2 Validity
This document is intended for qualied persons. The activities described here must only be carri-
ed out by persons with the following minimum qualications:
• Training in the installation and commissioning of electrical devices
• Training with respect to electrical hazards and locally applicable safety requirements
• Knowledge of the applicable standards and directives
• Familiarity and compliance with this document and all safety instructions.
3 Intended use
The Phase Splitter is an add-on installation
kit to be used for installations in which the
single-phase house connection cables have a
diameter greater than 16mm² and/or an inco-
ming current larger than 63A. The installation
of the Phase Splitter is only to be used in com-
bination with installation instructions for the
SOLARWATT AC Sensor 63.
4 Safety instructions
• To ensure that the cross-section of an in-
coming cable is not undershot, all 3 cables
supplied must be connected.
• The phase splitter must not be used with
incoming cables with a cross-section lar-
ger than 30 mm².
• If the cables supplied are too short for your
arrangement of the clamps and ACS63, ca-
bles must be custom made which fulll
the following criteria:
- Same length, same cross-section, same
material
- Wire end ferrules, if necessary accor-
ding to local installation instructions
• The installer is responsible for correct in-
stallation
• Only the connections described in the in-
structions may be made. Do not connect
other cables to the free terminals..
5 Technical data for the potential collector
You can nd further technical data on the potential collection terminals from PhoenixContact at
www.phoenixcontact.com under the material number 3213142.
Number of poles 1
Number of connections 5
Potentials 1
Nominal cross section 70 mm²
Rated current IN
189 A
(due to the maximum measuring current of AC
Sensor 63)
PAGE 4 | Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH