Softel SFT3542H User manual

SFT3542H
Encoder Modulator User Manual

About This Manual
Intended Audience
This user manual has been written to help people who have to use, to integrate and to
install the product. Some chapters require some prerequisite knowledge in electronics
and especially in broadcast technologies and standards.
Disclaimer
No part of this document may be reproduced in any form without the written permission
of the copyright owner.
The contents of this document are subject to revision without notice due to continued
progress in methodology, design and manufacturing. SOFTEL shall have no liability for
any error or damage of any kind resulting from the use of this document.
Copy Warning
This document includes some confidential information. Its usage is limited to the
owners of the product that it is relevant to. It cannot be copied, modified, or translated
in another language without prior written authorization from SOFTEL.

SFT3542H Encoder Modulator User Manual
Directory
CHAPTER 1 INTRODUCTION.......................................................................................................................... 1
1.1 PRODUCT OVERVIEW................................................................................................................................ 1
1.2 KEY FEATURES......................................................................................................................................... 1
1.3 SPECIFICATIONS........................................................................................................................................ 2
1.4 PRINCIPLE CHART.....................................................................................................................................3
CHAPTER 2 INSTALLATION GUIDE................................................................................................................. 6
2.1 GENERAL PRECAUTIONS...........................................................................................................................6
2.2 POWER PRECAUTIONS............................................................................................................................... 6
2.3 DEVICE’SINSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING.................................................... 6
2.4 ENVIRONMENT REQUIREMENT................................................................................................................. 6
2.5 GROUNDING REQUIREMENT..................................................................................................................... 7
CHAPTER 3 WEB NMS OPERATION............................................................................................................... 8
3.1 ENCODER LOGIN....................................................................................................................................... 8
3.2 ENCODER MODULATOR OPERATION......................................................................................................... 8
CHAPTER 4 TROUBLESHOOTING................................................................................................................. 25
CHAPTER 5 PACKING LIST............................................................................................................................ 26


Page 1 / 30
SFT3542H Encoder Modulator User Manual
Chapter 1 Introduction
1.1 Product Overview
SFT3542H24 in 1 encoder modulator is SOFTEL’s newest devices which integrate
encoding, multiplexing, scrambling and DVB-C/T modulation. It supports 24 CVBS
input, one DVB-C tuner input and 128 IP input with Data1 (GE) and Data2 (FE) port.
It also support DVB-C/T RF out with 4 adjacent carries (50MHz~960MHz), and
support Data1 (GE) output port to support 4 MPTS out. This full function device
makes it ideal for small CATV head end system, and it’s a smart choice for hotel TV
system, entertainment system in sports bar, hospital, apartment…
1.2 Key Features
24 A/V inputs with MPEG2 encoding, 1DVB-C tuner input
128 IP input over UDP and RTP protocol
MPEG1 Layer II, AC3(2.0) Audio encoding and support audio gain adjustment
4 groups multiplexing, 4 groups scrambling and 4 DVB-C RF carriers out
4 groups multiplexing and 4 DVB-T RF carriers out (Optional)
Support IP (MPTS only, DATA1 port only) output over UDP and RTP
Support “Null PKT Filter” function
Excellent RF output performance index, MER≥40dB
Support PID remapping
Support accurate PCR adjusting
Support PSI/SI editing and inserting
Control via web management, and easy updates via web
Lowest cost per channel, breakthrough price

