical equipment is subject to special precautionary measures with
regard to electromagnetic compatibility (EMC). It must be installed and oper-
ated in compliance with the specifications provided for the respective treat-
ment center in the document "Installation Requirements".
Portable and mobile RF communications equipment may interfere with medi-
cal electrical equipment. Therefore, the use of mobile wireless phones in med-
ical office or hospital environments must be prohibited.
To ensure safe operation from the standpoint of EMC, please observe the
chapter entitled "Electromagnetic compatibility" in the document "Installation
Requirements".
2.7 Dismantling/Installation
Follow the installation instructions
When dismantling and reinstalling the unit, proceed according to the installa-
tion instructions for new installation in order to guarantee its proper functioning
and stability.
Explosion-hazard areas
This unit must not be used in areas subject to explosion hazards.

Sirona Dental Systems GmbH 3 Unit description
Operating Instructions 22" Monitor 3.1 Standards/approvals
65 38 297 D3655
D3637.201.02.01.02 9
3 Unit description
3.1 Standards/approvals
The 22" monitor complies with the following standards:
●IEC 60950-1 (information technology equipment, e.g. PC)
●IEC 60601-1-2 (electromagnetic compatibility)
3.2 Technical data
Model designation: 22" monitor
LCD display: 21.5" TFT Color TFT Normally Black
Display size: 476.6 (H) x 268.1 (V) mm
Pixel spacing: 0.248 (H) x 0.248 (V) mm
Display mode: VESA 1024 x 768 with 60 Hz
VESA 1280 x 1024 with 60 Hz
VESA 1280 x 720 with 60 Hz
VESA 1600 x 900 with 60 Hz
VESA 1920 x 1080 with 60 Hz
Maximum resolution: WUXGA 1920 x 1080 with 60 – 70 Hz
Pixel error rate: according to ISO 13406-2:2001 Class 2
Contrast ratio: > 350:1
Brightness: > 220 cd/m²
Display color: 16.7 M (6 bit + A-FRC)
Perspective: 178° (vertical / horizontal)
Loudspeakers: 2 x 2 W
Input signal: Stereo jack 3.5 mm
21-pos. HDMI connector
20-pos. display port connector
Dimensions: 537,7 mm (H) x 328,9 mm (W) x 59 mm (D)
Weight: ~7.0 kg
Mode of operation Continuous operation
Nominal voltage: 12 V DC
Rated current: 4,5 A
Protection class: Class Iunit – with protective conductor connector
Degree of protection
against ingress of water:
Ordinary equipment (IP X0 – without protection
against ingress of water)

3 Unit description Sirona Dental Systems GmbH
3.2 Technical data Operating Instructions 22" Monitor
65 38 297 D3655
10 D3637.201.02.01.02
Transport and storage
conditions:
Temperature: -20 °C – +60 °C
(-4 °F - 140 °F)
Relative humidity: 10 % – 95 %
Airpressure:500hPa–1060hPa
Operating conditions: Ambient temperature: 10 °C – 40 °C
(50 °F – 104 °F)
Relative humidity: 10 % – 85 %
no condensation
Airpressure:700hPa–1060hPa

Sirona Dental Systems GmbH 3 Unit description
Operating Instructions 22" Monitor 3.3 External Dimensions Landscape
65 38 297 D3655
D3637.201.02.01.02 11
3.3 External Dimensions Landscape
• The specifications and appearance will be changed for improvement
without notice

4 Operation Sirona Dental Systems GmbH
4.1 Operating and display elements Operating Instructions 22" Monitor
65 38 297 D3655
12 D3637.201.02.01.02
4 Operation
4.1 Operating and display elements
2 1
No. Control Function
Control Dial The Control Dial is a multi-functional device located behind the LED Indicator on the right
side of the front bezel. It has three movements-rotate upward, rotate downward and press
inward as a button.
Power On/Off
Press the Control Dial to power the unit on from the off stage (the LED is off). To turn the
power off, press the Control Dial and hold for at least 1 second until the LED turns off.
OSD Control
While the monitor is on (green LED and image on the screen),Pressing on the Control Dial
activates the OSD. While the OSD menu is active, use the three way movements of the
Control Dial to adjust the monitor.Rotate Downward: Move Up/Right, Increase, Larger, Mor-
eRotate Upward: Move Down/Left, Decrease, Smaller, LessButton Press: Execute, Do,
Save
LED Indicator This LED indicator turns green when the power is switched ON and the power cord is prop-
erly attached. It turns amber when the monitor goes into a power saving mode (Active Off).
Please refer to the Power Management section of manual for more information.
1
2

Sirona Dental Systems GmbH 4Operation
Operating Instructions 22" Monitor 4.2 Brightness
65 38 297 D3655
D3637.201.02.01.02 13
4.2 Brightness
Adjust brightness of the screen. The larger the value
is, the screen is , and vice versa. Adjustable at the
range from 0 to 100 by a couple of steps.
4.3 Contrast
Adjust contrast of the screen. The larger the value is,
the screen is , and vice versa. Adjustable at the range
from 0 to 100 by a couple of steps..
4.4 Color Mode
User can make tone adjustments and settings.
• Exit: Return to Main Menu.
• Cool: Bluish white for general use and CAD / CAM.
8000K is a fixed value by the manufacturer; User can-
not change the setting value.
• Neutral: White close to natural light used for publish-
ing trade. 6500K is a fixed value by the manufacturer;
User cannot change the setting value.
• Warm: Reddish white mainly suited for photo modi-
fication. 5400K is a fixed value by the
manufacturer; User cannot change the setting value.
• 9300K: 9300K is a fixed value (0.284±0.03,
0.299±0.03) by the manufacturer.
• 5800K: 5800K is a fixed value (0.326±0.03,
0.335±0.03) by the manufacturer.Color temperature
(RGB mode only)

