Soca ST-680 Specification sheet

ST-680
NETWORK PROXIMITY ACCESS CONTROL OPERATION
AND INSTALLATION MANUAL
SOCA TECHNOLOGY CO.,LTD.
2000 JULY

2
CONTENTS
1. Features introductions 3
2. Reader Front panel & types of proximity card 4
3. Operationinstructions. 5
Start reader 5
Mode inquiry 5
Anti-duress 5
Setupmode 5
4. Quicksetting 6
5. Setup mode function selection instructions (00 ~ 28) 6
(01) Add new card (17) Auto record range
(02) Delete card (18) Main reader location
(04) Shunt time (19) Door shutting time
(05) Open door mode (20) Alarm mode
(07) Reset to release alarm (21) Anti-duress alarm mode
(08) Change system password (22) Door sensing mode
(09) Reset to release anti-duress alarm (23) Anti-theft sensing mode
(10) Reader ID number (24) Push button door open sensing mode
(11) Password error times (25) BEEP sound mode
(12) Anti-duress code (26) Print mode
(13) Total cards (27) Anti-pass mode
(14) Program version (28) Display card number mode
(15) Set time (00) Instant door open
(16)Setdate
6. Installationinstructions 19
Reader connector 19
Wiring connection for additional electric lock and push button door open switch 20
Wiring connection for additional magnetic door sensing 21
Wiring connection for anti-theft sensing (NO Type) 21
Wiring connection for additional alarm 21
Wiring connection for linking with computer 22
7. Hardwarespecifications 23
8. Attentions 23
9. Troubleshooting 23

3
ST-680 OPERATION INSTRUCTIONS
1. Features introductions
★ When connecting with computer, it can be used for data inquiry and function setting
simultaneously. (Door open/close, start alarm system, etc). It can also operate solely to
manage access control.
★ Function setting can be done by computer or reader itself. (Single registration or deletion,
door open time, etc).
★ The capacity data input/output can reach up to 6,000 by single reader operation. When
linking with computer, its data input/output capacity can be unlimited.
★ Main reader has 9,000 card registrations capability. Each card can be self-setting for
personal password and effective in/out time.
★ Main reader has 48 units of time zone. Each time zone unit also has 5 time ranges for
self-setting by user.
Example: It can be set from “G” hour “H” minute to “I” hour “J” minute on every
Mondays, Wednesdays, Saturdays in periodic of “A” year “B” month “C” day
to “D” year “E” month “F” day as effective in/out time range.
★ Directly link to series type printer for direct data printing.
★ Additional sub-reader for in/out control.
★ Equipped with hardware self-testing function
★ Internal batteries will provide power supply when power cut occurred to prevent any data
from being erased and system time can operate as normal.
★ Main reader access control’s range:
* Card number -It must be registered before use.
* Password -Personal password has to key in to open the door.
* Time zone -Setting the effective of year, month, day, time range, Monday ~
Sunday
* Special holidays -User could set any holidays as to prevent any unauthorized access.
* Error control -Alarm will activate when “N” times of consecutive error password
entering occurred.
* Anti-pass -The card could only be used for matching single entry and exit.
(Otherwise, it will be considered the card has been duplicated causing
access denial.)
★ Main reader’s sensing range:
* Anti-tamper - when the reader is tampered, alarm will be activated.
* Anti-theft - Alarm will be activated when sensing any abnormal operations.
* Illegal door open - Alarm will be activated when door is destroyed and opened by force.

4
* Anti-duress - It will operate when password and duress code are keyed in to send help
signal to the nearest police station. It must be done manually to disable
anti-duress function.
* Exceed door shut time - Alarm will be activated, when door is not closed exceeding initial
time setting control.
* Door open button sensing - Door will open immediately when the button is pushed.
2. Reader Front Panel & Types of Proximity Card
(a) Front Panel Indicator Lights
(1). POWER (red) :power indicator.
(2). OK (green) :door open indicator.
(3). DENY (yellow) : operation error or unregistered card indicator.
(4). STATUS (yellow) :system starts and setup mode indicator.
(b) 10 entry (buttons), two function keys: “#”&“*”.
#key : input data confirm key (Enter)
*key : clear or escape key (CLR/ESC)
(c) Types of proximity card
SC-10 thin card:
ISO standard card size, thickness 0.8 m/m. Card-printing machine can
be used to print user photo or picture directly. Read range, 25cm
SC-20 thick card:
ISO standard card size, thickness 1.78 m/m. Card-printing machine
can be used to print user photo or picture directly. It can also be used
as hang plate. Read range, 25 cm.
SC-30 key tag:
Key ring type designed, easy hand carrying, supersonic welding,
waterproof, shockproof. Dimensions: 51mm (L), 32mm(H), 7.8mm(W).
Read range, 10 cm.
12345678

5
SYSTEM FUNCTIONS
SELECTION :
_ _
MD ADR YYYY/MM/DD
2 001 1999 / 01 / 01
3. Operation instructions
Start reader: It will begin self-testing function when power is switched on. Its operation
procedures are as follow:
LCD DISPLAY INSTRUCTIONS
SRAM TESTING Memory testing
RTC TESTING Real time clock testing
INITIAL FUNCTION Initial system setting
<<ST680>> 08:05
0010
Model (ST680), present time (08:05), 10 registrations.
Note: Card must not exceed the read range (refer to different models) to gain induction.
a). OK (green) light is on to indicate registered card to gain access.
b). DENY (yellow) light is on and consecutive beeping sound is on to indicate
unregistered card or used under unauthorized time zone. (Please refer to
troubleshooting if neither of above statuses occurred)
Mode inquiry: Press *##, LCD will display:
MD: open door mode (2 shows door open by proximity card sensing, 3 shows
door open by proximity card sensing with password.)
ADR: main reader number. YYYY/MM/DD: current date.
Re-press *to escape.
Anti-duress: When under duress, user may press *button before keying in password to
activate alarm.(Duress code presetting is *, it can be changed by user)
Example : anti-duress code is 1, password is 1234, then to activate
anti-duress alarm, the user should key in 11234.
Setup Mode:
User must get into setting mode first before changing any
system functions. User must key in #system password
#for system function selection. System password is being
set 5678 initially by manufacturer. (Example: User can
get into the set up mode by keying #5678#).

6
SYSTEM FUNCTIONS
SELECTION : _ _
4. Quick setup:
User will get into the setup mode as the right diagram
shown for any setting to be made.
(A) Add new card , key in 01then key in 00000001.
8-digitcardnumber
(B) Delete card, key in 02then key in 00000001.
8-digitcardnumber
(C) Door open time, key in 04then key in the seconds 003.
(D) Change reader number, key in 10then key in the reader number002.
(E) Door open mode, key in 05then key in the mode code 2.
(F) Time setting, key in 15then key in the time 130015.
13:00:15
(G) Date setting, key in 16then key in 200001016.
2000/01/01 (6)
Note: (1)Sunday (2)Monday (3)Tuesday (4)Wednesday (5)Thursday (6)Friday (7)Saturday
(H) Release alarm, key in 07, confirmed then press #.
( I ) Release anti-duress alarm, key in 09, confirmed then press #.
5. SETTING MODES & FUNCTIONS
Function (01) Add new card:
Either key in 8-digit card number or use proximity card to register, both can be accepted but
should be registered prior using.
Queuing 8-digit card number input,
key in manually or by proximity.
Registration successful,
beep sound occurred.
Registration repeated, beep
sound on continuously.
ADD ONE CARD
00000001
ADD ONE CARD
ACCESS DENIAL
ADD ONE CARD
_ _ _ _ _ _ _ _
SYSTEM FUNCTIONS
SELECTION : _ _ Key in 01
status light on, display
function selection.
Key in
#system password#
back to system function selection.
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 01.
Go into system function setup.

7
Function (02) Delete card:
Deletion of user’s card (such as loss of card or to prevent specific user to gain access) can
be achieved by keying 8-digit card number indicated on the proximity card.
Function (04) Shunt time:
Setting of relay’s ON/OFF time in the proximity reader can be set from 01-255 seconds.
(pre-setting time is 003)
NO such card, beep
sound on continuously.
DELETE ONE CARD
00000001
DELETE ONE CARD
ACCESS DENIAL
DELETE ONE CARD
_ _ _ _ _ _ _ _
SYSTEM FUNCTIONS
SELECTION : _ _ Key in 02
Key in #or *
Key in the #or *
Esc system function selection.
Go into function 02.
back to system function selection.
Deletion successful, a
beep sound occurred.
Key in
#system password#
status light on, display
function selection.
queuing 8-digit card number input,
key in manually or by proximity.
Go into system function setup.
Queuing for shunt time input.
SET SHUNT TIME
( 1 - 255 ) : 003 000
SET SHUNT TIME
( 1 - 255 ) : 003 005
SET SHUNT TIME
( 1 - 255 ) : 003 _ _ _
Key in 04
Key in #or *
Key in the #or *
Go into function 04.
Esc system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
Key in
#system password#
status light on, display
function selection.
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

8
Function (05) Door open mode:
Reader has 2 types of identification modes. (pre-setting figure is 002)
Mode (2). Card proximity door opening: The door will be opened, when the card is sensed.
Mode (3). Door open by proximity card and password: The door will be opened by keying
additional 4-digit password after sensing the registered card.
Function (07) Reset to release alarm:
User sets to release the alarm.
Queuing the identification
mode input.
IDENTIFICATION
MODE ( 2 - 3 ) : 1
IDENTIFICATION
MODE ( 2 - 3 ) : 3
IDENTIFICATION
MODE ( 2 - 3 ) : 2
Key in 05
Key in #or *
Key in the #or *
Go into function 05.
Esc system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing the alarm input
is reset or not.
Setting successfully,
alarm is released.
ALARM RELEASED
YES => “ # “
Key in 07
Key in #or *
Press other keys
Key in the #
Esc system function selection.
Go into function 07.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
back to system function selection.

9
Function (08) Change system password:
The reader’s password is being set at 5678 initially by manufacturer. In order to enter
into system setting mode for the first time, user must key in the initial system password –5
678. User may change the system password after entering into system setting mode.
Function (09) Reset to release anti-duress alarm:
User sets to release the anti-duress alarm.
Beep sound on consecutively,
error input. (first and last 4-
digit password different)
Queuing new system
password input.
Input successfully (4 digits).
Error input.
INPUT NEW SYSTEM
PASSWORD : 1234
INPUT NEW SYSTEM
PASSWORD : 12# _
INPUT NEW SYSTEM
PASSWORD : _ _ _ _
Key in 08
Esc system function selection.
Key in #or *
Key in the #or *
Re-enter new system
password for confirmation.
CONFIRM SYSTEM
PASSWORD : 1234
CONFIRM SYSTEM
PASSWORD : 0000
Input successfully. (same password)
Esc system function selection.
Go into function 08.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
CONFIRM SYSTEM
PASSWORD : _ _ _ _
Queuing for anti duress
alarm released or not.
Setting successfully, anti-
duress alarm is released.
DURESS RELEASED
YES => “ # “
Key in 09
Key in #or *
Press other keys
Key in the #
Esc system function selection.
Go into function 09.
back to system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.

10
Function (10) Reader ID number:
Each reader has a reader ID number for computer identification and the number should not
be repeated. (pre-setting figure is 001)
Function (11) Password error times:
Alarm will be activated when “N” times of consecutive error password entering occurred.
(pre-setting figure is 003)
Queuing for reader ID
number input.
READER ID NUMBER
( 1 - 255 ) : 001 256
READER ID NUMBER
( 1 - 255 ) : 001 002
READER ID NUMBER
( 1 - 255 ) : 001 _ _ _
Key in 10
Key in #or *
Key in the #or *
Go into function 10.
Esc system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for password
error times input.
ERROR TIMES
( 1 - 255 ) : 003 256
ERROR TIMES
( 1 - 255 ) : 003 002
ERROR TIMES
( 1 - 255 ) : 003 _ _ _
Key in 11
Key in #or *
Key in the #or *
Esc system function selection.
Go into function 11.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.

11
Function (12) Anti-duress code :
Set up of anti-duress code (*,0〜9). (pre-setting code is *)
Function (13) Total cards:
Display total number of current registered cards.
Function (14) Program version:
Display program version.
Queuing for anti-duress
code input.
SET DURESS CODE
0 - 9 , *: *9
SET DURESS CODE
0 - 9 , *: *_
Key in 12
Key in #or *
Key in the #or *
Esc system function selection.
Go into function 12.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
back to system function selection.
Display total number of
current registered cards.
USER CARD COUNT
0200
Key in 13
Key in #or *
Press any key
Esc system function selection.
Go into function 13.
back to system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Display program version.
VERSION : V1﹒08
Key in 14
Key in #or *
Esc system function selection.
Press any key
Go into function 14.
back to system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.

12
Function (15) Set time:
Example: 18 hour 00 minute 00 second => 18:00:00 (pre-setting figure is 00:00:00)
Function (16) Set date:
Example 2000/04/30 Sunday => 2000/04/30 (1) (pre-setting is 2000/01/01 (5))
Queuing for system
time input.
SET TIME
17 : 50 : 99
SET TIME
18 : 00 : 00
SET TIME
1
17 : 50 : 50
Key in 15
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 15.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for system
date input.
SET DATE
1999 / 03 / 29 (0 )
SET DATE
1999 / 03 / 29 ( 1 )
SET DATE
1999 / 01 / 01 ( 5 )
Key in 16
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 16.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

13
Function (17) Auto Record range:
This is to set under what kind of status to save by stand alone operation. (pre-setting figure
is 003). There are 4 kinds of status to choose:
A. Detect point / output action. (+1) B. Computer special command. (+2)
C. Single reader operation status. (+4) D. User error status. (+8)
Example:
If A and B statuses are chosen, the setting figure for auto record range is 3 (1+2)
If A, B, and D statuses are chosen, the setting figure for auto record range is 11 (1+2+8)
Function (18) Main reader location:
To show the location of the reader: (0) Indoor, (1) outdoor. (pre-setting location is 001)
Queuing for main reader
location input.
READER=>0 / INDOOR
1 /OUTDOOR : 2
READER=>0 / INDOOR
1 /OUTDOOR : 0
READER=>0 / INDOOR
1 /OUTDOOR : 1
Key in 18
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 18.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for auto
record range input.
AUTO REC RANGE
( 1 - 255 ) : 012 256
AUTO REC RANGE
( 1 - 255 ) : 012 011
AUTO REC RANGE
( 1 - 255 ) : 012 _ _ _
Key in 17
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 17.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.

14
Function (19) Door shutting time:
Time setting for sensing door-shutting time as to activate the alarm when exceeding the set
value. (pre-setting value is 030)
Function (20) Alarm mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000) Once set at “ OFF “ , alarm
will not function.
Queuing for door
shutting time input.
DOOR SENSOR SEC
( 1 - 255 ) : 030 256
DOOR SENSOR SEC
( 1 - 255 ) : 030 015
DOOR SENSOR SEC
( 1 - 255 ) : 030 _ _ _
Key in 19
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 19.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for alarm
mode input.
ALARM MODE
( 0 / ON , 1 / OFF ) : 2
ALARM MODE
( 0 / ON , 1 / OFF ) : 0
ALARM MODE
( 0 / ON , 1 / OFF ) : 1
Key in 20
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 20.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

15
Function (21) Anti-duress alarm mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “,
anti-duress alarm will not function.
Function (22): Door sensing mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function at any abnormal door opening.
Queuing for anti-
duress mode input.
ANTI-DURESS MODE
( 0 / ON , 1 / OFF ) : 2
ANTI-DURESS MODE
( 0 / ON , 1 / OFF ) : 0
ANTI-DURESS MODE
( 0 / ON , 1 / OFF ) : 1
Key in 21
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 21.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for door
sensing mode input.
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 2
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 1
DOOR SENSOR MODE
( 0 / ON , 1 / OFF ) : 0
Key in 22
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 22.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

16
Function (23) Anti-theft sensing mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function at any cases of broken in.
Function (24) Push button door opening sensing mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, the
sensing mode will not function if the push button is pressed.
Queuing for anti-
theft mode input.
ANTI-THEFT MODE
( 0 / ON , 1 / OFF ) : 2
ANTI-THEFT MODE
( 0 / ON , 1 / OFF ) : 1
ANIT-THEFT MODE
( 0 / ON , 1 / OFF ) : 0
Key in 23
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 23.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for push button
switch mode input.
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 2
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 1
PUSH BUTTON MODE
( 0 / ON , 1 / OFF ) : 0
Key in 24
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 24.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

