Softel SFT3542HA User manual

SFT3542HA
Encoder Modulator User Manual

About This Manual
Intended Audience
This user manual has been written to help people who have to use, to integrate and to
install the product. Some chapters require some prerequisite knowledge in electronics
and especially in broadcast technologies and standards.
Disclaimer
No part of this document may be reproduced in any form without the written permission
of the copyright owner.
The contents of this document are subject to revision without notice due to continued
progress in methodology, design and manufacturing. SOFTEL shall have no liability for
any error or damage of any kind resulting from the use of this document.
Copy Warning
This document includes some confidential information. Its usage is limited to the
owners of the product that it is relevant to. It cannot be copied, modified, or translated
in another language without prior written authorization from SOFTEL.

SFT3542HA Encoder Modulator User Manual
Directory
CHAPTER 1 INTRODUCTION.......................................................................................................................... 1
1.1 PRODUCT OVERVIEW................................................................................................................................ 1
1.2 KEY FEATURES......................................................................................................................................... 1
1.3 SPECIFICATIONS........................................................................................................................................ 1
1.4 PRINCIPLE CHART.....................................................................................................................................3
1.5 APPEARANCE AND DESCRIPTION.............................................................................................................. 3
CHAPTER 2 INSTALLATION GUIDE................................................................................................................. 5
2.1 GENERAL PRECAUTIONS...........................................................................................................................5
2.2 POWER PRECAUTIONS............................................................................................................................... 5
2.3 DEVICE’SINSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING.................................................... 5
2.4 ENVIRONMENT REQUIREMENT................................................................................................................. 5
2.5 GROUNDING REQUIREMENT..................................................................................................................... 6
CHAPTER 3 WEB NMS OPERATION............................................................................................................... 7
3.1 LOGIN........................................................................................................................................................7
3.2 OPERATION............................................................................................................................................... 7
CHAPTER 4 TROUBLESHOOTING................................................................................................................. 21
CHAPTER 5 PACKING LIST............................................................................................................................ 22


-16
SOFTEL Corp. Ltd Page 1 / 26
SFT3542HA Encoder Modulator User Manual
Chapter 1 Introduction
1.1 Product Overview
SFT3542HA SD encoder modulator is a professional high integration device which
includes encoding, multiplexing, scrambling and modulation. It supports 8 to 24 CVBS
inputs, one DVB-C tuner input and 128 IP input with Data1 (GE) and Data2 (FE) port. It
also supports DVB-C RF out with 4 adjacent carries, and supports Data1 (GE) output
port to support 4 MPTS out. This full function device makes it ideal for small CATV
head end system, and it’s a smart choice for hotel TV system, entertainment system in
sports bar, hospital, apartment…
1.2 Key Features
8/12/16/20/24 A/V inputs with MPEG2 Encoding
MPEG1 Layer II, AC3(2.0) Audio encoding and support audio gain adjustment
1DVB-C tuner input for re-mux (only for DVB-C RF out version. Suitable for India
market.)
128 IP input over UDP and RTP protocol
4 groups of multiplexing/scrambling/modulation output channels
Support PID remapping/ accurate PCR adjusting/PSI/SI editing and inserting
Support 4 MPTS IP (DATA1 port only) output over UDP and RTP
Support 4 DVB-C RF out
Support CC (closed caption)
Support QR code, LOGO, OSD insertion
Control via web management, and easy updates via web
Lowest cost per channel, breakthrough price

Page 2 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
1.3 Specifications
Input
8/12/16/20/24 CVBS inputs , RCA interface ,
1 DVB-C Tuner for remux, F type interface (only for DVB-C RF out)
128 IP input over UDP and RTP, DATA1 and DATA2,RJ45
Video
Resolution
720×480_60i, 544×480_60i, 352×480_60i
352×240_60i,320×240_60i,176×240_60i, 176×120_60i
720×576_50i,704×576_50i,640×576_50i, 352×288_50i
320×288_50i, 176×288_50i, 176×144_50i
Encoding
MPEG-2
Bit-rate
0.5Mbps~8Mbps each channel
Rate Control
CBR, VBR
GOP Structure
GOP_0_B, GOP_1_B, GOP_2_B, GOP_3_B
Advanced
Pretreatment
De-interlacing, noise reduction
Aspect Ration
4:3, 16:9
Audio
Encoding
MPEG-1 Layer 2, AC3 (2.0)
Sampling rate
48KHz
Resolution
24-bit
Bit-rate
64Kbps,128Kbps,192kbps,256kbps,320kbps,384kbps each
channel
Multiplexing
Maximum PID
Remapping
180 input per channel
Function
PID remapping ( automatically or manually)
Accurate PCR adjusting
Generate PSI/ SI table automatically
Scrambling
(Only for DVB-C
RF out)
Maximum
simulcrypt CA
4
Standard
ETR289, ETSI 101 197, ETSI 103 197
Connection
Local/remote connection
Modulation
DVB-C
RF out
4*RF DVB-C out
Standard
EN300 429/ITU-T J.83A/B
MER
≥40db
RF frequency
50~960MHz, 1KHz step
RF output level
-25 ~ -1dbm (82~106 dbµV), 0.1db step
Symbol Rate
5.0Msps~7.0Msps, 1ksps stepping
Constellation
16/32/64/128/256QAM
Constellation
J.83A
J.83B
16/32/64/128/256QAM
64/256 QAM
Bandwidth
8M
6M
Stream output
RF output (F type interface)

