The Proflame transmitter is an integrated part of the Proflame System, which consists of these elements:
•
Proflame transmitter, to be used in conjunction with Integrated Fireplaces Control (Proflame IFC)
The Proflame transmitter provides for controlling the following hearth appliance functions:
1. Main Burner On/Off
2. Main Burner flame modulation (6 levels)
3. Choice of continuous or intermittent pilot (CPI/IPI)
4. Thermostat and smart thermostat functions
5. Accent light modulation (6 levels)
6. Split flow valve
7. On/Off relay
8. Comfort Fan speed modulation (6 levels)
The Proflame transmitter uses a streamlined design with a simple button layout and informative LCD display
(Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or
index through Thermostat functions (Fig. 1 & 2). Additionally, a Key Lock feature is provided (Fig. 23).
Fig. 1: Proflame transmitter
Back lit LCD display
UP/DOWN Arrow Key
ON/OFF Key
THERMOSTAT Key
MODE Key
Fig. 2: Transmittter LCD display.
Low battery
alarm
Key Lock
Room
Temperature
Dimmer ON
Set Point
Temperature/Level/State
Flame ON
Thermostat OFF/
ON/SMART
Comfort fan
Transmitting
Split Flow
Aux ON
CPI ON
Fig. A: Detach the adapter from the body
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES.
PLACING THE TRANSMITTER IN OR NEAR METAL MAY SEVERELY REDUCE THE
SIGNAL RANGE.
METALLIC STRUCTURES OR RADIO INTERFERENCES CAN REDUCE THE OPERATIVE DISTANCE
OF THE DEVICE DEPENDING ON TYPE OF FIREPLACE, INSTALLATION AND ENVIROMENT.
ATTENTION!
- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR
MAINTENANCE OF THE RECEIVER DEVICE.
- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR
REINSERTING THE BATTERIES.
- IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE IFC DEVICE USING
THE “ON/OFF” MAIN SWITCH.
- FOR INSTALLATION/MAINTENANCE SWITCH OFF THE IFC DEVICE REMOVING MAIN
POWER SUPPLY PLUG.
- THE DEVICE IS NOT SUITABLE FOR THE USE OF RECHARGABLE BATTERIES AND ITS
OPERATIVE DISTANCE IS REDUCED WITH LOW BATTERY LEVEL.
Remote Control
Supply voltage 4.5 V (three AAA LR03 1.5 V batteries)
Ambient temperature ratings 0 - 50 °C (32 - 122 °F)
Typical operative distance in free air 12 m (39 ft)
Radio frequency 315 MHz ( FCC version )
433.92 MHz ( CE version )
TECHNICAL DATA
The Proflame remote control is supplied with an adapter for wall mounting.
Installthecontroller1.5m(5ft) abovefloorlevel,wellawayfromheatsources,kitchens,doorsorwindows.
Metallic structures or radio interferences can reduce the operative distance of the device.
Make sure to attach the adapter in a level plane without any distortion. Proceed as follow:
• Detach the adapter from the body of the remote control; see Fig. A.
• Position the adapter on the wall, mark the points for the fixing holes and drill the wall.
• Fix the adapter on the wall using the mounting hardware supplied with the remote control.
• Insert the remote control onto the adapter as shown in Fig. B.
WALL MOUNTING
9955126_A00_Proflame_Wall_Mount_2 2 24/02/2014 15.41.57

