SMART Embedded Computing AXP1440-C07 Quick start guide

AXP1440-C07
Installation and Use
P/N: 6806800V18A
February 2020

© 2020 SMART Embedded Computing™, Inc.
All Rights Reserved.
Trademarks
The stylized "S" and "SMART" is a registered trademark of SMART Modular Technologies, Inc. and “SMART Embedded
Computing” and the SMART Embedded Computing logo are trademarks of SMART Modular Technologies, Inc. All other names
and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. These materials are
provided by SMART Embedded Computing as a service to its customers and may be used for informational purposes only.
Disclaimer*
SMART Embedded Computing (SMART EC) assumes no responsibility for errors or omissions in these materials. These
materials are provided "AS IS" without warranty of any kind, either expressed or implied, including but not limited to,
the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. SMART EC further does
not warrant the accuracy or completeness of the information, text, graphics, links or other items contained within these
materials. SMART EC shall not be liable for any special, indirect, incidental, or consequential damages, including without
limitation, lost revenues or lost profits, which may result from the use of these materials. SMART EC may make changes to
these materials, or to the products described therein, at any time without notice. SMART EC makes no commitment to update
the information contained within these materials.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a
URL to a SMART EC website. The text itself may not be published commercially in print or electronic form, edited, translated,
or otherwise altered without the permission of SMART EC.
It is possible that this publication may contain reference to or information about SMART EC products, programming, or services
that are not available in your country. Such references or information must not be construed to mean that SMART EC intends
to announce such SMART EC products, programming, or services in your country.
Limited and Restricted Rights Legend
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply
unless otherwise agreed to in writing by SMART Embedded Computing.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in
Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and
Documentation clause at DFARS 252.227-7014 (Jun. 1995).
SMART Embedded Computing, Inc.
2900 S. Diablo Way, Suite 190
Tempe, Arizona 85282
USA
*For full legal terms and conditions, visit www.smartembedded.com/ec/legal

Table of Contents
AXP1440-C07 Installation and Use (68068000V18A) 1
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Safety Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Notice de Sécurité. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
1 Platform Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
1.1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
1.2 PICMG Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1.3 Shelf Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1.4 Network Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
1.4.1 Base Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
1.4.2 Fabric Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
1.4.3 IPMI Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1.4.4 Update Channel Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
1.5 Backplane and Component Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
1.6 Remote Management and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2 AXP1440-C07 Shelf Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.2 Platform Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2.3 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
2.4 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
2.5 Shelf Ground Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
2.6 Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
2.6.1 Functional Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
2.6.2 E-Keying. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
2.6.3 Shelf FRU Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
2.6.4 Backplane Slot Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
2.6.5 Zone Locations on a Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
2.7 IEEE802.3ap/IEEE802.3ba . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2.8 Fan Tray Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2.9 Alarm Display Panel (ADP1440-D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

2 AXP1440-C07 Installation and Use (68068000V18A)
Table of Contents
2.10 Power Entry Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
2.11 Stationary Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
2.12 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
2.13 Ordering and Support Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.2 Site Planning Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.2.1 Receiving and Unpacking the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.2.2 Site and Installation Planning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
3.2.3 Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
3.2.3.1 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
3.2.3.2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
3.3 Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
3.3.1 Mounting Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
3.3.2 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
3.3.3 Cooling Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
3.3.4 Acoustic Noise Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
3.4 Site Planning Checklists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
4 AXP1440-C07 Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.2 Recommended Power On Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.3 Recommended Power Off Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.4 Emergency Power Off Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.5 Power Entry Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.5.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.5.2 IPMC Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
4.6 Fan Tray Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
4.6.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
4.6.2 Cooling Budget. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
4.6.3 IPMC Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
4.7 Air Filter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
4.7.1 Storing the Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

