STAIRCASE LIGHTING TIMERy ASH-01 INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
VER. 002_01.12.2008
FEATURES
DESCRIPTION
APPEARANCE
ی Staircase lighting control,
ی operating time adjustment from 10
sec to 10 min,
ی cooperation with monostable push-
buttons equipped with illumination
lamps,
ی cooperation with 3-wire or 4-wire in-
stallation,
ی cable connection 0,5 m long,
ی hermetic casing (IP 65),
ی voltage relay output max 16 A capa-
city.
The staircase lighting time delay
switch ASH-01 is used to control lighting
devices on staircases and corridors. After
releasing the system it switches on the
lighting for the preset time by the user.
After that it switches off automatically.
The operating time can be adjusted from
10 sec to 10 min by means of a potentio-
meter. The staircase lighting time delay
switch ASH-01 can be used as standard
time delay relay. The hermetic casing
(IP65) secures the device functioning in
unfavorable weather conditions.
The device is designed
for single-phase instal-
lation and must be in-
stalled in accordance
with standards valid in
a particular country. The
device should be con-
nected according to the details included
in this operating manual. Installation,
connection and control should be car-
ried out by a qualied electrician staff,
who act in accordance with the servi-
ce manual and the device functions.
Disassembling of the device is equal
with a loss of guarantee and can cause
electric shock. Before installation make
sure the connection cables are not un-
der voltage. The cruciform head screw-
driver 3,5 mm should be used to instal
the device. Improper transport, stora-
ge, and use of the device inuence its
wrong functioning. It is not advisable to
instal the device in the following cases:
if any device part is missing or the de-
vice is damaged or deformed. In case
of improper functioning of the device
contact the producer.
CAUTION
TECHNICAL PARAMETERS
ASH-01
Power supply cables: L (black), N (blue)
Input rated voltage: 230 V~
Input voltage tolerance: from -15 to +10 %
Nominal frequency: 50 / 60 Hz
Rated power consumption: 48 mA
Release / output (load) cables:
brown, grey (connected inside)
Time adjustment range: from 10 sec to 10 min
Time accuracy adjustment: ±10 %
Time repeatability adjustment: ±5 %
Time adjustment: rotational potentiometer
Output relay parameters: 16 A / 250 V AC1 4000 VA
Number of switch cables: 4
Section of connecting cables: 4 x 1,50 mm2
Connecting cable length: 0,5 m
Ambient temperature range: from -20 to +45 oC
Operating position: vertical, pointed down
Mounting: 2x stretcher 5x(3x30)
Protection degree: IP65 (PN-EN 60529)
Protective class: II
Overvoltage category: II
Pollution degree: 2
Rated impulse withstand voltage: 1 kV (PN-EN 61000-4-5)
Dimensions: 69 x 56 x 27 mm
Weight: 101 g
Reference standards: PN-EN 60669-1
PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
b
l
a
c
k
b
r
o
w
n
g
r
e
y
b
l
u
e
Power supply cable (N)
Power supply cable (L)
Time adjustment
Release / output (load)
cables
VER. 002_01.12.2008
INNER DIAGRAM
CONNECTINGMOUNTING
FUNCTIONING
EXAMPLE OF INSTALLATION
After proper mounting and installation
the device is ready to work. Releasing the
system with the monostable pushbutton
causes the lighting to switch on for the
preset time. After the preset time is over
the lighting is automatically switched off till
its another release. The staircase lighting
time delay switch cooperates with 3-wire or
4-wire system. While mounting the device
pay attention the release and load systems
are properly connected, otherwise the de-
vice can be irreparably damaged. Because
of no anti-blocking system the light is con-
stantly switched on in cases the pushbut-
ton is blocked.
1. Disconnect the power supply from the
mains by the phase fuse, the circuitbre-
aker or the switch-disconnector that are
joined to the proper circuit.
2. Check if there is no voltage on con-
nection cables by means of a special
measure equipment.
3. Fasten the ASH-01 to the base with the
screw.
NOTICE! It is forbidden to bore tting
holes in the cover! It may result in the
loss of containment of the cover and
by this – the loss of guarantee!
4. Connect the cables ASH-01 with the her-
metic installation junction box according
to installing diagram.
5. Switch on the power supply from the ma-
ins.
6. Take out the rubber hole plug covering
the adjustment of the switch on threshold
potentiometer.
7. Adjust the demanded switch on time by
means of a potentiometer.
8. Put back the rubber hole plug covering
the potentiometer.
DIMENSIONS TIME COURSE PRODUCT FAMILY
Typical application:
The staircase lighting time delay switch ASH-01 operating the staircase lighting
works in 3-wire installation. Monostable pushbutton (equipped with illumination) can
be connected parallely.
RELAY CAPACITY
The ASH-01 is a member of the ASx
staircase timer family.
blackblue
grey
brown
t
t t t
t
3 wire system 4 wire system
b
l
a
c
k
b
l
a
c
k
b
l
u
e
b
l
u
e
g
r
e
y
g
r
e
y
b
r
o
w
n
b
r
o
w
n
b
l
a
c
k
b
l
u
e
g
r
e
y
b
r
o
w
n
Device symbol
Type of casing:
M – monomodular
N – surface mounting
H – hermetical
P – for junction box mounting
Device version:
01 – three - or four-conductor
wiring
02 – anti-lock system
10 – dimmer function
Version 24 V AC/DC
for ASM-02 available