3
IMPORTANT
The Proflame transmitter is an integrated part of the Proflame System, which consists of these elements:
•
Proflame transmitter, to be used in conjunction with Integrated Fireplaces Control (Proflame IFC)
The Proflame transmitter provides for controlling the following hearth appliance functions:
1. Main Burner On/Off
2. Main Burner flame modulation (6 levels)
3. Choice of continuous or intermittent pilot (CPI/IPI)
4. Thermostat and smart thermostat functions
5. Accent light modulation (6 levels)
6. Split flow valve
7. On/Off relay
8. Comfort Fan speed modulation (6 levels)
The Proflame transmitter uses a streamlined design with a simple button layout and informative LCD display
(Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or
index through Thermostat functions (Fig. 1 & 2). Additionally, a Key Lock feature is provided (Fig. 23).
Low battery
alarm
Key Lock
Room
Temperature
Dimmer ON
Set Point
Temperature/Level/State
Flame ON
Thermostat OFF/
ON/SMART
Comfort fan
Transmitting
Split Flow
Aux ON
CPI ON
Fig. A: Detach the adapter from the body
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES.
PLACING THE TRANSMITTER IN OR NEAR METAL MAY SEVERELY REDUCE THE
SIGNAL RANGE.
METALLIC STRUCTURES OR RADIO INTERFERENCES CAN REDUCE THE OPERATIVE DISTANCE
OF THE DEVICE DEPENDING ON TYPE OF FIREPLACE, INSTALLATION AND ENVIROMENT.
ATTENTION!
- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR
MAINTENANCE OF THE RECEIVER DEVICE.
- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR
REINSERTING THE BATTERIES.
- IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE IFC DEVICE USING
THE “ON/OFF” MAIN SWITCH.
- FOR INSTALLATION/MAINTENANCE SWITCH OFF THE IFC DEVICE REMOVING MAIN
POWER SUPPLY PLUG.
- THE DEVICE IS NOT SUITABLE FOR THE USE OF RECHARGABLE BATTERIES AND ITS
OPERATIVE DISTANCE IS REDUCED WITH LOW BATTERY LEVEL.
Remote Control
Supply voltage 4.5 V (three AAA LR03 1.5 V batteries)
Ambient temperature ratings 0 - 50 °C (32 - 122 °F)
Typical operative distance in free air 12 m (39 ft)
Radio frequency 315 MHz ( FCC version )
433.92 MHz ( CE version )
TECHNICAL DATA
The Proflame remote control is supplied with an adapter for wall mounting.
Installthecontroller1.5m(5ft) abovefloorlevel,wellawayfromheatsources,kitchens,doorsorwindows.
Metallic structures or radio interferences can reduce the operative distance of the device.
Make sure to attach the adapter in a level plane without any distortion. Proceed as follow:
• Detach the adapter from the body of the remote control; see Fig. A.
• Position the adapter on the wall, mark the points for the fixing holes and drill the wall.
• Fix the adapter on the wall using the mounting hardware supplied with the remote control.
• Insert the remote control onto the adapter as shown in Fig. B.
WALL MOUNTING
Fig. B: Adapter and remote control
9955126_A00_Proflame_Wall_Mount_3 3 24/02/2014 15.42.07

4
Initializing the System for the first time
1. Power the receiver (install receiver batteries if necessary).
2. Turn the receiver control on, or verify the receiver control
is on.
3. Activate the programming mode on the receiver
according to the receiver instructions (NOTE: The receiver
may be independent or integrated to the IFC (Ignitions
and Flame Control) hearth appliance control module.
The receiver instructions may be included with the IFC if
an integrated system.)
4. The receiver will “beep” three (3) times to indicate that it
is ready to synchronize with a transmitter.
5. Install three AAA batteries in the transmitter, located as
shown in Fig. 3.
6. The receiver will “beep” four times to indicate the
transmitter’s command is accepted and sets to the
particular code of that transmitter.
7. The system is now initialized.
OPERATING PROCEDURE
Turn on the Appliance
With the system OFF, press the ON/OFF Key on the
transmitter. The transmitter display will show some other
active icons on the screen. At the same time the receiver
wil activate the appliance. A single “beep” from the
receiver will confirm reception of the command.
Turn off the Appliance
With the system ON, press the ON/OFF Key on the
transmitter. The transmitter LCD display will only show
the room temperature (Fig. 6). At the same time the
receiver will turn off the appliance. A single “beep” from
the receiver confirms reception of the command.
Fig. 6: Remote Control display.
Temperature indication Display
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same
time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of
the Room Temperature display. (Fig. 4 and fig. 5)
Fig. 3: Battery compartment.
Fig. 4: Remote Control display in Farenheit. Fig. 5: Remote Control display in Celsius.
Remote-Flame Control
The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum
in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step
until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed
while the system is on but the flame is off, the flame will come on in the high position setting.
( Fig. 7 & 8 )
A single “beep” will confirm reception of the command.
Fig. 9 Fig. 10
SET TEMPERATURE
ROOM TEMPERATURE
Room Thermostat ( Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat can be set to a desired
temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The LCD display on the transmitter
will change to show that the room thermostat is “ON” and the set temperature is now
displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the transmitter.
Fig. 7: Flame Off Flame Level 1
Fig. 8: Flame level 5 Flame Level Maximum
9955126_A00_Proflame_Wall_Mount_4 4 24/02/2014 15.42.15

