Dual Smoke / Heat Detector and
Combined Sounder Beacon
Installation Guide
Part number Product description
SC-23-0210-0001-99
SC-23-0220-0001-99
Dual Smoke / Heat Detector and Combined
Sounder-Beacon (VAD RED Flash)
Dual Smoke / Heat Detector and Combined
Sounder-Beacon (VAD WHITE Flash)
1Pre installation 2 Components
Dust cover
12Dual smoke / heat detector and combined sounder beacon
3
12
!Installation must conform to applicable local installation codes and
should only be installed by a fully trained competent person.
This device contains electronics that may be susceptible to damage
from Electrostatic Discharge (ESD). Take appropriate precautions
when handling electronic boards.
The use of a non-metallic spacer should be considered if mounting
the device on to a metal surface.
4
5 Fit batteries
When fitting / replacing batteries, observe correct polarity, using only
specified batteries.
6 Configuration
ER14500AA
ER14500AA
+
-
+
-
ER14500AA+
-
Refer to the programming manual
for full programming details.
The device must now be added (programmed) to the control panel.
Device powering
Method 1
Magnet application
Method 2
Via computer
Method 3
4 Fix mounting plate
When fixing to the ceiling, all four fixing positions should be used to
ensure a firm fixing.
Use suitable fasteners and
fixings. 60 mm
60 mm
Where existing electrical
mounting boxes are present,
two fixing positions may be
used.
3 Remove mounting plate
Remove the mounting plate by turning the device ANTICLOCKWISE, to
release it from the mounting plate.
OBSERVE BATTERY
POLARITY!
!
3x ER14505M
LITHIUM 3.6V
©2021 EMS Ltd. All rights reserved. Page 1 of 2 TSD091-0001-99 (Issue 4) 25/08/2021 AJM
Mounting plate
3Batteries (not included in some regions*)
4
*When batteries are not supplied, only fit specified batteries.
To ensure correct operation, products must be used within the
specified environmental operating conditions.
SmartCell panel = TSD155
SmartCell WZM = MK067
0017A3
Device unlocking
If the device has been locked, an
Allen key will be required for
unlocking.
Depress the locking mechanism,
by inserting the Allen key, or
similar, into the device’s cavity
and pushing (A).
Simultaneously twist the device
anti-clockwise to release (B).
IMPORTANT
(A)
!
Remove dust cover before use.
The device should be tested upon installation and in accordance with local
requirements.
Testing should only be carried out by a fully trained competent person.
The manufacturer recommends regular functional testing in accordance with
local codes of practice.
Cleaning and repairs must be undertaken by the manufacturer’s authorised
representative.
Do not open the case to clean inside the detector.
7 Optional device locking
(B)
Reassemble the device as shown below.
9
8 Completing the installation
Operating temperature -10 to +55 °C
Storage temperature
With batteries -10 to +30 °C
Without batteries -10 to +55 °C
Humidity 0 to 95% noncondensing
Location / IP rating Type A: for indoor use / IP33
Supply 3 x ER14505M 3.6 V lithium thionyl chloride
batteries (Fanso or Titus)
CAUTION!
Operating voltage 2.7 to 3.65 VDC
Current consumption 0.32 A max.
Power consumption 0.8 W max.
Operating frequency 868 MHz
Output transmitter power 14 dBm / 25 mW
Signalling protocol X5
Detector sensitivity and Smoke: Normal*†, Normal+AVF,
responsivity settings Heat: 58°c static (A2S)*†, 58c rate of rise (A2R)*,
72°c static (BS)* & 72°c rate of rise (BR)*
* EN54 approved sensitivities †Default dual sensitivities
Sounder output 93 dB(A) at 1m max.
For full sounder output information, refer to the Sounder Data doc (MK103).
Beacon coverage C-3-12 (WHITE flash) / C-3-9.5 (RED flash)
Beacon flash rate 0.5 Hz (1 flash, every 2 seconds)
Dimensions (Ø x D) 110 x 61 mm
Specification
Certification
Certification body
CPR DoP
0905
19
EN54-3:2001. Incorporating amendments nos. 1 and 2. Fire
detection and fire alarm systems. Part 3: fire alarm devices -
sounders.
EN54-5:2001. Incorporating amendment no. 1. Fire detection
and fire alarm systems. Part 5: heat detectors - point
detectors.
EN54-7:2001. Incorporating amendment no. 1. Fire detection
and fire alarm systems. Part 7: smoke detectors - point
detectors using scattered light, transmitted light or ionization.
EN54-13:2005. Fire detection and fire alarm systems.
Part 13: compatibility assessment of system components.
EN54-23:2010. Fire detection and fire alarm systems.
Part 23: fire alarm devices. Visual alarm devices.
EN54-25:2008. Incorporating corrigenda September 2010 and
march 2012. Fire detection and fire alarm systems. Part 25:
components using radio links.
EMS declares that the radio equipment type SmartCell Dual
Detector With Combined Sounder Beacon is in compliance
with Directive 2014/53/EU. The full text of the EU declaration
of conformity is available at the following internet address:
www.mysmartcell.com
2012/19/EC (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this
product to your local supplier upon purchase of equivalent
new equipment, or dispose of it at designated collection
points. For more information see www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
European Union
directives
Approved to
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul. Kolejowa 24.
39-100 Ropczyce, Poland
Year of manufacture See devices serial number label
0359-CPR-00268
Regulatory information
The device includes an optional locking mechanism.
Remove the thin section of plastic shown below.
Once locked, the Allen key will be required
to unlock the device.
SD091-0001-99 (Issue 4) 25/08/2021 AJM ©2021 EMS Ltd. All rights reserved. Page 2 of 2 TSD091-0001-99 (Issue 4) 25/08/2021 AJM
This is a life safety product. Only use manufacturer approved battery types.
Failure to do so may result in damage to the product.
DO NOT mix batteries of different type or age.
When replacing batteries; remove all old batteries before fitting replacements.