Table of Contents
AXP1440-C07 Installation and Use (68068000V18A) 3
5 AXP1440-C07 Shelf Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5.2 Shelf Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5.3 Installation Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5.3.1 Equipment Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5.3.2 Cable Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.3.3 Rack/Cabinet Cooling Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.3.4 Airflow Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
5.3.5 Mounting Options and Stabilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
5.3.6 Weight Distribution Within a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
5.3.7 Electrostatic Discharge (ESD) and Safety Procedures . . . . . . . . . . . . . . . . . . . . . . 99
5.4 Installing the Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
5.4.1 19" EIA Rack/Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
5.4.1.1 Procedure - Install the Shelf in a Rack or Cabinet . . . . . . . . . . . . . . . . . 100
5.5 Grounding the Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
5.6 Shelf Ground Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
5.7 DC Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
5.8 Power Cable Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
5.9 Connecting the Cables to the PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
5.9.0.1 Procedure - Connect Cables to PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
5.10 Powering Up the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
5.10.0.1 Procedure - Power Up the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
5.11 Accessing the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
5.12 Upgrading Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
5.12.1 Fan Tray IPMC Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
5.12.1.1 Procedure - Upgrade Fan Tray Firmware . . . . . . . . . . . . . . . . . . . . . . . 106
5.12.1.2 Fan Tray Upgrade Sample Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
5.12.2 PEM IPMC Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
5.12.2.1 Procedure - Upgrade the PEM Firmware . . . . . . . . . . . . . . . . . . . . . . . . 108
5.12.2.2 PEM Upgrade Sample Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
5.12.3 Shelf Manager Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
5.12.3.1 Procedure - Upgrade the Shelf Manager . . . . . . . . . . . . . . . . . . . . . . . . 110
5.12.3.2 Procedure - Establish Network Connectivity to SAM1620-D . . . . . . . . . 111
5.12.3.3 Procedure - Update Firmware on SAM1620-D . . . . . . . . . . . . . . . . . . . 111
6 FRU Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
6.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

4 AXP1440-C07 Installation and Use (68068000V18A)
Table of Contents
6.2 RTM-ATCA-F140-D Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
6.2.1 Procedure - RTM with Installed Front Switch Blade. . . . . . . . . . . . . . . . . . . . . . . . 114
6.2.2 Procedure - Remove an RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
6.3 Node Blade Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
6.3.1 Procedure - Install the Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
6.3.2 Procedure - Remove the Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
6.4 Shelf Management Module Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
6.4.1 Procedure - Install a SAM1620-D in Nonpowered or Powered Shelf. . . . . . . . . . . 127
6.4.2 Procedure - Remove a SAM1620-D from Nonpowered or Powered Shelf . . . . . . 129
6.5 Power Entry Module Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
6.5.1 Tools You Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
6.5.2 Procedure - Remove a PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
6.5.3 Procedure - Install a PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
6.6 Fan Tray Module Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
6.6.1 Reposition the Alarm Display Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
6.6.2 Procedure - Remove the Upper Fan Tray Module . . . . . . . . . . . . . . . . . . . . . . . . . 135
6.6.3 Procedure - Install the Upper Fan Tray Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
6.6.4 Procedure - Remove the Lower Fan Tray Module . . . . . . . . . . . . . . . . . . . . . . . . . 136
6.6.5 Procedure - Install the Lower Fan Tray Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
6.7 Replacing the Fan Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
6.7.1 Procedure - Replace a Fan Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
7 Shelf Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
7.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
7.2 SAM1620-D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
7.3 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
7.3.1 IPMB Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
7.3.2 RS-232 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
7.3.3 Master-Only I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
7.3.4 Shelf FRU SEEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
7.3.5 SAM1620-D and Alarm Display Panel Face Plates . . . . . . . . . . . . . . . . . . . . . . . . 143
7.3.5.1 SAM1620-D/ADP1440-D Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 144
7.3.5.2 Hot Swap LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
7.4 Management and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
7.4.1 Hardware Monitoring and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
7.4.1.1 Voltage Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
7.4.1.2 Temperature Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
7.4.1.3 Fan Speed and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Table of Contents
AXP1440-C07 Installation and Use (68068000V18A) 5
7.4.2 Redundancy Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
7.4.2.1 Hardware Redundancy Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
7.4.2.2 HRI Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
7.4.2.3 Ethernet Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
7.4.2.4 Configuring Front Panel Network Interface . . . . . . . . . . . . . . . . . . . . . . 152
7.4.2.5 Configuring the RMCP Network Interface . . . . . . . . . . . . . . . . . . . . . . . 152
7.4.3 Switchover Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
7.5 Alarm Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.5.1 Cutoff Push Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.5.2 Alarm LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.5.3 Alarm Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.6 Hot Swap Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
7.7 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
7.8 SAM1620-D Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
7.8.1 imls Utility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
A Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
A.1 SMART Embedded Computing Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
A.2 Related Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