17
Function (25) BEEP sound mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “ OFF “, the
BEEP sound will not function.
Function (26) Print mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 001) Once set at “ON”, stored data
can be printed out immediately.
Queuing for BEEP
sound mode input.
BEEP MODE
( 0 / ON , 1 / OFF ) : 2
BEEP MODE
( 0 / ON , 1 / OFF ) : 1
BEEP MODE
( 0 / ON , 1 / OFF ) : 0
Key in 25
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 25.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for
print mode input.
PRINT MODE
0 / ON , 1 / OFF ) : 2
PRINT MODE
( 0 / ON , 1 / OFF ) : 0
PRINT MODE
( 0 / ON , 1 / OFF ) : 1
Key in 26
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 26.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

18
Function (27) Anti-pass mode:
(0) shows “ ON”, (1) shows “OFF”. (pre-setting figure is 001) Once set at “ON”, the card
could only be used for matching single entry and exit. This is to prevent double entry by
using the same card if card has been duplicated.
Function (28) Display card number mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000). Once set at “OFF”, LCD will
not display the card number.
Queuing for anti-
pass mode input.
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 2
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 0
ANTI - PASS MODE
( 0 / ON , 1 / OFF ) : 1
Key in 27
Key in or
Esc system function selection.
Key in the or
Go into function 27.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
system password
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for display card
number mode input.
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 2
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 1
DISPLAY USER ID
( 0 / ON , 1 / OFF ) : 0
Key in 28
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 28.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.

19
Function (00) Instant door open:
Authorized personnel could get into the setup mode to open the door when any emergency
cases happened.
6. Reader installation instructions
(1)Reader connector
Note: (1) Door open relay electrical rating is 2A/24 VDC, 1A/120VAC
(2) Push button door open / door sensing / anti-theft sensing all are connection
terminal. Any other power supplying is not allowed.
(3) In order to avoid any disturbance of read range, user is advised to use two
separate adaptors.
Queuing for door
open input.
OPEN DOOR
YES => “ #“
Key in 00
Key in #or *
Esc system function selection
Press other key
Go into function 00
Key in the #
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
back to system function selection.
Setting successfully,
beep sound occurred.
Yellow
Purple
Blue
Green
Brown
Red
Purple
Blue
Green
Yellow
Orange
Brown
Black
Red
Push button door open joint terminal
Door open relay (Common) terminal
Door open relay (Normal Close) terminal
Door open relay (Normal Open) terminal
Signal (data) receiver
Signal (data) transmitter
Input power, negative GND
Input power,positive 12V
6 PIN CONNECTOR
8 PIN CONNECTOR
GND
Anti-duress output terminal (low active)
Alarm output point terminal (low active)
Door sensing terminal 2
Door sensing terminal 1
Anti theft sensing terminal (low active)
ST680 Wiring diagram
Yellow
Purple
Blue
Green
Brown
Red
Purple
Blue
Green
Yellow
Orange
Brown
Black
Red
Push button door open joint terminal
Door open relay (Common) terminal
Door open relay (Normal Close) terminal
Door open relay (Normal Open) terminal
Signal (data) receiver
Signal (data) transmitter
Input power, negative GND
Input power,positive 12V
6 PIN CONNECTOR
8 PIN CONNECTOR
GND
Anti-duress output terminal (low active)
Alarm output point terminal (low active)
Door sensing terminal 2
Door sensing terminal 1
Anti theft sensing terminal (low active)
ST680 Wiring diagram

20
(2) Wiring connection for additional electric lock and push button door
open switch.
As of different types of electric lock, the wiring methods are also different . Overall, there
are two types of wiring instructions as below:
(a) Fail secure :
(b) Fail safe :
Note: User must ensure the polarity (Diode) of the wiring connection for additional
electric lock is arranged correctly so that it is functional.
KA
Nude type
electrical lock
8 PIN Connector
R BK BR O Y G BL P
AEL
Push button switch
AP-10
DC12V AP-10
DC12V
Diode’s white color terminal
KA
Nude type
electrical lock
8 PIN Connector
R BK BR O Y G BL P
AEL
Push button switch
AP-10
DC12V AP-10
DC12V
Diode’s white color terminal
KA
Electro-Magnetic lock
AP-10
DC12V
AP-10
DC12V
Push button switch
Diode’s white color terminal
8 PIN Connector
R BK BR O Y G BL P
KA
Electro-Magnetic lock
AP-10
DC12V
AP-10
DC12V
Push button switch
Diode’s white color terminal
8 PIN Connector
R BK BR O Y G BL P
Table of contents