CONTENTS
Overview 4
Warnings and Precautions 6
Learn About Ozone 9
Your SoClean 3: Parts, Buttons & Indicator Lights 11
Setting Up Your SoClean 3 19
Powering Your SoClean 20
Installing the Filter 22
Wash, Rinse and Dry Your
Sleep Equipment Hose and Mask 24
Connecting the Adapter 26
Setup Checklist & Device Activation 28
Using Your SoClean 3 29
Operating a Maintenance Cycle 29
Using the Hose Sleeve 32
Setting a Delay for Your Maintenance Cycle 34
Fresh Air Cycle 36
Canceling a Cycle 37
Reconnecting Your Sleep Equipment 38
Maintenance 40
General Troubleshooting 42
Warranty Information 50

OVERVIEW
OVERVIEW
Indications for Use, Contraindications, and Specifications
CONTRAINDICATIONS FOR USE
Persons with underlying lung diseases, such as asthma and chronic obstructive pulmonary disease (also
known as COPD, which includes emphysema and chronic bronchitis), and those with cardiovascular
disease may be sensitive to ozone and should consult with their health care professional before using
this product.
CAUTION: Safety in pregnant or breastfeeding women and children under the age of 22 have not
been established. Consult with your health care professional before using this product.
Read this instruction manual before operating this device.
The SoClean 3 device should be used only according to the procedures described in this manual. If it
is used in a manner not specified by SoClean®
, the safety protection provided by the equipment may
be impaired.
INDICATIONS FOR USE
The SoClean 3 device is intended to be used to supplement maintenance procedures for home use
sleep equipment masks and hoses.
Ozone Cycle
75 minutes
Ozone Concentration
440 ppm maximum from ozone generator
Electromagnetic Compatibility
The SoClean 3 complies with all applicable
electromagnetic compatibility requirements (EMC)
according to IEC 60601-1-2:2014, for residential,
commercial, and light industry environments. If
electrical interference is suspected during operation,
contact SoClean Customer Care.
Sleep Equipment Hose
Dimensions Compatibility
For use with hose outside diameter dimensions
between 0.715 and 0.935 inches (18.15 and
23.75 mm) and lengths up to 6 feet 6 inches
(3.07 meters).
A 12 mm hose diameter will require a SoClean
Hose sleeve.
USB Port
This port is provided only for USB charging.
Maximum USB charging cord length: 10 ft. (3 m).
Model Number
SC1400
Operating Environmental Conditions
Indoor use only.
Temperature:50°F to 100°F (10°C to 38°C)
Relative Humidity: 15% to 75%
Altitude: sea level to 8,500’ (2,591 m);
Air Pressure Range 101.3 kPa to 73.8 kPa
Physical Characteristics
Dimensions: 9.49” x 7.12” x 7.36”
(241 x 181 x 187 mm)
Weight: 3.65 lbs. (1.65 kg)
Cord Length: 4’ 11” (1.5 m)
Electrical Characteristics
AC Adapter Input: AC 100~240V, 50/60HZ, 0.5A
AC Adapter Output: DC 12V, 1.5A Max
Power Consumption: 18W Max
USB Charging Port Output: DC 5V, 0.5 A Max
Storage and Transport Conditions
Temperature: -4°F to 131°F (-20°C to +55°C)
Humidity: 15% to 95% non-condensing humidity
Pressure: 106kPa to 70kPa
[Sea level to 10,000’ (3048m)]
SPECIFICATIONS
FCC Notice Part 15:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult SoClean Customer Care for help.
FCC CAUTION: Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
CAUTION: This equipment complies with FCC/IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. To maintain compliance with the FCC and IC RF exposure guidelines, place
the unit at least 20 cm away from nearby persons.
OZONE LEAKAGE
The SoClean 3 meets 21 C.F.R. § 801.415 for the maximum allowable ozone accumulation of not more than
0.05 parts per million when operated in a room larger than 70 square feet with 8-foot or higher ceilings.
OVERVIEW
DISPOSAL INFORMATION: Safe disposal of the device: Follow the local, state, and national governing
ordinances and recycling instructions regarding disposal or recycling of the device and device components
at the end of the expected service life.
No Liquid
in SoClean
Chamber
Do Not Use
If Package Is
Damaged
Storage and
Transport
Conditions
Consult
Manual
Waste Electrical and Electronic Equipment
(WEEE). It is the responsibility of the end user
to dispose of this equipment at a designated
collection point.
Date of
Manufacture
General
Caution/
Warning
Not Made With
Natural Rubber
Latex
Serial
Number
Federal
Communications
Commission
PACKAGING SYMBOLS
4 5