6 AXP1440-C07 Installation and Use (68068000V18A)
Table of Contents

List of Figures
AXP1440-C07 Installation and Use (68068000V18A) 7
Figure 1-1 Top-Bottom-Back Plates View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Figure 1-2 Long Captive Screws-Rear of Shelf through Backplane . . . . . . . . . . . . . . . . . . . . 53
Figure 1-3 Captive Screws to Lock ATCA-F140-D Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 1-4 Long Captive Screw Protruding from the RTM-ATCA-F140-D . . . . . . . . . . . . . . . 55
Figure 1-5 Attachment Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 1-6 Locking Upper Fan Tray UFT1440-D using Internal Captive Screw . . . . . . . . . . . 56
Figure 1-7 Locking SAM1620-D using Internal Captive Screws . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 1-8 Update Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 1-9 Location of Zones 1, 2, and 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 2-1 Front Shelf View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 2-2 Rear Shelf View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 2-3 Backplane Power Segments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 2-4 Base and Fabric Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 2-5 Lower Fan Tray Module, LFT1440-D, Front View . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 2-6 Upper Front, UFT1440-D, Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 2-7 PEM Backplane Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 2-8 PEM View with Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 3-1 Planning Checklist 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Figure 3-2 Planning Checklist 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 5-1 Rack Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Figure 5-2 Shelf Airflow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Figure 5-3 Jonathon Company Rail System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 5-4 Placement of Grounding Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Figure 5-5 DC Power Connection Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Figure 6-1 SAM1620-D Shelf Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Figure 6-2 ADP1440-D Mounting Screws (Front of Shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Figure 6-3 Internal Locking Screw Location (Front of Shelf) . . . . . . . . . . . . . . . . . . . . . . . . 134
Figure 6-4 Lower Front Ejector Handles and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Figure 7-1 Block Diagram of SAM1620-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Figure 7-2 SAM1620-D Face Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Figure 7-3 ADP1440-D Face Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Figure 7-4 SAM1620-D HRI Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Figure 7-5 Interhub Slot and Shelf Manager Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . 151

List of Figures
8 AXP1440-C07 Installation and Use (68068000V18A)

List of Tables
AXP1440-C07 Installation and Use (68068000V18A) 9
Table 2-1 DC Shelf Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 2-2 Slot Connector Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 2-3 Backplane Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 2-4 Slot Hardware Addressing for J10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 2-5 Fan Tray Module Hardware Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 2-6 SAM and PEM Hardware Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 2-7 LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 2-8 LED Status for the ADP1440-D Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 2-9 PEM LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Table 2-10 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Table 3-1 Environmental Requirements for the AXP1440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Table 3-2 Critical Temperature Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 3-3 System Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 3-4 Dimensions and Weight of Shelf and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Table 4-1 PEM IPMB Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Table 4-2 Cooling Budget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 5-1 AXP1440-C07 14-Slot Shelf Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 5-2 Power and Ground Wire Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Table 7-1 RJ-45 Serial Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Table 7-2 Alarm Display Panel (ADP1440-D) Serial Port Connector . . . . . . . . . . . . . . . . . . . . 142
Table 7-3 SAM LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Table 7-4 ADP1440-D LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 7-5 ADP1440-D and SAM1620-D LED Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 7-6 Hot Swap LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 7-7 Cooling Budget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Table 7-8 Fan Speeds for all Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Table 7-9 Shelf Manager Static Network IP Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Table 7-10 Shelf Manager Dynamic Network IP Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Table 7-11 Hot Swap Interface Pin Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
Table A-1 SMART EC Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Table A-2 Related Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

List of Tables
10 AXP1440-C07 Installation and Use (68068000V18A)

AXP1440-C07 Installation and Use (6806800V18A) 11
About this Manual
Overview of Contents
This guide is intended for users qualified in electronics or electrical engineering. Users must
have a working understanding of Peripheral Component Interconnect (PCI),
AdvancedTCA®, and telecommunications.
This manual is divided into the following chapters and appendices:
About this Manual lists all conventions and abbreviations used in this manual and outlines
the revision history.
Safety Notes on page 17 describes the safety information applicable to the use of this
product.
Noticede Sécurité onpage27 provides the European French translation of the safety notes
section.
Sicherheitshinweise on page 39 provides the German translation of the safety notes
section.
Chapter 1, Platform Architecture on page 51 describes the system architecture.
Chapter 2, AXP1440-C07 Shelf Description on page 63 provides an overview of the
features of the system and lists the standard compliances.
Chapter 3, Site Preparation on page 79 provides site planning considerations and
checklists, describes the requirements and conditions.
Chapter 4, AXP1440-C07 Operations on page 89 describes basic operating procedures.
Chapter 5,AXP1440-C07 Shelf Installation on page 95 describes mounting and installation
options.
Chapter 6, FRU Installation on page 113 describes how to install and replace blades,
modules, power components, fans, and air filter.
Chapter7, Shelf Management Module on page 139 describes the shelf management alarm
module.
Appendix A, Related Documentation on page 159 lists related documentation and
specifications.

