SOR 815 Series Instruction manual

Form 1668 (11.18) ©SOR Inc.
1/16
These instructions provide information for
installation, electrical connection, configurations,
operation, and maintenance of the LCD digital
indicating display. The display consists of
explosion proof die cast aluminum housing,
terminal block connections for easy wiring, and a
LCD digital indicating loop powered display.
800 Series Pressure Transmitters
LCD Digital Indicating Display
General Instructions
Registered Quality System to ISO 9001
Design and
specifications are
subject to change
without notice.
For latest revision, go to
SORInc.com
NOTE: If you suspect that a product is defective, contact the factory
or the SOR
®
Representative in your area for a return authorization
number (RMA). This product should only be installed by trained and
competent personnel.
Table of Contents
Installation.......................................2
Electrical Termination..........................4
Electrical Conduit Connection ................5
Setup and Conguration .......................6
Maintenance.....................................9
Dimensions .................................... 10
e
factor
y
ri
zat
i
on
a
ined an
d
Tbl fCtt
The LCD digital indicating
display adds an additional
8V loop drop (max).

2/16
Form 1668 (11.18) ©SOR Inc.
THIS DRAWING
MCMA
TOP ALIGNMENT SLOT DISPLAY BASE
2X BASE ALIGNMENT
(ACCESS TO DISPLAY
MOUNTING HOLES)
2X BASE ALIGNMENT SLOT
(ACCESS TO DISPLAY
MOUNTING HOLES)
Installation
Ensure that wiring conforms to all applicable local and national electrical codes and
install unit(s) according to relevant nation and local safety codes.
If display was purchased with an SOR 800 Series pressure transmitter, then display will
already be installed with instrumentation. If display was purchased separately by itself
or the remote display option was selected, see below for installation instructions for
specific 800 Series pressure transmitter.
If you received a display without a sensor installed
or the remote display option was
selected
, follow the instructions below.
Unscrew the display housing cover.
To access terminal connections, rotate the
display screen to line up the holes. Using
a 1/8” flat screw driver, unscrew the
support screws. After one screw has
been removed, rotate the screen
again to line up the holes on the
opposite side in order to remove the
second support screw.
Cut the cable of the 800 series sensor
at approximately 6 inches beyond the shrink sleeving.
Slit the chrome PVC jacket from the cut end to the shrink sleeving.
Cut off the jacket and foil shield.
Thread the remaining wires through the process opening in the bottom of the
display housing, fishing the wires out through the front opening of the housing.
Apply any sealant that might be required for your application environment to the
threads on the sensor.
Thread the sensor into the display housing and tighten.
Cut the blue and drain wires off close to the jacket (unused voltage output).
Strip the remaining wires to approximately ¼ inch.
Remove the terminal block plug from the right side of the PCB.
With the wire cages facing up and the screws to the right, connect the wires
as follows (see diagrams below):
a. Top opening (loop +), should already be attached to display (mA -).
b. Second opening (loop -), attach black wire from sensor.
c. Third opening (485 A), attach brown wire from sensor. 815 only.
d. Fourth opening (485 B), attach white wire from sensor. 815 only.
e. Fifth opening (SW 1), attach orange wire from sensor. 815 and 805QS only.
f. Bottom opening (SW 2), attach yellow wire from sensor. 815 and 805QS only.
Connect the red wire from the sensor to display terminal (mA +).
Connect green wire from the sensor to lower right PCB attaching screw.
Plug this terminal block into right side of the PCB.

Form 1668 (11.18) ©SOR Inc.
3/16
C
D DISPLAY PCB REFERENCE VIEW
CABLE REFERENCE
805QS/815 SERIES
GREEN
(FROM
DISPLAY)
DRAIN
BLUE
RED
(FROM
XMTR)
GREEN
(XMTR)
BLUE
DRAIN
LCD DISPLAY
PCB ASSEMBLY
(TERMINAL BLOCKS
SHOWN IN PHANTOM)
(REFERENCE SHEETS 2 & 3)
PROTECTION SCREW IN HOUSING
ATTACH TERMINAL SPADE TO GROUND VIA
ATTACH TERMINAL SPADE SUPPLIED IN BAG.
GREEN
WHITE
WHITE
5
6
7
WIRE COLOR SPECIFICATION
FOR REFERENCE ONLY.
WIRE BY SIGNAL NAME. BLACK
RED
BLACK
BROWN
BROWN
TRANSMITTER
ORANGE
YELLOW
ORANGE
YELLOW
BLACK
RED
(TBLK TO
TBLK)
CABLE
CABLE REFERENCE
WIRING DIAGRAM
805PT
GREEN
(FROM
DISPLAY)
DRAIN
BLUE
RED
(FROM XMTR)
GREEN
(FROM
XMTR)
BLUE
DRAIN
LCD DISPLAY
PCB ASSEMBLY
(TERMINAL BLOCKS
SHOWN IN PHANTOM)
(REFERENCE SHEETS 2 & 3)
PROTECTION SCREW IN HOUSING.
ATTACH TERMINAL SPADE TO GROUND VIA
ATTACH TERMINAL SPADE SUPPLIED IN BAG.
GREEN
WHITE
WHITE
5
6
7
WIRE COLOR SPECIFICATION
FOR REFERENCE ONLY.
WIRE BY SIGNAL NAME. BLACK
RED
BLACK
BROWN BROWN
TRANSMITTER
CABLE
RED
(TBLK TO
TBLK)
BLACK
LCD DISPLAY REFERENCE VIEW
WIRING DIAGRAM
805PT
Sensor ground must be installed
before connecting TB to PCB.
WIRING DIAGRAM
805QS/815 SERIES

4/16
Form 1668 (11.18) ©SOR Inc.
CABLE REFERENCE
WIRING DIAGRAM
805PT
GREEN
(FROM
DISPLAY)
DRAIN
BLUE
RED
(FROM XMTR)
GREEN
(FROM
XMTR)
BLUE
DRAIN
LCD DISPLAY
PCB ASSEMBLY
(TERMINAL BLOCKS
SHOWN IN PHANTOM)
(REFERENCE SHEETS 2 & 3)
PROTECTION SCREW IN HOUSING.
ATTACH TERMINAL SPADE TO GROUND VIA
ATTACH TERMINAL SPADE SUPPLIED IN BAG.
GREEN
WHITE
WHITE
5
6
7
WIRE COLOR SPECIFICATION
FOR REFERENCE ONLY.
WIRE BY SIGNAL NAME. BLACK
RED
BLACK
BROWN BROWN
TRANSMITTER
CABLE
RED
(TBLK TO
TBLK)
BLACK
LCD DISPLAY REFERENCE VIEW
WIRING DIAGRAM
805PT
With the wire cages facing
up and the screws to the left,
connect the wires as follows:
a. Top opening (loop +) attach red wire.
b. Second opening (loop -), attach black wire.
c.
Third opening (485 A), attach brown wire. 815 only.
d. Fourth opening (485 B), attach white wire. 815 only.
e. Fifth opening (SW 1), attach orange wire.
815 and 805QS only.
f. Bottom opening (SW 2), attach yellow wire.
815 and 805QS only.
If you are using the flying leads provided with the display, see the associated 800
Series General Instructions for wiring information.
If you are terminating inside of the display housing, follow the instructions below.
Unscrew the display housing cover.
To access terminal connections, rotate the display screen to line up the holes.
Using a 1/8” flat screw driver, unscrew the support screws. After one screw has
been removed, rotate the screen again to line up the holes on the opposite side in
order to remove the second support screw.
To install field wiring, remove 6 inches of the jacket and foil shield as before.
Thread the wires and cable through the conduit opening and fish the wires out
the front.
Cut the blue and drain wires, if present, off close to the jacket.
Strip the remaining wires to approximately ¼ inch.
Remove the terminal block plug from the
left side of the PCB.
Electrical Termination
The LCD digital indicating display adds an additional 8V loop drop (max).

Form 1668 (11.18) ©SOR Inc.
5/16
C
D DISPLAY PCB REFERENCE VIEW
CABLE REFERENCE
805QS/815 SERIES
GREEN
(FROM
DISPLAY)
DRAIN
BLUE
RED
(FROM
XMTR)
GREEN
(XMTR)
BLUE
DRAIN
LCD DISPLAY
PCB ASSEMBLY
(TERMINAL BLOCKS
SHOWN IN PHANTOM)
(REFERENCE SHEETS 2 & 3)
PROTECTION SCREW IN HOUSING
ATTACH TERMINAL SPADE TO GROUND VIA
ATTACH TERMINAL SPADE SUPPLIED IN BAG.
GREEN
WHITE
WHITE
5
6
7
WIRE COLOR SPECIFICATION
FOR REFERENCE ONLY.
WIRE BY SIGNAL NAME. BLACK
RED
BLACK
BROWN
BROWN
TRANSMITTER
ORANGE
YELLOW
ORANGE
YELLOW
BLACK
RED
(TBLK TO
TBLK)
CABLE
WIRING DIAGRAM
805QS/815 SERIES
If using eld wiring not supplied with the sensor, use the signaling as
described in parentheses above. The signal names are also included on the
PCB silkscreen for reference. Colors may vary.
Plug the terminal block
plug with field wire into
the left side of the PCB.
Connect green field wire to lug at top of housing.
Verify there is a short loop between display
terminals (0V) and (24V).
Apply any conduit finishing as required by your
application at this time.
Turn the display over to mount to stand-offs
while carefully pressing the service loops of all
wiring to below the tops of the standoffs.
Reattach display to stand-offs in reverse order of removal so that terminal strip on
the back of the display is at the bottom of the housing.
Electrical Conduit Connection
The electrical connection may be installed on an adequately supported rigid
conduit system. Use suitable locknuts when mounting instrument to an unthread
knockout hole.
Securely connect the conduit pipe or fitting by holding flats on the electrical
connection while tightening.
Electrical connection may be rigid or flexible conduit.
Units in Hazardous Locations - Prior to removal from service, make sure
that the work area is declassied. Failure to do so could result in severe
personal injury or substantial property damage.

6/16
Form 1668 (11.18) ©SOR Inc.
Setup and Conguration
Display and pressure transmitter are configured separately. The digital indicating
display only receives the 4-20mA signal and displays linearized values from user
determined lower limit (4mA) and upper limit (20mA) values. To configure the 800
series pressure transmitter, see the respected General Instructions.
The display has 3 buttons. Push “M” to scroll through the display menus, push “Z”
to enter and confirm setting change, and push “S” to modify the setting value. The
menus are shown in the table below.
Menu Label Description Function Instruction
CLK Unlock screen to be
able to customize
display outputs
0-255=Locked ; 132=Unlocked ; 12=Restore
factory settings
SLL Set lower range value -19999-99999
SLH Set upper range value -19999-99999
UNI Set units to be
displayed
0=Blank; 1=kPa; 2=MPa; 3=Pa; 4=bar;
5=mbar; 6=psi; 7=mH2O; 8=mmH2O;
9=cmH2O; 10=mmHg; 11=Torr; 12=atm;
13=kg; 14=g; 15=mg; 16=N; 17=kN;
18=°C; 19=°F; 20=K; 21=%RH; 22=%VOL;
23=PPM; 24=%LEL; 25=ph; 26=m; 27=cm;
28=mm; 29=inch; 30=m/s; 31=Ω(ohm);
32=kΩ(kohm); 33=mV; 34=V; 35=L/Min;
36=M3/Hour
DISP Set display interface
value
0=Current value, Percent, and mA;
1=Process Variable, Percentage, and Unit;
2=Percentage, Percentage and %
DECP Set decimal position 0=None; 1=First Bit; 2=Second Bit; 3=Third
Bit; 4=Fourth Bit; Default 2.
PB Set zero migration -19999-99999 Default PB=0
KK Set Range scaling 0-1.9999 times; Default KK=1
AOLC Input lower limit
current alarming value
3.500-3.800mA
AOHC Input upper limit
current alarming value
20.800-24.000mA

Form 1668 (11.18) ©SOR Inc.
7/16
Unlock the screen in order to customize settings
a. To unlock the screen, first press the M button. This will take you to the
CLK menu
b. Press Z to enter setting.
c. To unlock the screen, enter the value 132. To restore factory default settings,
enter the value 12
d. Then modify the paramaters, press the S button. Once the desired value is
shown, press Z to confirm and choose the next parameter.
e. Once all parameters are set, press the M button to confirm and enter the
next menu
Select the 4mA corresponding value (0% of span).
a. Press Z to enter settings.
b. Press S to modify Parameters to desired values.
c. Press Z to confirm and choose the next parameter.
d. Once all parameters are selected, press the M button to confirm and enter the
next menu.
Select the 20mA corresponding value (100% of span).
a. Repeat same steps as in step 2.

