Solar Ajax User manual

Solar Sikring
MotionProtect Plus
1. FEATURES
Wireless detector with additional microwave sensor Ajax MotionProtect is
designated for human motion detection. It functions as a part of Ajax security
system.
2. SPECIFICATIONS
SPECIFICATION MEANING
Sensor type Wireless
Uses Indoors
Movement detection distance Up to 12 m (39.4 ft)
Sensitivity 3 levels adjustable (low, medium, high)
Detecting elements Pyrosensor and microwave sensor (24GHz)
Additional protection Microwave sensor to filter composite false
alarms sources
Detection angle 88.5° horizontal / 80° vertical
Installation height suggested 2.4 m (7.9 ft)
Pet ignoring option Weight up to 20 kg (44 lb),
size up to 50 cm (19.7 in)
Tamper protection Available
Radio signal power 20 mW
Radio-frequency range 868 or 915 MHz depending on the country
of distribution
Maximum distance between sensor
and central unit 2000 m (6552 ft) (open area)
Power supply CR123A battery
Power supply voltage 3V
Battery life Up to 5 years
Operation temperatures range From 0°С (+32°F) to +50°С (+122°F)
Operation humidity Up to 80%
Dimensions 110х65x50 mm (4.33x2.55x1.96 in)
Weight 96 g
3. COMPONENTS
Motion detector, battery CR123A (pre-installed), manual, installation set
4. GETTING STARTED
4.1 Before installing the sensor, it is required to register it with the Ajax se-
curity system. In order to register the sensor, it is necessary to switch the
Ajax security system’s receiver to «Add Device» mode (the receiver’s man-
ual explains how to accomplish it) and to put the switch «2» (PICTURE 4) on
the sensor to the «ON» position. Sensor’s light must blink at the moment of
switching on. The registration request is transmitted at the moment the sen-
sor is switched on only! In case the registration was not successful, switch
off the sensor, wait for 5 seconds and switch it on again. If the sensor’s light
blinks constantly (each second during one minute), it means that the sensor
is not registered. The light blinks in the same way if the sensor is deleted
from the registration list. Non-registered sensor blinks also throughout 3
seconds during each activation.
4.2 Having registered the sensor successfully, select an appropriate location
to install it.
ATTENTION!
Make sure that in the installation location sensor has a stable radio con-
tact with the receiver! A maximum distance of 2000 m (6552 ft) between
the sensor and the receiver is mentioned as a comparison with other
devices. This distance was found as a result of open area tests. Connec-
tion quality and distance between the sensor and the receiver can vary
depending on installation location, walls, compartments, bridgings,
as well as the thickness and constructional material. Signal coming
through obstacles, loses power. For example, distance range between
the sensor and receiver, divided with two reinforced concrete bearing
walls, constitutes approximately 30 m (98.4 ft). Please note that moving
the sensor even 10 cm (4 in), it is possible to improve the signal recep-
tion considerably.
Before installation, make sure to check the signal strength in the place
where you intend to install the sensor! It is possible to launch a signal lev-
el test on the receiver’s side. Test launching is described in the receiver’s
manual.
ATTENTION!
Signal level test and detection zone test for sensors take some time to
start. A certain period of time is necessary for the receiver to send a test
request to the sensor, and for the sensor to send a test response.
5. INSTALLATION
5.1 The sensor must be installed in such a way that the intruder’s assumed
entrance was perpendicular to the sensor’s lens axis. Make sure to check if
the sensor is functioning at the point where it is going to be installed! (see
paragraph 5.7)
5.2 In order to install the sensor, move the plastic fastening clip Smart-
Bracket (PICTURE 1) alongside the frame and remove it.
5.3 Install the fastening clip SmartBracket on the wall with a help of the ex-
pansion bolts and self-tapping screws included in the set (PICTURE 2). The
height suggested for the sensor installation is 2.4 m (7.9 ft).
Sensor installation height other than the height suggested 2.4 m (7.9 ft) re-
duces sensor detection distance and can diminish the area protected.
PICTURE 1.
MotionProtect Plus detector and its SmartBracket
SmartBracket is to be moved
down and removed
5.4 Put the sensor on the SmartBracket. Once the sensor is fixed on the
SmartBracket, its light must blink. It means that the tamper on the sensor is
shut. In case the sensor does not blink, the tamper status must be checked
at the receiver configuration software!
PICTURE 2.
SmartBracket wall installation scheme
RECEIVER DETECTOR’S LIGHT DESCRIPTION
3 indication bars lights almost permanently, with short
breaks each 1.5 seconds excellent signal
2 indication bars blinks 5 times per second medium signal
1 indication bar blinks twice per second low signal
0 bars short flashes each 1.5 seconds no signal
Solar Plus Ajax MotionProtect Plus

