Snap-On ControlTech User manual

SAFETY INSTRUCTIONS
1 IMPORTANT SAFETY INSTRUCTIONS
35 IMPORTANTES INSTRUCTIONS DE SECURITE
36 INSTRUCCIONES DE SEGURIDAD IMPORTANTES
37 WICHTIGE SICHERHEITSHINWEISE
38 ISTRUZIONI CAUTELARI IMPORTANTI
39 BELANGRIJKE VEILIGHEIDSINSTRUCTIES
40 INSTRUÇÕES DE SEGURANÇA IMPORTANTES
ControlTech®
WIRELESS
TORQUE-ANGLE
SCREWDRIVER
20-2109-SO REV. A
21-11

1
IMPORTANT SAFETY INSTRUCTIONS
WARNING Risk of flying particles.
Over-torquing can cause breakage. An out of calibration screwdriver can cause
part or tool breakage. Broken hand tools, sockets or accessories can cause injury.
Excess force can cause crowfoot or flare nut screwdriver slippage.
Read this manual completely before using ELECTRONIC SCREWDRIVER.
To ensure accuracy, work must not move in angle mode.
For personal safety, and to avoid screwdriver damage, follow good
professional tool and fastener installation practices.
Periodic recalibration is necessary to maintain accuracy.
Wear safety goggles, user and bystanders.
Be sure all components, including all adaptors, extensions, drivers and sockets
are rated to match or exceed torque being applied.
Observe all equipment, system and manufacturer's warnings, cautions and
procedures when using this screwdriver.
Use correct size socket for fastener.
Do not use sockets showing wear or cracks.
Replace fasteners with rounded corners.
To avoid damaging screwdriver: Never use screwdriver with power off. Always
turn ON screwdriver so applied torque is being measured.
Do not press POWER while torque is applied or while screwdriver is in
motion.
Never use this screwdriver to break fasteners loose.
Check that screwdriver capacity matches or exceeds each application before
proceeding.
Verify calibration if dropped.
Verify calibration of screwdriver if you know or suspect its capacity has been
exceeded.
Always adjust your stance to prevent a possible fall should something give
while using screwdriver.
Do not attempt to recharge alkaline cells.
Store screwdriver in dry place.
Remove batteries when storing screwdriver for periods longer than 3 months.
WARNING Electrical Shock Hazard.
Electrical shock can cause injury. Metal in handle is not insulated.
Do not use on live electrical circuits.
SAVE THESE INSTRUCTIONS
Disclaimer
Operation of ControlTechTM Wireless Screwdriver is not warranted in an EU
member state if operating instructions are not in that State’s language. Contact
Snap-on if a translation is needed.

2
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d'en compromettre le fonctionnement.

3
Specifications
Drive Type
¼” Hex Female
¼” Square Male
Display
DISPLAY TYPE: Dot Matrix LCD (168 x 48 Resolution)
VIEWING ANGLE: 6:00
BACKLIGHT: WHITE (LED)
Sealed Button Pad
POWER - ON/OFF and torque and angle re-zero
ENTER - measurement mode select and menu entry
UP –increments torque and angle settings and menu navigation
DOWN - decrements torque and angle settings and menu navigation
UNITS - units select (ft-lb, in-lb, in-oz, Nm, Kg-cm, cNm) and enter PSET (preset) menu
LCD BACKLIGHT –Illuminates all screens and last peak torque or angle recall
Functions
Set - torque or angle target
Track - real time display of torque or accumulated angular rotation with progress lights
Peak Hold –5 sec. flashing of peak torque or alternating peak torque/angle on release of
torque
Peak Recall - display last peak torque or peak torque/angle on button press
Memory - display of last 50 peak torque or peak torque/angle readings
Accuracy
Temperature: @ 22 C (72°F)
Angle: ±1% of reading ±1° @ angular velocity > 10°/sec < 180°/sec: ±2° @ ≤ 90°, ±3° @ > 90° and ≤ 180°
CW CCW
Torque: ±2% ±3% of reading, 20% to 100% of full scale
±4% ±6% of reading, 5% to 19% of full scale
Operating Temperature: 0°F - 130°F (-18°C to 54°C)
Storage Temperature: 0°F to 130°F (-18°C to 54°C)
Measurement Drift: ANGLE: -0.12 Angular Degrees per Degree C
TORQUE: +0.01% of reading per Degree C
Humidity: Up to 90% non-condensing
Battery: Single "AA" Alkaline Cell, up to 20 hours continuous operation.
Lithium or rechargeable NiMH batteries may be used (exceeds ASME
battery life requirement of 10 hours continuous operation).
Default Auto Shut-off: After 2 minutes idle –(Adjustable, see Advanced Settings).
Static Dissipative (ESD) Properties: Surface Resistivity 107- 1010