CAUTION: Do not place any flammable or ignitable items on top of the SoClean 3
device. Do not use in explosive air environments, near gas vapors, or other
flammables, etc.
CAUTION: Discontinue use of your SoClean 3, consult your health care professional,
and contact SoClean Customer Care if acne or a rash develops along the mask
contact line.
CAUTION: Ensure all tubing and hoses are free of kinks prior to operating the
SoClean 3.
CAUTION: Rest the flexible part of the sleep equipment hose, not the rigid mask
connector, in the Hose Slot to ensure a proper seal.
CAUTION: Inspect the SoClean 3 Lid and Hose Gaskets for visible damage before
operating a Maintenance Cycle.
CAUTION: Do not share a SoClean 3 between sleep equipment users. Your
SoClean 3 is to be used by one user.
CAUTION: In the event of loss of power, rerun the entire Maintenance Cycle to make sure
the sleep equipment hose and mask have been maintained properly.
CAUTION: Wash your sleep equipment mask and hose according to the sleep
equipment manufacturer’s recommended method and interval. Use the SoClean 3
for daily supplemental maintenance of your sleep equipment mask and hose.
CAUTION: Do not use incompatible materials in the SoClean 3 such as memory foam,
natural rubber, or nylon. Headgear often contains incompatible materials for your
SoClean 3. Remove headgear before placing mask in the Maintenance Chamber.
CAUTION: Ensure there are no obstructions to the filter exhaust. Keep the area behind
the SoClean 3 clear of clutter and soft objects.
WARNING: Discontinue use and call your health care professional in the event that
you experience any respiratory or cardiac symptoms.
WARNING: Keep away from children.
WARNING: When operating your SoClean 3 per the instructions for use, if there is a
noticeable scent of ozone or other unfamiliar odor or you experience headache,
cough, or shortness of breath, leave the room for 4 hours. Contact SoClean Customer
Care before running your machine again.
WARNING: The Ozone Tube must always be connected to the SoClean Adapter and the
back of the SoClean 3 unit when operating the SoClean.
WARNING: Do not inhale from the Ozone Tube or the Ozone Outlet on the back of
the device. Do not breathe through the mask if the SoClean 3 is operating a
Maintenance Cycle.
WARNING: Do not forcibly open the SoClean 3 Lid before the Cycle completes.
WARNING: Do not submerge the SoClean 3 device in water or use chemical cleaners
on or in your SoClean 3. Keep away from water sources, including rain, bathtubs,
sinks, and pools. To clean, wipe inside and outside with a damp cloth.
WARNING: Do not put liquids into the SoClean Chamber.
WARNING: Do not disassemble or modify your SoClean device or accessories.
WARNING: If the SoClean system is dropped, it may become damaged. Regularly
inspect the SoClean 3 for physical damage, such as cracks or broken structure,
damaged gaskets, and cracks in the Ozone Tube or sleep equipment hose. Discontinue
use if damage is detected and contact SoClean for assistance.
WARNING: To reduce the chance of tripping, place your sleep equipment and SoClean
along with all cords, tubes and hoses out of the way of any area you may walk.
Warnings
and Precautions
6 7