8/16
Form 1668 (11.18) ©SOR Inc.
Select the units of measurement.
a. Refer to the table above for unit values
b. Repeat same steps as in step 2.
Set display interface value
a. Refer to the table above for display interface values
b. Repeat same steps as in step 2.
Select the position of the decimal point.
a. Refer to the table above for decimal position values.
b. Repeat same steps as in step 2.
Select the zero migration
a. Repeat same steps as in step 2.

Form 1668 (11.18) ©SOR Inc.
9/16
Set range scaling
a. Repeat same steps as in step 2.
Input lower limit current alarming value
a. To modify, repeat same steps as in step 2.
b. Suggested to leave at factory default settings.
Input upper limit current alarming value
a. To modify, repeat same steps as in step 2.
b. Suggested to leave at factory default settings.
c. Once Menu is confirmed, you will return the first menu (CLK).
d. To lock the screen, select a value between 0-255 that is not 132 or 12.
Maintenance
The SOR Digital Indicating Display contains no user serviceable parts and cannot
be repaired on site. If display is not functioning correctly, please contact factory for
assistance.

10/16
Form 1668 (11.18) ©SOR Inc.
ISO-90
0
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
PRODU
C
ALL D
UNL
E
THI
S
NO US
HEREO
N
MADE
W
TITLE
DIMENSIO
DISPLAY
EO NUMB
E
NOTES:
1. DIMENSIO
N
FIVE THREA
D
2. TRANSMITT
RELATION
T
VARIATION
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
1
Dimensions
Linear = mm/inches
Drawing 0098738
NOTES:
1. DIMENSION APPROXIMATE AND BASED ON A
FIVE THREAD ENGAGEMENT.
2. TRANSMITTER ORIENTATION MAY VARY IN
RELATION TO THE LCD DIGITAL DISPLAY.
VARIATION WILL NOT AFFECT FUNCTIONALITY.
1
52.0
2-3/64
104.0
4-3/32
7.4
19/64
251.2
9-57/64
230.7
9-5/64
NAMEPLATE
EXTERNAL
GROUND
PROVISION
LCD DIGITAL
DISPLAY
28.6 HEX
1-1/8
28.7
1-1/8
WRENCH
FLATS
1
1
1
PROCESS CONNECTION
1/2 NPTM W/1/4 NPTF
805PT/805QS
with LCD Display

Form 1668 (11.18) ©SOR Inc.
11/16
805PT/805QS
with LCD Display
and Pipe Kit
Linear = mm/inches
Drawing 0098745
/16
71.4
2-13/16
95.3
3-3/4
11.9
15/32
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
32.4
1-9/32
50.8
2
C
D DIGITAL
SPLAY
PIPE KIT
OPTION
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
36.5
1-7/16
230.7
9-5/64
251.2
9-57/64 35.7
1-13/32
71.4
2-13/16
133.4
5-1/4
4X 9.5
3/8
MOUNTING
HOLES
42.9
1-11/16
71.4
2-13/16
95.3
3-3/4
11.9
15/32
52.0
2-3/64
104.0
4-3/32
7.4
19/64
LCD DIGITAL
DISPLAY
2X ELECTRIC
A
CONNECTI
O
3/4 N
P
ONE SIDE PLUGG
E
1
1
1
34.1
1-11/32
154.8
6-3/32
ELECTRICAL
CABLE
ELECTRICAL
CONNECTION
1/2 NPTM
28.7 WRENCH
1-1/8
FLATS
EXTERNAL
GROUND
PROVISION
NAMEPLATE
28.6 HEX
1-1/8
PROCESS
CONNECTION
1/2 NPTM
W/1/4 NPTF
1. DIMENSION APPROXIMATE AND BASED ON A FIVE THREAD ENGAGEMENT.
2. TRANSMITTER ORIENTATION MAY VARY IN RELATION TO THE LCD DIGITAL DISPLAY.
1
VARIATION WILL NOT AFFECT FUNCTIONALITY.