Page 2 / 30
SFT3542H Encoder Modulator User Manual
1.3 Specifications
Input
24 CVBS inputs , RCA interface ,
1 DVB-C Tuner, F type interface
128 IP input over UDP and RTP, DATA1 and DATA2,RJ45
Video
Resolution
720×480_60i, 544×480_60i, 352×480_60i
352×240_60i,320×240_60i,176×240_60i, 176×120_60i
720×576_50i,704×576_50i,640×576_50i, 352×288_50i
320×288_50i, 176×288_50i, 176×144_50i
Encoding
MPEG-2
Bit-rate
0.5Mbps~8Mbps each channel
Rate Control
CBR,VBR
GOP Structure
IBBP
Advanced
Pretreatment
De-interlacing, noise reduction
Audio
Encoding
MPEG-1 Layer 2, AC3 (2.0)
Sampling rate
48KHz
Resolution
24-bit
Bit-rate
64Kbps,128Kbps,192kbps,256kbps,320kbps,384kbps
each channel
Multiplexing
Maximum PID
Remapping
180 input per channel
Function
PID remapping ( automatically or manually)
Accurate PCR adjusting
Generate PSI/ SI table automatically
Scrambling
Maximum
simulcrypt CA
4
Standard
EN300 429/ITU-T J.83A/B
Connection
Local/remote connection
Modulation
DVB-C
QAM Channel: 4
Standard: EN300 429/ITU-T J.83A/B
MER: ≥40db
RF frequency: 50~960MHz, 1KHz step
RF output level: -20~0dbm (87~107 dbµV), 0.1db step
Symbol Rate: 5.0Msps~7.0Msps, 1ksps stepping
Constellation: 16/32/64/128/256QAM
J.83A
J.83B
Constellation
16/32/64/128/256QAM
64/256 QAM
Bandwidth
8M
6M
DVB-T
Standard
EN300744
FFT mode
2K,

Page 3 / 30
SFT3542H Encoder Modulator User Manual
Bandwidth
6M, 7M, 8M
Constellation
QPSK, 16QAM, 64QAM
Guard
Interval
1/4, 1/8, 1/16, 1/32
FEC
1/2, 2/3, 3/4, 5/6, 7/8
MER
≥42 dB
RF frequency
50~960MHz, 1KHz step
RF out
4*RF COFDM DVB-T out (4 carriers
combined output)
RF output
level
-28~ -3 dBm (77~97 dbµV), 0.1db step
Standard
EN300744
Stream
output
RF output (F type interface)
4 IP output over UDP/RTP
1*1000M and 1*100M Base-T Ethernet interface
System
function
Network management(WEB)
Chinese and English language
Ethernet software upgrade
Miscellaneous
Dimension(W×L×H)
482mm×410mm×44mm
Approx weight
8kg
Environment
0~45℃(work);-20~80℃(Storage)
Power requirements
AC 110V± 10%, 50/60Hz, AC 220 ± 10%,
50/60Hz
Power consumption
20W
1.4 Principle Chart
DVB-C RF output

Page 4 / 30
SFT3542H Encoder Modulator User Manual
DVB-T RF output
1.5 Appearance and Description
Front and Rear Panel Illustration

Page 5 / 30
SFT3542H Encoder Modulator User Manual
1
RF test and RF out port
2
Port Power supply and Grounding Pole
3
24CVBS input( DB9 to RCA)
4
Reset Key/Data Port Indicator
5
Indicator
6
DATA Port (for IP stream input/output)
7
NMS/CAS
8
RF in and Loop out port

Page 6 / 30
SFT3542H Encoder Modulator User Manual
Chapter 2 Installation Guide
This section is to explain the cautions the users must know in some case that possible
injure may bring to users when it’s used or installed. For this reason, please read all
details here and make in mind before installing or using the product.
2.1 General Precautions
Must be operated and maintained free of dust or dirty.
The cover should be securely fastened, do not open the cover of the products when the
power is on.
After use, securely stow away all loose cables, external antenna, and others.
2.2 Power precautions
When you connect the power source, make sure if it may cause overload.
Avoid operating on a wet floor in the open. Make sure the extension cable is in good
condition
Make sure the power switch is off before you start to install the device
2.3 Device’s Installation Flow Chart Illustrated as following
2.4 Environment Requirement
Item
Requirement
Machine Hall
Space
When user installs machine frame array in one machine hall,
the distance between 2 rows of machine frames should be

Page 7 / 30
SFT3542H Encoder Modulator User Manual
1.2~1.5m and the distance against wall should be no less than
0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level
glasses for window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires
AC 110V±10%, 50/60Hz or AC 220V±10%, 50/60Hz. Please
carefully check before running.
2.5 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of devices.
Also, they are the most important guarantee of lightning arresting and interference
rejection. Therefore, the system must follow this rule.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no
less than 25 mm2.

