SolarEdge Key User manual


Contents
SolarEdge Key User Guide MAN-01-00131-1.2
1
Contents
English.................................................................................5
Disclaimers...................................................................... 5
Important Notice...................................................................5
FCC Compliance ....................................................................6
Support and Contact Information................................... 7
Handling and Safety Instructions .................................... 8
Safety Symbols......................................................................8
Safety Instructions ................................................................9
Chapter 1: Introducing the SolarEdge Key .................... 10
Chapter 2: Using the SolarEdge Key.............................. 11
The SolarEdge Key Interface ...............................................11
Before Using the SolarEdge Key..........................................12
Connecting the SolarEdge Key to PV Strings .......................13
Disabling SafeDC .................................................................14
Enabling SafeDC ..................................................................15
Appendix A: Errors and Troubleshooting...................... 17
Appendix B: Technical Specifications............................ 19
Deutsch.............................................................................21
Haftungsausschluss....................................................... 21
Wichtiger Hinweis ...............................................................21
FCC-Konformität .................................................................22
Kundendienst und Kontakt ........................................... 23
Bedienungsanleitung und Sicherheitshinweise ............ 24
Gefahrensymbole................................................................24
Sicherheitshinweise ............................................................25

Contents
SolarEdge Key User Guide MAN-01-00131-1.2
2
Kapitel 1: Vorstellung des SolarEdge Key...................... 26
Kapitel 2: Verwendung des SolarEdge Key ................... 28
Die SolarEdge Key Bedienoberfläche ..................................28
Vor der Verwendung des SolarEdge Key.............................29
Den SolarEdge Key an einen PV-String anschließen ............30
SafeDC deaktivieren............................................................31
SafeDC aktivieren................................................................32
Anhang A: Fehler und Fehlerbehebung ........................ 35
Anhang B: Technische Spezifikationen ......................... 38
Italiano..............................................................................39
Avvertenze.................................................................... 39
Avviso importante...............................................................39
Conformità FCC ...................................................................40
Supporto e informazioni di contatto ............................ 41
ISTRUZIONI PER LA GESTIONE E LA SICUREZZA ............ 42
Simboli di sicurezza .............................................................42
ISTRUZIONI PER LA SICUREZZA............................................43
Capitolo 1: Introduzione della Chiave SolarEdge .......... 44
Capitolo 2: Utilizzo della Chiave SolarEdge................... 46
Interfaccia della Chiave SolarEdge ......................................46
Prima di utilizzare la Chiave SolarEdge................................47
Collegamento della Chiave SolarEdge alle Stringhe PV .......48
Disabilitazione di SafeDC.....................................................49
Abilitazione di SafeDC .........................................................51
Appendice A: Errori e ricerca dei guasti........................ 53
Appendice B: Specifiche tecniche ................................. 56
Français.............................................................................57
Mentions légales........................................................... 57

Contents
SolarEdge Key User Guide MAN-01-00131-1.2
3
Avis Important ....................................................................57
Conformité aux normes FCC ...............................................58
Informations d’assistance et de contact....................... 59
CONSIGNES DE MANIPULATION ET DE SÉCURITÉ......... 60
SYMBOLES DE SÉCURITÉ .....................................................60
CONSIGNES DE SÉCURITÉ....................................................61
Chapitre 1 : Présentation de la clé SolarEdge ............... 62
Chapitre 2 : Utilisation de la clé SolarEdge ................... 64
L’interface de la clé SolarEdge ............................................64
Avant l’utilisation de la clé SolarEdge .................................65
Connexion de la clé SolarEdge à des chaînes PV .................66
Désactivation SafeDC ..........................................................67
Activation SafeDC................................................................68
Appendice A: Erreurs et dépannage ............................. 71
Appendice B : Spécifications techniques ...................... 74
日本人 ..............................................................................75
免責条項 ...................................................................... 75
重要 ....................................................................................75
FCC準拠 ............................................................................76
サポートと問い合わせ先情報 ......................................... 77
取り扱いと安全上の指示............................................... 78
安全上のシンボル ................................................................78
安全上の指示 .....................................................................79
第1章: SolarEdgeキーの紹介......................................... 80
第2章: SolarEdgeキーの使用......................................... 81
SolarEdgeキーのインターフェース .........................................81
SolarEdgeキーの使用の前に ..............................................82

