Sonnen WM271 User manual

Manual | for authorised electricians
info@sonnenbatterie.de · www.sonnenbatterie.deKD-396 · Version X00
Power meter WM271 - Activating/Deactivating Eas Connection (EC)

EN IMPORTANT
► Read this documentation carefully before installation.
► Retain this document for reference purposes.
Publisher
sonnen GmbH
Am Riedbach 1
87499 Wildpoldsried
Service number +49 8304 9 933 444
E-Mail [email protected]
Document
Document number KD-396
Part number -
Version X00
Publication date 06/13/ 017
/ 9
KD-395 | EN | X00

Table of contents
Table of contents
1 Information about this document.................................................................
1.1 Target group of this document.............................................................................5
1. Explanation of symbols........................................................................................ 5
2 Safety..............................................................................................................
3 Programming the WM 271............................................................................6
3.1.1 Mounting the touch display.........................................................................6
3.1. Changing to programming mode...............................................................7
3.1.3 Using the touch display in programming mode.........................................7
3.1.4 Leaving the programming mode................................................................8
3. Programming page Easy Connection (EC)......................................................9
KD-395 | EN | X00 3 / 9

Information about this document
1
1 Information about this document
This document contains additional information about the programming mode Easy
Connction (EC) of the power meter WM 71.
► Observe the respective installation instructions, in particular the safety
instructions.
1.1 Target group of this document
This document is intended for authorised electricians. The actions described here
must only be performed by authorised electricians.
1.2 Explanation of symbols
Extremely dangerous situation leading to certain death or serious injury if the
safety information is not observed.
Dangerous situation leading to potential death or serious injury if the safety
information is not observed.
Dangerous situation leading to potential injury if the safety information is not
observed.
Indicates actions that may cause material damage.
Important information not associated with any risks to people or property.
Symbol Meaning
► Work step
1. . 3. … Work steps in a defined order
•List
Table 1: Additional symbols
2 Safety
Carrying out of electrical work may be necessary in order to implement the
settings described in this document. Pleas note:
KD-395 | EN | X00 5 / 9
CAUTION
DANGER
WARNING
Notice
CAUTION
DANGER
WARNING
Notice
CAUTION
DANGER
WARNING
Notice
CAUTION
DANGER
WARNING
Notice

2
Safety
Electrical work on the electrical distributor
Danger to life due to electrocution!
► Disconnect the relevant electrical circuits.
► Secure against anyone switching on the device again.
► Check that there is no voltage present on the system.
► Only authorised electricians are permitted to carry out electrical work.
3 Programming the WM 271
The power meter WM 71 can be programmed with a touch display.
3.1.1 Mounting the touch display
Tools:
•Touch display
•Screwdriver
1 Front cover of the power meter
Clip to remove the front cover
► Press the clips ( ) on both sides of
the power meter.
You might use a small screwdriver.
► Remove the front cover (1).
1 Touch display
► Insert the touch display into the
power meter.
► Supply the power meter with
energy.
6 / 9 KD-395 | DE | X00
CAUTION
DANGER
WARNING
Notice
Figure 1: Removing the front cover
1
2
3
4
6
A1 A2
N L1 L2 L3
power meter
WM 271
Strommessung
Erzeugung Verbrauch
Current Measurement
Generation Consumption
Voltage Metering
Spannungsmessung
1
2
Figure : Inserting the touch display
1
2
3
4
6
A1 A2 N L1 L2 L3
1

Programming the WM 271
3
3.1.2 Changing to programming mode
After mounting the touch display the power meter is set to display mode. Values
are shown on the display but can not be changed.
To change values the mode of the power meter must be changed to programming
mode.
Figure 3: Touch display
► Press for at least 3 seconds.
The PASS ? screen appears.
Figure 4: Password entry screen
The password needs to be entered. The
default password is 0.
► Press for 3 seconds.
The CnGPASS screen appears.
The power meter is now in
programming mode.
3.1.3 Using the touch display in programming mode
The touch display can be operated by using the buttons and .
Navigation on the touch display
Figure 5: CnGPASS screen
You can navigate from the CnGPASS
screen to the desired programming
screen by pressing the key.
KD-395 | EN | X00 7 / 9
1
2
3
4
6
1
2
3
4
6
1
2
3
4
6

3
Programming the WM 271
Changing values in the programming mode
1
2
3
4
61.2.3... 3.2.1...
3 sec. 3 sec.
OK OK
1.
2.
3.
4.
Figure 6: Procedure for changing values
1. Changing of values becomes
possible by pressing the key. The
symbol appears on the touch
display.
2. The algebraic sign can be changed
by pressing the key again. The
selected value is increase if is
selected and reduced if is
selected.
3. The desired value can be selected by
pressing the key.
4. To set a selected value press the
key (for about 3 seconds).
3.1.4 Leaving the programming mode
Figure 7: End screen
► Navigate to the End screen.
► Press to leave the programming
mode.
The power meter is now set to display
mode.
8 / 9 KD-395 | DE | X00
1
2
3
4
6

Programming the WM 271
3
3.2 Programming page Easy Connection (EC)
Figure 8: EC screen
On this programming page the Easy
Connection (EC) function can be
activated/deactivated. This function is
used to determine whether or not the
energy flow direction is taken into
account. The EC function is activated
by default.
Figure 9: Case 1 (left): the energy flow in
the conductor is from K to L /
Case (right): the energy flow in the
conductor is from L to K
Easy Connection activated (EC yes)
If Easy Connection is activated (EC
yes; Default yes) it does not matter if
the energy flow in the conductor is
from K to L (Case 1) or vice versa (Case
). The power meter always calculates
with positive values (amounts).
Easy Connection deactivated (EC
no)
If Easy Connection is deactivated (EC
no) the energy flow direction
determines the algebraic sign of the
power. The algebraic sign of the power
is positive if the energy flow in the
conductor is from K to L (Case 1). In
the opposite case (Case ) the algebraic
sign of the power is negative.
KD-395 | EN | X00 9 / 9
K
L
K
L
1 2
EC yes +
EC no +
EC yes +
EC no

sonnen GmbH
Am Riedbach 1
D-87499 Wildpoldsried
Popular Measuring Instrument manuals by other brands

KYORITSU
KYORITSU 3005A instruction manual

Hiwin
Hiwin MAGIC Assembly instructions

Vanguard Instruments
Vanguard Instruments TRM-20 user manual

Flowserve
Flowserve IPS-Beacon VB-105 Installation operation & maintenance

Pitney Bowes
Pitney Bowes SendPro C Operator's guide

Smart Caregiver
Smart Caregiver TL-2015R2 Installation and use instructions