Page 8 / 30
SFT3542H Encoder Modulator User Manual
Chapter 3 WEB NMS Operation
3.1 Encoder login
The default IP address of this device is 192.168.0.136. Connect the PC (Personal
Computer) and the device with net cable, and use ping command to confirm they are
on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to
192.168.99.xxx (xxx can be 1 to 254 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder &
Modulator’s IP address in the browser’s address bar and press Enter.
It will display the Login interface as Figure-1. Input the Username and Password
(Both the default Username and Password are “admin”.) and then click “LOGIN” to
start the device setting.
Figure-1
3.2 Encoder Modulator Operation
Status
When we login into encoder module, it displays the status interface as Figure-2.

Page 9 / 30
SFT3542H Encoder Modulator User Manual
Figure-2
Parameters →Module 1-6
NDS3542H-24 support up to 6 modules with 24 CVBS input. From the menu on left side
of the webpage, clicking “Module1-6”, it displays the information of each encoding
channel as Figure-3.
User can click any item here to enter
the corresponding interface to check
information or set the parameters.
Current software version
information

Page 10 / 30
SFT3542H Encoder Modulator User Manual
Figure-3
Parameters →Tuner:
From the menu on left side of the webpage, clicking “Tuner”, it displays the interface
where users can configure the Tuner input parameters as Figure-4.
General settings for
the Encoding
program: User can
edit any item listed
as needed.
Video Status read area

Page 11 / 30
SFT3542H Encoder Modulator User Manual
Figure-4
Parameters →TS Config:
From the menu on left side of the webpage, clicking “TS Config”, it displays the interface
where users can configure the TS output parameters.
TS Config→Output TS X:
From the menu on up side of the webpage, clicking “Output TS X”, it displays the
interface where users can select the TS output carrier (Figure-5)

Page 12 / 30
SFT3542H Encoder Modulator User Manual
Figure-5
TS Config→Stream select:
From the menu on up side of the webpage, clicking “Stream select”, it displays the
interface where users can select program(s) to multiplex out and modify program info.
(Figure-6)

Page 13 / 30
SFT3542H Encoder Modulator User Manual
Figure-6
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are
as below:
: To add input channel which can from GE1/GE2/Connector
: To edit the input channel
: To delete the input channel
: To delete all inputs channel
: To check input IP lock or not, green means current IP locked
: To check current TS overflow or not, red color means current TS
overflow, need reduce program
: To filter/not filter the source CA information
: To enable/disable the PID remapping
To refresh the input program information
To refresh the output program information
Select one input program first and click this button to transfer the selected
program to the right box to output.
Input Area
Output Area
Operation Area

Page 14 / 30
SFT3542H Encoder Modulator User Manual
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
To parse programs time limitation of parsing input programs
Program Modification:
The multiplexed program information can be modified by clicking the program in the
‘output’ area. For example, when clicking , it triggers a dialog box
(Figure 7) where users can input new information.
Figure-7
TS Config→General:
From the TS Config menu on up side of the webpage, clicking “General”, it displays the
interface where users can set output mode, enable PSI/SI table out, NIT insert/VCT insert,
PCR correction. (Figure-8)

Page 15 / 30
SFT3542H Encoder Modulator User Manual
Figure-8
TS Config→PID Bypass:
From the TS Config menu on up side of the webpage, clicking “PID Bypass”, it displays
the interface as Figure-9 where user can add PIDs to be passed, click the “+” symbol, input
current IP channel number, then input current IP source Pid and output Pid which is
customer needed , then click “set”

Page 16 / 30
SFT3542H Encoder Modulator User Manual
Figure-9
Parameters →Scramber:
From the menu on left side of the webpage, clicking “Scrambler”, it displays the interface
where users can choose the programs to scramble (Figure-10).
This field indicates the current
outputting programs. The
programs selected will be
scrambled.
CA channel select
EMMG and
ECMG working
state, green
means it work
normally, while
red means
communication
error or no
communication.
Output carrier select
Table of contents
Other Softel Modulator manuals
Popular Modulator manuals by other brands

ANTIFERENCE
ANTIFERENCE CONEXER Simplus DMHDS user manual

Channel Plus
Channel Plus 5415 series installation manual

Thor Broadcast
Thor Broadcast H-THUNDER-8 user manual

Triax
Triax CCS-2 1002 Assembly instructions

Pico Macom
Pico Macom PFAM550 Installation and operation manual

Blankom
Blankom HDC 5016 user manual