4
User Instructions
Basic Functions (Quick Start)
Figure 1
Install fresh Alkaline “AA” cell into handle of screwdriver.
Screwdriver Power On Sequence
Note: Do not turn on power to screwdriver while torque is applied, otherwise torque zero offset will be
incorrect and screwdriver will indicate a torque reading when torque is released. If this occurs,
re-zero screwdriver by momentarily pressing POWER button while screwdriver is on a stable
surface with no torque applied.
1. Turn On Screwdriver.
While holding screwdriver still, momentarily press POWER button. Snap-on logo will be
displayed followed by torque and angle re-zeroing screens (if angle mode has been
previously selected). The target TORQUE or ANGLE screen will now be displayed depending
on previous measurement mode selected.
Note: By simultaneously pressing the ENTER and UNITS buttons, the keypad can be locked to prevent
inadvertent button presses while griping the screwdriver body. The Lock Icon is displayed when
the keypad is locked. To unlock the keypad, press the ENTER –UNITS –ENTER buttons in
sequence.
Note: If the keypad was locked when powered down, on power up, the keypad will remain locked and
will require the keypad unlock button sequence of ENTER –UNITS –ENTER to become functional
again.
PROGRESS LIGHTS
Yellow –½ second on/off flashing
indicates 40% of target torque or
angle reached. ¼ second flashing
indicates 60% of target reached.
Continuous on indicates 80% of
target reached.
Green - Indicates target torque or angle
reached.
Red - Indicates exceeded torque or
angle target plus 4% or exceeded
maximum Preset target.
TORQUE ZEROING
ANGLE ZEROING
--
SET STILL
Target Torque Screen
Target Angle Screen
ENTER –UNITS –ENTER
keypad unlock sequence
ENTER
button
00
180°
Lock icon
00
80.00 IN-LB
00
80.00 IN-LB
00
180°
AUDIBLE
ALERT
MODE
COUNT
MODE SELECT AND MENU ENTRY BUTTON
INCREMENT
BUTTON
ON/OFF AND
RE-ZERO
BUTTON
DECREMENT
BUTTON
LCD BACKLIGHT
AND
PEAK TORQUE/ANGLE
RECALL BUTTON
UNITS AND
PRESET ENTRY
BUTTON
TORQUE AND/OR
ANGLE DISPLAY
BATTERY
CONDITION
PROGRESS
LIGHTS
DATA
STORAGE
ALERT
WIRELESS LINK
CONDITION

5
2. Select Measurement Mode.
Toggle between target TORQUE and ANGLE screens by repeatedly pressing ENTER button.
Note: If screwdriver is powered up in torque only measurement mode, angle is not zeroed until keypad
is unlocked and mode is changed to angle measurement mode. The Angle Zero Required screen
will be displayed:
Angle zeroing begins automatically after 2 seconds. Screwdriver should be placed on a stable
surface with no torque applied.
Note: Pressing ENTER button while angle is zeroing will abort zeroing function to allow user to select
another measurement mode.
Torque Mode
1. Set Target.
Use UP/DOWN buttons to change TORQUE target value.
2. Select Units of Measure.
Repeatedly press UNITS button while on target TORQUE screen until desired units are
displayed.
3. Apply TORQUE.
Grasp center of handle and slowly apply torque to fastener until progress lights display green
and a ½ second audible alert and handle vibration alerts you to stop.
4. Release TORQUE.
Note peak TORQUE reading flashing on LCD display for 5 seconds. Pressing BACKLIGHT
button while peak torque is flashing will continue to display value until button is released.
Momentarily pressing UP/DOWN , ENTER or UNITS button will immediately return to target
TORQUE screen. Reapplying TORQUE will immediately start another TORQUE measurement
cycle.
5. Recall Peak TORQUE Reading
To recall last peak TORQUE measurement, press and hold BACKLIGHT button for
approximately 3 seconds. Peak TORQUE will flash for 5 seconds.
Angle Mode
Note: When angle measurement mode is selected for first time following a power on, "ANGLE ZERO
REQUIRED" message is displayed. After two seconds angle zero process begins and screwdriver
must be placed on a stable surface. If ENTER button is pressed before two seconds, screen will
change to torque only mode, angle zero process is skipped.
1. Set target.
Use UP/DOWN buttons to change target ANGLE value.
2. Apply Torque and Rotate Screwdriver.
Grasp center of handle and slowly apply torque to fastener and rotate screwdriver at a
moderate consistent speed until progress lights display green and a ½ second audible alert
and handle vibration alerts you to stop.
3. Release torque.
Note alternating peak TORQUE and ANGLE readings flashing on LCD display for 5 seconds.
Pressing BACKLIGHT button while peak values are flashing will continue to display values
until button is released. Momentarily pressing UP/DOWN , ENTER or UNITS button will
immediately return to target ANGLE screen. Reapplying torque (ratcheting) before target
screen is displayed will continue ANGLE accumulation as screwdriver is rotated.
4. Recall Peak ANGLE Reading
To recall last peak ANGLE measurement, press and hold BACKLIGHT button for
approximately 3 seconds. Peak TORQUE and ANGLE will be displayed alternately for 5
seconds.
ANGLE ZERO REQ

6
Mode Cycle Count
Mode cycle count feature is used to indicate number of times screwdriver
has reached target torque in torque measurement mode or target
angle in angle measurement mode.
Torque and Angle Mode Cycle Counting
1. Numerical counter located in top right of target torque or target angle screen will increment after
each torque or angle cycle if applied torque or angle has reached target value.
2. When toggling between torque mode or angle mode using ENTER button or if target is changed,
numerical counter will reset back to 00. Counter WILL NOT reset when re-zeroing, on menu
entry/exit or power down.
3. Memory icon will turn on indicating at least one torque or angle cycle data has been stored in
memory.
Main Menu
Main menu displays screwdriver operational information.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Use UP/DOWN buttons to highlight menu selection then press ENTER button.
Menu Selections:
EXIT - Exits Main menu and returns to target screen.
SHOW DATA - Displays stored torque and angle data.
CLEAR DATA - Clears stored torque and angle data.
CYCLE COUNT - Displays torque/angle cycle count screen.
LANGUAGE - Displays language selection menu.
SETTINGS - Displays advanced settings menu (see Advanced Settings Section).
CONFIGURE - Displays advanced configuration menu (see Advanced Configuration Section).
PAIR STATE - Displays wireless radio pairing state (see Advanced Settings Section).
Viewing Stored Torque and Angle Data
Torque data is stored in memory after each torque cycle if applied torque has reached target value.
Torque and angle data is stored in memory after each angle cycle if applied angle has reached target
value. Memory Indicator is displayed when data is stored in non-volatile memory.
1. To view stored torque and angle data, from target torque or angle screen, press and hold
ENTER button for 3 seconds.
2. Highlight SHOW DATA menu selection by pressing UP/DOWN buttons then press
ENTER button to display Show Data screen.
3. In Show Data screen, scroll through each stored data record by pressing UP/DOWN buttons.
Example: 02 = Show Data List Counter: TQ = Peak torque value
01 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value
4. Pressing ENTER button while on Show Data screen returns to main menu.
Note: A maximum of 50 data records can be stored in memory. Memory full icon will be displayed when
full. New data is stored at number 50, moving older data down and bumping the oldest from
location 01 until memory is cleared.
01
M180°
MEMORY ICON
MODE CYCLE COUNT
ENTER
button
held
Target Screen
ENTER
button
UP/DOWN buttons
00
M80.00 IN-LB
EXIT
SHOW DATA
CLEAR DATA
02: 15:40:15
2018/01/26
TQ:80.20 IN-LBS
01: 15:35:05
2018/01/26
80.35 IN-LBS84°