12 AXP1440-C07 Installation and Use (6806800V18A)
About this Manua
l
About this Manual
Abbreviations
This document uses the following abbreviations.
Abbreviation Definition
AdvancedTCA Advanced Telecommunications Computing Architecture
ADP Alarm Display Panel
ATCA Advanced Telecommunications Computing Architecture
AWG American Wire Gauge
BIOS Basic Input Output System
CISPR Comité International Spécial des Perturbations Radioélectriques
CLI Command Line Interface
CMOS Complimentary Metal-oxide-semiconductor
CPU Central Processing Unit
CPLD Complex Programmable Logic Device
DDR Double Data Rate
DTE Data Terminal Equipment
ECC Error Correcting Code
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
EMV Elektromagnetische Vertraeglichkeit
ESD Electrostatic Discharge
FCC Federal Communications Comission
FPGA Field Programmable Gate Array
FRU Field Replaceable Unit
FTM Fan Tray Module
GPIO General Purpose Input Output

About this Manual
AXP1440-C07 Installation and Use (6806800V18A) 13
HPI Hardware Platform Interface
HS Hot Swap
ID Identifier
IEC International Electric Code
IEEE Institute of Electrical and Electronics Engineers
IPMB Intelligent Platform Management Bus
IPMC Intelligent Platform Management Controller
IPMI Intelligent Platform Management Interface
IS In Service
JTAG Joint Test Access Group
LED Light-emitting Diode
LFT Lower Fan Tray
MMU Memory Management Unit
NEC National Electric Code
OEM Original Equipment Manufacturer
OOS Out of Service
OS Operating System
PCI Peripheral Component Interconnect
PCB Printed Circuit Board
PEM Power Entry Module
PICMG PCI Industrial Computer Manufacturers Group
PLD Programmable Logic Device
RISC Reduced Instruction Set Computer
RMCP Remote Management Control Protocol
Abbreviation Definition

14 AXP1440-C07 Installation and Use (6806800V18A)
About this Manua
l
About this Manual
RoHS Restriction of Certain Hazardous Substances
RTC Real Time Clock
RTM Rear Transition Module
SDR Sensor Data Record
SDRAM Synchronous Dynamic Random Access Memory
SEEPROM Serial EEPROM
SELV Safety Extra Low Voltage
ShM Shelf Manager
ShMC Shelf Management Controller
ShMM Shelf Management Mezzanine Module
SNMP Simple Network Management Protocol
SOC System on Chip
SPI Serial Peripheral Interface
STP Shielded Twisted Pair
TCP Transmission Control Protocol
TNV-2 Telecom Network Voltages without overvoltage
TPE Twisted-pair Ethernet
UFT Upper Fan Tray
UL Underwriters Laboratories
VCCI Voluntary Control Council for Interference
Abbreviation Definition

About this Manual
AXP1440-C07 Installation and Use (6806800V18A) 15
Conventions
The following table describes the conventions used throughout this manual.
Notation Description
0x00000000 Typical notation for hexadecimal numbers (digits are 0 through F), for example
used for addresses and offsets
0b0000 Same for binary numbers (digits are 0 and 1)
bold Used to emphasize a word
Screen Used for on-screen output and code related elements or commands in body text
Courier +
Bold Used to characterize user input and to separate it from system output
Reference Used for references and for table and figure descriptions
File > Exit Notation for selecting a submenu
<text> Notation for variables and keys
[text] Notation for software buttons to click on the screen and parameter description
... Repeated item for example node 1, node 2, ..., node 12
.
.
.
Omission of information from example/command that is not necessary at the time
being
.. Ranges, for example: 0..4 means one of the integers 0,1,2,3, and 4 (used in
registers)
| Logical OR
Indicates a hazardous situation which, if not avoided, could result in death or
serious injury
Indicates a hazardous situation which, if not avoided, may result in minor or
moderate injury

16 AXP1440-C07 Installation and Use (6806800V18A)
About this Manua
l
About this Manual
Summary of Changes
This manual has been revised and replaces all prior editions.
Indicates a property damage message
Indicates a hot surface that could result in moderate or serious injury
Indicates an electrical situation that could result in moderate injury or death
Indicates that when working in an ESD environment care should be taken to use
proper ESD practices
No danger encountered. Pay attention to important information.
Notation Description
Part Number Publication Date Description
6806800V18A February 2020 Initial Release.

