POWER SUPPLY P3208
DESCRIPTION
Switched 7,5 VA power supply unit.
Designed to supply installations with 1 tuner and 1 stereo control; or for
installations with 2 mono controls.
It has a permanent connection to network (no switch); we recommend
installing a specific general swith for the sound installation.
It can be used in every type of installation.
GENERAL CHARACTERISTICS
Power supply unit stabilised and regulated.
Connection to network via screw-strips
230V - 50Hz nominal network voltage.
Output voltage: 15Vdc-0.4 / 7W
Permanent connection to network; cable section <0.75 mm2
Output voltage indication led.
Output protected against shortcuts
Internal fuse for network input protection
Due to its dimensions, it can be installed in standard box, together with
a PCB series control.
-
-
-
-
-
-
-
-
-
CONNECTION
1. Power supply
2. ON led
3. Installation supply strips
4. Network connection strips
TERMINALS:
L- Fhase (220/230 V AC)
N- Neutral (220/230 V AC)
2- Positive - nominal 15 V DC voltage output 0,5 A maximum.
4- Negative - Supply and signal earth.
The connection to the 220/230V electricity supply mains will be made
with 0.75 mm2 section wires and double insulation .
Sonelco recommends installing a specific general switch for the sound
installation. (See installation example).
4FA036801
TECHNICAL CHARACTERISTICS
SUPPLY:
Operation: 120-264 V AC / 50-60Hz
Maximum power: 7,5 VA
Output voltage: regulated between 15 V ± 5%
Output impedance: 1,5 A
Electronic protection against short-circuits and power surges.
Internal fuse for the protection of the power supply.
GENERAL:
Maximum dimensions: 49 x 49 x 23 mm.
Weight: 40 grs.
12
3
4
IMPORTANT NOTE: Before connecting this apparatus to
the mains electricity supply, the Mains Switch of that
installation should be switched off in order to allow the connec-
tions to be made with safety guarantees. Under no circumstances
should the source be handled outside its built-in box whilst con-
nected to the alternate current. Please make sure that the earth
connection is appropriately connected.
CONNECTION TO THE NETWORK: Screw in the mains supply and
earth cables to the L, N.
CONNECTION TO THE LINE: (See diagramme). Connect the line 2 and
4 cables following the order indicated in the terminals, making sure to
fasten them tightly.
START-UP: Once the apparatus is installed connect the mains switch of
the installation in order to supply electricity to the apparatus and check
that the ON led is lit (2).
OPERATION INCIDENTS:
Notice: Any handling of the power supply should only be carried out by
specialised technical personnel and with the mains switch of the audio
installation disconnected.
A.- LED 2 (ON) DOES NOT LIGHT UP WHEN CONNECTING THE
MAINS SUPPLY SWITCH
1. Please check the existence of voltage in the network, and the correct
connection of the network cables.
2. Disconnect strips 2, 4. If the led lights up, the power supply is ok,
indicating a short-circuit in the supply output (2, 4) and the cabling
should be revised.
B.- THE LED (ON) flashes.
1. The apparatus enters in a protected mode due to an excessive load
on its supply terminals. Revise the cabling of the installation and the
number of modules connected to this power supply. It may be that the
maximum power that the device can supply is being exceeded.
INSTALLATION EXAMPLES
FIGURE 1: Installation example in the WC of a hotel's room.
1 stereo/mono music channel from TV or any other sound source. We have used a TV in the example, so it will be necessary to
use a screened cable.
FIGURE 2: Installation example with the power supply P3208 installed next to the speaker in the false ceiling.
2 stereo/mono channels. 1 channel from the FM tuner of the control PCP1272 and channel nº2 comes from the auxiliary sound source
24
LR
230V
PCB1210
PC7110
P3208
24
LR
230V
P3208
PCP1272
P3208 26-05-09These characteristics are provided for information purposes only. The manufacturer reserves the right to make modifications without prior notice in order to improve the product
In Sonelco General Diagrammes you may find connection diagrammes and cable sections recommended for audio installations. Do not place this product
in wet areas, next to sources of heat or potentially explosive areas.
The connection to the electric mains power supply, installation, cable diameter and channelling should be carried out in accordance with the directives
and specific regulation of each country.
Sonelco recommends the installation of a specific mains switch for the audio installation. (see installation example).
Sonelco declines any responsibility that may be caused by an inappropriate use of the product or by an installation that does not comply
with that recommended.
INSTALLATION RECOMMENDATIONS
Por GERARDO fecha 14:56 , 27/05/2009

Other Sonelco Power Supply manuals

Sonelco P3270 User manual

Sonelco

Sonelco P3270 User manual

Sonelco P3226 User manual

Sonelco

Sonelco P3226 User manual

Sonelco P3262 User manual

Sonelco

Sonelco P3262 User manual

Popular Power Supply manuals by other brands

Locknetics LP150 installation instructions

Locknetics

Locknetics LP150 installation instructions

Vigitron MaxiiPower Vi2201 installation manual

Vigitron

Vigitron MaxiiPower Vi2201 installation manual

Xantrex 850W operating manual

Xantrex

Xantrex 850W operating manual

H3C PS-2551-9L3 manual

H3C

H3C PS-2551-9L3 manual

Pulsar PSU-B-27.6V/S-5A/1/EL-TR-2x17Ah/MC manual

Pulsar

Pulsar PSU-B-27.6V/S-5A/1/EL-TR-2x17Ah/MC manual

RND power 315-00009 user manual

RND power

RND power 315-00009 user manual

Puls PIANO Series manual

Puls

Puls PIANO Series manual

Relcom FPS-I installation instructions

Relcom

Relcom FPS-I installation instructions

C-COR Optiworx HW Series Procedures manual

C-COR

C-COR Optiworx HW Series Procedures manual

Rebel RB-4011 owner's manual

Rebel

Rebel RB-4011 owner's manual

Pico Macom MPD user guide

Pico Macom

Pico Macom MPD user guide

SonicWALL NSA 2650 installation guide

SonicWALL

SonicWALL NSA 2650 installation guide

Nice DC12-IP user guide

Nice

Nice DC12-IP user guide

Monster PowerCenter HTUPS2700 owner's manual

Monster

Monster PowerCenter HTUPS2700 owner's manual

ASL INTERCOM PS 289 user manual

ASL INTERCOM

ASL INTERCOM PS 289 user manual

CAMBRIONIX TS3-C10 user manual

CAMBRIONIX

CAMBRIONIX TS3-C10 user manual

Thermolec DCC-9 Series installation manual

Thermolec

Thermolec DCC-9 Series installation manual

GW Instek PSU Series Programming manual

GW Instek

GW Instek PSU Series Programming manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.