SmartCell SC-22-0200-0001-99 User manual

Dual Smoke / Heat Detector and
Combined Sounder
Installation Guide
Part number Product description
SC-22-0200-0001-99 Dual Smoke / Heat Detector and
Combined Sounder
1 Pre installation 2 Components
Mounting plate
3
Dust cover
12Dual smoke / heat detector and combined sounder
!Installation must conform to applicable local installation codes and
should only be installed by a fully trained competent person.
This device contains electronics that may be susceptible to damage
from Electrostatic Discharge (ESD). Take appropriate precautions
when handling electronic boards.
The use of a non-metallic spacer should be considered if mounting
the device on to a metal surface.
Batteries (not included in some regions*)
4
5 Fit batteries
When fitting / replacing batteries, observe correct polarity, using only
specified batteries.
6 Configuration
ER14500AA
ER14500AA
+
-
+
-
ER14500AA+
-
The device must now be added (programmed) to the control panel.
Device powering
Method 1
Magnet application
Method 2
Via computer
Method 3
4 Fix mounting plate
When fixing to the ceiling, all four fixing positions should be used to
ensure a firm fixing.
Use suitable fasteners and
fixings. 60 mm
60 mm
Where existing electrical
mounting boxes are present,
two fixing positions may be
used.
3 Remove mounting plate
Remove the mounting plate by turning the device ANTICLOCKWISE, to
release it from the mounting plate.
OBSERVE BATTERY
POLARITY!
!
3x ER14505M
LITHIUM 3.6V
©2021 EMS Ltd. All rights reserved. Page 1 of 2 TSD090-0001-99 (Issue 3) 25/08/2021 AJM
3
124
*When batteries are not supplied, only fit specified batteries.
To ensure correct operation, products must be used within the
specified environmental operating conditions.
Refer to the programming manual
for full programming details.
SmartCell panel = TSD155
SmartCell WZM = MK067
0017A3
(A)
(B)
Device unlocking IMPORTANT
9
8 Completing the installation
Reassemble the device as shown below.
!
Remove dust cover before use.
The device should be tested upon installation and in accordance with local
requirements.
Testing should only be carried out by a fully trained competent person.
The manufacturer recommends regular functional testing in accordance with
local codes of practice.
Cleaning and repairs must be undertaken by the manufacturer’s authorised
representative.
Do not open the case to clean inside the detector.
7 Optional device locking
Operating temperature -10 to +55 °C
Storage temperature
With batteries -10 to +30 °C
Without batteries -10 to +55 °C
Humidity 0 to 95% noncondensing
Location Type A: for indoor use
IP rating IP21C
Supply 3 x ER14505M 3.6 V lithium thionyl chloride
batteries (Fanso or Titus)
CAUTION!
Operating voltage 2.7 to 3.65 VDC
Current consumption 0.15 A max.
Power consumption 0.38 W max.
Operating frequency 868 MHz
Output transmitter power 14 dBm / 25 mW
Signalling protocol X5
Detector sensitivity and Smoke: Normal*†, Normal+AVF,
responsivity settings Heat: 58°c static (A2S)*†, 58c rate of rise (A2R)*,
72°c static (BS)* & 72°c rate of rise (BR)*
* EN54 approved sensitivities † Default dual sensitivities
Sounder output 89 dB(A) at 1 m max.
For full sounder output information, refer to the Sounder Data doc (MK103).
Dimensions (Ø x D) 110 x 58 mm
Specification
Certification
Certification body
CPR DoP
0905
19
EN54-3:2001. Incorporating amendments nos. 1 and 2. Fire
detection and fire alarm systems. Part 3: fire alarm devices -
sounders.
EN54-5:2001. Incorporating Amendment No. 1. Fire detection
and fire alarm systems. Part 5: heat detectors - point
detectors.
EN54-7:2001. Incorporating amendment no. 1. Fire detection
and fire alarm systems. Part 7: smoke detectors - point
detectors using scattered light, transmitted light or ionization.
EN54-13:2005. Fire detection and fire alarm systems.
Part 13: compatibility assessment of system components.
EN54-25:2008. Incorporating corrigenda september 2010 and
march 2012. Fire detection and fire alarm systems. Part 25:
components using radio links.
EMS declares that the radio equipment type SmartCell Dual
Detector With Combined Sounder is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
www.mysmartcell.com
2012/19/EC (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon purchase of equivalent new
equipment, or dispose of it at designated collection points.
For more information see www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
European Union
directives
Approved to
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul. Kolejowa 24.
39-100 Ropczyce, Poland
Year of manufacture See devices serial number label
0359-CPR-00268
Regulatory information
The device includes an optional locking mechanism.
Remove the thin section of plastic shown below.
Once locked, the Allen key will be required
to unlock the device.
If the device has been locked, an
Allen key will be required for
unlocking.
Depress the locking mechanism,
by inserting the Allen key, or
similar, into the device’s cavity
and pushing (A).
Simultaneously twist the device
anti-clockwise to release (B).
©2021 EMS Ltd. All rights reserved. Page 2 of 2 TSD090-0001-99 (Issue 3) 25/08/2021 AJM
This is a life safety product. Only use manufacturer approved battery types.
Failure to do so may result in damage to the product.
DO NOT mix batteries of different type or age.
When replacing batteries; remove all old batteries before fitting replacements.