This manual suits for next models

1

Other Zamel Timer manuals

Zamel EXTA ASM-02 User manual

Zamel

Zamel EXTA ASM-02 User manual

Zamel exta ZCM-32 User manual

Zamel

Zamel exta ZCM-32 User manual

Zamel EXTA ASM-03 User manual

Zamel

Zamel EXTA ASM-03 User manual

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Zamel EXTA ASP-01 User manual

Zamel

Zamel EXTA ASP-01 User manual

Zamel ASM-04 User manual

Zamel

Zamel ASM-04 User manual

Zamel EXTA ASN-02 User manual

Zamel

Zamel EXTA ASN-02 User manual

Zamel exta ASP - 10 User manual

Zamel

Zamel exta ASP - 10 User manual

Zamel EXTA ASH-01 User manual

Zamel

Zamel EXTA ASH-01 User manual

Zamel exta ZCM-12 User manual

Zamel

Zamel exta ZCM-12 User manual

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Popular Timer manuals by other brands

Orbit 94066 Installation and user guide

Orbit

Orbit 94066 Installation and user guide

Kärcher WT 5 Original instructions

Kärcher

Kärcher WT 5 Original instructions

Eaton TRL04 Technical data

Eaton

Eaton TRL04 Technical data

Perel E305DO quick start guide

Perel

Perel E305DO quick start guide

Altox Timer-2 operating manual

Altox

Altox Timer-2 operating manual

Siemens 1. B. S. T. operating instructions

Siemens

Siemens 1. B. S. T. operating instructions

koban KPHD-WIFI-ASTRO quick start guide

koban

koban KPHD-WIFI-ASTRO quick start guide

Traceable 5004 operating instructions

Traceable

Traceable 5004 operating instructions

Autonics LE7M-2 manual

Autonics

Autonics LE7M-2 manual

Prince Castle 741-T2HW Series operating instructions

Prince Castle

Prince Castle 741-T2HW Series operating instructions

pass & seymour rt12 installation instructions

pass & seymour

pass & seymour rt12 installation instructions

MULTISPAN MDT-4310 operating manual

MULTISPAN

MULTISPAN MDT-4310 operating manual

Oregon Scientific PMP238 user manual

Oregon Scientific

Oregon Scientific PMP238 user manual

UltraPro 45184 user manual

UltraPro

UltraPro 45184 user manual

Web Mountain Technologies TIM-01 user guide

Web Mountain Technologies

Web Mountain Technologies TIM-01 user guide

Toshiba TCB-EXS21TLE instruction manual

Toshiba

Toshiba TCB-EXS21TLE instruction manual

Melnor Aqua Timer 3015 manual

Melnor

Melnor Aqua Timer 3015 manual

Prince Castle 740-T44 Specifications

Prince Castle

Prince Castle 740-T44 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.