Contents
SolarEdge Key User Guide MAN-01-00131-1.2
4
SolarEdgeキーをPVストリングに接続 ..................................83
SafeDCの無効化 ...............................................................84
SafeDCの有効化 ...............................................................85
付録A: エラーとトラブルシューティング .............................. 87
付録B: 技術仕様 .......................................................... 89

Disclaimers
SolarEdge Key User Guide MAN-01-00131-1.2
5
English
Disclaimers
Important Notice
Copyright © SolarEdge Inc. All rights reserved.
No part of this document may be reproduced, stored in a retrieval
system or transmitted, in any form or by any means, electronic,
mechanical, photographic, magnetic or otherwise, without the prior
written permission of SolarEdge Inc.
This document is solely for the use of SolarEdge customers and
employees.
The material furnished in this document is believed to be accurate
and reliable. However, SolarEdge assumes no responsibility for the
use of this material. SolarEdge reserves the right to make changes to
the material at any time and without notice. You may refer to the
SolarEdge web site (www.solaredge.com) for the most updated
version.
All company and brand products and service names are trademarks
or registered trademarks of their respective holders.
Patent marking notice: http://www.solaredge.com/groups/patent
The general terms and conditions of purchase of SolarEdge products
shall apply.
The content of these documents is continually reviewed and
amended, where necessary. However, discrepancies cannot be
excluded. No guarantee is made for the completeness of these
documents.
English

Disclaimers
SolarEdge Key User Guide MAN-01-00131-1.2
6
FCC Compliance
This equipment has been tested and found to comply with FCC part
15 subpart B Class A regulations. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment OFF and ON, you are
encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the
receiver and its antenna.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
Changes or modifications not expressly approved by the party
responsible for compliance may void the user’s authority to operate
the equipment.

Support and Contact Information
SolarEdge Key User Guide MAN-01-00131-1.2
7
English
Support and Contact Information
If you have technical queries concerning our products, please
contact us:
US & Canada
1877 360 5292
support@solaredge.us
Germany
+49 89-45459730
support@solaredge.de
France
0800917410
support@solaredge.fr
Belgium
080073041
support@solaredge.be
Italy
800 784 824
support@solaredge.it
Japan
+81.3.5530.9360
support@solaredge.jp
Asia-Pacific
support_asia@solaredge.
com
Netherlands
08000221089
support@solaredge.com
United Kingdom
0800 028 1183
Greece
00800125574
Israel
+972 73 240-3118
Australia
1800 46 55 67
Worldwide
+972 73 240-3118
Fax
+972 73 240-3117
Before contact, make sure to have the following information readily
available:
Inverter and power optimizer model
Serial number of the SolarEdge Key device
The error indicated on the SolarEdge Key screen (if exists).
System configuration information, including the type and
number of modules connected and the number and length of
strings.

Handling and Safety Instructions
SolarEdge Key User Guide MAN-01-00131-1.2
8
Handling and Safety Instructions
During installation, testing and inspection adherence to all the
handling and safety instructions is mandatory.
Safety Symbols
The following safety symbols are used in this document. Familiarize
yourself with the symbols and their meaning before installing or
operating the system.
WARNING!
Denotes a hazard. It calls attention to a procedure that, if not
correctly performed or adhered to, could result in injury or loss
of life. Do not proceed beyond a warning note until the
indicated conditions are fully understood and met.
CAUTION:
Denotes a hazard. It calls attention to a procedure that, if not
correctly performed or adhered to, could result in damage or
destruction of the product. Do not proceed beyond a caution
sign until the indicated conditions are fully understood and met.
NOTE:
Denotes additional information about the current subject.
IMPORTANT SAFETY FEATURE:
Denotes information about safety issues.