SoClean 3 uses ozone. Ozone is contained within the system and is in contact
with your sleep equipment hose and mask during the Maintenance Cycle.
SoClean 3 is designed to produce a sucient level of ozone for maintenance
of your sleep equipment hose and mask. The smell of ozone is detectable at
low concentrations by some people and you may smell ozone briefly during
the Maintenance Cycle.
Ozone naturally breaks down into oxygen in a short amount of time. Your
SoClean 3 safely contains ozone within the system until it has converted back
to oxygen. The Filter accelerates the process of converting ozone in your
SoClean 3 Chamber and your sleep equipment hose and mask into fresh air
before the completion of a Maintenance Cycle.
WARNING: When operating your SoClean 3 per the instructions for use, if
there is a noticeable scent of ozone or other unfamiliar odor or you experience
headache, cough, or shortness of breath, leave the room for 4 hours. Contact
SoClean Customer Care before running your machine again.
WARNING: If you are experiencing headaches/migraines, or symptoms such
as cough or discomfort in your nose or throat discontinue use and call your
health care provider.
WARNING: Discontinue use and call your health care provider if you
experience any cardiopulmonary symptoms.
WARNING: If the SoClean system is dropped, it may become damaged.
Regularly inspect the SoClean 3 for physical damage, such as cracks or
broken structure, damaged gaskets, and cracks in the Ozone Tube or sleep
equipment hose. Discontinue use if damage is detected and contact SoClean
for assistance.
CAUTION: Discontinue use of your SoClean 3, consult your health care
provider and contact SoClean Customer Care if acne or a rash develops along
the mask contact line.
Sleep equipment masks and hoses are made from a variety of materials.
SoClean has tested sleep equipment masks and hoses for material
compatibility with the ozone maintenance process.
While most sleep equipment masks and hoses are made of compatible
materials, the following materials should not be used with the SoClean 3:
memory foam, natural rubber, or nylon.
Sleep equipment mask and hose materials may discolor naturally over
time and with use, which is why the sleep equipment manufacturers
recommend replacing these components at regular intervals. The
SoClean 3 is safe to use with sleep equipment masks and hoses even if
you notice some discoloration.
CAUTION: Do not use incompatible materials in the SoClean 3 such
as memory foam, natural rubber, or nylon. Headgear often contains
incompatible materials for your SoClean 3. Remove headgear before
placing mask in the Maintenance Chamber.
MATERIAL COMPATIBILITY
How does my SoClean 3 Work?
Learn About Ozone
SLEEP EQUIPMENT HOSE COMPATIBILITY
For use with hose diameters of 15 mm and 19 mm and length up to 6’ 6”.
A 12 mm hose diameter will require a SoClean Hose sleeve [included].
Hose
Sleeve
Compatible
Masks and Hoses
8 9

HOSE SLOT
Your sleep equipment
hose rests here during
the Maintenance Cycle.
LID
Opens for access
to the Chamber.
CONTROL PANEL
Houses all the buttons
and icons for operating
your SoClean 3.
Your SoClean 3: Parts,
Buttons & Indicator Lights
WHAT’S INCLUDED
OZONE TUBE
SOCLEAN 3 DEVICE
FILTER
POWER SUPPLY
SOCLEAN ADAPTER
Compatible with most sleep
equipment hoses.
11

FILTER
The Filter converts ozone in your SoClean 3
and sleep equipment mask and hose into fresh
air as it exhausts from the unit. This component
must be replaced at least every 6 months. Your
SoClean 3 reminds you when it needs
replacement.
OZONE TUBE
One end of the Ozone Tube connects to your SoClean
Adapter, and the other end comes already attached to the
back of the SoClean 3. This tube is what circulates ozone or
air through your sleep equipment mask and hose during the
Maintenance Cycle and Fresh Air Cycle.
POWER INPUT
The cable from
the Power Supply
provided with your
SoClean 3 plugs
in here.
PHONE
CHARGING
PORT
A USB port is
provided on the back
of your SoClean 3 to
conveniently charge
your cell phone when
your SoClean 3 is
connected to power.
FILTER DOOR
Your Filter goes in here.
The SoClean 3 unit will
not operate a Maintenance
Cycle or Fresh Air Cycle
if the Filter Door is open.
YO U R S O C L E A N 3 : PA R T S & I C O N S
YO U R S O C L E A N 3 : PA R T S & I C O N S
LID LATCH
Keeps the Lid of the SoClean 3 closed
securely during the Maintenance Cycle
and Fresh Air Cycle.
LID GASKET
Seals the Lid in order
to contain ozone
within the Chamber.
HOSE DETECT
SENSOR
Your SoClean 3 will
only operate when
properly configured.
A Maintenance Cycle
or a Fresh Air Cycle
will not begin unless
a sleep equipment
hose is detected and
the Lid is closed.
MAINTENANCE
CHAMBER
Place your mask,
while still connected
to the hose, inside
the Chamber before
running a Maintenance
Cycle. The inside of the
Chamber is illuminated
for visibility in low-light
settings.
NOTE:
SoClean 3 Lid can only
be opened when the
device is plugged in.
12 13

