Skytech ESTOP1-0H User manual

REV. 4-28-23
Skytech: ESTOP1-0H Gas Timer
Model: ESTOP1-0H
Description The ESTOP1-0H Gas Timer is an emergency shut-off, mechanical timer, and manual shut-off gas valve
designed to be installed on the inlet side of a gas appliance to enable the user to control the time gas is allowed to ow
to a gas appliance. This is a mechanical timer (no batteries or power required) that has the ability to control gas ow for
1-hour (60 minutes). In addition, both models have an emergency shut-off (red knob) that enables the user to quickly and
easily shut the gas completely OFF, should the need arise.
The ESTOP1-0H Gas Timer body is 4-inches high x 2 ⅞-inches wide x 2 ⅛ -inches deep and can replace a manual
shut-off valve and meet local code requirements as the accessible shut-off valve. It can be use for multiple applications
(indoor or outdoor) from gas re pits, gas grills, gas logs, gas torch lights, etc., anywhere a shut-off valve is a required or a
specied by a manufacturer, code requirement or customer.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
E-STOP1-0
PUSH TO STOP
TURN TO START
OFF
0.5
HOURS
1
1.5
2
2.5
E-STOP2-5
TURN
PAST
Specications
Pipe Size: ½” NPT (2) inlets and (2) outlets Maximum Pressure: ½” PSI
CSA Rated Capacity: 165,000 Btu/Hr at 1” Pressure Drop (NG) Ambient Temperature: 0°F to 175°F (79°C)
Timer Accuracy: 60 Min. +/- 15% or 2.5 Hrs.+/- 15% Inlets: Have fine mesh screens to filter any debris
Multiple Mounting Holes: Uses 3/16-24 machine threads Designed For: Natural or LP Gas (no conversion required)
CSA Certified: Tested to ANSI Z21.21; CSA 6.5
WARNING
• Read these instructions carefully. Failure to follow these instructions completely could damage the product or cause
a hazardous condition.
• Check the ratings given in the instructions and on the product your installing to make sure the ESTOP1-0H Gas
Timer is suitable for your application. See description below.
• Installer must be a trained, experienced service technician or gas plumber.
• After installation is complete, check out product operation as provided in these instructions.
CALIFORNIA PROPOSITION 65
WARNING
This product can expose you to Lead, which is
known to the state of California to cause cancer
and birth defects or other reproductive harm.
(For more information, go to www.p65warnings.ca.gov)
E-Stop Gas Timer
U.S. PATENT
10,520,108

Skytech: ESTOP1-0H Gas Timer REV. 4-28-23
4 /”
TYP
2 /”
TYP
C
L
C
L
C
L
C
L
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
PUSH TO STOP
TURN TO START
OFF
TURN
PAST 20
40
60
MINUTES
BACK VIEW
4”
2 /”
2¹/”
³/”
Fig. 1 ESTOP1-0H Gas Timer mounting hole locations applicable to both models.
Mounting
The ESTOP1-0H Gas Timer has the ability to be mounted from the side of the body, using the four (4) provided holes
(two mounting holes per side) or using the two mounting hole tabs at the top and bottom of the body when facing forward.
Each mounting hole uses 3/16 - 24 machine screws to secure it into position. Note: We recommend using stainless steel
screws for any outdoor applications. See Fig. 1 for details.
2.0” Inlet @ 1.0” Outlet =
0.5
1.0
1.5
2.0
2.5
3.0” Inlet @ 1.5” Outlet =
4.0” Inlet @ 2.0” Outlet =
250,000 275,000 300,000 325,000 350,000 375,000 400,000
Btu/Hr
Pressure Drop & Capacity Curve
E-Stop Timer (LP Gas)
5.0” Inlet @ 2.5” Outlet =
3.0
425,000 450,000
Note: Pressure drop information listed is generated in American Flame lab and is to be used as reference only.
Table 2 Pressure drop and capacity for LP Gas).
2.0” Inlet @ 1.0” Outlet =
0.5
1.0
1.5
2.0
2.5
3.0” Inlet @ 1.5” Outlet =
4.0” Inlet @ 2.0” Outlet =
150,000 175,000 200,000 225,000 250,000 275,000 300,000
Btu/H
Pressure Drop & Capacity Curve
E-Stop Timer (Natural Gas)
Table 1 Pressure drop and capacity for Natural Gas.