Handling and Safety Instructions
SolarEdge Key User Guide MAN-01-00131-1.2
9
English
Safety Instructions
WARNING!
To avoid electrical shock disconnect electrical circuits before
opening the SolarEdge Key case.
CAUTION:
This unit must be operated according to the manufacturer’s
instructions. If the equipment is used in a manner not
specified by the manufacturer, the protection provided by the
equipment may be impaired.
CAUTION:
The SolarEdge Key can only be connected to a single string
of PV Modules. Do not connect the SolarEdge Key to any
main circuits, such as the inverter; Safety & Monitoring
Interface (SMI) or other equipment that is directly connected
to main circuits.
NOTE:
The following warning symbols appear on the SolarEdge Key
product label:
Symbol
Warning
Risk of electric shock. Do not open the
case when connecte d to electrical circuit.
Read product instructions before use
Equipment isolated by at least two
insulation layers
NOTE:
The SolarEdge Key is IP65 rated. The product should not be
submerged into water. For cleaning use a damp cloth or IPA.
NOTE:
Do not use the product if it is damaged in any way.

Chapter 1: Introducing the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
10
Chapter 1: Introducing the
SolarEdge Key
The SolarEdge Key is a service tool that is used to enable power
optimizers to work with non-SolarEdge inverters without installing
any additional hardware. In order to work with non-SolarEdge
inverters, power optimizers must support IndOP™ (Independent
Optimization); the part number of the power optimizer should start
with OPI, OPJ, OPxxx-LVJ or PxxxI.
All power optimizers provided by SolarEdge have the SafeDC™
feature enabled: When connected to a PV module, these power
optimizers output a safe voltage of 1VDC until they are paired either
with a SolarEdge inverter, or with the SolarEdge Safety & Monitoring
Interface (SMI), and until power production has started. Refer to
SolarEdge Power Optimizers Installation Guide for more details.
When connecting PV strings with power optimizers directly to a non-
SolarEdge inverter without a Safety and Monitoring Interface, SafeDC
must be disabled before connecting the string to the inverter.
The SolarEdge Key is used to configure power optimizers to one of
the following modes of operation:
SafeDC™: When the power optimizer is connected to a PV
module, its output voltage is limited to a safe voltage of 1V DC
until the optimizer is connected and paired with SolarEdge
inverter or with SMI. When the SolarEdge inverter/SMI are
operating, the power optimizer’s output voltage raises above
1V DC and the optimizer provides power. When the SolarEdge
Inverter / SMI are turned off, the power optimizer’s output
voltage is back to a safe voltage of 1V DC.
SafeDC Disabled: When the power optimizer is connected to a
PV module, its output voltage is limited to the open circuit
voltage (Voc) of the connected PV module.

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
11
English
Chapter 2: Using the SolarEdge
Key
The SolarEdge Key Interface
Figure 1: SolarEdge Key interface
LCD display
SafeDC Disable /
Confirm button
SafeDC Enable /
Esc button
ON/OFF button
Connection to string
Display button

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
12
LCD display –with 8 characters
ON/OFF button –turns the unit ON and OFF
Menu buttons - each with two functionalities , as described in
the following table:
Button Press
SafeDC
Enable / Esc
Display
Button
SafeDC
Disable /
Confirm
Short Press
(less than 1sec)
Esc
Toggle
Display
Confirm
Long Press
(more than 1 sec)
Enable safety
voltage
N/A
Disable safety
voltage
Before Using the SolarEdge Key
1Make sure the SolarEdge Key is not connected to a string.
2Open the SolarEdge key back cover.
3Insert three AA batteries (nominal voltage 1.5V; not supplied)
into the battery compartment and close the cover.
4Press the ON/OFF button ( ) to turn the SolarEdge Key ON. If
LOW BAT appears, replace batteries.
5Press the ON/OFF button to turn the SolarEdge Key OFF. The
message End appears on the LCD and then the SolarEdge Key
turns OFF.