Solar Sikring
www.solar.dk
ATTENTION!
The sensor’s autonomous work duration depends on the sensor’s trig-
gering frequency and the battery quality. On average, one battery is suf-
ficient for 5 years of functioning.
7. WARRANTY
7.1 The sensor’s warranty period is 24 months. The warranty does not cover
the battery!
PICTURE 5. Detector
with the top cover removed
6. MAINTENANCE
6.1 Maintenance is done once every 6 months. The sensor’s board must be
cleared of dust, spider web, and other impurities.
6.2 Never rub the sensor with substances containing alcohol, acetone, pet-
rol and other solvents. Do not rub the sensor with brushes as the fluff can
scrape the lens which will reduce the sensor’s sensitivity.
6.3 Replace the batteries up to date. If the battery level is low, the sensor
sends an appropriate signal to the alarm system receiver unit. When the
battery has run down, with each movement detection or tamper triggering,
the sensor together with a usual indication turns on its light and turns it
off placidly. In order to replace the battery, undo three self-tapping screws
“3” (PICTURE 4) and remove the sensor’s back cover. Replace the «battery»
(PICTURE 5) with a new one, type CR123A observing the polarity.
PICTURE 3. Sensor’s detection zone
0
0
1.71 3.42 5.13 7.84 9.55 11.26 12
0’
0’
5,61’ 11,22’ 16,83’ 25,72’ 31,33’ 36,94’ 39.4’
1.14
2.4 m
0’
3,74’
7,9’
Side view
Sensor
Sensor
0 m 12 m
0
6
6
12 m
39,4’
0’
19,68’
19,68’
39,4’
Top view
1 – tamper button
2 – cut-off switch
3 – self-tapping
screws
4 – fixing holes on
SmartBracket
PICTURE 4.
Detector’s backboard
1
2
3
4
ON OFF
4
4
4
3
3
ATTENTION!
DO NOT install the sensor:
• Near the metal objects causing radio attenuation or shading from it;
• Outside the building;
• In the rooms with temperature and humidity exceeding the appropri-
ate levels.
Be careful while installing the assembling set. Overexertion while in-
stalling can cause deformation and, as a result, impossibility to install
the sensor or to its unreliable fastening. Fix the assembling clip with
the set’s assembling units only! Other fixing system use, for example,
self-tapping screws of big diameter, can damage fastening clip. Togeth-
er with self-tapping screws, there is a double stick tape in the set. It can
be used for temporary sensor fixing only. It is recommended not to use
the tape for the permanent fixing, as the tape dries up over time and the
sensor may fall down which can interfere with its functions.
5.5 The movement sensor is installed!
5.6 Make sure that furniture, curtains, house plants, vases, decoration or
glass constructions do not cover the sensor’s field of view.
5.7 Test the detection zone for movement sensor (PICTURE 3) in order to
check its efficiency. In detection zone test mode, the sensor’s light is on per-
manently, switching off when the movement is detected – it is very easy to
observe.
5.8 Detector is equipped with double motion sensors system. To detect
motion the simultaneous analysis of two sensing elements - pyrosen-
sor and a microwave sensor is carried out. Due to additional microwave
sensor the detector has a high immunity to composite sources of false
alarms (not responding to wavering curtains and blinds heated by sun,
operating heaters, fireplaces, etc.).
In detector settings select desired sensitivity level. High level – the sen-
sor does not react to the objects smaller than a hamster. Medium level
– the sensor does not react to such objects as cats or small dogs. Low
level – the sensor does not react to such objects as medium dogs.
5.9 In “security” mode, the sensor sends the alarm signal each 5 seconds
switching on the light simultaneously in case the movement is registered.
In passive mode, the sensor detects movement no more than once in 3 min-
utes without switching on the light emitting diode.
AJAX Systems Inc.,
www.ajax.systems
battery
ATTENTION!
The sensor’s autonomous work duration depends on the sensor’s trig-
gering frequency and the battery quality. On average, one battery is suf-
ficient for 5 years of functioning.