This manual suits for next models

1

Other SmartCell Smoke Alarm manuals

SmartCell SC-21-0200-0001-99 User manual

SmartCell

SmartCell SC-21-0200-0001-99 User manual

SmartCell SC-22-0200-0001-99 User manual

SmartCell

SmartCell SC-22-0200-0001-99 User manual

SmartCell SC-22-0200-0001-99 User manual

SmartCell

SmartCell SC-22-0200-0001-99 User manual

SmartCell SC-23-0210-0001-99 User manual

SmartCell

SmartCell SC-23-0210-0001-99 User manual

Popular Smoke Alarm manuals by other brands

Honeywell Fire-Lite Alarms BEAM355A Installation and maintenance instructions

Honeywell

Honeywell Fire-Lite Alarms BEAM355A Installation and maintenance instructions

Bellman & Symfon BE1480 user manual

Bellman & Symfon

Bellman & Symfon BE1480 user manual

Bentel Security 601PH manual

Bentel Security

Bentel Security 601PH manual

CPVan SM11R Quick reference guide

CPVan

CPVan SM11R Quick reference guide

Abus HSRM20000 / RM40 Li user manual

Abus

Abus HSRM20000 / RM40 Li user manual

Fire-Lite FACP instruction sheet

Fire-Lite

Fire-Lite FACP instruction sheet

Online Power Fire Alarm Back-up UPS1481 UNIT user manual

Online Power

Online Power Fire Alarm Back-up UPS1481 UNIT user manual

Ceasefire INTELLI-SENSE TI-002212 installation manual

Ceasefire

Ceasefire INTELLI-SENSE TI-002212 installation manual

Universal Security Instruments MDS300CN quick start guide

Universal Security Instruments

Universal Security Instruments MDS300CN quick start guide

PSA Homeguard HG2000 Installation and user manual

PSA

PSA Homeguard HG2000 Installation and user manual

BRK electronic 9120LBLA Specification sheet

BRK electronic

BRK electronic 9120LBLA Specification sheet

Ei Electronics Heat Alarm Ei 103R Technical specifications

Ei Electronics

Ei Electronics Heat Alarm Ei 103R Technical specifications

AirSense ModuLaser installation manual

AirSense

AirSense ModuLaser installation manual

BRK electronic SA350B quick start guide

BRK electronic

BRK electronic SA350B quick start guide

Emos P56501-GS536 quick start guide

Emos

Emos P56501-GS536 quick start guide

Polon-Alfa POLON 4000 Series Operation and maintenance

Polon-Alfa

Polon-Alfa POLON 4000 Series Operation and maintenance

Tyco IR6003/7 Product user guide

Tyco

Tyco IR6003/7 Product user guide

ADEMCO 4192CP Installation and Maintenance

ADEMCO

ADEMCO 4192CP Installation and Maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.