YO U R S O C L E A N 3 : PA R T S , B U T TO N S & I C O N S
YO U R S O C L E A N 3 : PA R T S B U T TO N S & I C O N S
CONTROL PANEL
Get to know the buttons used to control the device operation and the icons
that will tell you what is happening.
A B C
D
A
MAINTENANCE CYCLE
Starts the maintenance process with a single push of the button.
Your mask and hose must be present in the SoClean 3 with the
Lid closed to operate the Maintenance Cycle.
C
FRESH AIR CYCLE
Runs air through the system to freshen your sleep equipment mask
and hose with the push of a button.
NOTE: The Fresh Air Cycle does not maintain your sleep equipment
mask and hose.
Your mask and hose must be present in the SoClean 3 with the
Lid closed to operate the Fresh Air Cycle.
BUTTONS
There are 4 buttons on the Control Panel that are used to operate your
SoClean 3. Buttons illuminate blue when any one button is pressed to help
with visibility in low-light conditions.
CYCLE DELAY
Used to set a 2, 4, or 8 hour delay to the start of your Maintenance Cycle.
NOTE: The system automatically returns to the default setting of
No Delay after each use.
B
LID OPEN
Opens the Lid when the device is connected to power. This button
can also be used to cancel an active Maintenance Cycle by pressing
and holding for 5 seconds.
NOTE: If canceling a Cycle, Lid cannot be opened until Cycle
Complete Icon illuminates.
D
There is no power button on your SoClean 3. The device is connected
to power and “on” when the Power Supply is plugged into your
SoClean 3 and the electrical outlet.
14 15

YO U R S O C L E A N 3 : PA R T S & I C O N S
YO U R S O C L E A N 3 : PA R T S & I C O N S
INDICATOR LIGHTS
There are 7 illuminated indicator lights on the Control Panel that the SoClean
3 uses to communicate with you. The icons are o if the device is idle and
operating normally. See the notes to follow about why these icons may
illuminate and when you can expect to see them.
ab c d e
f
g
Solid Green
Indicates that either a Maintenance Cycle or Fresh Air Cycle is
complete and that the Lid can be opened.
aCYCLE COMPLETE
Solid Red/Flashing Red
Indicates when your SoClean 3 has detected an internal issue.
See troubleshooting guide.
bFAULT/UNABLE TO RUN
Flashing Amber
Indicates that it is time to order a new Filter. From the time it
begins to flash amber, you have 30 days or 30 uses (whichever
comes first) to replace the Filter. You can still use your SoClean 3
to maintain your sleep equipment hose and mask during this time.
Solid Amber
See troubleshooting guide.
cFILTER ISSUE
FILTER DOOR ISSUE
d
Solid Amber
Indicates that the Filter Door is not completely closed.
Check your Filter Door and open/close it securely.
HOSE NOT DETECTED
e
Solid Amber
Indicates that your sleep equipment hose is not present or
detected when the Lid is closed.
Flashing Amber
Indicates an error detecting the hose or in process of detecting a
hose. This may be the first time the SoClean 3 has been powered
on or there has been loss of power to the device. Open and
close Lid with mask and hose installed to continue.
NOTE: Your SoClean 3 will not operate a Maintenance Cycle
or Fresh Air Cycle if your mask and hose are not installed or
detected in the unit with the Lid closed.
16 17