AXP1440-C07 Installation and Use (6806800V18A) 17
Safety Notes
This section provides warnings that precede potentially dangerous procedures throughout
this manual. Instructions contained in the warnings must be followed during all phases of
operation, service, and repair of this equipment. You should also employ all other safety
precautions necessary for the operation of the equipment in your operating environment.
Failure to comply with these precautions or with specific warnings elsewhere in this manual
could result in personal injury or damage to the equipment.
SMART Embedded Computing intends to provide all necessary information to install and
handle the product in this manual. Because of the complexity of this product and its various
uses, we do not guarantee that the given information is complete. If you need additional
information, ask your SMART EC representative.
The product has been designed to meet the standard industrial safety requirements. It must
not be used in safety critical components, life supporting devices, or on aircraft.
Only personnel trained by SMART EC or persons qualified in electronics or electrical
engineering are authorized to install, remove, or maintain the product. The information
given in this manual is meant to complete the knowledge of a specialist and must not be
used as replacement for qualified personnel.
Keep away from live circuits inside the equipment. Operating personnel must not remove
equipment covers. Only factory authorized service personnel or other qualified service
personnel may remove equipment covers for internal subassembly or component
replacement or any internal adjustment.
Do not install substitute parts or perform any unauthorized modification of the equipment or
the warranty may be voided. Contact your local SMART EC representative for service and
repair to make sure that all safety features are maintained.
General
Personal Injury
Be careful when handling the system. There are sharp pins on the back of the system which
can cause injury.
EMC
The product has been tested and found to comply with the limits for a Class A digital device
in this system, pursuant to part 15 of the FCC Rules, EN 55032 Class A respectively.
These limits are designed to provide reasonable protection against harmful interference
when the product is operated in a commercial, business or industrial environment.

18 AXP1440-C07 Installation and Use (6806800V18A)
Safety Notes
Safety Notes
The product conducts, radiates and uses radio frequency energy and, if not installed
properly and used in accordance with this user documentation, may cause harmful
interference to radio communications.
Changes or modifications not expressly approved by SMART EC could void the user's
regulatory compliance. Board products are tested in a representative system to show
compliance with the above mentioned requirements. A proper installation in a compliant
system will maintain the required performance.
Use only shielded cables when connecting peripherals to help assure that appropriate radio
frequency emissions compliance is maintained. For proper EMC shielding, only operate the
system with face plates installed and all vacant slots covered or populated with filler cards.
An AXP1440 that is shipped as a spare, replacement chassis, or an unconfigured system
will not have filler panels installed. It is the responsibility of the customer to ensure that all
open slots are filled with payload blades, rear transition modules (RTMs), or approved filler
panels in order to be compliant with the safety/EMC regulatory markings.
This is a Class A product based on the standard of the Voluntary Control Council for
Interference (VCCI) by Information Technology Interference. If this equipment is used in a
domestic environment, radio disturbance may arise. When such trouble occurs, the user
may be required to take corrective actions.
The equipment is suitable for installation in a Common Bonding Network (CBN) or Isolated
Bonding Network (IBN).
Grounding
If the product is not properly grounded, it may be damaged by electrostatic discharge.
The system contains EMI gaskets at the shelf and module level. Make sure that each of the
system's parts contact the EMI gasket.
The shelf is also fitted with an ESD jack/snap for use with conductive wrist straps. Make
sure the operator uses proper ESD protection.
System Installation
System Damage
To avoid system damage verify that the system environment meets the environmental and
power requirements given in this manual before installing the system. Before you set up
and cable your new system, consider these guidelines:
Restricted access location: Intended for installation in a restricted access location
with access by trained personnel only.
This manual suits for next models
1
Table of contents
Popular Indoor Furnishing manuals by other brands

YOTRIO
YOTRIO MS10-301-002-01 Assembly instruction

Unfinished Furniture of Wilmington
Unfinished Furniture of Wilmington S-132 Assembly instructions

Argos Home
Argos Home Gloss Single Wall Cabinet Grey 363/3704 Assembly instructions

adairs
adairs ORLANDO Assembly instructions

The Land of Nod
The Land of Nod Home Library Bookcase Assembly instructions

Mocka
Mocka Sadie Assembly instructions