manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aluprof
  6. •
  7. Transmitter
  8. •
  9. Aluprof DC920 Owner's manual

Aluprof DC920 Owner's manual

Other Aluprof Transmitter manuals

Aluprof DC 448 Owner's manual

Aluprof

Aluprof DC 448 Owner's manual

Aluprof DC 920 Owner's manual

Aluprof

Aluprof DC 920 Owner's manual

Aluprof DC1675 Installation manual

Aluprof

Aluprof DC1675 Installation manual

Aluprof AC226-01 Owner's manual

Aluprof

Aluprof AC226-01 Owner's manual

Aluprof DC 448 Owner's manual

Aluprof

Aluprof DC 448 Owner's manual

Aluprof AC151-06 Owner's manual

Aluprof

Aluprof AC151-06 Owner's manual

Aluprof DC 661 Owner's manual

Aluprof

Aluprof DC 661 Owner's manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
433MHz
DC920 PROGRAMMING MANUAL
Production Plant:
ul. Gosławicka 3, 45-446 Opole, Polska
tel. +48 77 4 , fax. +48 77 4 6
e-mail: Aluprof@aluprof.eu
Central Office, Production Plant: Bielsko – Biała
ul. Warszawska 153, 43-3 Bielsko Biała, Polska
tel. +48 33 81 95 3 , fax. +48 33 82 28 512
AC
230V/50Hz
Technical specifications:
- 5 channel
- Each channel can control maximum 20 receivers
- LCD display
- Dimensions : 125x50 mm
- Power supply: V (CR24 0)
- Frequency: 4 .92MHz
- Radiated power: 10 miliwat (mW)
- Operating temperature: ~ -10oC ~ +55oC
- Average range: 200 meters (in open space)
5 meters (inside building)
Works with tubular motor’s DM 5R, DM45R, DM45RM, DM55RM, DM59RM,
DM 5EV/Y, DM45EV/Y
Company reserves the tolerance of catalog data due the different conditions usage.
In the auto mode the interval between rollup and roll down time cannot be less than 2
minutes, otherwise the display will show „Er:01”.
Changes in the rollup and roll down time, can be made only in auto and random mode.
In the auto mode you can disable one or more channels of action in auto mode by
placing the cursor on the channel and press ”P2” button, which causes flickering
of the channel.
If the operation distance of the transmitter will drop you should replace the battery.
In accordance with the provisions of the Directive of the European
Parliament and of the Council 2012/19 / EU of 4 uly 2012 on waste
electrical and electronic equipment (WEEE), it is prohibited to place of used equipment together with other wastes, marked wi
th crossed
out wheeled bin symbol. The users are obliged to tra
nsfer their used equipment to a designated collection point for proper processing.
The marking means, at the same time, that the equipment was put on the market after 13 August 2005.
These legal obligations have been
introduced to reduce the amount of
waste generated from waste electrical and electronic equipment and to ensure an appropriate level
of collection, recovery and recycling. The equipment does not contain any dangerous components, which would have any particul
arly
negative impact on the environment and human health.
UP
STOP
DOWN
K -
K +
MODE
TIME
P2
MINUTE
HOUR
UP
DOWN
AUTO MODE
MANUAL
RANDOM
2
1. Selecting the operating mode
Press the „MODE” button will
switch the transmitter
to the ‘MAN’ mode.
Press another time the
„MODE”button for 2 second will
switch the transmitter to the
‘RANDOM’mode.
Press another time the „MODE”
button will switch
the transmitter
to the ‘AUTO’ mode.
Programming of the timer can be performed only in ‘MAN’ mode.
If there will be a bigger interval during the programming than 1 seconds the timer will go from the setting mode out.
2. Setting of the timer
Hold the MODE button will
switch the transmitter to the
‘MAN’ mode.
Hold the TIME button for 5
seconds till the hour will blink
Press the „UP” or „DOWN”
button to set the hour. Press the “TIME” button
to switch between hour
and minute.
Press the „UP” or „DOWN”
button to set the minute.
Hold „TIME” buton dor 5
seconds until LCD will stop
blinking and you will see actual
time.
Programming of the timer for the automatic controls can be performed only in automatic or random mode.
If there will be a bigger interval during the programming than 1 seconds the timer will go from the setting mode out.
. Settings hours for automatic controls
Pressing „MODE” buton will
switch the transmitter to the
„AUTO” or „Random” mode.
Hold the „TIME” button
for 5 seconds till the rollup icon
will
show up.
Press the “TIME” button
to switch between hour
and minute.
Press the „UP” or „DOWN”
button to set the hour and the
minutes of the rollup time.
Press the „MODE” buton to
switch for set up rolldown time.
Press the “TIME” button
to switch between hour
and minute.
Press the „UP” or „DOWN”
button to set the hour and the
minutes of the rolldown time.
Hold the TIME button for 5
seconds save all settings.