REV. 4-28-23
Skytech: ESTOP1-0H Gas Timer
Installation
The ESTOP1-0H is designed to be installed in an up-right
position as shown in Fig 3, view "D" or Fig. 4. It has two
(2) inlet and two (2) outlet gas connections. The diagrams
below provide possible ways to plumb the timer (See Fig. 3).
Two (2) ½” NPT plugs are provided with the timer. Plug the
inlet and outlet connections not being used for the
application. Connect gas supply to the inlet with the
arrow pointing into the valve. Connect outlet side to the
gas appliance (See Figs. 2 & 3 for details).
NOTE: Conduct a gas leak test on the ESTOP1-0H Gas
Timer after plumbing is complete.
Operation
TO TURN ON
Step 1: Rotate the clear timer dial past 20 (ESTOP1-0H)
to set the time. Timer will begin “ticking” when the dial is
turned while the countdown time is set.
Step 2: Turn red knob clockwise (about a ¼ turn) until it
pops outward. Gas will now ow to enable you to light the
appliance.
TO TURN OFF: Let timer expire or simply press red knob
inward until it stops. The red knob will lock down with a
“click” and stop gas ow. See Fig. 4 and Fig. 5 on following
page.
CAUTION: Do not force the timer dial to the OFF position
after time is set. This will weaken the spring inside the timer
body and can affect the accuracy of the time. If it is
necessary to shut the timer OFF simply press the red knob
inward to stop operation. The timer will turn itself OFF
when the time expires.
Timer Dial:
Rotate clockwise to
start time. Adjust dial to
desired time frame.
Red Knob: Turn
clockwise and knob
will “pop” up to allow
gas flow.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Fig. 4 ESTOP1-0H operation.
BACK VIEW
Inlet
Inlet
Outlet
Outlet
SIDE IN SIDE OUT
BACK
IN
BACK
OUT
Fig. 2 Inlet and outlet connections.
“A-C”Shows Top View of ESTOP1-0H
“D” Shows Front View of ESTOP1-0H
Inlet
Outlet
D
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Inlet
Outlet
C
Inlet
Outlet
B
Inlet
Outlet
A
Fig. 3 Plumbing options

Skytech: ESTOP1-0H Gas Timer REV. 4-28-23
FOR TECHNICAL U.S. INQUIRIES CANADIAN INQUIRIES
SERVICE: (855) 498-8324 or (260) 459-1703 (877) 472-3923
Sales: (888) 672-8929
Sales Support: (888) 699-6167
Website: www.skytechpg.com
Limited Warranty
The ESTOP1-0H Gas Timer is warrantied for 12 months from the date of purchase or installation to the original purchaser to be
free from defects in materials and workmanship. It is designed for INDOOR OR OUTDOOR USE. Damage to the ESTOP1-0H Gas
Timer caused by accident, misuse, abuse, or installation error, whether per formed by a contractor, Service Company, or owner, is
not covered by this warranty. American Flame will not be responsible for labor charges and/or damage incurred in installation, repair,
replacement, or for incidental or consequential damage. Some states, provinces, and nations do not allow exclusion or limitations
of incidental or consequential damages, so the above limitations or exclusions may not apply. This warranty gives you specic legal
rights. You may also have other rights that vary by state, province, or nation.
Skytech Products Group
9230 Conservation Way
Fort Wayne, IN 46809
(260) 459-1703
Symptom Remedy
No gas ow 1. Rotate dial beyond the "turn past" position.
2. Ensure red knob is protruding outward in ON position.
3. Has time has expired on timer? If so re-start timer again.
4. Ensure primary gas supply is turned ON.
5. Ensure the gas timer is plumbed properly.
6. Look for any physical damage.
7. Ensure other gas valves before or after the timer are operating.
8. Check inlet mesh screen for debris blockage.
Gas ow won't stop 1. Timer plumbed backwards? Check inlets and outlets on timer.
2. Excessive gas pressure exceeding the ½” PSI maximum pressure.
3. Plumbed into both inlet lines and not one of the outlets.
4. Look for any physical damage. If so, replace timer.
Fig. 5 ESTOP1-0H Gas Timer red knob positions
TROUBLESHOOTING
Red Knob In = Gas OFF
Red Knob Out = Gas ON
Side View
Side View