CYCLE PROGRESS BAR
g
Progressive Blue
Gradually turns blue from left to right as an indication of
progress for a Maintenance Cycle or Fresh Air Cycle.
Flashing Blue
A Cycle cancellation is in progress.
Solid Red
Indicates that an active Maintenance Cycle has been
interrupted (example: temporary loss of power).
NOTE: During this time, your SoClean 3 is pumping air
through the system to remove ozone.
2, 4, 8 HOUR CYCLE DELAY INDICATOR LIGHTS
f
Flashing Blue
Indicates that the Cycle Delay can be changed by pressing
the Cycle Delay button .
NOTE: Your mask and hose must be installed with the Lid closed
to modify and activate the Cycle Delay.
Solid Blue
Indicates if a Cycle Delay has been programmed.
Three indicator lights are provided.
One light illuminated = 2 hr delay selected
Two lights illuminated = 4 hr delay selected
Three lights illuminated = 8 hr delay selected
No lights illuminated = no cycle start delay selected (default)
YO U R S O C L E A N 3 : PA R T S & I C O N S
Setting Up
Your SoClean 3
18 19

Plug the Power Supply
into an electrical outlet
or power strip.
Plug the Power Supply
into the back of your
SoClean 3 as shown.
NOTE: Your SoClean 3 does not have a power switch to turn the device
on/o. When initially connected to power, the lights on your SoClean 3
will flash a pattern that you may not see if you are not looking at the
device immediately after it is connected to power. The SoClean 3 enters
a low-power “sleep” mode when not in use and fully powers when you
press any of the buttons on the Control Panel.
NOTE: The Filter Issue icon is
illuminated and the Hose Not
Detected icon is flashing on
your Control Panel because the
Filter is not yet installed and the
sleep equipment mask/hose has
not been placed into the
SoClean 3 with the Lid closed.
Power Supply
S E T T I N G U P Y O U R S O C L E A N 3
Locate your Power Supply
in the Welcome Kit as shown.
Remove the Power Supply
from the box.
A Power Supply is provided to safely power your SoClean 3. You will
need access to an electrical outlet near your SoClean 3 to power your
SoClean 3 in a well ventilated room.
POWERING YOUR SOCLEAN 3
Locate an electrical outlet near your SoClean 3 setup.
NOTE: It is okay to plug into a power strip, if needed.
S E T T I N G U P Y O U R S O C L E A N 3
WARNING: Avoid a tripping hazard.
B
C
A
Power
Supply
D
At this point in your SoClean 3 setup, your
Control Panel should appear as shown.
1
DO NOT place the power cord inside the device chamber.
The Lid will not open unless the device is powered.
20 21

INSTALLING THE FILTER
S E T T I N G U P Y O U R S O C L E A N 3 S E T T I N G U P Y O U R S O C L E A N 3
Insert the Filter into the slot
with the blue Rubber Gasket
facing inward as shown.
NOTE: The Hose Not Detected
icon is flashing on your Control
Panel because a mask/hose has
not been placed into the SoClean 3
with the Lid closed.
NOTE: If the Filter or Filter Door icon is flashing on your Control Panel,
remove and reinstall the Filter, making sure the filter door is fully closed.
Push the Filter Door until
it is fully closed.
Rubber
Gasket
The Filter converts ozone back to oxygen as it
leaves the SoClean 3 Chamber. With normal usage
of one Maintenance Cycle per day, the Filter needs
to be replaced approximately every 6 months or
when indicated by your device. To order a
replacement Filter, go to your authorized reseller
or SoClean.com. The following steps are used to
install the Filter in your SoClean 3.
Locate the Filter Door on
the back of your SoClean
unit and open it by pulling
the top edge of the Filter
Door away from the unit.
Locate and remove the
Filter from the box.
Filter
Door
At this point in your SoClean 3
setup, your Control Panel should
appear as shown.
B
A
Filter
C
D
2
22 23

S E T T I N G U P Y O U R S O C L E A N 3
WASHING YOUR SLEEP
EQUIPMENT HOSE AND MASK
Wash in Sink
Wash, rinse, and dry your hose and mask
as recommended by the manufacturer.
Your SoClean 3 should be used as a supplement
to your cleaning routine, not a replacement.
Washing removes oils, films, debris and other build up
that can naturally form on your mask and hose from use.
3Using the Hose and
Mask Adapter with
your SoClean 3
24 25
SoClean 3
Hose/Mask
Ozone Tube
SoClean
Adapter