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
13
English
Connecting the SolarEdge Key to PV
Strings
1Connect the string cables to the two connectors at the bottom
of the SolarEdge Key (see Figure 1).
2Press the ON/OFF button. The string voltage appears on the
LCD screen:
V o X X X . X
Figure 2: SolarEdge Key connection
3Short press the center button (Display Button) to toggle
between the following options:
LCD Display
Description
Vo XXX.X
The string voltage measurement
Bat XXXX
The battery state: 4 bars (||||) - full;
one bar (|) - low
#OP XXXX
The estimated number of power
optimizers in the string. The screen
initially starts as #OP ---- and updated
after SafeDC state is changed
If you do not press any button for five minutes, the SolarEdge
key shuts down automatically.

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
14
Disabling SafeDC
When connecting power optimizers directly to a non-SolarEdge
inverter without a Safety and Monitoring Interface, disabling the
SafeDC mode is required in order to reset the string before
connecting to the inverter.
NOTE:
Do not start the process of disabling SafeDC in case of low
battery.
NOTE:
Disable the safeDC for each string individually.
►To disable the SafeDC mode:
1If using add-on power optimizers (OPIxxx or PxxxI), make sure
each power optimizer is connected to the PV module, as
described in the SolarEdge Power Optimizers Installation Guide.
2Connect power optimizers in a string, as described in the
SolarEdge Power Optimizers Installation Guide.
3Connect a string of power optimizers to the SolarEdge Key (see
Figure 2).
4Check that the string voltage (Vo xxx.x) is compatible with
the number of optimizers. When power optimizers are in
SafeDC mode, the Vo of each optimizer is 1V dc.
5Long press SafeDC Disable. The screen displays IndOP and
then N / Y?
6Short press the right button (Confirm) to continue or the left
button (Esc) to abort;
If you confirmed, the screen displays a backward countdown
and then displays #OP: xx
(xx= number of power optimizers in the string, between 0-30).

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
15
English
After 5 seconds, the string output voltage Vo is displayed
(xxx.x). The SafeDC mode is now disabled and the voltage of
each power optimizer equals the voltage of the module.
WARNING!
The DC cables carry a high voltage and the power
optimizers no longer output a safe 1V output.
PROCEED WITH CARE!
7Disconnect the string cables and connect them to the inverter.
8Perform the commissioning steps of the inverter as described
in its manual. When connecting to inverters without SMI,
pairing is not required.
Enabling SafeDC
When connecting power optimizers directly to a SolarEdge inverter
or to a Safety and Monitoring Interface, SafeDC should be enabled to
ensure that all power optimizers are set to a 1V DC output voltage
before connecting to SolarEdge inverter or SMI.
NOTE:
Enable the safeDC for each string individually.
►To enable SafeDC:
1If using add-on power optimizers (OPIxxx or PxxxI), make sure
each power optimizer is connected to the PV module, as
described in the SolarEdge Power Optimizers Installation Guide.
2Connect power optimizers in a string, as described in the
SolarEdge Power Optimizers Installation Guide.
3Connect a string of power optimizers to the SolarEdge Key (see
Figure 2).

Chapter 2: Using the SolarEdge Key
SolarEdge Key User Guide MAN-01-00131-1.2
16
4Long press SafeDC Enable. The screen displays SafeDC and
then N / Y?
5Short press the right button (Confirm) to continue or the left
button (Esc) to abort;
If you confirmed, the screen displays a backward countdown
and then displays #OP: xx
(xx= number of power optimizers in the strings, between 0-30).
6After 5 seconds, the string output voltage Vo is displayed
(xxx.x).
The SafeDC mode is now active and the voltage of each power
optimizer is 1V. The string voltage equals the number of power
optimizers (less than 30V). When connecting to inverters with
SMI, perform the Commissioning steps as described in the
SolarEdge SMI Installation Guide, available on the SolarEdge
website at
http://www.solaredge.com/files/pdfs/products/inverters/guid
es/se_installation_guide_safety_monitoring.pdf.
All the power optimizers must be logically paired to the SMI.
The power optimizers do not start producing power until they
are paired with an SMI.

