manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sloan
  6. •
  7. Toilet
  8. •
  9. Sloan WES-1000 User manual

Sloan WES-1000 User manual

OR LESS TRIM
13 ¾" ¼ "
13 ½ ½
13 ¼ ¾
13 1
12 ¾ 1¼
12 ½ 1½
12 ¼ 1¾
12 2
11 ¾ 2¼
11 ½ 2½
11 ¼ 2¾
11 3
10 ¾ 3 ¼
10 ½ 3 ½
OR LESS TRIM
10 ¼" 3 ¾"
10 4
9 ¾ 4 ¼
9 ½ 4 ½
9 ¼ 4 ¾
9 5
8 ¾" 5 ¼
8 ½ 5 ½
8 ¼ 5 ¾
8 6
7 ¾ 6 ¼
7 ½ 6 ½
7 ¼ 6 ¾
7 7
OR LESS TRIM
6 ¾" 7 ¼"
6 ½ 7 ½
6 ¼ 7 ¾
6 8
5 ¾ 8 ¼
5 ½ 8 ½
5 ¼ 8 ¾
5 9
4 ¾ 9 ¼
4 ½ 9 ½
4 ¼ 9 ¾
4 10
1-888-SLOAN-14 (888-756-2614)
customer.servic[email protected]m
CUSTOMER SERVICE
INCORRECT
Not centered
CORRECT
Centered
A
½" to ¾"
9¾"
for ADA
installation
standard 24" rim
finished floor
16 ¾"
Drain
2½
6
⁄
½
21½
Install plastic anchor
and screw here
Install additional
screws here
11 10
12
1234
Arrow
tab UP
1234
A
C
BDE
CARTRIDGE
INSTRUCTIONS
The information in this document is subject to change without notice.
©2014 Sloan Valve Company All rights reserved.
0816483 Rev. 4 (03-14)
sloanvalve.com
CAUTION After removing any urinal from the
drainline, it’s normal for certain naturally occurring
but potentially hazardous sewer gases to escape
through the opening until the waterless cartridge
is installed properly into the waterless urinal. If you
need to leave an open drain line unattended after
removing the urinal from the wall, temporarily wedge paper towels or a
rag into the drainhole to reduce any outflow of sewer gases, and remove
the paper towels or rag prior to completing the urinal or cartridge
installation. Never smoke, have an open flame, or place your nose or
mouth near open drain lines or waterless urinal housings into which
a cartridge is not yet properly installed. You alsocan wear abreathing
mask when removing or installing any waterless urinal or cartridge to
reduce potential exposure to any such gases.
B
B
15 16
4
14
7
3
13
9
6
2
11 1210
8
5
1
C D
WES-1000 WATERFREE URINAL
NEW CONSTRUCTION
INSTALLATION INSTRUCTIONS
BEFORE STARTING INSTALLATION:
IMPORTANT - Do not install on copper DWV
due to copper’s susceptibility to corrosion.
Check rough-in height to achieve 24” rim height
(17” rim height for ADA).
Check slope. Downhill slope, per code, is
essential because of waterfree urinals depend
on gravity flow.
Check DWV material. Suitable materials include
cast iron, PVC, ABS, and galvanized steel.
Shut o water supply and cap the nipple with
the 3/4” chrome cap (provided).
•
•
.
•
TUBE CUTTING CHART
•
•
•
Measure drain nipple depth (in) to find trim
length (in)
13 7/8” or more DO NOT CUT
3 3/4” or less DO NOT USE TUBE
•
SET DRAIN HEIGHT 16 3/4” from finished floor
(standard 24” rim) or 9 3/4” for ADA installation.
Threaded nipple should extend 1/2 to 3/4” from
wall.
CARRIER STUD PLACEMENT If using in-wall
carrier, set bearing as shown above.
13
21
A. Clean face of existing wall flange.
B. Install the brass flange with the clean
inspection disc.
C. Slowly pour water into the drain.
D. Use a flashlight to check the pitch/slope.
There should be no water present in the
inspection disc or nipple.
E. Remove flange after inspection.
ADJUST DRAIN TO ACHIEVE PITCH If standing
water is present (code requires 1/4” drop per
foot of drain line for proper pitch). Seal wall
according to code.
MEASURE & MARK THE ROUGH-IN If in-wall
carrier is not used. Use a 5/16” masonry bit to
drill hole, then install the hanger bracket with
one plastic anchor and screw.
LEVEL THE BRACKET THEN MARK, drill and
install two additional plastic anchors and screws.
If pre-existing bearing rods can be used, screws
are not necessary.
A. Hang the bowl on the bracket and check tall
pipe alignment, then remove the bowl and
adjust the bracket as needed.
Re-hang and re-check bowl alignment with
drain line. Tail pipe should align with center or
drain line.
B. Mark anchor holes then remove
bowl without moving hanger
bracket.
DETERMINE THE DRAIN NIPPLE DEPTH by
measuring the distance between the back of the
sanitary tee (or elbow) to the front edge of the
nipple.
A. Find the drain nipple depth on the Tube
Cutting Chart (left).
Measure and mark the specified trim length on
the insert tube at the nearest 1/4” groove.
B. Cut the tube at the groove using a sharp
utility knife to ensure a square, flat cut.
C. Clean burrs from the cut end by using emery
paper.
D. Apply lubricant to the outside of the rubber
brushing and ribbed inside area.
E. Insert the tube and brushing with arrow tab at
the top. Apply lubricant to tailpipe of housing.
PLACE THE GEAR CLAMP
and compression nut onto
the housing tailpipe.
DRILL HOLES with 5/16”
masonry bit for the lower
anchor screws and insert
plastic anchors.
HANG THE BOWL inserting
tailpipe into brushing, then install
anchor screws with washers.
TIGHTEN FLANGE BOLTS.
TIGHTEN
COMPRESSION
NUT AND GEAR
CLAMP.
POUR 5
GALLONS OF
WATER as
rapidly as
possible into
housing to
ensure good
flow and no
leaks or
standing water. CAULK THE BOWL TO
THE WALL.
INSTALL THE
CARTRIDGE per the
cartridge instruction
sheet.
2" side cutter blade
Cut away wall
Lift drain line & brace
with mending plate
Install additional
screws here
INCORRECT
Not centered
CORRECT
Centered
11 10
12
CARTRIDGE
INSTRUCTIONS
1234
Arrow
tab UP
1234
A
C
BDE
"
21½
Install plastic anchor
and screw here
15 16
4
14
7
3
13
9
6
2
11 1210
8
5
1
B
C D
A B
OR LESS TRIM
13 ¾" ¼ "
13 ½ ½
13 ¼ ¾
13 1
12 ¾ 1¼
12 ½ 1½
12 ¼ 1¾
12 2
11 ¾ 2¼
11 ½ 2½
11 ¼ 2¾
11 3
10 ¾ 3 ¼
10 ½ 3 ½
OR LESS TRIM
10 ¼" 3 ¾"
10 4
9 ¾ 4 ¼
9 ½ 4 ½
9 ¼ 4 ¾
9 5
8 ¾" 5 ¼
8 ½ 5 ½
8 ¼ 5 ¾
8 6
7 ¾ 6 ¼
7 ½ 6 ½
7 ¼ 6 ¾
7 7
OR LESS TRIM
6 ¾" 7 ¼
6 ½ 7 ½
6 ¼ 7 ¾
6 8
5 ¾ 8 ¼
5 ½ 8 ½
5 ¼ 8 ¾
5 9
4 ¾ 9 ¼
4 ½ 9 ½
4 ¼ 9 ¾
4 10
1-888-SLOAN-14 (888-756-2614)
customer.servic[email protected]m
CUSTOMER SERVICE
The information in this document is subject to change without notice.
©2014 Sloan Valve Company All rights reserved.
0816483 Rev. 4 (03-14)
sloanvalve.com
CAUTION After removing any urinal from the
drainline, it’s normal for certain naturally occurring
but potentially hazardous sewer gases to escape
through the opening until the waterless cartridge
is installed properly into the waterless urinal. If you
need to leave an open drain line unattended after
removing the urinal from the wall, temporarily wedge paper towels or a
rag into the drainhole to reduce any outflow of sewer gases, and remove
the paper towels or rag prior to completing the urinal or cartridge
installation. Never smoke, have an open flame, or place your nose or
mouth near open drain lines or waterless urinal housings into which
a cartridge is not yet properly installed. You alsocan wear abreathing
mask when removing or installing any waterless urinal or cartridge to
reduce potential exposure to any such gases.
WES-1000 WATERFREE URINAL
RETRO-FIT
INSTALLATION INSTRUCTIONS
BEFORE STARTING INSTALLATION:
IMPORTANT - Do not install on copper DWV
due to copper’s susceptibility to corrosion.
Check rough-in height to achieve 24” rim height
(17” rim height for ADA).
Check slope. Downhill slope, per code, is
essential because of waterfree urinals depend
on gravity flow.
Check DWV material. Suitable materials include
cast iron, PVC, ABS, and galvanized steel.
Shut o water supply and cap the nipple with
the 3/4” chrome cap (provided).
•
•
.
•
TUBE CUTTING CHART
•
•
•
Measure drain nipple depth (in) to find trim
length (in)
13 7/8” or more DO NOT CUT
3 3/4” or less DO NOT USE TUBE
•
PLACE THE SEAL INTO THE
FLANGE with the ribs facing
out. Install the flange with
washers and hex nuts, but do
not tighten completely.
DRILL HOLES with
5/16” masonry bit for
the lower anchor
screws and insert
plastic anchors.
INSTALL THE GEAR
CLAMP with screw
head at bottom,
but do not tighten .
POUR 5
GALLONS OF
WATER as
rapidly as
possible into
housing to
ensure good
flow and no
leaks or
standing water. CAULK THE BOWL TO
THE WALL.
INSTALL THE
CARTRIDGE per the
cartridge instruction
sheet.
HANG THE BOWL inserting
tailpipe into brushing, then install
anchor screws with washers.
TIGHTEN FLANGE BOLTS.
A. Find the drain nipple depth on the Tube
Cutting Chart (left).
Measure and mark the specified trim length on
the insert tube at the nearest 1/4” groove.
B. Cut the tube at the groove using a sharp
utility knife to ensure a square, flat cut.
C. Clean burrs from the cut end by using emery
paper.
D. Apply lubricant to the outside of the rubber
brushing and ribbed inside area.
E. Insert the tube and brushing with arrow tab at
the top. Apply lubricant to tailpipe of housing.
MEASURE & MARK THE ROUGH-IN If in-wall
carrier is not used. Use a 5/16” masonry bit to
drill hole, then install the hanger bracket with
one plastic anchor and screw.
LEVEL THE BRACKET THEN MARK, drill and
install two additional plastic anchors and screws.
If pre-existing bearing rods can be used, screws
are not necessary.
A. Hang the bowl on the bracket and check tall
pipe alignment, then remove the bowl and
adjust the bracket as needed.
Re-hang and re-check bowl alignment with
drain line. Tail pipe should align with center or
drain line.
B. Mark anchor holes then remove
bowl without moving hanger
bracket.
DETERMINE THE DRAIN NIPPLE DEPTH by
measuring the distance between the back of the
sanitary tee (or elbow) to the front edge of the
nipple.
A. Clean face of existing wall flange.
B. Install the brass flange with the clean
inspection disc.
C. Slowly pour water into the drain.
D. Use a flashlight to check the pitch/slope.
There should be no water present in the
inspection disc or nipple.
E. Remove flange after inspection.
ADJUST DRAIN TO ACHIEVE PITCH If standing
water is present (code requires 1/4” drop per
foot of drain line for proper pitch). Seal wall
according to code.
USE UTILITY KNIFE TO CUT CAULK then use a
putty knife and mallet to remove the bowl.
Remove hanger brackets, scrape o caulk, and
clean the wall.
IMPORTANT: Use a drain machine to remove
build-up inside pipes. Clean up to 25 feet deep
then finish with water to remove cutting debris.