7
Note: Date and Time is blank if real-time-clock has not been set (see Setting Date and Time in the
Advanced Configuration section.
Deleting Stored Torque and Angle Data
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CLEAR DATA menu selection using UP/DOWN buttons then press ENTER button to display
CLEAR ALL DATA screen.
3. In CLEAR ALL DATA screen, highlight YES menu selection to delete all stored data, or NO menu
selection to exit without deleting data.
4. Press ENTER button after making selection.
Viewing and Clearing Screwdriver Cycle Counter
Each time torque or angle target is reached, screwdriver cycle counter is incremented. Maximum cycle
count is 999999.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CYCLE COUNT menu selection using UP/DOWN buttons.
3. Press ENTER button to display CYCLE COUNT screen.
4. To exit CYCLE COUNT screen without clearing count, press ENTER button while EXIT menu selection
is highlighted.
5. To reset screwdriver cycle count to 0, highlight CLEAR menu selection then press ENTER button.
6. EXIT menu selection is automatically highlighted after count is cleared. Press ENTER button to
return to main menu.
Language
1. To select language menu, press ENTER button while LANGUAGE is highlighted then highlight
desired language and press ENTER button.
2. Decimal Mark selection menu is displayed. Decimal separator can be a comma or decimal point.
Use UP/DOWN buttons to select decimal separator then press the ENTER button.
ENTER
button
held
Target Screen
UP/DOWN buttons
ENTER
button
ENTER
button
00
M80.00 IN-LB
UP/DOWN buttons
EXIT
SHOW DATA
CLEAR DATA
EXIT
SHOW DATA
CLEAR DATA
CLEAR ALL DATA
YES
NO
CLEAR ALL DATA
YES
NO
EXIT
SHOW DATA
CLEAR DATA
ENTER
button
held
Target Screen
UP/DOWN buttons
ENTER
button
00
M80.00 IN-LB
EXIT
SHOW DATA
CLEAR DATA
UP/DOWN buttons
COUNT: 12
CLEAR
EXIT
COUNT: 0
CLEAR
EXIT
SHOW DATA
CLEAR DATA
CYCLE COUNT
ENTER
button
COUNT: 12
CLEAR
EXIT
ENTER
button
SHOW DATA
CLEAR DATA
CYCLE COUNT
ENTER button

8
3. To exit Main menu and return to target torque or angle screen, press ENTER button while EXIT
menu selection is highlighted.
Target Presets (PSET)
PSET function gives user ability to configure 10 preset target torque or target angle settings, each with
a target, minimum, maximum (over range) and batch count value. PSETs are stored in non-volatile
memory so that they are retained while power is off.
Note: After adding a Preset (see below), navigate between manual target torque, angle mode and PSET
screen by repeatedly pressing ENTER button. While PSET screen is displayed, press
UP/DOWN buttons to select additional configured PSETs.
Note: Presets with a non-zero batch count are displayed as 01ofXX.
Adding a Torque Preset
1. From manual target torque screen, select units of measure.
2. Press and hold UNITS button for 3 seconds.
3. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using
UP/DOWN buttons then press ENTER button. NO menu selection returns to main menu without
adding a PSET.
4. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM TORQUE value is the manual TARGET TORQUE
value. MINIMUM TORQUE can be set to any value from screwdriver minimum torque range to full
scale torque range by pressing UP/DOWN buttons. Once desired minimum torque value has been
set, press ENTER button.
ENTER
button
Language Selection menu
ENTER button
Decimal Mark Selection menu
ENTER
button
held
Target Screen
00
80.00 IN-LB
EXIT
SHOW DATA
CLEAR DATA
UP/DOWN buttons
ENTER
button
ENGLISH
FRANCAIS
ESPANOL
CLEAR DATA
CYCLE COUNT
LANGUAGE
ENTER
button
DECIMAL MARK
COMMA (1,23)
POINT (1.23)
UP/DOWN buttons
DECIMAL MARK
COMMA (1,23)
POINT (1.23)
00
80,00 IN-LB
ENTER
button
Preset 1 Torque Screen
Preset 2 Angle Screen
UP/Down buttons
Manual Target Angle Screen
Preset 3 Torque Screen
ENTER
button
UP/Down buttons
ENTER
button
ENTER
button
UP/Down buttons
Manual Target Torque Screen
UP/Down buttons
00
80.00 IN-LB
00
90°
PSET 01 01of03
80.00 IN-LB
PSET 02 01of04
90°
PSET 03 00
50.00 IN-
LB