5
Turn on the Appliance
With the system OFF, press the ON/OFF Key on the
transmitter. The transmitter display will show some other
active icons on the screen. At the same time the receiver
wil activate the appliance. A single “beep” from the
receiver will confirm reception of the command.
Turn off the Appliance
With the system ON, press the ON/OFF Key on the
transmitter. The transmitter LCD display will only show
the room temperature (Fig. 6). At the same time the
receiver will turn off the appliance. A single “beep” from
the receiver confirms reception of the command.
Fig. 6: Remote Control display.
Temperature indication Display
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same
time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of
the Room Temperature display. (Fig. 4 and fig. 5)
Fig. 3: Battery compartment.
Fig. 4: Remote Control display in Farenheit. Fig. 5: Remote Control display in Celsius.
Remote-Flame Control
The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum
in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step
until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed
while the system is on but the flame is off, the flame will come on in the high position setting.
( Fig. 7 & 8 )
A single “beep” will confirm reception of the command.
Fig. 9 Fig. 10
SET TEMPERATURE
ROOM TEMPERATURE
Room Thermostat ( Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat can be set to a desired
temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The LCD display on the transmitter
will change to show that the room thermostat is “ON” and the set temperature is now
displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the transmitter.
Fig. 7: Flame Off Flame Level 1
Fig. 8: Flame level 5 Flame Level Maximum
9955126_A00_Proflame_Wall_Mount_5 5 24/02/2014 15.42.18

6
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the difference
between the set point temperature and the actual room temperatures. As the room
temperature gets closer to the set point the Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word "SMART" appears to
the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the desidered set
temperature is displayed on the LCD screen of the transmitter (Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be
controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the
Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep”
will confirm reception of the command.
Fig. 11: Smart flame function Fig. 12
Fig. 13 Fig. 14
Continous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon
(fig. 17 & 18).
Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode (CPI). Pressing the
Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.
NOTE: this function is available only with Proflame IFC.
NOTE: If the system is equipped with a CPI/IPI toggle switch:
• Set the CPI/IPI switch to CPI position(switch closed) to enable remote CPI/IPI
operation.
• Set the CPI/IPI switch to IPI position (switch open) to disable remote CPI/IPI
operation. The system will now work in IPI mode only regardless of the selection on
the remote control hand set.
Remote auxiliary relay control
The auxiliary function controls the AUX relay outlet. To activate this function use the Mode Key
(fig. 1) to index to the AUX icon (fig. 15 & 16).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the
outlet off. A single “beep” will confirm the reception of the command.
9955126_A00_Proflame_Wall_Mount_6 6 24/02/2014 15.42.20

7
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the difference
between the set point temperature and the actual room temperatures. As the room
temperature gets closer to the set point the Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word "SMART" appears to
the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the desidered set
temperature is displayed on the LCD screen of the transmitter (Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be
controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the
Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep”
will confirm reception of the command.
Continous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon
(fig. 17 & 18).
Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode (CPI). Pressing the
Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.
NOTE: this function is available only with Proflame IFC.
NOTE: If the system is equipped with a CPI/IPI toggle switch:
• Set the CPI/IPI switch to CPI position(switch closed) to enable remote CPI/IPI
operation.
• Set the CPI/IPI switch to IPI position (switch open) to disable remote CPI/IPI
operation. The system will now work in IPI mode only regardless of the selection on
the remote control hand set.
Remote auxiliary relay control
The auxiliary function controls the AUX relay outlet. To activate this function use the Mode Key
(fig. 1) to index to the AUX icon (fig. 15 & 16).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the
outlet off. A single “beep” will confirm the reception of the command.
Fig. 15 Fig. 16
Fig. 17 Fig. 18
9955126_A00_Proflame_Wall_Mount_7 7 24/02/2014 15.42.21