Popular Toilet manuals by other brands

agape 750 ACER0750WRRS Assembly instructions

agape

agape 750 ACER0750WRRS Assembly instructions

American Standard Ultima VorMax 203AA.104 owner's manual

American Standard

American Standard Ultima VorMax 203AA.104 owner's manual

Kallista P70080-00 installation guide

Kallista

Kallista P70080-00 installation guide

Grohe Eurocube 39736000 installation instructions

Grohe

Grohe Eurocube 39736000 installation instructions

Dometic VacuFlush 4800 Series Quick start instructions

Dometic

Dometic VacuFlush 4800 Series Quick start instructions

Kohler K-3639 Installation and care guide

Kohler

Kohler K-3639 Installation and care guide

OVE E323 installation manual

OVE

OVE E323 installation manual

Gessi 39113 manual

Gessi

Gessi 39113 manual

Ideal-Standard Alto Toilet Seat installation guide

Ideal-Standard

Ideal-Standard Alto Toilet Seat installation guide

Roca MULTICLEAN PREMIUM A80400800 manual

Roca

Roca MULTICLEAN PREMIUM A80400800 manual

Thornthwaite A50154 installation manual

Thornthwaite

Thornthwaite A50154 installation manual

DURAVIT SensoWash i Lite 620000 01 1 40 1310 Mounting instructions

DURAVIT

DURAVIT SensoWash i Lite 620000 01 1 40 1310 Mounting instructions

IFO Cera 3875 Maintenance Instruction

IFO

IFO Cera 3875 Maintenance Instruction

Toto WASHLET+ NEXUS 1G S550E MW4423056CUFGA 01... installation instructions

Toto

Toto WASHLET+ NEXUS 1G S550E MW4423056CUFGA 01... installation instructions

Arcisan Neion Plus instruction manual

Arcisan

Arcisan Neion Plus instruction manual

Kohler VEIL K-1381T-S installation instructions

Kohler

Kohler VEIL K-1381T-S installation instructions

BEMIS bioBidet HD-7000 owner's manual

BEMIS

BEMIS bioBidet HD-7000 owner's manual

VITRA V-Care Prime 7231B403-6216 user manual

VITRA

VITRA V-Care Prime 7231B403-6216 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions