6-13
DSC-T20/T25_ADJ
3. Function of Each Button on Main Menu Screen
When theAutomaticAdjustment Program started, the Main Menu
screen in Fig. 6-1-14 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-14
1[Connecting the Equipment] button
A connection diagram of the equipment is displayed.
2[CONNECT] button
The mode of Camera is switched to the Adjustment Mode.
When the Adjustment Mode has switched normally, the op-
eration of the buttons 4- 0is enabled.
3[END] button
The mode of Camera is switched to the normal mode.
When the normal mode has switched correctly, theAutomatic
Adjustment Program is finished.
4[DEST NAT ON DATA WR TE] button
The “DESTINATION DATA WRITE”screen appears.
5[USB SER AL N0. NPUT] button
The “USB SERIAL No. INPUT”screen appears.
6[V DEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT”screen appears.
7[CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT”screen appears.
8[LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT”screen appears.
9[SERV CE MODE] button
The “SERVICE MODE”screen appears.
q; [DATA BACKUP] button
The “DATA BACKUP”screen appears.
qa This part indicates the version of Automatic Adjustment Pro-
gram.
1-2. ADJUSTMENT PROGRAM
The DSC-T20/T25 is adjusted by the Automatic Adjustment Pro-
gram. The Automatic Adjustment Program enters automatically
via the SeusEX the adjustment operations that were formerly en-
tered manually by the adjustment remote commander (some items
may be adjusted by manual operation on the operation screen of
the SeusEX).
1. Precautions When Using Automatic Adjustment
Program
1) TheAutomatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camera via the SeusEX. Accordingly, the Au-
tomaticAdjustment Program must be used in the environment
where the SeusEX operates.
2) TheAutomaticAdjustment Program cannot be used when the
SEUS or the SeusCam is running. Exit the SEUS or the
SeusCam before using the Automatic Adjustment Program.
3) The SeusEX must be already started on the PC when using the
AutomaticAdjustment Program.With the SeusEX not started,
some adjustment items will take time in adjustment.
4) The program run time may vary depending on the environ-
ment of the personal computer used.
2. Start of Automatic Adjustment Program
Double-click the application file (DSC-T20_T25 Auto-Adj
Ver_1.0r01.exe), and theAutomaticAdjustment Program will start.