9
5. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red
progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE value or
MINIMUM TORQUE value (whichever is larger) plus 4%. Maximum torque value can be set greater
than MINIMUM TORQUE value to 10% above screwdriver maximum range by pressing UP/DOWN
buttons. Once desired maximum torque value has been set, press ENTER button.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time
target torque is reached if a batch count of zero is entered. Mode Count decrements if a non-zero
batch count is entered and resets to batch count value when count reaches zero. Once desired
batch count value has been set, press ENTER button.
7. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
8. To enter additional torque presets, repeatedly press ENTER button until target torque screen is
displayed and repeat steps above.
Adding an Angle Preset
1. From manual target angle screen, press and hold UNITS button for 3 seconds.
2. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using
UP/DOWN buttons then press ENTER button. NO menu selection returns to main menu without
adding a PSET.
3. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM ANGLE value is TARGET ANGLE value.
MINIMUM ANGLE can be set from 0 to 360° by pressing UP/DOWN buttons. Once desired
minimum angle value has been set, press ENTER button.
4. MAXMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red
progress lights turn on. Initial MAXIMUM ANGLE value will be TARGET ANGLE or MINIMUM ANGLE
(whichever is larger) plus 4. MAXIMUM ANGLE value can be set to any value greater than MINIMUM
ANGLE by pressing UP/DOWN buttons. Once desired value has been set, press ENTER button.
5. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time
target angle is reached if a batch count of zero is entered. Mode Count decrements if a non-zero
batch count is entered and resets to batch count value when count reaches zero. Once desired
batch count value has been set, press ENTER button.
6. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
7. To enter additional angle presets, repeatedly press ENTER button until target angle screen is
displayed and repeat steps above.
ENTER
button
ENTER
button
UP/DOWN buttons
ENTER
button
UNIT
button
held
Target Torque Screen
UP/DOWN buttons
ENTER
button
UP/DOWN buttons
ENTER button
UP/DOWN buttons
Preset Torque Screen
00
80.00 IN-LB
ADD PRESET
YES
NO
ADD PRESET
YES
NO
MINIMUM TORQUE
80.00 IN-LB
MAXIMUM TORQUE
83.20 IN-LB
BATCH COUNT
3
PSET 01 01of03
80.00 IN-LB

10
Editing a Preset
Edit PSET function gives user ability to edit stored PSETS on screwdriver.
1. From Preset screen to be edited, press and hold UNITS button for 3 seconds.
2. CHANGE PRESET screen is displayed.
3. Highlight EDIT selection using UP/DOWN buttons then press ENTER button.
4. MINIMUM TORQUE or MINIMUM ANGLE screen is displayed. Value can be changed by pressing
UP/DOWN buttons. Once desired torque or angle value has been set, press ENTER button.
5. MAXMUM TORQUE or MAXMUM ANGLE screen is displayed next. Value can be changed by
pressing UP/DOWN buttons. Once desired torque or angle value has been set, press
ENTER button.
6. BATCH COUNT screen is displayed next. Value can be changed by pressing UP/DOWN buttons.
Once desired batch count value has been set, press ENTER button.
7. PSET target screen is displayed labeled with same PSET number.
Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without editing PSET.
ENTER
button
UP/DOWN buttons
ENTER
button
UNIT
button
held
Target Angle Screen
UP/DOWN buttons
ENTER
button
ENTER
button
UP/DOWN buttons
ENTER button
UP/DOWN buttons
Preset Angle Screen
00
90°
ADD PRESET
YES
NO
ADD PRESET
YES
NO
MINIMUM ANGLE
90°
MAXIMUM ANGLE
94°
BATCH COUNT
4
PSET 02 01of04
90°
ENTER
button
UP/DOWN buttons
ENTER
button
UNIT
button
held
Target Angle Screen
UP/DOWN buttons
ENTER
button
ENTER
button
UP/DOWN buttons
ENTER button
UP/DOWN buttons
Preset Angle Screen
00
90°
DELETE
EDIT
EXIT
DELETE
EDIT
EXIT
MINIMUM ANGLE
90°
MAXIMUM ANGLE
94°
BATCH COUNT
0
PSET 02 00
92°

11
Deleting a Preset
Delete PSET function allows user to remove stored presets from screwdriver.
1. From Preset screen to be deleted, press and hold UNITS button for 3 seconds.
2. CHANGE PRESET screen is displayed.
3. Highlight DELETE menu selection using UP/DOWN buttons and press ENTER button.
4. Target screen is displayed and deleted PSET is no longer available for selection.
Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without deleting PSET.
Note: When a PSET is deleted, all other stored PSET’s will retain their original PSET numbers. When a
new PSET is entered, it will be assigned first available PSET number in sequence.
ENTER button
UNIT
button
held
Target Torque Screen
UP/DOWN buttons
ENTER button
Preset Angle Screen
PSET 02 00
92°
DELETE
EDIT
EXIT
DELETE
EDIT
EXIT
00
80.00 IN-LB