12/16
Form 1668 (11.18) ©SOR Inc.
815PT
with LCD Display
Linear = mm/inches
Drawing 0098750
ISO-9001
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
PRODUCT
ALL DI
M
UNLES
S
THIS
D
NO USE
W
HEREON,
MADE WIT
H
TITLE
DIMENSION
EO NUMBER
NOTES:
1. DIMENSIO
N
FIVE THRE
A
2. TRANSMIT
T
RELATION
T
VARIATIO
N
FUNCTION
A
EXTERNAL
GROUND
PROVISION
NAMEPLATE
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
1
1. DIMENSION APPROXIMATE AND BASED ON A
FIVE THREAD ENGAGEMENT.
2. TRANSMITTER ORIENTATION MAY VARY IN
RELATION TO THE LCD DIGITAL DISPLAY.
VARIATION WILL NOT AFFECT
FUNCTIONALITY.
1
52.0
2-3/64
104.0
4-3/32
7.4
19/64
230.7
9-5/64
251.2
9-57/64
34.1
1-11/32
LCD DIGITAL
DISPLAY
PROCESS CONNECTION
1/2 NPTM W/1/4 NPTF
28.6
1-1/8
WRENCH
FLATS
28.6 HEX
1-1/8
ZERO
MAGNETIC
TARGET
SPAN
MAGNETIC
TARGET
1
1
1

Form 1668 (11.18) ©SOR Inc.
13/16
815PT
with LCD Display
and Pipe Kit
Linear = mm/inches
Drawing 0098751
ISO-9001
14685 W 1
0
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
34.1
1-11/32
32.4
1-9/32
PRODUCT CERTIFICATIO
N
ALL DIMENSIONS ARE
UNLESS OTHERWISE S
LINEAR = M
M
IN
THIS DRAWING IS THE E
X
NO USE WHATSOEVER OF
T
HEREON, NOR REPRODUCTI
O
MADE WITHOUT THE EXPRE
S
TITLE
DIMENSION DRAWING 81
5
W/PIPE KIT
NOTES:
1. DIMEN
S
AND B
A
THREA
D
2. TRANS
M
MAY V
A
THE LC
D
VARIAT
FUNCTI
28.6 HEX
1-1/8
PIPE KIT
OPTION
NAMEPLATE
EXTERNAL
GROUND
PROVISION
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
SPAN
MAGNETIC
TARGET
1
52.0
2-3/64
104.0
4-3/32
7.4
19/64
230.7
9-5/64
251.2
9-57/64
4X 9.5
3/8
MOUNTING
HOLES
35.7
1-13/32
71.4
2-13/16
133.4
5-1/4
36.5
1-7/16 11.9
15/32
71.4
2-13/16
42.9
1-11/16 95.3
3-3/4
28.6
1-1/8
WRENCH
FLATS
LCD DIGITAL
DISPLAY
ZERO
MAGNETIC
TARGET
1
1
1

14/16
Form 1668 (11.18) ©SOR Inc.
ISO-9001
146
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
PRODUCT CERTI
F
ALL DIMENSIO
UNLESS OTHE
R
LINEA
THIS DRAWIN
G
NO USE WHATSO
E
HEREON, NOR RE
P
MADE WITHOUT T
H
TITLE
DIMENSION DRAW
I
NOTE
S
1. DI
M
A
N
TH
2. TR
A
M
A
TH
VA
FU
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
1
815DT
with LCD Display
Linear = mm/inches
Drawing 0098752
52.0
2-3/64
104.0
4-3/32
7.4
19/64
234.8
9-1/4
255.3
10-3/64
34.1
1-11/32
27.9
1.10
55.9
2.20
LCD DIGITAL
DISPLAY
EXTERNAL
GROUND
PROVISION
28.6
1-1/8
WRENCH
FLATS
ZERO
MAGNETIC
TARGET
SPAN
MAGNETIC
TARGET
NAMEPLATE
1/4 NPTF HI SIDE
PROCESS CONNECTION
1/4 NPTF LO SIDE
PROCESS CONNECTION
MODEL
DP86CV
1
1
1
NOTES:
1. DIMENSION APPROXIMATE
AND BASED ON A FIVE
THREAD ENGAGEMENT.
2. TRANSMITTER ORIENTATION
MAY VARY IN RELATION TO
THE LCD DIGITAL DISPLAY.
VARIATION WILL NOT AFFECT
FUNCTIONALITY.
1