-16
SOFTEL Corp. Ltd Page 3 / 26
SFT3542HA Encoder Modulator User Manual
4 IP MPTS output over UDP/RTP, 1*1000M Base-T Ethernet interface
System function
Network management (WEB)
English language
Ethernet software upgrade
Miscellaneous
Dimension (W×L×H)
482mm×410mm×44mm
Environment
0~45℃(work);-20~80℃(Storage)
Power requirements
AC 110V± 10%, 50/60Hz, AC 220 ± 10%, 50/60Hz
1.4 Principle Chart
1.5 Appearance and Description
Front and Rear Panel Illustration
1
RF test and RF out port

Page 4 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
2
Port Power supply and Grounding Pole
3
24 CVBS input( DB9 to RCA)
4
Reset Key:Reset webmaster IP address, recover it to default IP address
5
Indicators
6
Data1: IP input and output port(GE)
Data2: IP input port(FE)
7
NMS (Network management port)
8
RF in and Loop out (for DVB-C tuner input)

-16
SOFTEL Corp. Ltd Page 5 / 26
SFT3542HA Encoder Modulator User Manual
Chapter 2 Installation Guide
This section is to explain the cautions the users must know in some case that possible injure
may bring to users when it’s used or installed. For this reason, please read all details here
and make in mind before installing or using the product.
2.1 General Precautions
Must be operated and maintained free of dust or dirty.
The cover should be securely fastened, do not open the cover of the products when the
power is on.
After use, securely stow away all loose cables, external antenna, and others.
2.2 Power precautions
When you connect the power source, make sure if it may cause overload.
Avoid operating on a wet floor in the open. Make sure the extension cable is in good
condition
Make sure the power switch is off before you start to install the device
2.3 Device’s Installation Flow Chart Illustrated as following
2.4 Environment Requirement
Item
Requirement
Machine Hall
Space
When user installs machine frame array in one machine hall,
the distance between 2 rows of machine frames should be

Page 6 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
1.2~1.5m and the distance against wall should be no less than
0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level
glasses for window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires
AC 110V±10%, 50/60Hz or AC 220V±10%, 50/60Hz. Please
carefully check before running.
2.5 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of devices. Also,
they are the most important guarantee of lightning arresting and interference rejection. Therefore,
the system must follow this rule.
Grounding conductor must adopt copper conductor in order to reduce high frequency impedance,
and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no less
than 25 mm2.

-16
SOFTEL Corp. Ltd Page 7 / 26
SFT3542HA Encoder Modulator User Manual
Chapter 3 WEB NMS Operation
User can only control and set the configuration in computer by connecting the device to web
NMS Port. User should ensure that the computer’s IP address is different from this device’s IP
address; otherwise, it would cause IP conflict.
3.1 Login
The default IP address of this device is 192.168.0.136.
Connect the PC (Personal Computer) and the device with net cable, and use ping command to
confirm they are on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx
can be 1 to 254 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder & Modulator’s IP
address in the browser’s address bar and press Enter.
It displays the Login interface as Figure-1. Input the Username and Password (Both the default
Username and Password are “admin”.) and then click “LOGIN” to start the device setting.
Figure-1
3.2 Operation
Summary →Status
When we login into encoder module, it displays the status interface as Figure-2.