7. WARRANTY
7.1 The sensor’s warranty period is 24 months. The warranty does not cover
the battery!
PICTURE 5. Detector
with the top cover removed
6. MAINTENANCE
6.1 Maintenance is done once every 6 months. The sensor’s board must be
cleared of dust, spider web, and other impurities.
6.2 Never rub the sensor with substances containing alcohol, acetone, pet-
rol and other solvents. Do not rub the sensor with brushes as the fluff can
scrape the lens which will reduce the sensor’s sensitivity.
6.3 Replace the batteries up to date. If the battery level is low, the sensor
sends an appropriate signal to the alarm system receiver unit. When the
battery has run down, with each movement detection or tamper triggering,
the sensor together with a usual indication turns on its light and turns it
off placidly. In order to replace the battery, undo three self-tapping screws
“3” (PICTURE 4) and remove the sensor’s back cover. Replace the «battery»
(PICTURE 5) with a new one, type CR123A observing the polarity.
PICTURE 3. Sensor’s detection zone
0
0
1.71 3.42 5.13 7.84 9.55 11.26 12
0’
0’
5,61’ 11,22’ 16,83’ 25,72’ 31,33’ 36,94’ 39.4’
1.14
2.4 m
0’
3,74’
7,9’
Side view
Sensor
Sensor
0 m 12 m
0
6
6
12 m
39,4’
0’
19,68’
19,68’
39,4’
Top view
1 – tamper button
2 – cut-off switch
3 – self-tapping
screws
4 – fixing holes on
SmartBracket
PICTURE 4.
Detector’s backboard
1
2
3
4
ON OFF
4
4
4
3
3
ATTENTION!
DO NOT install the sensor:
• Near the metal objects causing radio attenuation or shading from it;
• Outside the building;
• In the rooms with temperature and humidity exceeding the appropri-
ate levels.
Be careful while installing the assembling set. Overexertion while in-
stalling can cause deformation and, as a result, impossibility to install
the sensor or to its unreliable fastening. Fix the assembling clip with
the set’s assembling units only! Other fixing system use, for example,
self-tapping screws of big diameter, can damage fastening clip. Togeth-
er with self-tapping screws, there is a double stick tape in the set. It can
be used for temporary sensor fixing only. It is recommended not to use
the tape for the permanent fixing, as the tape dries up over time and the
sensor may fall down which can interfere with its functions.
5.5 The movement sensor is installed!
5.6 Make sure that furniture, curtains, house plants, vases, decoration or
glass constructions do not cover the sensor’s field of view.
5.7 Test the detection zone for movement sensor (PICTURE 3) in order to
check its efficiency. In detection zone test mode, the sensor’s light is on per-
manently, switching off when the movement is detected – it is very easy to
observe.
5.8 Detector is equipped with double motion sensors system. To detect
motion the simultaneous analysis of two sensing elements - pyrosen-
sor and a microwave sensor is carried out. Due to additional microwave
sensor the detector has a high immunity to composite sources of false
alarms (not responding to wavering curtains and blinds heated by sun,
operating heaters, fireplaces, etc.).
In detector settings select desired sensitivity level. High level – the sen-
sor does not react to the objects smaller than a hamster. Medium level
– the sensor does not react to such objects as cats or small dogs. Low
level – the sensor does not react to such objects as medium dogs.
5.9 In “security” mode, the sensor sends the alarm signal each 5 seconds
switching on the light simultaneously in case the movement is registered.
In passive mode, the sensor detects movement no more than once in 3 min-
utes without switching on the light emitting diode.
AJAX Systems Inc.,
www.ajax.systems
battery
ATTENTION!
The sensor’s autonomous work duration depends on the sensor’s trig-
gering frequency and the battery quality. On average, one battery is suf-
ficient for 5 years of functioning.
7. WARRANTY
7.1 The sensor’s warranty period is 24 months. The warranty does not cover
the battery!
PICTURE 5. Detector
with the top cover removed
6. MAINTENANCE
