USEFUL INFO.
USEFUL INFO.USEFUL INFO.
USEFUL INFO.
Error reader.
The BE-3D chassis supports the use of the Error Reader. This jig, is available under part number S-188-900-10
(price code S).
The displayed code shows the actual error of the TV set. Refer to the service manual or the table below for an
explanation of those codes.
ERROR CODES
02 - Protection circuit trip <ANY TIME>
03 - IIC SCL LOW <POWER UP ONLY>
04 - IIC SDA LOW <POWER UP ONLY>
05 - IIC SDA and SCL LOW <POWER UP ONLY>
06 - Jungle/chroma controller no acknowledge <POWER UP ONLY>
07 - Video switch no acknowledge <POWER UP ONLY>
08 - Tuner no acknowledge
09 - MSP no acknowledge
10 - NVM no acknowledge
11 - M3L TXD LOW <POWER UP ONLY>
12 - M3L RXD LOW <POWER UP ONLY>
13 - M3L ENABLE LOW <POWER UP ONLY>
14 - M3L TXD AND RXD LOW <POWER UP ONLY>
15 - Compact Text test fail <POWER UP ONLY>
16 - AV switch cannot power on reset
17 - Cannot initialise jungle
18 - NVM acknowledge fail after initialisation
19 - Multiple devices with no acknowledge <POWER UP ONLY>
20 - Compact Text run-time failure
21 - AVSWITCH response failure after power up
22 - JUNGLE/CHROMA controller response failure after power up
23 - Compact Text does not respond
24 - Sound processor run time failure
25 - M3L bus clock low time-out after data sent (run time failure)
26 - M3L bus clock low time-out afetr data sent (power up)
27 - M3L bus clock low time-out afetr data sent (initialization)
28 - DSP run-time failure.
Replacement of HV transformer.
Two types of high voltage transformer are used (removable or fixed focus cable). When replacing a line
transformer, replace using the original type.
Type Focus cable Part no.
A Removable 1-453-169-12
B Fixed 1-453-220-11
DEFLECT
DEFLECTDEFLECT
DEFLECT
Lines tearing when hot.
[32in models only]. Replace line driver transformer T804.
No sync in TXT mode.
Replace IC1001.
PICTURE
PICTUREPICTURE
PICTURE