Dual Smoke / Heat Detector
Installation Guide
Part number Product description
SC-21-0200-0001-99 Dual Smoke / Heat Detector
1 Pre installation 2 Components
!Installation must conform to applicable local installation codes and
should only be installed by a fully trained competent person.
This device contains electronics that may be susceptible to damage
from Electrostatic Discharge (ESD). Take appropriate precautions
when handling electronic boards.
The use of a non-metallic spacer should be considered if mounting
the device on to a metal surface.
Dust cover Mounting plate
12 3
Dual smoke / heat detector
Batteries (not included in some regions*)
4
5 Fit batteries
When fitting / replacing batteries, observe correct polarity, using only
specified batteries.
6 Configuration
ER14500AA
ER14500AA
+
-
+
-
ER14500AA+
-
The device must now be added (programmed) to the control panel.
Device powering
Method 1
Magnet application
Method 2
Via computer
Method 3
4 Fix mounting plate
When fixing to the ceiling, all four fixing positions should be used to
ensure a firm fixing.
Use suitable fasteners and
fixings. 60 mm
60 mm
Where existing electrical
mounting boxes are present,
two fixing positions may be
used.
3 Remove mounting plate
Remove the mounting plate by turning the device ANTICLOCKWISE, to
release it from the mounting plate.
OBSERVE BATTERY
POLARITY!
!
3x ER14505M
LITHIUM 3.6V
©2021 EMS Ltd. All rights reserved. Page 1 of 2 TSD086-0001-99 (Issue 3) 25/08/2021 AJM
*When batteries are not supplied, only fit specified batteries.
3
124
To ensure correct operation, products must be used within the
specified environmental operating conditions.
Refer to the programming manual
for full programming details.
SmartCell panel = TSD155
SmartCell WZM = MK067
0017A3
(A)
(B)
Operating temperature -10 to +55 °C
Storage temperature
With batteries -10 to +30 °C
Without batteries -10 to +55 °C
Humidity 0 to 95% noncondensing
Location Type A: for indoor use
Supply 3 x ER14505M 3.6 V lithium thionyl chloride
batteries (Fanso & Titus)
CAUTION!
Operating voltage 2.7 to 3.65 VDC
Operating frequency 868 MHz
Output transmitter power 14 dBm / 25 mW
Signalling protocol X5
Detector sensitivity and Smoke: Normal*†, Normal+AVF,
responsivity settings Heat: 58 °c static (A2S)*†, 58 °c rate of rise
(A2R)*, 72 °c static (BS)* & 72 °c rate of rise (BR)*
* EN54 approved sensitivities †Default dual sensitivities
Dimensions (Ø x D) 110 x 58 mm
Specification
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul. Kolejowa 24.
39-100 Ropczyce, Poland
Year of manufacture See devices serial number label
Certification
Certification body
CPR DoP 0359-CPR-00265
Approved to
EN54-5:2001. Incorporating amendment no. 1. Fire
detection and fire alarm systems. Part 5: heat detectors
- point detectors.
EN54-7:2001. Incorporating amendment no. 1. Fire
detection and fire alarm systems. Part 7: smoke
detectors - point detectors using scattered light,
transmitted light or ionization.
EN54-13:2005. Fire detection and fire alarm systems.
Part 13: compatibility assessment of system
components.
EN54-25:2008. Incorporating corrigenda september
2010 and march 2012. Fire detection and fire alarm
systems. Part 25: components using radio links.
European Union
EMS declares that the radio equipment type SmartCell
directives
Dual Smoke / Heat Detector is in compliance with
Directive 2014/53/EU. The full text of the EU declaration
of conformity is available at the following internet
address: www.mysmartcell.com
2012/19/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly manner according to your local regulations.
19
0905
9 Device unlocking
Remove dust cover before use.
The device should be tested upon installation and in accordance with local
requirements.
Testing should only be carried out by a fully trained competent person.
The manufacturer recommends regular functional testing in accordance with
local codes of practice.
Cleaning and repairs must be undertaken by the manufacturer’s authorised
representative.
Do not open the case to clean inside the detector.
IMPORTANT
!
9
8 Completing the installation
Reassemble the device as shown below.
7 Optional device locking
Regulatory information
The device includes an optional locking mechanism.
Remove the thin section of plastic shown below.
Once locked, the Allen key will be required
to unlock the device.
If the device has been locked, an
Allen key will be required for
unlocking.
Depress the locking mechanism,
by inserting the Allen key, or
similar, into the device’s cavity
and pushing (A).
Simultaneously twist the device
anti-clockwise to release (B).
This is a life safety product. Only use manufacturer approved battery types.
Failure to do so may result in damage to the product.
DO NOT mix batteries of different type or age.
When replacing batteries; remove all old batteries before fitting replacements.
©2021 EMS Ltd. All rights reserved. Page 2 of 2 TSD086-0001-99 (Issue 3) 25/08/2021 AJM

Other SmartCell Smoke Alarm manuals

SmartCell SC-23-0220-0001-99 User manual

SmartCell

SmartCell SC-23-0220-0001-99 User manual

SmartCell SC-22-0200-0001-99 User manual

SmartCell

SmartCell SC-22-0200-0001-99 User manual

SmartCell SC-22-0200-0001-99 User manual

SmartCell

SmartCell SC-22-0200-0001-99 User manual

SmartCell SC-23-0210-0001-99 User manual

SmartCell

SmartCell SC-23-0210-0001-99 User manual

Popular Smoke Alarm manuals by other brands

B-Link FUME instructions

B-Link

B-Link FUME instructions

Kidde AirSense Stratos Micra 25 Installer's handbook

Kidde

Kidde AirSense Stratos Micra 25 Installer's handbook

Vitek VT-SMKC1 manual

Vitek

Vitek VT-SMKC1 manual

GST C-9403 Quick start quide

GST

GST C-9403 Quick start quide

Lexing LX-SO-918 Instruction

Lexing

Lexing LX-SO-918 Instruction

System Sensor OSI-RE-SS quick start guide

System Sensor

System Sensor OSI-RE-SS quick start guide

LEGRAND tynetec ZXT810 quick start guide

LEGRAND

LEGRAND tynetec ZXT810 quick start guide

Dometic FA25 Installation and operating manual

Dometic

Dometic FA25 Installation and operating manual

BRK electronic SA340B quick start guide

BRK electronic

BRK electronic SA340B quick start guide

First Alert 3120B user manual

First Alert

First Alert 3120B user manual

BRK electronic 7030BSL quick start guide

BRK electronic

BRK electronic 7030BSL quick start guide

Jalo Helsinki Kupu manual

Jalo Helsinki

Jalo Helsinki Kupu manual

PSA LIFESAVER 5800RF quick start guide

PSA

PSA LIFESAVER 5800RF quick start guide

Dorma RMZ manual

Dorma

Dorma RMZ manual

Trader Bear BESMOKEY4 Installation and user manual

Trader

Trader Bear BESMOKEY4 Installation and user manual

Halma Ampac TITANUS PRO-SENS Technical manual

Halma

Halma Ampac TITANUS PRO-SENS Technical manual

GE ADTGC-HDVM Installation sheet

GE

GE ADTGC-HDVM Installation sheet

ADEMCO 4192 installation instructions

ADEMCO

ADEMCO 4192 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.