Connecting
the Adapter
SoClean Adapter
Shown
connected to
popular sleep
equipment
hoses.
IMPORTANT: This adapter needs to fit snugly. If the fit appears too tight,
do not force adapter into tubing. If the adapter is loose, call Customer Care
at 866-501-3705.
Remove the hose
from your sleep
equipment.
Ozone Tube
1
SoClean
Adapter
Install the SoClean
Adapter onto the
hose.
2
Connect Ozone
Tube to the
SoClean Adapter.
Move on to
Device Activation.
3
WARNING: The Ozone Tube must always be
connected to the SoClean Adapter and the back of
the SoClean 3 unit when operating the SoClean 3.
26 27

Complete the steps below in order to use your SoClean 3
SoClean is powered on (page 20)
Filter is installed (page 22)
Sleep equipment hose and mask are washed in sink and
dried before first use (page 24)
SoClean Adapter is installed on sleep equipment hose
Ensure the Ozone Tube is connected to the back of the
SoClean 3 and the SoClean Adapter
Sleep equipment hose is still connected to mask
ONE-TIME DEVICE ACTIVATION: The Lid must be closed
and the mask and hose outside the Chamber. Firmly press
the Control Panel buttons in the following order:
If the Cycle Complete icon is green ,
your device is ready to use.
If the activation was unsuccessful, press the Lid Open button
to open the Lid. Close Lid. Restart DEVICE ACTIVATION.
The SoClean 3 can be used daily to supplement your manufacturer
recommended hose and mask cleaning routine.
Wait a minimum of 30 minutes between completion of the Cycle and use
of the sleep equipment mask and hose.
Press the Lid Open button to open the Lid.
Ensure your SoClean 3 is ready for use by completing the steps on
the setup checklist.
STOP: ensure you are following your manufacturer’s
recommendation to properly wash and dry your sleep equipment
hose and mask before first use of SoClean 3 and as part of your
ongoing cleaning routine (page 24).
OPERATING A
MAINTENANCE CYCLE
WARNING: The Ozone Tube must always be
connected to the SoClean Adapter and the back of
the SoClean 3 unit when operating the SoClean 3.
A
B
1
Setup Checklist &
Device Activation
Using Your SoClean 3
Once you have completed the setup steps, you are ready to begin the daily
maintenance of your sleep equipment mask and hose with your SoClean 3.
NOTE: The Lid will
spring open and
light will illuminate
from the inside of
the bottom of the
Chamber.
28 29

To run the Maintenance
Cycle immediately, press the
Maintenance Cycle button
to start.
You should hear the ozone
generator and air pump turning on
and o periodically over the 1 hour
and 15 minute Maintenance Cycle.
Make sure the sleep equipment
hose is connected to the SoClean
Adapter and the Ozone Tube is
properly connected to the Adapter
and to the back of the SoClean 3.
Place your mask into the Chamber
and route the mask hose through
the Hose Slot.
NOTE: Some head gear contains nylon which is not compatible with ozone.
It is recommended to remove head gear before placing the mask into the
Chamber.
CAUTION: In the event of loss of power to your home or the SoClean 3
device during a maintenance cycle, you may want to rerun the entire
Maintenance Cycle to make sure your sleep equipment hose and mask
have been properly maintained.
IMPORTANT: The SoClean 3 device will not operate without the mask and
hose present in the securely closed Chamber. Additionally, the SoClean 3
will not operate if the Filter is not present with the Filter Door closed.
C
D
Push the Lid down until it latches shut.
CAUTION: Rest the flexible part
of the hose, not the rigid mask
connector, in the Hose Slot to
ensure a proper seal.
CAUTION: Ensure all tubing and
hoses are free of kinks prior to
operating the SoClean 3.
The Maintenance Cycle button
will illuminate blue to indicate
the Maintenance Cycle is operating.
The Progress Bar on the Control
Panel will illuminate blue from left
to right as the cycle proceeds to
completion.
U S I N G YO U R S O C L E A N 3U S I N G YO U R S O C L E A N 3
At the end of the
Maintenance Cycle,
the Cycle Complete icon
will light up green.
You can now press the
Lid Open button to
remove your mask and
hose. Wait a minimum
of 30 minutes between
completion of the Cycle
and use of the sleep
equipment mask and hose.
E
NOTE: It is important to leave your mask and hose in the SoClean 3 for
the complete Cycle duration to ensure full maintenance of your sleep
equipment mask and hose. Leave the room for the duration of the Cycle.
The SoClean will operate the air pump and circulating fan for the last 12
minutes of the Cycle duration to move fresh air through the system.
Your sleep equipment mask and hose are ready for use!
If you need to remove your sleep equipment mask and hose before
the Maintenance Cycle is complete, see the “Canceling a Cycle” section.
See Step 2 if your hose requires a Hose Sleeve.
30 31