Other SmartCell Smoke Alarm manuals

SmartCell SC-22-0200-0001-99 User manual

SmartCell

SmartCell SC-22-0200-0001-99 User manual

SmartCell SC-23-0220-0001-99 User manual

SmartCell

SmartCell SC-23-0220-0001-99 User manual

SmartCell SC-21-0200-0001-99 User manual

SmartCell

SmartCell SC-21-0200-0001-99 User manual

SmartCell SC-23-0210-0001-99 User manual

SmartCell

SmartCell SC-23-0210-0001-99 User manual

Popular Smoke Alarm manuals by other brands

Firehawk FHB10 manual

Firehawk

Firehawk FHB10 manual

LEGRAND 0333-CPD-292050 instructions

LEGRAND

LEGRAND 0333-CPD-292050 instructions

First Alert PR700A Specification sheet

First Alert

First Alert PR700A Specification sheet

Flamingo FA23 user manual

Flamingo

Flamingo FA23 user manual

DAITEM SH151AX 3 installation manual

DAITEM

DAITEM SH151AX 3 installation manual

Bentel Security RF-501t quick start guide

Bentel Security

Bentel Security RF-501t quick start guide

Potter PAD100-6DB quick start guide

Potter

Potter PAD100-6DB quick start guide

Google Nest Protect user guide

Google

Google Nest Protect user guide

Maple Armor FW511 Installation guides

Maple Armor

Maple Armor FW511 Installation guides

Xtralis VESDA-E VES-A10-P Product guide

Xtralis

Xtralis VESDA-E VES-A10-P Product guide

jablotron JA-63ST quick start guide

jablotron

jablotron JA-63ST quick start guide

Lexing LX928-D quick start guide

Lexing

Lexing LX928-D quick start guide

Edwards LaserSense HSSD-2 Installer's handbook

Edwards

Edwards LaserSense HSSD-2 Installer's handbook

System Sensor 1451 Installation and maintenance instructions

System Sensor

System Sensor 1451 Installation and maintenance instructions

Bentel Security FireClass FC400P manual

Bentel Security

Bentel Security FireClass FC400P manual

Matelec FPC-30048 Owner's operation manual

Matelec

Matelec FPC-30048 Owner's operation manual

Ei Electronics Ei3100RF? Ei3500RF Instruction leaflet

Ei Electronics

Ei Electronics Ei3100RF? Ei3500RF Instruction leaflet

System Sensor Innovair DH100LP quick start guide

System Sensor

System Sensor Innovair DH100LP quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.