4 Operation Sirona Dental Systems GmbH
4.5 User Operating Instructions 22" Monitor
65 38 297 D3655
14 D3637.201.02.01.02
4.5 User
User can adjust and set tones.
• Exit: Return to Main Menu.
• Red: Adjust red and equivalent colors at the range
from 0 to 100.
• Green: Adjust green and equivalent colors at the
range from 0 to 100.
• Blue: Adjust blue and equivalent colors at the range
from 0 to 100..
4.6 Management
• Exit: Return to Main Menu.

Sirona Dental Systems GmbH 4Operation
Operating Instructions 22" Monitor 4.6 Management
65 38 297 D3655
D3637.201.02.01.02 15
4.6.1 Scaling
You can select the control to adjust below items relate
to image scaling of Main channel.
• Exit: Return to Main Menu.
4.6.2 OSD Display
• Exit: Return to Main Menu.
4.6.2.1 OSD H. Position
Adjust the horizontal position of OSD. When rotating
control dial clockwise, OSD moves to the right, and
vice versa.

4 Operation Sirona Dental Systems GmbH
4.6 Management Operating Instructions 22" Monitor
65 38 297 D3655
16 D3637.201.02.01.02
4.6.2.2 OSD V. Position
Adjust the vertical position of OSD. When rotating
control dial clockwise, OSD moves to the up, and vice
versa.
4.6.3 Language
Selecting this control to select the language you want.
• English: Display OSD in English.
• Francais: Display OSD in Francais.
• Deutsch: Display OSD in Deutsch.
• Espanol: Display OSD in Espanol.
• Italiano: Display OSD in Italiano.
• Japanese: Display OSD in Japanese.
4.6.4 Source
Selecting this control allows you to manually select
HDMI or Display Port to automatically detect input
sources all.
• Exit: Return to Main Menu.
• HDMI: Display signal from HDMI connector.
• Displayport: Display signal from Displayport con-
nector.

Sirona Dental Systems GmbH 4Operation
Operating Instructions 22" Monitor 4.6 Management
65 38 297 D3655
D3637.201.02.01.02 17
4.6.5 Recall
Initialize the data such as display position and auto-
matic adjustment data to factory default.
4.6.6 Audio
4.6.6.1 Audio (HDMI)
Below menu is under HDMI Source.
• Exit: Return to Main Menu.
4.6.6.1.1 Mute
To control the audio sound of monitor.
• ON: mute
• Off: no mute

4 Operation Sirona Dental Systems GmbH
4.6 Management Operating Instructions 22" Monitor
65 38 297 D3655
18 D3637.201.02.01.02
4.6.6.1.2 Volume
Adjust the volume of the audio sound.Selecting this
control to volume a scaling. At the range from 0 to
100.
4.6.6.1.3 Audio Source
Selecting this control allows you to manually select
Audio source from HDMI or Line-In.
• Exit: Return to Main Menu.
4.6.6.2 Audio (Displayport)
Below menu is under Displayport Source.
• Exit: Return to Main Menu.

Sirona Dental Systems GmbH 4Operation
Operating Instructions 22" Monitor 4.7 Operation Hours
65 38 297 D3655
D3637.201.02.01.02 19
4.6.6.2.1 Mute
To control the audio sound of monitor.
• ON: mute
• Off: no mute
4.6.6.2.2 Volume
Adjust the volume of the audio sound.Selecting this
control to volume a scaling. At the range from 0 to
100.
4.7 Operation Hours
Show Monitor's working time.
• Exit: Return to Main Menu.

5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH
5.1 Care and cleaning agents Operating Instructions 22" Monitor
65 38 297 D3655
20 D3637.201.02.01.02
5 Care and cleaning instructions for the
practice team
5.1 Care and cleaning agents
You will find a list of all agents approved at the time of
delivery in the documentation folder supplied with
your treatment center.
A continuously updated list of approved agents can
be downloaded from the Sirona internet homepage
under REF 59 70 905: www.sirona.com
If you do not have Internet access, you can use one
of the following two ways to order the list:
• Order from your local dental depot
• Order from Sirona
Tel: ++49 (0) 62 51 / 16-16 16
FAX: ++49 (0) 62 51 / 16-18 18
5.2 Care and cleaning of the monitor
Cleaning
Remove any dirt and disinfectant residues regularly
using a mild commercial cleaning agent.
Do not use any colored cloths for cleaning, since they
may cause discoloration of the surfaces, e.g. in com-
bination with disinfectants!
Disinfecting
The glass screen and housing of the monitor can be
disinfected by wiping them with a soft cloth.
ATTENTION
Use only cleaning and care agents which are
approved by Sirona!
ATTENTION
Never use corrosive cleaning agents, wax or sol-
vents.
ATTENTION
Use only cleaning agents which have been
approved by Sirona (see above, "Care and cleaning
agents")!
ATTENTION
Never spray the monitor with a disinfectant or clean-
ing agent!