Appendix A: Errors and Troubleshooting
SolarEdge Key User Guide MAN-01-00131-1.2
17
English
Appendix A: Errors and
Troubleshooting
When an error occurs, the LCD displays one of the following
messages:
Error Description
Possible Cause
Possible Troubleshooting
SolarEdge Key
displays
OV! XXXX.X
The string voltage
is higher than the
maximum allowed
system voltage
(1000V)
Turn the SolarEdge Key OFF
and disconnect the PV string.
Refer to the PV module
datasheet to determine the
maximum number of modules
that can be connected into a
string without exceeding the
1000V limit for the SolarEdge
Key
SolarEdge Key
displays Inv Vo
Negative string
voltage
Reversed polarity - Refer to
the SolarEdge Installation
Manual for more details.
SolarEdge Key
displays Failed
after pressing
SafeDC Disable
PV String is too
long
Connect up to 30 optimizers
(not more than 1000V total) to
the SolarEdge Key and repeat
SafeDC disabling (Disabling
SafeDC, on page 14).
The number of
power optimizers
on the LCD display
after SafeDC
disabling is less
than the number of
power optimizers
connected in the
string
One or more
power optimizers
are not connected
properly to the
string.
Check the power optimizers'
connection and repeat
SafeDC disabling.
One or more
power optimizers
are shaded or not
getting enough
power during the
commissioning
Repeat SafeDC disabling
when all power optimizers
have sufficient power (all PV
modules are exposed to sun
light).

Appendix A: Errors and Troubleshooting
SolarEdge Key User Guide MAN-01-00131-1.2
18
Error Description
Possible Cause
Possible Troubleshooting
The SolarEdge Key
displays Failed
after pressing
SafeDC Enable
One or more
optimizer did not
communicate to
the SolarEdge Key
Check all power optimizers'
connections.
Repeat the SafeDC enabling
(Enabling SafeDC, on
page 15).
If the error persists, contact
SolarEdge support.
After enabling
SafeDC, the string
voltage is higher
than the number of
power optimizers in
the string
One or more
power optimizers
did not turn to
SafeDC (not
enough power due
to shading or other
reason)
Repeat SafeDC enabling
when all power optimizers
have sufficient power (all PV
modules are exposed to sun
light).
After enabling
SafeDC, the string
voltage is lower
than the number of
power optimizers in
the string
One or more
optimizers are
OFF (for example,
if there is not
enough power due
to shading or other
reason)
Repeat SafeDC enabling
when all power optimizers
have sufficient power (all PV
modules are exposed to sun
light).
For troubleshooting SolarEdge equipment errors, refer to the
SolarEdge Power Optimizer Installation Guide or SolarEdge Inverter
Installation Guide.

Appendix B: Technical Specifications
SolarEdge Key User Guide MAN-01-00131-1.2
19
English
Appendix B: Technical
Specifications
Electrical Specifications
Number of string inputs
1 (MC-4)
Number of power optimizers
that can be commissioned in
single string
4-30 power optimizers
Maximum input voltage
1000
Vdc
Power supply
3 x AA batteries (nominal
voltage 1.5V) (not
supplied)
Mechanical Specifications
Dimensions (L x W x H)
171 x 83 x 38 /
6.7 x 3.3 x 1.5
mm/Inch
Weight
<0.5 / 1.1
kg / lbs
Standard Compliance
Electromagnetic
compatibility
FCC Part15 Class A,
IEC61000-6-2,
IEC61000-6-3
Safety
IEC61010-1,
IEC61010-031
Environmental Specifications
Storage temperature range
-40 to 85 / -40 to 185
ºC / ºF
Operating temperature
range
-20 to 50 / -4 to 122
ºC / ºF
Relative humidity (non
condensing)
0 - 95
%
Protection rating
IP65
Table of contents