Page 8 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
Figure-2
Parameters →Module 1-3
SFT3542HA supports up to 6 modules with 24CVBS input. From the menu on left side of the
webpage, clicking “Module1-3, it displays the information of each encoding channel of the 3
modules as Figure-3.
General settings for
the Encoding program:
User can edit any item
listed as needed.
The light will turn green if there is
source inputting from module.
User can click any item here to enter
the corresponding interface to check
information or set the parameters.
System information

-16
SOFTEL Corp. Ltd Page 9 / 26
SFT3542HA Encoder Modulator User Manual
Figure-3
Parameters →Tuner:
Clicking “Tuner”, it displays the interface as Figure-4 about tuner input information. When
users click “Edit” button, it triggers a dialog box where users can set DVB-C tuner input
parameters.
Figure-4
Parameters →TS Config:
From the menu on left side of the webpage, clicking “TS Config”, it displays the interface
where users can configure the TS output parameters.
TS Config→Output TS X:
Clicking “Output TS X”, it displays the interface where users can select the 4 TS output carrier.
(Figure-5)

Page 10 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
Figure-5
TS Config→Stream select:
Clicking “Stream select”, it displays the interface where users can select program(s) to
multiplex out and modify program info. (Figure-6)
Figure-6
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as
Input Area
Output Area
Operation Area

-16
SOFTEL Corp. Ltd Page 11 / 26
SFT3542HA Encoder Modulator User Manual
below:
: To add input channel which come from GE1/GE2/Tuner
: To edit the input channel
: To delete the input channel
: To delete all inputs channel
: To check input IP lock or not, green means current IP locked
: To check current TS overflow or not, red color means current TS overflow,
need reduce program
: To filter/not filter the source CA information
: To enable/disable the PID remapping
To refresh the input program information
To refresh the output program information
Select one input program first and click this button to transfer the selected program
to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
To parse programs time limitation of parsing input programs
Program Modification:
The multiplexed program information can be modified by clicking the program in the ‘output’
area. For example, when clicking , it triggers a dialog box (Figure-7) where
users can input new information.
Figure-7
TS Config→General:

Page 12 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
From the TS Config menu on up side of the webpage, clicking “General”, it displays the
interface where users can set output mode, enable PSI/SI table out, NIT insert/VCT insert, PCR
correction. (Figure-8)
Figure-8
TS Config→PID Bypass:
From the TS Config menu on up side of the webpage, clicking “PID Bypass”, it displays the
interface as Figure-9 where user can add PIDs to be passed, click the “+” symbol, input current
IP channel number, then input current IP source Pid and output Pid which is customer needed ,
then click “set”
Figure-9

-16
SOFTEL Corp. Ltd Page 13 / 26
SFT3542HA Encoder Modulator User Manual
Parameters →Scrambler:
Clicking “Scrambler”, it displays the interface as Figure-10 where user can configure parameters
to scramble the programs. “Scr CH1-4” is corresponding to “Output TS1-4” respectively.
Figure-10
Parameters →Modulator:
Clicking “Modulator”, it displays the Modulator Configuration screen as Figure-11.
NDS3542H supports 4 DVB-C RF out. Here user can set modulation parameters.
Figure-11
Figure-11
Quickly Config
Channel Config

Page 14 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
When users click “quickly config” button, it triggers a dialog box (Figure -12) where users can
set all channels configration.
Figure-12
When users click “Channel config” button, it triggers a dialog box (Figure -13) where users can
set the corresponding channel configration.
Figure-13
Parameters →IP Stream:
SFT3542HA supports 4 TS to output in IP format through the DATA1 port.
Clicking “IP Stream”, it displays the interface where to set IP out parameters (Figure-14).

-16
SOFTEL Corp. Ltd Page 15 / 26
SFT3542HA Encoder Modulator User Manual
Figure-14
When users click “quickly config” button, it triggers a dialog box (Figure-15) where users can
set all channels configration.
Figure-15
When users click “Channel config” button, it triggers a dialog box (Figure-16) where users can
set the corresponding channel configration.
Figure-16
Parameters →OSD:
Clicking “OSD”, it displays the interface as Figure-17/18/19 where to set Logo/ Caption/ QRCode
parameters.
Quickly Config
Channel Config

Page 16 / 26 SOFTEL Corp. Ltd.
SFT3542HA Encoder Modulator User Manual
Figure-17
Figure-18
Enter your text
here
Select the text color and
background color
Browse and select
the QRcode which
has been created
Put your QRcode URL
here
Select one channel or
all channels to set
parameters
Point to the Logo/Caption/QRCode and
click the right mouse button to set
Logo/Caption/QRCode parameters. Users
can move Logo/Caption/QRCode on the
screen.
Browse and upload the
LOGO, then click “Add” to
apply it
There are 3 channels which users can
chose to apply Logo/Caption/QRCode.
Select “on”, the logo/Caption/QRCode
will display on the screen.
Click “Date” to set the
show time and date of
logo/Caption/QRCode
Table of contents
Other Softel Modulator manuals