12
Advanced Settings
Accessing Advanced Settings
Advanced settings are accessed from SETTINGS menu selection on main menu.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight SETTINGS menu selection using UP/DOWN buttons.
3. Press ENTER button to display Settings menu.
Menu Selections:
EXIT - Exits Settings menu and returns to target screen.
SHOW INFO - Displays screwdriver operational information.
SLEEP TIME - Displays power down interval setup screen.
LCD CONTRAST - Displays LCD contrast setup screen.
KEY BEEP - Displays button press beep enable/disable setup screen.
TARGET BEEP - Displays target beep enable/disable setup screen.
AUTO BACKLIGHT - Displays auto backlight enable/disable screen to turn on backlight during
measurement.
TOGGLE BACKLGHT - Displays BACKLIGHT button toggle or timeout enable/disable screen.
VIBRATOR CONFIG - Displays vibrator ON/OFF configuration for when target reached.
BATTERY TYPE –Displays the battery type selection screen.
PAIRING MODE –Displays wireless radio pairing mode selection screen.
4. To exit Settings menu and return to target torque or angle screen, press ENTER button while EXIT
menu selection is highlighted.
Note: All user configurable settings are stored in non-volatile memory and are retained while power is
off.
Show Info
Show Info menu selection displays screwdriver operational information.
1. From Settings menu, press ENTER button while SHOW INFO selection is highlighted.
2. SHOW INFO screen is displayed.
3. UP/DOWN buttons are used to scroll screen.
Operational Information:
CAL: Date of last screwdriver calibration.
ISD: In-Service Date (remains blank until real-time-clock set).
TCF: Torque Calibration Factor.
ACF: Angle Calibration Factor.
VER: Software version.
RADIO: Radio Name
#: Asset Tag
OVR CNT: Overtorque Counter tracks how many times an over-torque event occurred on
screwdriver (torque >125% of full scale).
TQZ: Torque Zero Offset.
ANZ: Angle Zero Offset.
AFS+: Angle Zero Offset at CW Torque Full Scale.
UP/DOWN buttons
ENTER
button
held
Target Screen
ENTER
button
00
80.00 IN-LB
EXIT
SHOW DATA
CLEAR DATA
CYCLE COUNT
LANGUAGE
SETTINGS
EXIT
SHOW INFO
SLEEP TIME

13
AFS-: Angle Zero Offset at CCW Torque Full Scale.
TFS+: CW Torque Full Scale.
TFS-: CCW Torque Full Scale.
Copyright
4. Pressing ENTER button exits Show Info screen and returns to Settings menu.
Setting Sleep Time
This function will allow user to set interval screwdriver enters power-down state following last applied
torque or button press.
1. From Settings menu, use UP/DOWN buttons to highlight SLEEP TIME selection then press
ENTER button.
2. SLEEP TIME screen is displayed.
3. Use UP/DOWN buttons to select sleep interval.
Selectable Intervals:
2 MIN (factory default)
5 MIN
10 MIN
30 MIN
1 HR
2 HR
8 HR
4. Press ENTER button to accept selection and exit to Settings menu.
Setting LCD Contrast
This function will allow user to set LCD contrast for optimal viewing.
1. From Settings menu, use UP/DOWN buttons to highlight LCD CONTRAST selection then press
ENTER button.
2. CONTRAST screen is displayed.
3. Use UP/DOWN buttons while viewing display to change contrast to desired level.
Selectable levels: 20 to 80 in increments of 5 (factory default = 40).
4. Press ENTER button to accept selection and exit to Settings menu.
EXIT
SHOW INFO
SLEEP TIME
CAL: 2018/01/01
ISD:
TCF: 4220
ENTER
button
UP/DOWN buttons
TFS+: 16155
TFS-: -16130
© 2018 SNAP-ON
ENTER
button
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
EXIT
SHOW INFO
SLEEP TIME
SLEEP TIME
2 MIN
EXIT
SLEEP TIME
8 HR
EXIT

14
Key Beep Setup
This function will allow user to enable or disable audio feedback when a button is pressed.
1. From Settings menu, use UP/DOWN buttons to highlight KEY BEEP selection then press
ENTER button.
2. KEY BEEP screen is displayed.
3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection.
4. Press ENTER button to accept selection and exit to Settings menu.
Target Beep Setup
This function will allow user to enable or disable audio feedback when target torque or angle is
reached. Audio feedback occurs on torque or angle over range (red LED) regardless of this setting.
1. From Settings menu, use UP/DOWN buttons to highlight TARGET BEEP selection then press
ENTER button.
2. TARGET BEEP screen is displayed.
3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection.
4. Press ENTER button to accept selection and exit to Settings menu.
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
SHOW INFO
SLEEP TIME
LCD CONTRAST
CONTRAST: 20
CONTRAST: 80
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
SLEEP TIME
LCD CONTRAST
KEY BEEP
KEY BEEP
ENABLE
DISABLE
KEY BEEP
ENABLE
DISABLE
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
LCD CONTRAST
KEY BEEP
TARGET BEEP
TARGET BEEP
ENABLE
DISABLE
TARGET BEEP
ENABLE
DISABLE