6.1 Maintenance is done once every 6 months. The sensor’s board must be
cleared of dust, spider web, and other impurities.
6.2 Never rub the sensor with substances containing alcohol, acetone, pet-
rol and other solvents. Do not rub the sensor with brushes as the fluff can
scrape the lens which will reduce the sensor’s sensitivity.
6.3 Replace the batteries up to date. If the battery level is low, the sensor
sends an appropriate signal to the alarm system receiver unit. When the
battery has run down, with each movement detection or tamper triggering,
the sensor together with a usual indication turns on its light and turns it
off placidly. In order to replace the battery, undo three self-tapping screws
“3” (PICTURE 4) and remove the sensor’s back cover. Replace the «battery»
(PICTURE 5) with a new one, type CR123A observing the polarity.
PICTURE 3. Sensor’s detection zone
0
0
1.71 3.42 5.13 7.84 9.55 11.26 12
0’
0’
5,61’ 11,22’ 16,83’ 25,72’ 31,33’ 36,94’ 39.4’
1.14
2.4 m
0’
3,74’
7,9’
Side view
Sensor
Sensor
0 m 12 m
0
6
6
12 m
39,4’
0’
19,68’
19,68’
39,4’
Top view
1 – tamper button
2 – cut-off switch
3 – self-tapping
screws
4 – fixing holes on
SmartBracket
PICTURE 4.
Detector’s backboard
1
2
3
4
ON OFF
4
4
4
3
3
ATTENTION!
DO NOT install the sensor:
• Near the metal objects causing radio attenuation or shading from it;
• Outside the building;
• In the rooms with temperature and humidity exceeding the appropri-
ate levels.
Be careful while installing the assembling set. Overexertion while in-
stalling can cause deformation and, as a result, impossibility to install
the sensor or to its unreliable fastening. Fix the assembling clip with
the set’s assembling units only! Other fixing system use, for example,
self-tapping screws of big diameter, can damage fastening clip. Togeth-
er with self-tapping screws, there is a double stick tape in the set. It can
be used for temporary sensor fixing only. It is recommended not to use
the tape for the permanent fixing, as the tape dries up over time and the
sensor may fall down which can interfere with its functions.
5.5 The movement sensor is installed!
5.6 Make sure that furniture, curtains, house plants, vases, decoration or
glass constructions do not cover the sensor’s field of view.
5.7 Test the detection zone for movement sensor (PICTURE 3) in order to
check its efficiency. In detection zone test mode, the sensor’s light is on per-
manently, switching off when the movement is detected – it is very easy to
observe.
5.8 Detector is equipped with double motion sensors system. To detect
motion the simultaneous analysis of two sensing elements - pyrosen-
sor and a microwave sensor is carried out. Due to additional microwave
sensor the detector has a high immunity to composite sources of false
alarms (not responding to wavering curtains and blinds heated by sun,
operating heaters, fireplaces, etc.).
In detector settings select desired sensitivity level. High level – the sen-
sor does not react to the objects smaller than a hamster. Medium level
– the sensor does not react to such objects as cats or small dogs. Low
level – the sensor does not react to such objects as medium dogs.
5.9 In “security” mode, the sensor sends the alarm signal each 5 seconds
switching on the light simultaneously in case the movement is registered.
In passive mode, the sensor detects movement no more than once in 3 min-
utes without switching on the light emitting diode.
AJAX Systems Inc.,
www.ajax.systems
battery
ATTENTION!
The sensor’s autonomous work duration depends on the sensor’s trig-
gering frequency and the battery quality. On average, one battery is suf-
ficient for 5 years of functioning.
7. WARRANTY
7.1 The sensor’s warranty period is 24 months. The warranty does not cover
the battery!
PICTURE 5. Detector
with the top cover removed
6. MAINTENANCE
6.1 Maintenance is done once every 6 months. The sensor’s board must be
cleared of dust, spider web, and other impurities.
6.2 Never rub the sensor with substances containing alcohol, acetone, pet-
rol and other solvents. Do not rub the sensor with brushes as the fluff can