If there is visible space around
the hose when placed in the
hose slot, you may be using a
12 mm hose and require the
Hose Sleeve be installed.
The Hose Sleeve is required if you use a 12 mm hose.
It is not compatible with 15 mm or larger diameter hoses.
An extra sleeve is included in the event of sleeve breakage.
You will only use one Hose Sleeve at a time.
2 to 3 inches
Position the Hose Sleeve
2 to 3 inches from the
connector.
Line up the Hose Sleeve
with the gasket, place
it in the Hose Slot and
shut the lid.
Position the hose on the
Nub side of the Hose
Sleeve. Slide the hose
until the Sleeve “clicks”
into place between two
of the hose ribs and
close the Sleeve.
A
C
B
The images below are actual size and can be used to determine
which hose you have.
USING THE HOSE SLEEVE
[OPTIONAL]
The SoClean requires a snug fit around the hose when placed into
the hose slot and the lid is closed. If there is space around the
hose and this is not achieved, the SoClean will not operate.
2
19 mm
Hose 15 mm
Hose 12 mm
Hose
32

The Cycle Delay time is selected by pressing the Cycle Delay
button until the desired number of lights are lit, as indicated by
the blue indicator lights above the Cycle Delay button and
then pressing the Maintenance Cycle button to confirm the
setting. If you’ve gone past the correct number of lights, continue to
press the Cycle Delay button until the desired delay is set.
Allow approximately 1 second between button presses when
selecting the Cycle Delay. The delay timer will start immediately
after pressing the Maintenance Cycle button .
NOTE: If the Maintenance Cycle button is not pushed within
10 seconds of the last Cycle Delay button press, the Cycle Delay
setting will time out and a delayed Maintenance Cycle will not occur.
U S I N G YO U R S O C L E A N 3
PRESS INDICATION DELAY
1 time 1 blue indicator 2-hour
2 times 2 blue indicators 4-hour
3 times 3 blue indicators 8-hour
4 times No blue indicator No delay
No delay (default)
2-hr delay selected
4-hr delay selected
8-hr delay selected
When your mask, hose, and
filter are properly installed
and the Lid is closed, all three
buttons will briefly light up solid
blue. Press the Cycle Delay
button to select the delay
time. The Cycle Delay button
will flash blue for a few
seconds during which time the
Cycle Delay can be changed.
SETTING A DELAY FOR YOUR
MAINTENANCE CYCLE
If you would like the SoClean 3 to operate at a more convenient time, you
can delay your Maintenance Cycle by 2, 4, or 8 hours.
NOTE: Your mask and hose must be
in your SoClean 3 with the Lid closed
to select or adjust a Cycle Delay.
During the delay period, the Cycle
Delay indicator lights above the
button will illuminate blue until the
Maintenance Cycle starts.
Once the selected Cycle Delay time
has elapsed, the Maintenance Cycle
will automatically begin. Leave the
room for the duration of the Cycle.
To cancel the Cycle Delay after
it’s set, simply open the lid.
At the end of the Cycle Delay
and Maintenance Cycle, the
Cycle Complete icon will
light up green. You can now
open the Lid and remove your
mask and hose.
Wait a minimum of 30 minutes
between completion of the
Cycle and use of the sleep
equipment mask and hose.
C
A
B
U S I N G YO U R S O C L E A N 3
NOTE: The system automatically returns to the default setting of No Delay
after each use. If power is lost during a delayed cycle it will be canceled.
3
34 35