Form 1668 (11.18) ©SOR Inc.
15/16
ISO-9001
14685 W 10
5
34.1
1-11/32
25.0
63/64
10.0
25/64
108.8 APPROX
4-9/32
32.4
1-9/32
50.8
2
PRODUCT CERTIFICATION
ALL DIMENSIONS ARE
UNLESS OTHERWISE S
P
LINEAR = M
M
IN
THIS DRAWING IS THE E
X
NO USE WHATSOEVER OF T
H
HEREON, NOR REPRODUCTI
O
MADE WITHOUT THE EXPRES
S
TITLE
NOTES:
1. DIMEN
AND B
A
THREA
2. TRANS
MAY V
A
THE L
C
VARIA
T
FUNCT
SPAN
MAGNETIC
TARGET
PIPE KIT
OPTION
NAMEPLATE
EXTERNAL
GROUND
PROVISION
2X ELECTRICAL
CONNECTION
3/4 NPTF
ONE SIDE PLUGGED
MODEL
DP86CV
1
815DT
with LCD Display
and Pipe Kit
Linear = mm/inches
Drawing 0098753
52.0
2-3/64
104.0
4-3/32
7.4
19/64
234.8
9-1/4
255.3
10-3/64 35.7
1-13/32
71.4
2-13/16
40.6
1-19/32
133.4
5-1/4
27.9
1.10
55.9
2.20
4X 9.5
3/8
MOUNTING
HOLES
11.9
15/32
71.4
2-13/16
42.9
1-11/16 95.3
3-3/4
LCD DIGITAL
DISPLAY
ZERO
MAGNETIC
TARGET
28.6
1-1/8
WRENCH
FLATS
1/4 NPTF HI SIDE
PROCESS CONNECTION
1/4 NPTF LO SIDE
PROCESS CONNECTION
1
1
1
NOTES:
1. DIMENSION APPROXIMATE
AND BASED ON A FIVE
THREAD ENGAGEMENT.
2. TRANSMITTER ORIENTATION
MAY VARY IN RELATION TO
THE LCD DIGITAL DISPLAY.
VARIATION WILL NOT AFFECT
FUNCTIONALITY.
1

16/16
Form 1668 (11.18) ©SOR Inc.
5()
5()
14685 West 105th Street, Lenexa, KS 66215
913-888-2630
800-676-6794 USA
Fax 913-888-0767
Registered Quality System to ISO 9001
SORInc.com
“RD” Remote Display Option
Linear = mm/inches
Drawing 9231674
This manual suits for next models
6
Table of contents
Other SOR Transmitter manuals
Popular Transmitter manuals by other brands

RKI Instruments
RKI Instruments 65-2336RK Operator's manual

BiQuad
BiQuad THESLA TX Series user manual

HETRONIC
HETRONIC NOVA-L quick reference

Emerson
Emerson Rosemount 248 Reference manual

Duon System
Duon System AUTROL Series Operation manual

RKI Instruments
RKI Instruments 65-2643XL-05-04 Operator's manual

Endress+Hauser
Endress+Hauser Proline 500 digital Modbus RS485 Brief operating instructions

tau
tau SLIM-C Series Operation and Adjustments

NuTone
NuTone PB340K quick start guide

Hyundai
Hyundai FMT 350 CHARGE instruction manual

MuxLab
MuxLab 500777-TX-DECO Quick installation guide

Flomec
Flomec QSI Product owners manual