scrape the lens which will reduce the sensor’s sensitivity.
6.3 Replace the batteries up to date. If the battery level is low, the sensor
sends an appropriate signal to the alarm system receiver unit. When the
battery has run down, with each movement detection or tamper triggering,
the sensor together with a usual indication turns on its light and turns it
off placidly. In order to replace the battery, undo three self-tapping screws
“3” (PICTURE 4) and remove the sensor’s back cover. Replace the «battery»
(PICTURE 5) with a new one, type CR123A observing the polarity.
PICTURE 3. Sensor’s detection zone
0
0
1.71 3.42 5.13 7.84 9.55 11.26 12
0’
0’
5,61’ 11,22’ 16,83’ 25,72’ 31,33’ 36,94’ 39.4’
1.14
2.4 m
0’
3,74’
7,9’
Side view
Sensor
Sensor
0 m 12 m
0
6
6
12 m
39,4’
0’
19,68’
19,68’
39,4’
Top view
1 – tamper button
2 – cut-off switch
3 – self-tapping
screws
4 – fixing holes on
SmartBracket
PICTURE 4.
Detector’s backboard
1
2
3
4
ON OFF
4
4
4
3
3
ATTENTION!
DO NOT install the sensor:
• Near the metal objects causing radio attenuation or shading from it;
• Outside the building;
• In the rooms with temperature and humidity exceeding the appropri-
ate levels.
Be careful while installing the assembling set. Overexertion while in-
stalling can cause deformation and, as a result, impossibility to install
the sensor or to its unreliable fastening. Fix the assembling clip with
the set’s assembling units only! Other fixing system use, for example,
self-tapping screws of big diameter, can damage fastening clip. Togeth-
er with self-tapping screws, there is a double stick tape in the set. It can
be used for temporary sensor fixing only. It is recommended not to use
the tape for the permanent fixing, as the tape dries up over time and the
sensor may fall down which can interfere with its functions.
5.5 The movement sensor is installed!
5.6 Make sure that furniture, curtains, house plants, vases, decoration or
glass constructions do not cover the sensor’s field of view.
5.7 Test the detection zone for movement sensor (PICTURE 3) in order to
check its efficiency. In detection zone test mode, the sensor’s light is on per-
manently, switching off when the movement is detected – it is very easy to
observe.
5.8 Detector is equipped with double motion sensors system. To detect
motion the simultaneous analysis of two sensing elements - pyrosen-
sor and a microwave sensor is carried out. Due to additional microwave
sensor the detector has a high immunity to composite sources of false
alarms (not responding to wavering curtains and blinds heated by sun,
operating heaters, fireplaces, etc.).
In detector settings select desired sensitivity level. High level – the sen-
sor does not react to the objects smaller than a hamster. Medium level
– the sensor does not react to such objects as cats or small dogs. Low
level – the sensor does not react to such objects as medium dogs.
5.9 In “security” mode, the sensor sends the alarm signal each 5 seconds
switching on the light simultaneously in case the movement is registered.
In passive mode, the sensor detects movement no more than once in 3 min-
utes without switching on the light emitting diode.
battery
Other Solar Security System manuals
Popular Security System manuals by other brands

Paradox
Paradox MG5000 user guide

HIK VISION
HIK VISION DS-PEA102S user manual

BitronHome
BitronHome 902010/29 Quick start manual

Ultra Secure
Ultra Secure PROTEC 800 user manual

Deep Innovations
Deep Innovations PoolScout owner's manual

Fireboy- Xintex
Fireboy- Xintex DU-RBH-01 Owner's Manual & Installation Instructions

ADT
ADT Safewatch QuickConnect Plus Troubleshooting

Swann
Swann REDALERT SW242-WDV operating instructions

DSC
DSC PC51O2-433NA installation manual

PRASTEL
PRASTEL FMID082 installation instructions

First Alert
First Alert FA168CPS / FA168CPSSIAA168CPSSIAA168CPSSIAA168CPSSIAFA148CP / FA148CPSIAFA148CP /... Installation and setup guide

Pfannenberg
Pfannenberg DS Series Instructions for operating and installing