U S I N G YO U R S O C L E A N 3
At the end of the Fresh Air Cycle, the
Cycle Complete icon will light up
green. You can now open the Lid and
remove your mask and hose.
NOTE: You can run only 3 consecutive
Fresh Air Cycles before you must run a
Maintenance Cycle. This ensures that
your sleep equipment mask and hose
are properly maintained.
B
FRESH AIR CYCLE
[OPTIONAL]
The Fresh Air Cycle can be used daily to freshen the air in your mask
and hose before use. Typically, your mask and hose will still be in
your SoClean 3 from a Maintenance Cycle and the Fresh Air Cycle
can be started with a simple one-button push. The Fresh Air Cycle
does not maintain your sleep equipment mask and hose.
Place your mask and hose in your
SoClean 3 and press the Fresh
Air Cycle button to initiate the
process.
The Fresh Air Cycle will take
approximately 5 minutes to
complete. During the Fresh Air
Cycle, the Fresh Air Cycle button
will illuminate blue to indicate
the Fresh Air Cycle is operating. The
Progress Bar on the Control Panel
will progressively illuminate blue as
the cycle proceeds to completion.
NOTE: Running a Fresh Air Cycle
does not reduce the life of the Filter.
A
U S I N G YO U R S O C L E A N 3
CANCELING A CYCLE
If you need to remove your sleep equipment mask and hose while an
active Maintenance Cycle is taking place, you can cancel the cycle.
Press and hold the Lid Open button
for approximately 5 Seconds.
The SoClean 3 will pump air through the
system for approximately 15 minutes after
the Maintenance Cycle is canceled in order
to clear ozone from your sleep equipment
mask and hose.
At the end of the Maintenance Cycle
cancellation, the Cycle Complete icon
will light up green. The Maintenance Cycle
was successfully canceled. You can now
press the Lid Open button and remove
your mask. Wait a minimum of 30 minutes
between completion of the Cycle and use
of the sleep equipment mask and hose.
Your sleep equipment mask and hose
may not have been fully maintained.
WARNING: Do not forcibly open the
SoClean 3 Lid before the Cycle completes.
While the Maintenance Cycle cancellation
is in progress, the following will illuminate:
• Fault/Unable to Run icon will
flash red for nine seconds.
• Maintenance Cycle button will
illuminate blue
• Progress Bar on the Control Panel
will flash blue
The Lid will remain locked until the
cancellation is complete.
A
B
4 5
3736

F I LT E R R E P L AC E M E N T L O G
Once the Maintenance Cycle is complete and
you are ready to use your sleep equipment
hose and mask, wait a minimum of 30 minutes
between completion of the Cycle and use of the
sleep equipment mask and hose.
SoClean
Adapter
Reconnecting Your
Sleep Equipment
Remove the SoClean
Adapter from your
hose.
1
Reconnect your hose
to the sleep equipment
hose port.
2
38
Other manuals for 3
1
Table of contents
Other SoClean Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Remington
Remington All Shot! SB-1010 Use and care guide

BIOLUX RESEARCH
BIOLUX RESEARCH OrthoPulse user guide

Imetec
Imetec R7609 Instructions for use

DURAVIT
DURAVIT LM 7805 installation instructions

DJO
DJO DONJOY ULTRASLING PRO AB Clinician Application Instructions

Kerbl
Kerbl constanta4 18990 Instructions for use

microbeau
microbeau Spektra Xion S user manual

aidapt
aidapt VM929 Usage and maintenance instructions

Lanaform
Lanaform 97302830 user manual

Bellus Medical
Bellus Medical SkinPen user manual

NRS Healthcare
NRS Healthcare Rise Easy G21808 User instructions

Basko Healthcare
Basko Healthcare Stomacare EasyCut Instructions for use