15
Auto Backlight Setup
This function will allow user to enable or disable backlight from turning on during torque or angle
measurement.
1. From Settings menu, use UP/DOWN buttons to highlight AUTO BACKLIGHT selection then press
ENTER button.
2. AUTO BACKLIGHT screen is displayed.
3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection.
4. Press ENTER button to accept selection and exit to Settings menu.
Toggle Backlight Setup
This function will allow user to enable or disable backlight toggle function. If toggle mode is disabled,
BACKLIGHT button turns on backlight and it automatically turns off after five seconds following any
last button press. If toggle mode is enabled, a BACKLIGHT button press will turn on backlight and it
will remain on until next BACKLIGHT button press.
1. From Settings menu, use UP/DOWN buttons to highlight TOGGLE BACKLGHT selection then press
ENTER button.
2. TOGGLE BACKLGHT screen is displayed.
3. Use UP/DOWN buttons to highlight ENABLE or DISABLE (factory default) selection.
4. Press ENTER button to accept selection and exit to Settings menu.
Note: Backlight will turn off when screwdriver powers down either by POWER button press or sleep
time.
Note: If toggle backlight is enabled and backlight is on, backlight will remain on during and after
applying torque.
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
LCD CONTRAST
KEY BEEP
AUTO BACKLIGHT
AUTO BACKLIGHT
ENABLE
DISABLE
AUTO BACKLIGHT
ENABLE
DISABLE
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
KEY BEEP
AUTO BACKLIGHT
TOGGLE BCKLGHT
TOGGLE BCKLGHT
ENABLE
DISABLE
TOGGLE BCKLGHT
ENABLE
DISABLE

16
Vibrator Configuration
This function will allow user to configure vibrator for On or Off when target is reached for preference
and/or battery power savings.
1. From Settings menu, use buttons to highlight VIBRATOR CONFIG selection then press ENTER
button.
2. VIBRATOR CONFIG screen is displayed.
3. Use UP/DOWN buttons to toggle ON or OFF selection.
4. Press ENTER button to accept selection and exit to Settings menu.
Battery Type Selection
This function will allow user to configure the battery discharge thresholds for the type of battery used.
1. From Settings menu, use UP/DOWN buttons to highlight BATTERY TYPE selection then press
ENTER button.
2. BATTERY TYPE screen is displayed.
3. Use UP/DOWN buttons to select the type of battery being used.
4. Press ENTER button to accept selection and exit to Settings menu.
Note: Screwdriver is configured for Alkaline battery shipped from factory. If Alkaline battery is
replaced with Lithium or rechargeable Nickel-Metal Hydride (NIMH), battery type should be
changed so battery level icon and LOW battery warnings function optimally. Battery life
(REPLACE) will not be impacted, however 50% and Low will be optimized to show most accurate
linear discharge time.
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
AUTO BACKLIGHT
TOGGLE BCKLGHT
VIBRATOR CONFIG
VIBRATOR CONFIG
ENABLE
DISABLE
VIBRATOR CONFIG
ENABLE
DISABLE
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
TOGGLE BCKLGHT
VIBRATOR CONFIG
BATTERY TYPE
LITHIUM
ALKALINE
NIMH
LITHIUM
ALKALINE
NIMH

17
Pairing Mode Selection
Screwdriver can be paired with a mobile device for increased security. Screwdriver supports two
pairing modes: 1) NO PIN and 2) RANDOM PIN. In either mode, pairing screwdriver to a mobile
device must be initiated from mobile device. If NO PIN mode is selected, neither screwdriver nor
mobile device will ask for a PIN during pairing process. This method is simpler but less secure than
RANDOM PIN method. If RANDOM PIN mode is selected, mobile device will ask for a PIN when
pairing is initiated, and screwdriver will display a randomly-generated PIN. User enters PIN into
mobile device dialog to complete pairing process.
1. From Settings menu, use UP/DOWN buttons to highlight PAIRING MODE selection then press
ENTER button.
2. PAIRING MODE screen is displayed.
3. Use UP/DOWN buttons to select type of pairing mode used.
4. Press ENTER button to accept selection and exit to Settings menu.
Note: PIN is displayed on screwdriver during pairing with mobile device. Enter PIN into device when
requested. Display returns to normal after connection:
Pair State
Pair state of screwdriver to a mobile device is displayed on main menu. This function allows user to
unpair screwdriver from mobile device if paired.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight PAIR STATE menu selection using UP/DOWN buttons.
3. Press ENTER button to display Pair State.
4. To exit Settings menu and return to target torque or angle screen, press ENTER button while EXIT
menu selection is highlighted.
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
VIBRATOR CONFIG
BATTERY TYPE
PAIRING MODE
PAIRING MODE
NO PIN
EXIT
PAIRING MODE
RANDOM PIN
EXIT
PIN
964046