8
Remote dimmer control (Light)
The dimmer function controls the Light power outlet by power light control. To activate this
function use the Mode Key (fig. 1) to index to the Light icon (fig. 19 & 20).
The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys
(Fig.1) adjust the output level (fig. 16). A single “beep” will confirm reception of the command.
Note. This function is available only with the Proflame IFC.
Fig. 19 Fig. 20
Split Flow control
The secondary burner is controlled by the split Flow. To activate this function use the Mode Key
(fig. 1) to index to the SPLIT FLOW mode icon (fig. 21 & 22).
Pressing the Up Arrow Key will activate the secondary burner. Pressing the Down Arrow Key
will turn the secondary burner off. A single “beep” will confirm the reception of the command.
Fig. 21 Fig. 22
This function will lock the keys to avoid unsupervised
operation.
To activate this function, press the MODE and UP Keys at
the same time (fig. 23).
To de-activate this function, press the MODE and UP Keys
at the same time.
KEY LOCK
Fig. 23
Transmitter
The life span of the remote control batteries depends on
various factors: quality of the batteries used, the number
of ignitions of the appliance, the number of changes to
the room thermostat set point, etc.
When the transmitter batteries are low, a Battery icon
will appear on the LCD display of the transmitter (Fig. 24)
before all battery power is lost. When the batteries are
replaced this icon will disappear.
LOW BATTERY POWER DETECTION
Fig. 24
9955126_A00_Proflame_Wall_Mount_8 8 24/02/2014 15.42.23

9
Remote dimmer control (Light)
The dimmer function controls the Light power outlet by power light control. To activate this
function use the Mode Key (fig. 1) to index to the Light icon (fig. 19 & 20).
The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys
(Fig.1) adjust the output level (fig. 16). A single “beep” will confirm reception of the command.
Note. This function is available only with the Proflame IFC.
Fig. 19 Fig. 20
Split Flow control
The secondary burner is controlled by the split Flow. To activate this function use the Mode Key
(fig. 1) to index to the SPLIT FLOW mode icon (fig. 21 & 22).
Pressing the Up Arrow Key will activate the secondary burner. Pressing the Down Arrow Key
will turn the secondary burner off. A single “beep” will confirm the reception of the command.
Fig. 21 Fig. 22
This function will lock the keys to avoid unsupervised
operation.
To activate this function, press the MODE and UP Keys at
the same time (fig. 23).
To de-activate this function, press the MODE and UP Keys
at the same time.
KEY LOCK
Fig. 23
Transmitter
The life span of the remote control batteries depends on
various factors: quality of the batteries used, the number
of ignitions of the appliance, the number of changes to
the room thermostat set point, etc.
When the transmitter batteries are low, a Battery icon
will appear on the LCD display of the transmitter (Fig. 24)
before all battery power is lost. When the batteries are
replaced this icon will disappear.
LOW BATTERY POWER DETECTION
Fig. 24
9955126_A00_Proflame_Wall_Mount_9 9 24/02/2014 15.42.25

10
WARNING
Fire Hazard. Can cause severe injury or death
The transmitter causes ignition of the appliance. The appliance can turn on
suddenly. Keep away from the appliance burner when operating the remote system.
FCC CONFORMITY (for 315MHz version only)
The “Proflame Wall Mount transmitter” complies with the following requirements:
- FCC (Federal Communications Commission) Part 15
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Changes or modification not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC ID: T99058404300
DIMENSIONAL DRAWINGS
152
63
63
26
26
Ø3
Ø3
9955126_A00_Proflame_Wall_Mount_10 10 24/02/2014 15.42.25

11
WARNING
Fire Hazard. Can cause severe injury or death
The transmitter causes ignition of the appliance. The appliance can turn on
suddenly. Keep away from the appliance burner when operating the remote system.
Fig. 24: PROFLAME transmitter dimensional drawing
DIMENSIONAL DRAWINGS
Dimensions in millimeters.
152
63
63
26
26
Ø3
Ø3
9955126_A00_Proflame_Wall_Mount_11 11 24/02/2014 15.42.25

SIT La Precisa S.p.A.
Viale dell’Industria 31-33
35129 PADOVA - ITALY
Tel. +39/049/829.31.11, Fax +39/049/807.00.93
9955126_A00_Proflame_Wall_Mount_12 12 24/02/2014 15.42.26
Table of contents
Other SITGroup Control System manuals
Popular Control System manuals by other brands

CSP Pacific
CSP Pacific SENTRY BARRIER Product and installation manual

Carson
Carson Reflex Wheel-X 50 050 0030 instruction manual

zipwake
zipwake E Series installation guide

Precision Engineering
Precision Engineering Bimba PCS user manual

Toshiba
Toshiba TOSDIC-CIE DS Programming manual

Beninca
Beninca VE.650 Operating instructions and spare parts catalogue