18
Note: If state of pairing is UNPAIRED, UP/DOWN buttons have no effect.
Note: If screwdriver has been paired using RANDOM PIN, screwdriver should be unpaired and set back
to NO PIN if paring is no longer used.
ENTER
button
held
Target Screen
UP/DOWN buttons
00
80.0 IN-LB
EXIT
SET HEAD LENGTH
SHOW DATA
ENTER
button
SETTINGS
CONFIGURE
PAIR STATE
PAIR STATE
UNPAIRED
EXIT
Screwdriver not paired with mobile device
PAIR STATE
UNPAIR
EXIT
Screwdriver paired with mobile device
PAIR STATE
UNPAIR
EXIT
UP/DOWN buttons
ENTER button
Unpair screwdriver from mobile device

19
Advanced Configuration
Accessing Advanced Configuration
Advanced configuration is accessed from CONFIGURE menu selection on main menu.
Note: If screwdriver has been locked (see Preset Lock and Job Mode), a password entry is required to
enter Configure menu.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CONFIGURE menu selection using UP/DOWN buttons.
3. Press ENTER button to display Configure menu.
Menu Selections:
EXIT - Exits Configure menu and returns to target torque or angle screen.
MODE SETUP - Displays screwdriver mode setup menu.
PRESET LOCK - Displays Preset lock menu.
DELETE PRESETS - Displays delete all presets menu.
JOB MODE - Displays Job mode menu.
MENU LOCK –Password protects all menus.
CALIBRATION - Displays screwdriver calibration menu (password protected).
SET DATE/TIME - Displays clock date and time entry screens.
CHANGE PASSWD - Displays change password menu.
ASSET TAG - Displays user configurable 15-character string.
BLE ENABLE –Enables or disables BLE radio.
4. To exit Configure menu and return to target torque or angle screen, press ENTER button while EXIT
menu selection is highlighted.
Note: All user configurable settings are stored in non-volatile memory and are retained while power is
off.
Mode setup menu allows user configure target torque and angle minus and plus tolerances and
enable/disable Torque THEN Angle mode and Torque AND angle mode.
1. From Configure menu, press ENTER button while MODE SETUP selection is highlighted.
2. Mode Setup menu is displayed.
Menu Selections:
EXIT - Exits Mode setup menu and returns to Configure menu screen.
TQ-% SETUP - Displays target torque minus tolerance entry screen.
TQ+% SETUP - Displays target torque plus tolerance entry screen.
ANG-% SETUP - Displays target torque minus tolerance entry screen.
ANG+% SETUP - Displays target torque plus tolerance entry screen.
THEN DISABLED - Displays THEN Mode enable/disable screen.
AND DISABLED - Displays AND Mode enable/disable screen.
3. Use UP/DOWN buttons to highlight menu selections.
4. Press ENTER button while EXIT menu selection is highlighted to return to Configure menu.
UP/DOWN buttons
ENTER
button
held
Target Screen
ENTER
button
00
80.00 IN-LB
EXIT
SHOW DATA
CLEAR DATA
LANGUAGE
SETTINGS
CONFIGURE
EXIT
MODE SETUP
DELETE PRESETS
EXIT
TQ-% SETUP
TQ+% SETUP
EXIT
MODE SETUPs
PRESET LOCK
ENTER
button
Configure menu
Mode Setup menu
Table of contents
Other Snap-On Power Screwdriver manuals
Popular Power Screwdriver manuals by other brands

Universal Tool
Universal Tool UT8226 Operator instructions

Deprag
Deprag MINIMAT-ULTRA 347-220-31LV Operating instruction booklet

EINHELL
EINHELL TC-SD 3,6 Li Original operating instructions

EIBENSTOCK
EIBENSTOCK ESR 500 operating instructions

DeWalt
DeWalt DCF620 Original instructions

Universal Tool
Universal Tool UT8958 Operator instructions